Important!
Install the CD Drivers
before Connecting the
Hardware to the PC.
Quick Start Guide
Ulinx, USB to 1 Port Serial and
1 & 2 Port DIN Converters
INSERT THE DRIVER CD INTO YOUR CD-ROM BEFORE
PLUGGING THE HARDWARE INTO THE PC.
If you have inserted the hardware first and the Found New
Hardware Wizard launched, click cancel to exit the wizard.
After inserting the CD, the Ulinx USB Driver Installation
wizard should launch automatically. If not, navigate to the
CD-ROM drive and run setup.exe. To find your CD-ROM
drive, double click “Computer” or “My Computer” on your
desktop, then double click on your CD-ROM drive (usually
D:).
In Windows Vista, if the following dialog appears, click “Run
setup.exe”.
When the Ulinx USB Driver Installation Wizard appears,
follow the wizard to complete the installation.
When the Ulinx USB Driver Installation Wizard is done
installing the driver, using the included USB cable plug the
1. One USB port is required for each installed device.
The USB port can be native to the PC or it can be a
USB port from an installed USB hub to the PC.
Note: The devices work with USB 1.1 or 2.0 ports but
have a maximum USB data rate of 12Mbps.
Surrounding Air Ambient Temperature: 0 to 70° C
USB to Serial Device
One Meter USB Cable
CD ROM with Drivers
This Quick Start Guide
P#8506R2 ULINX 1&2 PORT_0712qsg
TDA(-)
TDB(-)
RDA(-)
RDB(-)
GND
USB
TO PC
RS-485
RS-232 and TTL Pinout (DB9 Male DTE)
1 DCD (Data Carrier Detect) Input Not Used
2 RD (Receive Data) Input Input
3 TD (Transmit Data) Output Output
4 DTR (DTE Ready) Output Not Used
5 SG (Signal Ground) Ground Ground
6 DSR (DCE Ready) Input Not Used
7 RTS (Request to Send) Output Output
8 CTS (Clear to Send) Input Input
9 RI (Ring Indicator) Input Not Used
NOTE: To remove drivers from a PC, there is an Uninstall
reference document on the CD ROM.
1. To verify the installation went correctly open the Windows
Device Manager
Scroll down to Ports,
Expand the ports by clicking on the plus sign (+), this
shows if the ports now exist on the PC.
If there are no exclamation points or other indicators of
a problem the ports should be installed correctly and
ready for use.
2. Verifying with a loopback test.
If the device is RS-232, loopback pins 2 and 3. If the
device is RS-422 or RS-485, loopback the TDA(-) to
RDA(-) and TDB(+) to RDB(+). Use the pin-out charts
for the location of each pin or terminal.
Using Hyper Terminal or similar program, connect to
the appropriate COM port. Set the desired baud rate.
Ensure Hyper Terminal local echo is OFF. (Note:
Hyper Terminal is not provided with Vista or 2003
Server)
Transmit data. If the same character string is returned,
the test is good.
Dip Switch Settings
Switch Off (left) On (right)
1 RS-422 RS-485
2 ECHO ON ECHO OFF
3 4-Wire 2-Wire
4 4-WIre 2-Wire
RS485 Pinout (Terminal Blocks)
RS-485, 4 Wire RS-485, 2 Wire
A Transmit TDA (-) Output Data A (-) Input / Output
B Transmit TDB (+) Output Data B (+) Input / Output
C Receive RDA (-) Input Data A (-) Input / Output
D Recieve RDB (+) Input Data B (+) Input / Output
E Ground Ground
Note: For models with selectable RS-422/485 configurations
Dip switches allow the module to be configured for two-wire or
four-wire, RS-422 or RS-485 modes. In two-wire mode the TDA (-)
and RDA (-) are tied together and so are TDB (+) and RDB (+),
making multi-dropping this converter into an existing network easy.
RS-485 Pinout (DB9 Female)
Pin RS-485, 4 Wire RS-485, 2 Wire
1 Not Used Not Used
2 Receive RDA (-) Input Data A (-) Input / Output
3 Transmit TDB (+) Output Data B (+) Input / Output
4 Ground Ground
5 Not Used Not Used
6 Ground Ground
7 Receive RDB (+) Input Data B (+) Input / Output
8 Transmit TDA (-) Output Data A (-) Input / Output
9 Not Used Not Used
P#8506R2 ULINX 1&2 PORT_0712qsg