EIR205 Series Industrial, Unmanaged, Ethernet Switch
Quick Start Guide (One per shipment)
Power Terminal Block (installed)
Fiber Optic Dust Covers (installed on fiber optic models)
If any item is missing or damaged, contact B&B Electronics for a replacement
Front Panel
EIR205 (All RJ45) EIR205 (1 Fiber, 4 RJ45)
1 Power Terminal Block 2 Position, Removable 2 PWR LED ON When Power Applied 3 RJ45 Ports Number Depends on Model 4 RJ45 SPD LED ON if 100 mbps 4 RJ45 LINK LED ON When RJ45 Port Linked Flashes When Data Transmitted 5 Fiber Optic SPD LED Normally OFF (100BaseFx) 5 Fiber Optic LINK LED On When Fiber Port Linked 6 Fiber Ports Number and Type Depends on Model
DIN Rail Mounting
p/n 8450R001 EIR205 3409qsg-1/2
© 2009 by B&B Electronics. All rights reserved
1. Slide and hold the DIN clip toward the bottom of the switch. Angle the top portion of the DIN mount over the top of DIN Rail.
2. Move the switch so that it is parallel with the DIN Rail.
3. Let go of the DIN Clip. The spring should return it to its original position.
Attach Power Leads
External Supply Required
Power input: 10 to 48 VDC, 3.4W maximum, Class 2
Surrounding Air Ambient Temperature: 0 to 60° C
1. Loosen the screw to open the terminal block lead clamp.
2. Insert the power lead. TB will accept 16-28 AWG wire.
3. Tighten the screw to close the terminal block lead clamp. Ensure the clamp holds the lead securely. However, do not over tighten.
NOTE: For Replacement Terminal Block Order Part #7444.
International Headquarters: 815-433-5100 www.bb-elec.com
European Headquarters: +
353 91 792444
www.bb-europe.com
(
Attach RJ45 Cable
Female RJ45
1. Auto MDI/MDI-x is supported. A straight through or cross-over cable may be used.
2. 10/100BaseT auto negotiation and full/half­duplex are supported.
Attach Fiber Optic Cable
if equipped)
1. Slider Guide
2. Slider Ridges
3. Slider
1. Ensure your fiber optic cable is terminated with the correct connector type. EIR205 switches use SC or ST connectors.
2. Fiber optic type for each port is located on the product’s side label. When connecting the cable to the switch, be sure to line up the slider guide on the cable and switch connectors.
3. Connect the fiber optic transmitter to the downstream device’s receiver and vice-versa.
MDI Cable Pinout
Pin Signal
1 Tx+ 2 Tx­3 Rx+ 6 Rx-
MDI-X Cable Pinout
Pin Signal
1 Rx+ 2 Rx­3 Tx+ 6 Tx-
p/n 8450R001 EIR205 3409qsg-2/2
© 2009 by B&B Electronics. All rights reserved
Mode and Distance Type Wavelength
Multi-mode (2 km) 62.5/125 µm 1310 nm Single-mode (15 km) 9/125 µm 1310 nm Single-mode (40 km) 9/125 µm 1310 nm Single-mode (80 km) 9/125 µm 1550 nm
Output Power RCVR Sensitivity Multi-mode (2 km) -19 to -14 dBm -32 dBm Single-mode (15 km) -15 to -8 dBm -32 dBm Single-mode (40 km) -5 to 0 dBm -34 dBm Single-mode (80 km) -5 to 0 dBm -34 dBm
Fiber Optic Cable Information
Installation Complete
1. When the network cables are attached and power is applied, installation is complete.
2. The switch will automatically discover network devices, populate its MAC address table, and pass traffic to the appropriate ports.
Mechanical Diagram
International Headquarters: 815-433-5100 www.bb-elec.com
European Headquarters: +
353 91 792444
www.bb-europe.com
Loading...