The information in this manual is subject to change without notice, and should not be
construed as a commitment by Bay Networks, Inc. Bay Networks assumes no responsibility
for any errors that may appear in this document.
Remote Annex 2000, Remote Annex 4000, Remote Annex
6100, Remote Annex 6300, MSX 5390, MSX 5391, and
MSX 5393 are trademarks of Bay Networks, Inc.
System Requirements/Compatibility....................................................................................................................................7
About The Documentation...................................................................................................................................................8
Technical Support ................................................................................................................................................................9
FastLink II Client Pack Diskettes and Licensing.................................................................................................................10
Windows Installation............................................................................................................................................................12
DOS Installation...................................................................................................................................................................21
II-1 FastLink II Concepts
Clients and Servers............................................................................................................................................................... 23
The Remote Access Administrator ......................................................................................................................................24
Serial Ports ...........................................................................................................................................................................25
The FastLink II ODI Driver.................................................................................................................................................26
The Connections Dialog....................................................................................................................................................... 29
The Setup Dialog..................................................................................................................................................................40
The Modems Dialog............................................................................................................................................................. 44
The Scripts Dialog................................................................................................................................................................47
Displaying Port Statistics .....................................................................................................................................................51
FLINK.EXE Command Line Options..................................................................................................................................56
FLINKW.EXE Command Line Options..............................................................................................................................57
Before you Connect..............................................................................................................................................................61
Making a Connection Manually ...........................................................................................................................................62
Making and Breaking Connections with Batch Files...........................................................................................................66
Using FLCACHE Launch Protection and File Caching.......................................................................................................66
Before You Connect.............................................................................................................................................................70
Before Running Windows ....................................................................................................................................................70
Connecting to the Remote Access Server ............................................................................................................................71
Connecting to NetWare File Servers....................................................................................................................................71
Using Custom Windows Icons .............................................................................................................................................72
Frontier (SuperTCP for Windows).......................................................................................................................................86
FTP (OnNet v2.1 for Windows)...........................................................................................................................................90
Microsoft TCP/IP-32 3.11 (WFW 3.11)...............................................................................................................................93
Wall Data (Rumba for Internet 1.0) ..................................................................................................................................... 102
Welcome to the world of remote network access. With the FastLink II Client Pack, you’ll be able to reach your
network from anywhere via modem, and connect to all its resources just as if you were on premises — so you
can do your work without being at work.
The FastLink II Client Pack includes two major components: the FastLink II Client and Proxy Remote Control.
The FastLink II Client
The FastLink II Client lets you dial in over a standard telephone line to a Bay Networks’ remote access server
running Point-to-Point Protocol (PPP) protocol. Once connected, you become a full-fledged node on the network
with IPX and IP access to all of its resources; you can log in to file servers, print to network printers, send and
receive e-mail, and use any other network service that would normally be available to you when directly
connected.
FastLink II has powerful features that make remote access easier and more productive than you might expect:
Dual DOS and Windows interfaces make it easy to make and break connections any time.
Iconized connections from Windows let you create icons that dial, log in to servers, and run remote
control sessions automatically.
Connection scripting allows you to easily automate connections to a Bay Networks’ remote access
server with front-end security.
5
Proxy Remote Control
One of the most important things that your FastLink II connection allows you to do is run the powerful Proxy
Remote Control software included in this package.
By installing the Proxy Master on your remote PC and the Proxy Host on your PC at work, you can take over
and operate your PC at work from your home or from the road.
Proxy runs in Windows, and can take over any PC whether it is running DOS or Windows. Proxy can even take
over more than one machine at a time; each remotely-controlled PC is displayed in a separate window.
Proxy has been optimized extensively to be super-fast over a dial-up connection!
Remote Node and Remote Control
Remote Node and Remote Control are two distinct methods of remotely accessing a network. They each have
their advantages for different types of network operations:
Of course, remote node and remote control are not mutually exclusive. When you work in Windows, you can
use both at once, each for the task it does best. For example, you might use Proxy to take over a PC at work to
perform a database search, while you load a document from the file server into your word processor for editing.
Remote Node means you become a node on the network, log in to file servers, and perform other
operations just as if you were directly connected.
Use remote node when you’d like fast keyboard response, and when the amount of data passing over
the phone line is modest. For example, reading e-mail or editing documents on the network are tasks
well suited to remote node.
Remote Control means you use a program like Proxy to control a PC that is directly connected to the
network. By using a PC on the network to do your work, you reduce the amount of data that must be
transmitted over the phone line.
Use remote control when your task would involve moving large amounts of data over the network.
For example, performing a database search or running a program that’s not on your PC are tasks that
are well suited to remote control.
System Requirements/Compatibility
FastLink II Client System Requirements
To run FastLink II you’ll need the following:
6
A 386 or higher PC.
If you’d like to run FastLink II with Windows, you’ll also need:
A high-speed serial port using a 16550A UART. For best results, we recommend that you purchase a
16550A-based serial COM port add-in card that contains a co-processor such as a Hayes ESP card.
For a discussion of the different types of serial ports, see the “FastLink II Concepts” chapter. To
determine which type you have, use the Comm Port Test feature described in the “FastLink II User
Interface” chapter.
A modem, preferably capable of 14,400 bits/second or higher over a phone line. For best results, we
recommend the use of a 28,800 bits/second (v.34) modem.
MS-DOS version 3.3 or higher.
Windows 3.1 or higher or Windows for Workgroups 3.11 or higher.
FastLink II supports both standard and enhanced mode, though enhanced mode is recommended.
Proxy System Requirements
The Proxy Master software runs as a Windows or Windows 95 application, and requires a 386 or higher PC
with at least 4 MB of RAM.
The Proxy Host software runs as a Windows or Windows 95 application, and requires a 386 or higher PC with
at least 4 MB of RAM.
The DOS Proxy Host software runs as a memory resident program, and requires DOS version 5.0 or higher; it
uses approximately 9K of conventional memory when loaded with the DPMS memory manager.
Proxy has been optimized extensively to be super-fast over a dial-up connection!
You can use Proxy over your FastLink II dial-up connection using either one of the following standard
protocols:
IPX — usually run on networks using Novell NetWare. It is not necessary for either the master or
host workstation to be logged in to a server, nor is it necessary to run a network client.
For Windows 3.x you need the Novell 16-bit (VLM) or 32-bit Client IPX protocol support.
IP — a general purpose protocol supported on a wide variety of networks and servers.
For Windows 3.x you need to use a Winsock 1.1-compliant IP stack.
7
About The Documentation
This manual is in three parts:
line.
Be sure to check each of your diskettes for a text file called README.TXT. This file contains late-breaking
information not available in this manual.
Proxy Remote Control is covered in a separate manual.
Part I includes this introductory material plus instructions on installing the FastLink II Client Pack.
Part II describes how to use the FastLink II Client to establish a connection to a network over a phone
Part III documents the IP Stacks.
8
Technical Support
If you have any problems installing or using the FastLink II Client or Proxy, there are various resources
available to help you:
This manual and the README.TXT files on your diskettes may contain the information you need to
solve the problem you are having
Your network administrator can probably answer many of your questions and give you valuable
assistance in installing and using the product.
Technical Support Internet address is support@xylogics.com (Burlington, MA) and intsupport@xylint.co.uk (UK). Most on-line services, such as CompuServe, America On Line, Delphi,
and Prodigy offer an Internet e-mail gateway.
Contact our electronic bulletin board that can be reached at (617)273-1499, modem settings: 14,400,
8, 1, N, or FTP to bbs.xylogics.com.
Visit our world wide web server via the Internet, which can be reached at
http://www.baynetworks.com.
Technical support representatives may be reached by calling 1-800-2LANWAN (800-252-6926).
When prompted you should enter an ERC of 170.
For international support, call +44 1908 222112 (Milton Keynes, UK)
9
FastLink II Client Pack Diskettes and Licensing
You are entitled to use the programs on the diskettes according to the enclosed license agreements. Here,
briefly, is a description of the contents of the diskettes and how the licensing of the various components works.
Remote PC diskettes
You are provided with a master copy of the following two diskettes used to install FastLink II on the remote PC.
You may freely distribute and copy either of these diskettes for use in connecting to Bay Networks’ remote
access server:
The FastLink II Client & Proxy diskette contains the install program (SETUP.EXE) and the
software necessary to run the FastLink II Client. This diskette also contains the Proxy Master, which
may be used with the FastLink II Client on the remote (dial-in) PC.
The Novell NetWare Files diskette contains the latest Novell client, including the NetWare VLM
redirector and NetWare utilities including LOGIN.EXE (for NetWare 3.x or 4.x), LOGOUT.EXE,
MAP.EXE, ATTACH.EXE, and SLIST.EXE.
Network PC installation diskettes
The Proxy Host diskette contains the install program (SETUP.EXE) and the software necessary to run the
Proxy Host. The Proxy Host is the machine you would like to view and operate from the remote PC.
You are provided with one or more licensed copies of a diskette used to install the Proxy remote control Host on
a network PC. Each diskette contains a Proxy Host license which may only be installed on a single PC on the
network.
NOTE: You may install no more than the number of Proxy Hosts for which you have licenses;
any additional Proxy Hosts licenses must be purchased.
10
Overview
I-2 Installing the FastLink II
Client Pack
These instructions describe how to install the FastLink II Client Pack on your PC. You can install either from
DOS or from Windows:
The Windows installation creates a group with two types of icons:
During FastLink II installation, you are asked to designate directories into which the program files should be
copied. You can change the proposed directories to any directories you want. If a directory does not exist, the
install program automatically creates it.
The Windows installation process installs all the software you need to run FastLink II with either
DOS or Windows.
The DOS installation process only installs FastLink II for use with DOS.
An icon that invokes the FastLink II Client software
Custom icons that dial a remote access server, map drives, and establish Proxy sessions
11
Windows Installation
This section describes how to install the FastLink II Client Pack on your PC using Windows. Once installed, the
FastLink II software can be used from either DOS or Windows.
Installing on the remote PC
To install the FastLink II Client and the Proxy remote control Master:
1Run SETUP.EXE from the FastLink II Client diskette.
To do so, insert the FastLink II Client diskette in drive A or B, issue the File Run command from
Program Manager, then enter:
A:\SETUP
The following dialog appears:
The Install dialog lets you check which components of the FastLink II Client Pack you’d like to
install, and into which directories.
↵↵ (from A:) or
B:\SETUP ↵↵ (from B:)
Figure 1: Windows Client Install Dialog
12
The following table describes the available options:
OptionDescription
FastLink II (Remote Node)
Dial-in clientInstalls the FastLink client
NetWare ClientInstalls the Novell NetWare client with VLM support
NetWare UtilitiesInstalls NetWare Utilities, including LOGIN.EXE
Novell TCP/IP stackInstalls the Novell LAN Workplace TCP/IP stack,
PING.EXE, and TRACERT.EXE (trace route)
Installation DirectoryDirectory for FastLink II client and NetWare files
Proxy (Remote Control)
MasterInstalls the Proxy Master
Installation DirectoryDirectory for Proxy Master files
The default is to install the FastLink II Dial-in Client, the Novell NetWare Files, Novell TCP/IP
Stack and the Proxy Master — these are the modules you’ll want to have on the PC that you’ll be
using remotely.
NOTE: To install the Proxy Host, run the SETUP program from the Proxy Host
diskette on the machine you want to take over.
Press
2If you selected NetWare Client, and already have installed VLM support on your PC, you will be
prompted to either use the VLMs you have installed, or install newer ones.
A dialog similar to the following will appear if VLMs are detected:
Click
VLM]
to proceed with installation.
[Install]
Figure 2: VLM Already Installed Dialog
[Use Current VLM]
to install VLM 1.20B from the FastLink II diskettes.
to use the existing VLMs from the installed directory, or
[Install New
13
3If you selected Novell TCP/IP Stack, this will install Novell’s LAN Workplace TCP/IP stack which
lets you run IP-based applications.
Note: IP applications such as a Web Browser, FTP client, email client, etc., are not
included with this package.
To use TCP/IP effectively you need to refer to a DNS (Domain Name System) server. DNS lets you
use symbolic names (such as xyz.company.com) instead of specific IP addresses.
A dialog similar to the following will now appear:
Figure 3: TCP/IP Domain Name System Configuration Dialog
You should now enter the following information:
Domain Name — the DNS domain name; each network uses a top-level domain name such as
company.com.
Primary DNS address— the IP address of the DNS name server that will be tried first to resolve
symbolic names; if this server is not available, then the secondary DNS address will be tried instead.
Secondary DNS address— the IP address of the DNS name server that will be tried if the primary
DNS address cannot be reached; if this server is not available, then the attempt to resolve the
symbolic name will fail. This parameter is optional, but it is strongly recommended.
4You may be prompted to overwrite files such as NET.CFG and FLINK.INI that may have been
previously installed. For each of these prompts, answer
to keep the previous version. If you answer
The FastLink II files will now be copied to the destination directories.
, the file will be backed up.
[Yes]
to overwrite the existing file, or
[Yes]
14
[No]
A file copy progress indicator will now appear:
Figure 4: Copy Progress Dialog
To cancel the copy operation hit the
operation.
5After the file copy, you will be asked to select one of the two supported connection types for your
Remote Annex Software.
The following dialog will now appear:
Figure 5: PPP or SLIP Selection Dialog
Click on the connection type you wish to use:
PPP— Choose this if you are running Remote Annex Software Release 10.1 or higher. This
selection enables IPX and IP remote access over PPP.
[Cancel]
key; this will prompt you to abort the installation
SLIP— Choose this if you are running a Remote Annex Software release that is earlier than
Release 10.1. This selection enables IPX remote access over SLIP.
15
6You will now be asked if you wish to configure the FastLink II client settings. The following prompt
will now appear:
Figure 5: Initialization Confirmation Prompt
If you answer
Setup dialog chosen for you.
The following dialog will now appear:
You can now enter the following configuration information required by FastLink II:
Serial Port— Set the Serial Port to the port to which your modem is connected. Normally, this will
be either COM1 or COM2.
to configure the settings now, the FastLink II client will be started with the
[Yes]
Figure 6: FastLink II Setup Dialog
Modem— Select a Modem from the list of preconfigured modems. Select Default if your modem
does not appear on the list.
Baud Rate— Select the baud rate at which your serial port and modem will communicate.
When you are done entering settings, press
NOTE: Any settings you enter here can always be changed by invoking this same
dialog from the FastLink II user interface. Refer to the chapters “FastLink II
16
[Save]
, then press
[Exit]
.
Concepts” and “The FastLink II User Interface” for more information on configuring
FastLink II.
7If you installed the NetWare Client you will get a message stating that VLMs are installed on your
system. This screen includes information on the batch files to load your dial-up stack for NetWare
and/or TCP/IP.
Figure 7: NetWare Information Dialog
Click
8A final screen appears with a message stating that the software has been successfully installed. In
addition, you will be asked to reboot your PC so that any changes to your system files can take place.
Click
to continue.
[OK]
to reboot now.
[Yes]
Figure 8: Final Install Dialog
17
Installing Proxy Host on the network PC
The Proxy Host can be installed from Windows or Windows 95. There are some differences between the
Windows and Windows 95 installation; however, the installation steps are identical. Before installing the Proxy
Host, make sure that you close all other applications that you have running.
To install the Proxy Host from Windows or Windows 95:
1Use the Windows 95
SETUP.EXE. For example, to install from the diskette in drive A or B you would enter:
A:\SETUP
2You will be presented with the introductory “Welcome” dialog. Click
3You will be presented with the “Software License Agreement” dialog. Before proceeding, make sure
that you read and agree with the terms of the license agreement. Click
agreement terms and continue
4You will be presented with the “Choose Destination Location” dialog. You may either use the
default destination directory, enter a new one, or click
to use this installation location and continue.
5You will be presented with the “Select Program Folder” dialog. You may use the default folder
name Proxy, enter a new one, or choose from an existing folder. Click
location and continue.
6You will be presented with the “Proxy Host Setup" dialog. Set the Proxy Host station Name and
Password that will be used to identify your PC to Proxy Masters as follows:
Name
to connect to this host. You should make sure that the name you assign is different from
that of other host PCs, or Proxy will not be able to tell them apart.
You will probably want to assign a station name that makes it easy to identify the PC.
Combining the name of the person who uses the PC with the PC’s brand or type is usually
a good practice; for example, “Jean’s P200” or “Gracie’s Model 60.”
Start Run
↵↵ (from A:) or
is a unique host station name that identifies the PC to a Proxy Master that may want
or Windows Program Manager
B:\SETUP
↵↵ (from B:)
Browse
File Run
to search for a directory. Click
command, and run
to continue.
Next
to accept the license
Yes
to use this installation
Next
Next
After entering the Name and Password, Click
Password
Whenever a Proxy Master tries to connect to your PC, that password will have to be
supplied before the connection is accepted.
The password can be any sequence of up to 16 characters. The password is never
displayed on screen; as you edit it, asterisks appear in place of the characters you type.
You can change the password at any time.
If you do not want to require a password for access, you should leave this field completely
blank.
lets you restrict access to your PC to only certain Proxy Master users.
18
Next
to continue.
7You will be presented with the “Start Copying Files" dialog prior to actual file copying. At this point,
you can go back to any previous dialog and change your answers by pressing
start copying the Proxy files and continue.
Back
. Click
Next
to
8Setup is now finished copying files to your PC. Click
to restart Windows and complete the installation process.
9You will receive a final message box requesting that Windows be restarted. Click
Windows.
Your PC will now be available as a Proxy Host whenever you start Windows.
System File Modifications During Installation
During installation from Windows, certain modifications will be made to your system files:
When the FastLink II Client is installed, a line is added to your AUTOEXEC.BAT that loads a
Novell program called DPMS.EXE, if it is not there already.
DPMS is an extended memory driver that allows the FastLink II driver to reduce its DOS footprint
dramatically.
When the Novell NetWare files are installed, the following changes are made to accommodate VLM
installations:
−−In CONFIG.SYS, lastdrive=z is inserted, or existing lastdrive settings are modified to
lastdrive=z.
−−In WIN.INI, nwpopup.exe is inserted in the [Windows] section
−−In SYSTEM.INI, various items are inserted for the VLM client
When the Proxy Master is installed, no changes will be made to your system files.
with Restart Windows now checked
Finish
Restart
When the Proxy Host is installed, your SYSTEM.INI file is modified as follows:
−−In the [boot] section — user.exe=user.exe changes to user.exe=phostusr.exe. This
allows Proxy to control your display, keyboard, and mouse when Windows starts, and
launches PHOSTWIN.
−−In the [386enh] section — device=prxv.vxd is added for Windows 3.x.
−−A [Proxy Host] section is added to record settings for Proxy.
In Windows 95, Proxy Host is added to the Add/Remove Programs area in your Control Panel; if
selected, this will remove the Proxy Host from your PC.
NOTE: Modified system files such as WIN.INI, SYSTEM.INI, AUTOEXEC.BAT, and
CONFIG.SYS will be backed up with numbered extensions (e.g., AUTOEXEC.BAT
renamed to AUTOEXEC.000).
19
DOS Installation
This section describes how to install the FastLink II Client on your PC in DOS.
To install the FastLink II Client, start from the DOS prompt and:
1Insert the FastLink II Client diskette in drive A or B, then make that drive current by typing either
or B:, then pressing ↵↵.
2Enter the following command:
FINSTALL
Follow the directions on the screen. The FINSTALL program copies the FastLink II Client software
into the directory of your choice.
3Select the PPP or SLIP version of the FastLink II Client.
PPP - Choose this if you are running Remote Annex Software
Release 10.1 or higher. This selection enables IPX and IP remote access over PPP.
SLIP - Choose this if you are running a Remote Annex Software Release that is earlier than Release
10.1. This selection enables IPX remote access over SLIP.
3Make the FLINK directory current and type:
FLINK
The FastLink II main menu will appear.
4Select Setup. The Setup dialog will appear.
You can now enter configuration information required by FastLink II to operate your system:
Serial Port — Set the Serial Port to the port to which your modem is connected. Normally, this will
be either COM1 or COM2.
↵↵
↵↵
A:
Modem— Select a Modem from the list of preconfigured modems. Select Default if your modem
does not appear on the list.
Baud Rate — Select the baud rate at which your serial port and modem will communicate.
When you are done entering settings, press
then select
NOTE: Any settings you enter here can always be changed by invoking this same
dialog again.
5Edit your AUTOEXEC.BAT file and add a command to run DPMS.EXE, preferably as the first line
of the file:
C:\FLINK\DPMS.EXE
to return to DOS.
Exit
. Then press [Done] to return to the main menu,
[Save]
20
NOTE: DPMS is a Novell extended memory driver that allows the FastLink II ODI
driver to reduce its DOS footprint dramatically.
6Before running FastLink II, reboot your PC.
21
II-1 FastLink II Concepts
Clients and Servers
In the world of remote access, you’re either a client or a server.
The FastLink II client and Remote Annex server communicate using a standard protocol called Point to Point
Protocol (PPP). Most modern remote access systems use PPP as the underlying basis for communication.
A remote access client is a PC that can connect to a remote access server over a telephone or other
remote link, and thereby get a connection to the network. Your PC becomes a remote access client
when you use the FastLink II Client software to connect to a remote access server.
A remote access server is a piece of hardware and/or software that is connected to a network and
can accept calls from clients who want access to that network. The job of the remote access server is
to connect clients to the network.
A Bay Networks’ Remote Annex server is an example of such a server. The Remote Annex server
accepts calls from the FastLink II Client.
23
The Remote Access Administrator
The Remote Annex Administrator is the person in charge of maintaining your remote access server and making
sure that people are able to connect to it.
Your administrator should provide you with:
Your Administrator can also help you configure the FastLink II Client software, make sure your modem works
correctly, and provide you with ongoing support as you need it.
A user name that identifies you to the Remote Annex server.
A password to allow the Remote Annex server to authenticate your identity.
The phone number of the Remote Annex server.
24
Serial Ports
Your PC and modem communicate with each other over a serial port. The type of serial port you have and the
speed (baud rate) you set it to affect the performance of your FastLink II connection.
The most common type of serial port is based on the 8250 and, more recently, the 16450 Universal
Asynchronous Receiver Transmitter (UART). This type of serial port handles a single character at a time in
either direction.
An enhanced serial port, called the 16550 UART, is now used in many high-end workstations and laptops. The
16550 can buffer up to 16 characters at a time in either direction. Because it can buffer so many characters, the
risk of losing data is minimized and the serial port can operate at a higher baud rate and at a lower error rate.
NOTE: You can find out which type of serial port(s) you have by using
FastLink II’s
All this leads up to the $64 question: What baud rate should you set the serial port to?
First, you need to know what baud rate your modem requires. It’s possible that your modem requires a specific
baud rate and you’ll have to set your serial port to that.
But most modern modems automatically adjust to any baud rate you set. So here are some rules of thumb:
Comm Port Test
option. For more information, refer to the section “Housekeeping.”
Set the highest baud rate possible to get the most benefit out of the compression in your modem.
Experiment with different baud rates, checking Port Statistics to make sure that the error rate isn’t too
high. (The ratio between Rx Total and Rx Errors should be about 10,000 to 1 or better.)
If you have a fast PC (for example, a 50 MHz 486) and a 16550 UART, you can probably set the
baud rate as high as you like and not worry about it too much.
25
The FastLink II ODI Driver
ODI (Open Data-link Interface) is the Novell standard upon which network communications is based. The ODI
standard describes the different layers required for network communications and how they should interact.
FastLink II is fully compliant with this standard, and allows you to operate standard Novell networking software
transparently.
You may already be familiar with other ODI drivers. NE2000.COM, for example, is an ODI driver that operates
an Ethernet card, just as the FastLink II ODI driver operates a modem or other communications device.
The FastLink II ODI driver (FLODI.COM) is the main component of FastLink II. It allows communication with
a Remote Annex server that uses Point-to-Point protocol (PPP), a standard data-link level protocol.
The FastLink II ODI driver allows both IPX and IP protocols to run over the PPP connection. FastLink II
includes Novell’s IPX and LAN Workplace IP stack. There are also numerous vendors that supply IP stacks
which are also compatible with FastLink II.
These are the various components that must be loaded to establish an IPX connection and attach to NetWare
servers. These are, in order of loading:
LSL.COM — The Link Support Layer. This is the “traffic cop” that manages the communication between ODI
drivers and protocols such as IPX and IP.
FLODI.COM — The FastLink II ODI driver. This module sends and receives packets of data over the phone
line on behalf of IPXODI or an IP ODI driver.
IPXODI.COM — The IPX protocol. IPXODI finds the FastLink II ODI driver and uses it for all packet
communications over the network.
VLM.EXE or NETX.EXE — One of these must be loaded before you can attach to NetWare file servers. Both
use IPX to communicate with file servers. NETX is the older NetWare shell technology. VLM is the newer
NetWare redirector and provides improved performance (burst mode) and additional features that are useful for
remote access.
You can establish an IP connection at the same time that you run IPX. Depending on the IP stack you are using,
you may need to load additional TSRs, or make changes to your system files.
NOTE: Refer to your IP stack vendor’s documentation for how to load TSRs and modify your
system files. See the FastLink II IPSTACKS.HLP help file for the latest information on IP stack
configuration with FastLink II.
26
Overview
II-2 The FastLink II User
Interface
The FastLink II User Interface can be run from DOS or Windows:
FLINK.EXE and FLINKW.EXE perform mostly the same functions and operate the same way. You can use one
or the other as the need arises.
The sections that follow describe the dialogs that allow you to control FastLink II. In most cases, the
documentation refers to Windows dialogs as examples, but since these dialogs contain the same options as the
DOS dialogs, you can use them as reference whether you are running FastLink II from DOS or Windows.
At the end of this chapter, you’ll find information on running FLINK.EXE and FLINKW.EXE with command
line parameters. Command line operation of FastLink II lets you use batch files in DOS or icons in Windows to
automate connecting and disconnecting.
While this chapter describes how to connect to a Remote Annex server from the Connections dialog, before you
actually attempt a connection you should read one of the chapters that follow: either “Connecting From DOS” or
“Connecting From Windows”. Those chapters will give you more complete information on how to set up your
system in general prior to connecting.
The FastLink II User Interface runs whether or not the FastLink II ODI driver has been loaded; if it is not loaded
you won’t be able to connect to a server, though you will be able to change settings.
FLINK.EXE is the DOS version of the user interface.
FLINKW.EXE is the Windows version of the user interface.
Running the FastLink II User Interface from DOS
To run the FastLink II User Interface from the DOS command line, type:
↵↵
FLINK
The FastLink II main menu appears.
Operating the FastLink II User Interface dialogs is fairly intuitive and similar to operating dialogs in Windows.
You can use either the keyboard or the mouse. If you are using the keyboard, consult the following table for the
basic operations that operate the menus and dialogs.
27
OperationInstruction
To select a menu itemUse the up and down arrows to select the
To move the highlight from one item to
item you want, then press
Use
[Tab]
and
[BackTab]
[Return]
.
another
To use a drop-down box
Highlight the box and press
the up and down arrows to select the item
To use a checkbox
you want, then press
Highlight the item and press
[Return]
check or uncheck the box.
To select a radio-buttonHighlight the selected item, then use the
up and down arrows to change the
selection.
To modify an edit fieldHighlight the field and use left and right
arrow,
[Del], [Backspace]
, and standard
text keys to edit the data.
To press a command button
Press the function key (
[F1], [F2]
shown on the button.
To return to the previous screen
To return to DOS from any dialog
Press
Press
.
[Esc]
[Alt-F10]
.
[Return]
.
[Space]
, etc.)
.
, use
to
Running the FastLink II User Interface from Windows
To run the FastLink II User Interface from Windows, use the
C:\FLINK\FLINKW
You can also double-click the FastLink II Client icon in your FastLink II Windows group. Either way, the
FastLink II User Interface appears with the Connections dialog displayed.
The radio buttons at the left of the screen let you select which dialog to display. Just click the dialog you want,
and it will appear in the window.
File Run
28
command and type the following:
The Connections Dialog
The Connections dialog is the focal point of activity in FastLink II. It is from this dialog that you connect and
disconnect from servers, and save the characteristics of connections for future use. Specifically, you can:
A connection is a named collection of settings that describe how to dial up a server.
If you always connect to the same server, you may need only one connection. If you call different servers, or
need to use different settings for different purposes, you can create a named connection for each.
Connection settings include:
Connect to a server
Disconnect from a server
Create and remove named connections
Edit the settings for any connection
Enter terminal mode to view modem activity, operate the modem directly if necessary, or
communicate with security devices at the server
Your user name and password, to allow the server to authenticate your identity
The phone number of the server
An option to request that the server dial you back at a specified phone number
An option to use a predefined dialing script when connecting
An option to pop up Terminal mode when connecting
Settings for the IPX protocol
Settings for the IP protocol
29
To display the Connections dialog, check the Connections button at the left of the screen. A dialog similar to the
following appears:
Figure 2: Connections Dialog
Editing Connection Settings
To edit the settings for a connection:
1Highlight the Connection drop-down box, and select the connection whose settings you want to edit.
2Edit any of the individual settings, as described in the sections below.
3Press
User name
Your Administrator will assign you a user name. Your user name identifies you to the Remote Access server. To
enter your user name, highlight the User name field and enter the name your Administrator assigned you.
Password
Your Administrator will assign you a password. This password allows the Remote Annex server to authenticate
your identity.
You can save your password as part of the connection settings. Your password will be provided to the server
automatically each time you connect. To specify your password:
to make your changes permanent.
[Save]
30
1Highlight the Password field and enter your assigned password.
The password appears as asterisks as you type, so be careful to enter it correctly.
2If the Prompt for password box is checked, uncheck it.
You can also specify that your password is required each time you connect.
1If the Password field is not blank, highlight it and press [Del] to remove any password you may have
previously entered.
2Check the Prompt for password box.
Phone number
This is the phone number of the server. Your Administrator can supply you with this number. Your modem uses
this number to gain access to the network.
To specify the phone number, highlight the Phone number field and enter the phone number of your server. If
any special access codes or modem controls (such as pauses) are required, be sure to include them.
Dialback
Dialback is a two-step process. First, your PC dials the server, and, after exchanging some information such as
your phone number, both sides hang up. Then the server dials your PC and establishes a connection.
If you want to use dialback:
1Check the Request dialback box.
2Highlight the Dialback number field and enter the phone number of your modem.
If you don’t want dialback, uncheck the Request dialback box.
You can also leave it up to the server as to whether to use dialback. Just uncheck the
dialback
elects to use dialback.
box, but enter a phone number in the
Dialback number
field in case the server
31
Request
NOTE: Your Administrator may have set up special rules for dialback. For security purposes,
you may be required to use dialback, and only from particular phone numbers known to the
server. It’s also possible that you are precluded from using dialback. Your Administrator can
help you set up the proper dialback options.
Execute Script
You can execute a script which allow you to easily automate connections to a Remote Annex server with frontend security.
To specify a script to use, highlight the Execute Script drop-down box and select a script from the list.
NOTE: If you plan to connect to a terminal server that prompts with "Login:" and "Password:",
choose
Standard
server.
Terminal Mode on Connect
Terminal mode on connect is useful if you need to communicate with a communications server or security
device that requires you to enter information before connecting to the Remote Annex server. Checking this box
will automatically start Terminal Mode in the following situations:
, or use the Scripts dialog to create a new script for your Remote Annex
When you click Connect, FastLink II will pop up the Terminal Mode screen, which is equivalent to
pressing
[Terminal]
If you run FastLink II from the command line with a connection name, the Terminal Mode screen
will automatically pop up.
In Windows, if the connection is broken, when redial begins the Terminal Mode screen will pop up.
.
32
IPX Protocol Settings
The IPX Protocol Settings dialog lets you configure the use of IPX over the connection. When you click the
[IPX Protocol Settings] button, a dialog similar to the following appears:
If you’d like to use IPX, check the Enable IPX box.
Figure 3: IPX Protocol Settings Dialog
NOTE: Novell NetWare uses IPX for all its communications. Be sure to check
you plan to log into NetWare file servers or use other programs that rely on IPX, such as Proxy.
Network and Node Address
When you connect, you will be assigned an IPX address that combines the Remote Annex server’s network
number with a node address. FastLink II gives you a choice as to how your network and/or node address gets
assigned:
You can use your FastLink II-assigned network and node address by checking one or both of the
Client Assigned checkboxes.
You can let the Remote Annex server assign a new, unique network and/or node address to your PC
each time you connect by unchecking one or both of the Client Assigned checkboxes.
Enable IPX
if
33
Duplicate IPX Addresses
Your Remote Annex server does not let two users with the same IPX address connect simultaneously. If
someone else with your IPX address has already dialed in, you will get an error when you try to connect.
If you use FastLink II’s node address that was generated at installation, the odds of this happening are very
small. If it does happen to you, go to the Setup Dialog and generate a new random node address to resolve the
conflict.
Your node address is saved in FastLink II’s configuration file, FLINK.INI. The most likely way for two people
to get the same node address is by copying FLINK.INI. This might be done as a shortcut to configuring several
similar machines. If you think your FLINK.INI may be a copy of someone else’s, just regenerate a new node
address to be sure of avoiding conflicts.
Broadcast Filtering
The Broadcast Filtering settings let you suppress various types of broadcast packets from the network to reduce
unnecessary traffic.
A broadcast packet is one which is not directed to one particular node, but to every node on a network. Networks
are normally buzzing with broadcast traffic. File servers and other network services advertise their presence
using broadcasts, routers keep each other up-to-date using broadcasts, client workstations search for servers to
connect to using broadcasts, and so on.
The problem with broadcasts is that they get sent to everyone, even nodes that will ignore them. A large network
with many servers and routers can generate levels of broadcast traffic that, though easily accommodated on a
local cable, can flood a modem connection.
FastLink II lets you decide which types of broadcasts from the network your PC will receive. Check ReceiveRIP/SAP to receive RIP and SAP broadcasts, uncheck it to suppress these broadcasts.
RIP/SAP broadcasts are the most common type. These are the broadcasts that servers and routers use to
communicate with each other. In general, you’ll want to suppress RIP/SAP broadcasts.
34
IP Protocol Settings
The IP Protocol Settings dialog lets you configure the use of IP over the connection. When you click on the [IP
Protocol Settings] button, a dialog similar to the following appears:
FastLink II gives you two choices as to how your IP address gets assigned:
Figure 4: IP Protocol Settings Dialog
To request that a dynamic IP address be assigned to you when you connect:
1Check the Enable IP box.
2Check the Dynamic IP address button.
To request to use a static IP address when you connect:
1Check the Enable IP box.
2Check the Static IP address button.
3Highlight the Address field and enter a valid IP address in the format xxx.xxx.xxx.xxx, where xxx is
You can request a dynamic IP address for your PC each time you connect. This IP address will be
based on how the Remote Annex server is configured.
You can specify a static IP address. This IP address will be used each time you connect.
a value between 0 and 255.
NOTE: An invalid static IP address may be rejected by the server when you connect.
If this happens, you may receive a dynamically-assigned IP address, or your request
for IP will be rejected. Check with your system administrator to make sure that you
are using a valid IP address.
35
Static IP Address
To configure your IP stack with a static IP address, you also need to provide the Remote Annex server’s IP
address (as a gateway) and the IP subnet mask. When configuring FastLink II’s IP Protocol Settings, enter the
same static IP address in the Static IP address field.
Dynamic IP Address
To configure your IP stack to use a dynamic IP address, you need to specify RARP (Reverse Address Resolution
Protocol), BOOTP, or DHCP (Dynamic Host Configuration Protocol). FastLink II will automatically provide
the negotiated IP address to the IP stack when a RARP or BOOTP request is made. When configuring FastLink
II’s IP Protocol Settings, select Dynamic IP address.
NOTE: If you use DHCP, ensure that you have a DHCP server on your network.
IP Stack Configuration
FastLink II uses ETHERNET_II for its default frame type. Do not change this frame type in the NET.CFG file
or FastLink II will not work with IP.
There are numerous interfaces available to communicate between TCP/IP stacks and the ODI driver. Some
stacks use the ODI interface directly, while others require a “shim” which converts calls from another interface,
such as a packet driver, to the ODI driver.
NOTE: Refer to your IP stack vendor’s documentation for how to load TSRs and modify your
system files. See the FastLink II IPSTACKS.HLP help file for the latest information on IP stack
configuration with FastLink II.
Adding a Connection
To add a new connection:
1Press [Add]
The new connection is displayed, and its settings are initialized based on the previously-selected
connection.
2Edit any of the individual settings.
3Press
and enter a name for the new connection when prompted.
to make your changes permanent.
[Save]
36
Removing a Connection
To remove a connection from the list:
1Highlight the Connection drop-down box, and select the connection you’d like to remove.
2Press
[Remove]
Connecting to a Server
Before you connect, be sure that:
Refer to either of the chapters “Connecting From DOS” or “Connecting From Windows” below for complete
information on how to set up your system in general prior to connecting.
To make the connection:
1Be sure the Connection Status line at the bottom of the screen indicates “Idle.” If not, Press
2Highlight the Connection drop-down box, and select the appropriate connection.
3Press
You have set the connection settings correctly for dialing the Remote Annex server.
You have set the correct configuration and preferences in the Setup dialog.
You have loaded all the required drivers, such as LSL.COM and FLODI.COM.
[Disconnect]
[Connect]
FastLink II activates the modem and dials the server. Once the phone link is created between the two
modems, FastLink II and the server exchange the information necessary to establish the connection.
If all goes well, after a few seconds the connection is established.
to remove the connection from the list.
to cancel any previous connection or connection-in-progress.
.
The Connection Status line at the bottom of the screen lets you monitor the progress of the
connection.
Once the connection is established, a message box appears showing that the operation was successful, and also
details features of the connection.
37
The following table describes the information returned in the message box:
ItemDescription
Modem reports ...If your modem returned a CONNECT string, it will be
displayed along with the speed of the modem-to-modem
connection over the telephone line in bits/second.
(
NOTE: some modems may only display the baud rate
between the PC and modem.)
Baud rate ...Displays the baud rate between your PC and modem.
This is the same baud rate entered in the Setup dialog.
Connected to...Displays the name of the server to which you are
connected, and your authenticated user name.
IPX Address:If a valid IPX connection has been established, this
message will display the connection’s IPX address.
Local IP Address:If a valid IP connection has been established, this
message displays the connection’s IP address.
(
NOTE: if you have requested a client-assigned IP
address, make sure that the reported address matches it
or your IP connection may not work.)
Remote IP Address:If a valid IP connection has been established, this
message displays the IP address of the remote server
(or gateway) to which you are connected.
Maximum connect timeIf the server limits your connect time, this message
displays the maximum period of time that the server will
permit you to stay connected.
38
The Connection Information File
If you need to refer to the information displayed in the message box at a later time, simply view the
CONNECT.TXT file in the FastLink II directory.
This file is created each time you make a new connection and contains a copy of the message box strings. You
can also view the date and time of the CONNECT.TXT file to determine when the connection was started.
The Connection Failure Message
If your attempt to connect to the server was unsuccessful, an error message appears, indicating the reason that
the connection couldn’t be established. For example, the server’s phone number might have been busy, or you
may have entered the wrong user name or password and failed authentication.
The following shows a typical error message:
Figure 5: Connection Failure Message Box
If you have repeated or unexplained connection failures, see Appendix A “FastLink II Connection Errors” for
recommended actions.
Disconnecting
Once you’ve completed your work, press
disconnecting, make sure you’ve logged out of any file servers you might have been attached to, and you’ve
disabled any other software that might rely on a valid connection to the network.
You can also use
in progress.
NOTE: If you have connected from Windows and then disconnect before logging out of all
servers you may receive network error messages. If you are asked to “Retry or Cancel”,
simply answer “Cancel” and continue.
[Disconnect]
[Disconnect]
if you change your mind after choosing
to terminate your connection with the server. Before
39
[Connect]
. This aborts the connection
Terminal Mode
Terminal Mode provides a full-screen display that permits you to monitor FastLink II’s interaction with the
modem, and lets you type directly into the modem as well. You might use Terminal Mode for the following
reasons:
You enter Terminal Mode from the Connections dialog by choosing
text you type on the keyboard is sent directly to the modem, and any text returned or echoed from the modem
appears on the terminal display.
While in Terminal Mode you can:
NOTE: You cannot use
and is sent to the modem.
To view modem result strings
To diagnose modem problems
To operate the modem directly if necessary
To communicate with a communications server or security device that requires you to enter
information before allowing a connection.
Press
Press
Press
The Setup Dialog
[Connect]
[Disconnect]
[Close]
to dial the server and make a connection.
to break the current connection.
to return to the Connections dialog.
to return from Terminal Mode.
[Esc]
[Terminal]
[Esc]
. Once in Terminal Mode, any
is treated as a text character
The Setup dialog lets you specify configuration information and preferences. The Setup dialog lets you:
Specify your modem brand, baud rate, and number of stop bits
Specify the serial (COM) port to which the modem is attached
Edit settings for automatic redial in case of a dropped phone connection
Create a specific node address or generate a new random node address
40
To display the Setup dialog, check the Setup button at the left of the screen. A dialog similar to the
following appears:
Figure 6: Windows Client Setup Dialog
You can now edit any of the items shown. When you are through editing, press
permanent.
Port Settings
The Port Settings let you specify the brand of modem you are using and the settings for the serial connection
between the PC and modem.
To specify the port settings:
1Highlight the Modem drop-down box and select a modem from the list.
2Highlight the Baud rate drop-down box and select a baud rate.
3Highlight the Stop bits drop-down box and select either 1 or 2 stop bits. (In almost all cases, you
to make your changes
[Save]
NOTE: If you don’t see your modem brand on the list, you can either choose an
equivalent modem, choose
Modems dialog to create an entry for your modem.
should set this value to 1.)
Default
which works with most modems, or use the
41
Serial Port
Your PC and modem communicate with each other over a serial port. A PC may have up to four serial ports,
labeled COM1 through COM4. Either your modem is connected to one of these ports by cable, or you have an
internal modem with a built-in serial port. In either case, you need to select the correct serial port for FastLink II
to operate.
For the Serial Port, you may choose any of the available COM ports on your PC, or you may choose Custom. If
you select one of the standard COM ports, FastLink II automatically enters information in the Port address and
Interrupt(IRQ) fields. However, if your serial port has a non-standard configuration, you should select Custom
and set Port address and Interrupt (IRQ) to the correct values for your serial port.
To specify the serial port to which your modem is attached:
1Highlight the Serial Port drop-down box, and select a serial port from the list. You can choose any
2If you selected Custom, highlight the Port address field and enter the correct value.
3If you selected Custom, highlight the Interrupt (IRQ) field and enter the correct value.
Automatic Redial
Every once in a while, the connection between your modem and the server’s modem may break. This could be
because the phone line goes down, or it could be the result of modem errors.
available COM port, or you can select Custom.
FastLink II can automatically detect the dropped line, redial the server, and re-establish the broken connection.
Usually, once a connection is re-established you should be able to use the network as before — any interrupted
operation will usually just pick up where it left off.
Three parameters control how FastLink II tries to re-establish a broken connection:
Number of redial tries — The maximum number of redial attempts FastLink II will make in case it gets a Busy
signal. You can set this value to 0 to turn off redial entirely.
Seconds to wait before redial — The time to wait before the first redial. This gives the server time to realize
that the connection is broken and hang up its phone.
Seconds between redials — Determines the frequency of redial attempts after getting busy signals.
To configure FastLink II’s automatic redial settings:
1Highlight the Number of redial tries field and enter the desired value. Enter 0 if you do not want
FastLink II to redial at all.
2Highlight the Seconds to wait before redial field and enter the desired value.
3Highlight the Seconds between redials field and enter the desired value.
42
Node Address
Every workstation on the network has a unique node address (also known as the MAC or Media Access Control
address). This node address is used as your IPX node address if you selected client-assigned IPX address.
When you first install FastLink II, it will automatically generate a random node address for you. We recommendthat you use the node address that you get upon installation. However, you can change the value if you like.
To specify a node address directly:
To generate a random node address:
Enter the new address into the Node Address field. This address is entered as 12 hexadecimal
characters (0 through 9, A through F) to represent the 48-bit node address.
Clear the Node Address field of all text by choosing [Del] or [Backspace], then press [Tab].
43
The Modems Dialog
The Modems dialog lets you maintain FastLink II’s list of available modems and edit their settings. From the
Modems dialog you can:
FastLink II comes preconfigured with a list of the modems you are most likely to encounter. The settings for
each modem consist of a set of strings that FastLink II will use to operate that modem.
In most cases, you will not need to use the Modems dialog. All you’ll need to do is select the appropriate modem
in the Setup dialog and you’ll be up and running without any trouble. Even if your modem does not appear in the
list, there is likely to be another modem in the list that works the same way as yours.
To display the Modems dialog, check the Modems button at the left of the screen. A dialog similar to the
following appears:
Add a modem to the list of available modems
Remove a modem from the list of available modems
Edit the settings for any modem
Figure 7: Modems Dialog
44
How FastLink II Operates the Modem
FastLink II operates a modem based on the command string and result string settings for that modem:
When FastLink II initiates a call to a server, it first sends three command strings in succession: Reset, Init, and
Additional. It then sends the Dial string, followed by the phone number.
The Auto-answer string is only used for dialback. After making the initial connection, FastLink II hangs up,
sends the Reset, Init, and Additional strings, then sends the Auto-answer string to await the return phone call
from the server.
Command Strings
The modem command strings should perform functions as follows:
A command string is a string sent to the modem to cause it to perform an operation, such as to reset
itself, dial a number, or wait for a call.
A result string is a string sent back from the modem to indicate the result of an operation.
The Reset string resets the modem to the factory defaults.
The Init string should:
−−Configure error-correction and compression
−−Enable hardware flow control
−−Enable CD (Carrier Detect) high on connection
−−Enable hang-up on DTR (Data Terminal Ready) low.
−−Set the CONNECT report string to the modem’s DCE speed. This will show the true
speed of the connection.
The Additional string contains any additional initialization you’d like.
The Dial string contains the dial prefix sent before the phone number.
The Auto-answer string should put the modem in auto-answer mode.
45
Response Strings
The modem response strings have the following meanings:
Adding a Modem
When adding a modem to the list, you can save yourself a little time by first selecting a modem similar to the one
you want to add. The strings for your new modem will be initialized from the currently displayed strings, and
you’ll have less editing to do.
To add a modem to the list of modems:
1Press [Add]
The OK string is returned by the modem to indicate success. Ordinarily, this string is set to OK.
The Connect string is returned by the modem to indicate a successful connection. Ordinarily, this
string is set to CONNECT.
The Busy string is returned by the modem to indicate a busy phone line. Ordinarily, this string is set
to BUSY.
The No carrier string is returned by the modem to indicate it did not get an answer. Ordinarily, this
string is set to NO CARRIER.
The No dialtone string is returned by the modem to indicate it did not get a dialtone. Ordinarily, this
string is set to NO DIALTONE.
The Error string is returned by the modem to indicate some other error occurred. Ordinarily, this
string is set to ERROR.
and enter a name for the new modem when prompted.
The new modem will be added to the list, and its settings (based on the previously selected modem)
are displayed.
2Highlight each of the strings you’d like to change, and edit them to your liking.
3Press
The modem you added will now be available for selection in the Setup dialog.
to make your changes permanent.
[Save]
46
Removing a Modem
To remove a modem from the list:
1Highlight the Modem name drop-down box, and select the modem you’d like to remove.
2Press
[Remove]
Editing Modem Settings
To edit a modem’s command or result strings:
1Highlight the Modem name drop-down box, and select the modem whose settings you’d like to edit.
2Highlight each of the strings you’d like to change, and edit it to your liking.
3Press
[Save]
The Scripts Dialog
The Scripts dialog lets you create and edit scripts, which are used when you create FastLink II connections in the
Connections dialog. Scripts allow you to easily automate connections to a Remote Annex server with front-end
security.
NOTE: The Scripts dialog must be created from the Windows version of the FastLink II
interface; that is, from FLINKW.EXE run in Windows. In addition, scripting will only work
while you are running in Windows.
From the Scripts dialog you can:
to remove the modem from the list.
to make your changes permanent.
Add a script to the list of available scripts
Remove a script from the list of available scripts
Edit existing scripts by inserting, deleting, or rearranging the order of any of the script command
lines
47
FastLink II comes preconfigured with a Standard script, which works for many terminal servers and Internet
access providers.
To display the Scripts dialog, check the Scripts button at the left of the screen. A dialog similar to the
following appears:
Figure 8: Scripts Dialog
Adding a Script
To add a new script:
1Press
2Create a new script by adding script commands. See the section “Editing Scripts” below for a
3Press
The script you added will now be available for selection in the Connections dialog.
and enter a name for the new script when prompted.
[Add]
The new script will be added to the list, and the Script window will display the ---end of script ---
line
description of how script commands work.
to make your changes permanent.
[Save]
48
Removing a Script
To remove a script from the list:
1Highlight the Script Name drop-down box, and select the script you’d like to remove.
2Press
Editing Scripts
You can edit the selected script using the buttons to the right of the Script Window:
When you press [Ins] or [Edit] to insert or edit a command, the Script Command dialog will appear. This dialog
allows you to select a command and enter additional information required by the command, such as an argument
and options settings.
You'll notice that the Script Command dialog is an “active” one; the dialog controls automatically adapt to your
selection, and the Description box contains an explanation of the command you selected.
[Remove]
To insert a new script command, highlight the line at which you'd like to insert the new command,
then press [Ins].
To append a command to the end of the list, position the highlight to the ---end of script --- line,
then press [Ins].
To modify an existing script command, highlight the command and press [Edit], or double-click the
command line.
To remove a command from the script, highlight the command line and press [Del]
To move a command up or down in the script's execution order, highlight the command and click the
up or down arrow buttons
(
and )
to remove the script from the list.
49
For example, if you selected expect, entered “Login:” as the String, and checked the nocase option, you would
see the following display:
Figure 9: Script Command Dialog
When you press [OK], the command, argument, and option settings are formulated into a single script line and
placed in the script.
Script Commands
The following script commands can be inserted into your list:
Script CommandDescription
[-nocase]
expect
string
Wait until
string
then proceed.
If -nocase is specified, then upper and lower
case letters are treated equally when scanning
for
; otherwise, an exact match to
string
required.
prompt
[-secret]
string
Display a message with
wait for a reply. Your input will be stored as
response
(see
specified, asterisks are echoed.
NOTE: If you press
the script is aborted.
[-noreturn]
send
string
Transmit
string
carriage return is automatically appended to
, unless -noreturn is specified.
string
50
appears in the receive stream,
string
as a prompt, and
string
senditem
below). If -secret is
[Cancel]
during your input,
over the transmit stream. A
is
senditem
wait
time
timeout
[-noreturn]
time
item
Transmit
return is automatically appended to
-noreturn is specified.
The
item
response:
username:
connection
password:
connection, or the response to a password
prompt (if you selected Prompt for Password)
Wait until the specified
argument is entered as seconds, up to 3
time
decimal places.
Sets the script to fail with a timeout message if
elapses from the point at which this
time
command is encountered. The
entered as seconds, up to 3 decimal places.
When the script first starts, a timeout of 120
seconds (2 minutes) is used. The
command overrides any previous timeout.
The time during which a PROMPT command is
waiting for input is not included in the timeout
period.
over the channel. A carriage
item
string
can be any of the following:
the last response to a prompt
the username field from the current
the password field from the current
has elapsed. The
time
argument is
time
timeout
, unless
Displaying Port Statistics
FastLink II’s Port Statistics display provides statistics on data traffic to help diagnose any problems that you may
have. Note that the statistics are cleared each time you reload the FastLink II ODI driver, and they are
cumulative over all connection sessions.
Two types of statistic are shown: Packet Statistics and Character Driver Statistics.
Packet Statistics show success and error counts based on entire packets of data.
Character Driver Statistics show success and error counts on a per-character basis for the low-level
driver that operates the serial port.
51
To view the Port Statistics display, check the Port Statistics button at the left of the screen. A display similar
to the following appears:
Figure 10: FastLink II Statistics Screen
The following table describe these statistics.
52
StatisticMeaning
Character Driver Statistics
Rx totalTotal number of characters received
Rx errorsNumber of hardware receive errors (UART overrun
or framing error). If the ratio of
is worse than 1 in 10,000, consider reducing your
baud rate.
Rx buffer overrunsThe number of times the receive buffer could not
accept additional data. Indicates a cabling problem
or modem not responding to hardware flow control.
Rx flow offThe number of times that hardware flow control was
used to throttle receive data from the modem.
Tx totalTotal number of characters transmitted
Rx errors
Packet Statistics
Total packets sentTotal number of packets sent.
Total packets receivedTotal number of packets received.
Checksum errorsThe number of packets with invalid checksum,
indicating a data error.
Send packet too smallThe number of send packets smaller than the
minimum size.
Send packet too bigThe number of send packets larger than the
maximum size.
No ECB availableThe number of packets received for which no
application was listening. (This is not necessarily an
error condition.)
Receive packet overflowThe number of packets received for which no
internal buffer is available.
Receive packet too bigThe number of received packets larger than the
maximum size.
Receive packet too smallThe number of received packets smaller than the
minimum size.
Send packet miscellaneousThe number of send packets with hardware errors.
Receive packet miscellaneousThe number of receive packets with hardware errors.
Received mismatchesThe number of packets with invalid media headers.
(This should never happen.)
to
Rx total
53
Housekeeping
The Housekeeping dialog has additional functionality that you can use.
NOTE: The
interface; that is, from FLINK.EXE run from the DOS command line. This is because this test
must access hardware directly; this is best done when Windows is not running.
To bring up the Housekeeping menu, select Housekeeping from the FastLink II User Interface main menu.
The resulting display will look like this:
The Comm Port Test option displays a list of available serial ports and determines the UART type
for each.
Comm Port Test
must be performed from the DOS version of the FastLink II
Figure 11: FastLink II Housekeeping Dialog
54
The Comm Port Test
The Comm Port Test displays information about the serial ports that are available on your PC. To display this
information:
1From the main menu, select Housekeeping.
2From the Housekeeping menu, select Comm Port Test.
FastLink II surveys your serial ports and display the following information about each:
The resulting display will look like this:
The COM port number
The port’s I/O address
The type of UART (Universal Asynchronous Receiver-Transmitter) used.
Figure 12: FastLink II Comm Port Test Screen
55
FLINK.EXE Command Line Options
The FLINK.EXE command (the FastLink II DOS User Interface) offers several command line options that let
you:
Connect and disconnect without running the full-screen interface.
Run the Comm Port Test option without running the full-screen interface.
Specify monochrome rather than color operation, to improve the appearance of the full-screen
interface on certain gray-scale displays.
Connecting from the DOS Command Line
To connect without running the full-screen interface, just specify the name of the connection right on the
command line:
FLINK connectionname
For example, if you’ve created a connection called BRANCHOFFICE, you can connect to it by typing:
FLINK BRANCHOFFICE
Once the connection is established, information such as connection speed, data handling options, server name,
and the like will be displayed on screen.
↵↵
↵↵
Disconnecting from the Command Line
To disconnect without running the full-screen interface use the /D switch:
FLINK /D
↵↵
56
Running the Comm Port Test
To run the Comm Port Test from the command line, use the /T switch:
FLINK /T
Information about your serial ports will be displayed on screen.
↵↵
Displaying Port Statistics from the Command Line
To display FastLink II statistics from the DOS command line, use the /S switch:
FLINK /S
Complete Port Statistics information will be dumped to your screen, one line at a time. If you want to capture
statistics to a file, you can direct the FLINK output to a file. For example, to write your statistics to file
STATS.TXT you would type:
FLINK /S > STATS.TXT
↵↵
↵↵
Using Monochrome Mode
The FastLink II User Interface automatically adjusts to whether your display adapter is color or monochrome.
However, many laptops have gray-scale displays that represent different colors with various shades of gray.
Sometimes the result is that some have inadequate contrast or are indistinguishable from each other.
If you find such problems when you run the FastLink II User Interface, try specifying monochrome mode using
the /M switch:
FLINK /M
↵↵
FLINKW.EXE Command Line Options
The FLINKW.EXE command (the FastLink II Windows User Interface) offers several command line options
that let you:
The real power of the FLINKW.EXE command line is that you can create Windows icons that automate your
connections. The “Connecting From Windows” chapter discusses the types of procedures you might want to
automate and provides useful examples.
Connect and disconnect without running the full interface.
Automatically launch other programs or batch files after a connection has been established. For
example, you could automatically start a Proxy remote control session, or automatically log in to file
servers and map drives.
57
Connecting from the Windows Command Line
To connect from Windows without running the full interface, just specify the name of the connection right on the
command line:
FLINKW connectionname
For example, if you’ve created a connection called BRANCHOFFICE, you can connect to it as follows:
FLINKW BRANCHOFFICE
Disconnecting from the Command Line
To disconnect without running the full interface, just specify the /D switch:
FLINKW /D
↵↵
Automatic Program or Batch File Launch
When you run the FastLink II User Interface with a connection name on the command line, you can also specify
one or more programs to launch once the connection has been established.
The program or programs you wish to launch must be separated by the vertical bar character (“|”). Following
each vertical bar you may have a command line to launch a Windows or DOS program:
For example, to make a connection using connection name MYOFFICE, and then to run PROXY to remotely
control a PC called MYPC:
FLINKW MYOFFICE | PROXY MYPC
Macros for automatic program launch
Since you can string several command lines together to perform multiple operations from the FLINKW.EXE
command line, it is possible for the FLINKW.EXE command line to become too long. The macro capability
provides a way around this problem.
Macros are defined in the [AppNames] section of FLINK.INI. To create a macro, you must edit this file to add
an entry in the form:
macro=commandline
For example, to create a macro called RC to run PROXY to remotely control a PC named MYPC, you would
include the following within the [AppNames] section of FLINK.INI:
RC=C:\PROXY\PROXY.EXE MYPC
58
Then, you can use the macro rather than the PROXY command line after the vertical bar in the FLINKW
command line:
FLINK.INI Settings
The FLINK.INI file contains a [Settings] section with parameters that affect the programs’ operation. The
following table explains these parameters:
FLINKW MYOFFICE | RC
59
ParameterMeaning
ConnectNotify
DisconnectNotify
SuccessActionDetermines what to do with the FastLink II client if a
ConnectText
For command line connections only
or 1 (enable). If enabled, displays a message box with the
full connection information (name, connection speed,
whether compression or encryption were used, etc.). If
disabled, no message is displayed and no confirmation is
necessary.
For command line connections only
or 1 (enable). If enabled, displays a message box when
FastLink II is disconnected with the /D option. If disabled,
no message box is displayed.
successful connection is made from the user interface or
the command line. The default (0) is to have FLINKW
remain active in both cases.
For command line connections
1 FLINKW is minimized as an icon
2 FLINKW will terminate
For user interface connections,
10 FLINKW is minimized as an icon
20 FLINKW will terminate
Note that the command line and user interface options
are additive, e.g., if you set SuccessAction=21 then
FLINKW will terminate after a successful UI connection,
and minimize after a successful command line
connection.
SuccessAction operations occur after any application
launching and message box displays (e.g., if
ConnectNotify=1).
For all connections.
CONNECT.TXT file is created when a connection is
made. Set to 0 to not create the file, or 1 to create the
file.
Determines whether the
. Set to 0 (disable)
. Set to 0 (disable)
, set SuccessAction to:
add to SuccessAction:
60
Overview
II-3 Connecting from DOS
This chapter describes how to connect to the network from the DOS environment. It covers not only FastLink II,
but also the other TSRs and programs you need to build an IPX stack and login to NetWare file servers. You’ll
find out:
How to issue a series of commands at the DOS prompt to build an IPX stack, connect to a Remote
Annex server, then login to file servers.
How to automate the above sequence using a batch file.
How to use a local login script to speed up the login process.
How to tear down your remote connection, either by issuing commands from the DOS prompt or by
running a batch file.
How to use the optional FLCACHE TSR to guard against accidentally running DOS programs from
the network when you’d prefer to run them from your local hard disk.
Before you Connect
Before you connect make sure that:
You are not already connected to a LAN through a direct Ethernet or Token Ring connection.
You have the latest version of either NETX or VLM.
NOTE: If you use VLM, be sure you have at least version 1.11. Check README.TXT
for information on the latest versions of VLM and NETX.
You have local copies of Novell programs such as LOGIN, ATTACH, MAP and any other programs
that you may need.
FastLink II comes pre-configured with a connection named SAMPLE that dials a Remote Access server. If
you’d like, you can edit the SAMPLE connection to make a connection to a Remote Annex server for testing.
You’ve used the FastLink II User Interface Setup dialog to configure COM port settings, modem
information, and the like.
You’ve used the FastLink II User Interface Connections dialog to create a named connection with the
correct phone number to dial and other settings.
61
Making a Connection Manually
What follows is a step-by-step procedure that loads all the modules necessary to establish an IPX connection to
the network and then login to NetWare file servers.
If this is your first time connecting, it’s a good idea to go through this manual procedure to understand how it
works. In practice, you’ll want to use batch files to automate this process, as described in the next section.
Making an IPX Connection
To make the connection, perform the following from the DOS command prompt:
1Load LSL (the Link Support Layer):
↵↵
LSL
2Load the FastLink II ODI driver:
↵↵
FLODI
3Run
4Load the IPX protocol:
You now have an IPX connection to the network.
the FastLink II User Interface
FLINK connectionname
For example, to make connect to a remote access server, type:
FLINK SAMPLE
FastLink II initiates the connection, and notifies you when your PC is connected.
IPXODI
↵↵
↵↵
with the connection name on the command line:
↵↵
62
Loading the NetWare Shell
Before logging in to a NetWare server, you need to load either VLM or NETX, depending on which shell you
have installed on your PC.
The preferred shell to use is Novell’s VLM (Virtual Loadable Module manager). This shell provides improved
performance by transferring data in burst mode. NETX is Novell’s older shell program. While it works fine over
FastLink II, it lacks some of the features that the VLM shell has that are useful for remote access.
To use VLM, type:
↵↵
VLM
To use NETX, type:
↵↵
NETX
Logging In
Once you’ve loaded VLM or NETX, you can use the LOGIN command to login to a file server. From the DOS
prompt, type:
LOGIN servername/username
Then enter your password when prompted.
For example, to login to server BIGSERVER as user ALICE:
LOGIN BIGSERVER/ALICE
Your PC is connected to the server and you are now able to use all network services.
While connected, you can minimize delays by running programs from your local drive rather than from the file
server. It’s a good idea, for example, to ensure that your PATH environment setting lists local directories prior to
network directories.
Using a Local Login Script
When you use the LOGIN command to login to a NetWare file server, a login script is run. The login script may
attach to additional file servers, map drives and printers, and perform other functions that set up your networking
environment.
When using FastLink II, you may want to override your standard login script with a local login script. Your
standard login script might take a long time to run over a dial-up line; a short, well-designed local login script
can usually speed up the process considerably:
You can avoid the delay of transferring the server’s login script over the dial-up line.
↵↵
↵↵
63
You can eliminate functions you may not need. For example, there may be drives you don’t need to
map, file servers you don’t need to attach to, or printer ports you don’t need to capture.
To login using a local login script, use the following form of the LOGIN command:
The /S switch indicates that the item that follows is the pathname of a login script. For example, to log in to
server BIGSERVER as user ALICE, using local login script LOGIN.DAT:
Be sure to include the drive and full pathname of the local login script.
Creating a Local Login Script
Your FastLink II Administrator can help you set up a local login script.
Most login scripts consist primarily of ATTACH commands to connect to additional file servers, MAP
commands to create network drives, and CAPTURE commands to redirect printer ports to network printers.
Here’s an example of a simple login script:
ATTACH SERVER2/GEORGE
MAP J:=SERVER2/SYS:PUBLIC
#C:\FLINK\CAPTURE Q=PRINT_QUEUE NB TI=10 NFF
You can save time by running programs such as CAPTURE.EXE from your local hard disk rather
than from the file server.
LOGIN /S scriptpath servername/username ↵↵
LOGIN /S C:\FLINK\LOGIN.DAT BIGSERVER/ALICE ↵↵
Note in the example above that ATTACH and MAP are script commands that are directly interpreted by the
LOGIN program. There is no directly interpreted CAPTURE command however, so CAPTURE.EXE must be
run as a DOS program by using the # prefix. Note also that the drive and full pathname of the CAPTURE
program are supplied, to ensure that the program is run from the local hard disk.
64
Breaking the Connection
To break your connection, do the following from the DOS prompt:
1Log out from any NetWare file servers you are attached to:
LOGOUT
2Break the FastLink II connection to the Remote Annex server:
FLINK /D
You’ve now disconnected, but all modules are still loaded. If you’d like to reconnect, just re-establish your
FastLink II connection and log in again.
If you are done with remote access and you’d like to unload the NetWare shell and the IPX stack, continue as
follows:
3Unload the NetWare shell by typing either:
VLM /U ↵↵
or
NETX /U ↵↵
4Unload the IPX protocol:
IPXODI /U ↵↵
5Unload the FastLink II ODI driver:
FLODI /U ↵↵
6Unload LSL:
↵↵
↵↵
LSL /U ↵↵
65
Making and Breaking Connections with Batch Files
The procedures described above can easily be automated using batch files. For example, you could have a batch
file called DIALUP.BAT to automatically dial a Remote Annex server and login as GUEST:
is a small TSR that provides two benefits during your remote session:
It protects you against accidentally launching programs from the network, which take longer to load
over dial-in lines.
It lets you keep local copies of programs you normally run from the network, and automatically runs
the local copy even when the remote copy of the program is called for. You might use
NetWare utilities such as LOGIN, LOGOUT, MAP, etc.
FLCACHE
66
for
How FLCACHE Works
FLCACHE intercepts requests to run DOS programs from network drives, and prompts you either to run the
program, to download it, or to cancel the operation. By intercepting these requests, FLCACHE provides a
warning that you may be accidentally running a program over a relatively slow dial-up connection.
FLCACHE also allows you to specify a special cache directory on your local drive in which you can place
commonly run programs that normally reside on the network. You don’t have to change your AUTOEXEC.BAT
file’s PATH statement as a remote user; the cache directory is always checked first whenever there’s an attempt
to run a program from a network drive.
Sample FLCACHE Session
The following example explains how FLCACHE operates.
1You enter this command to run Novell’s WHOAMI utility:
WHOAMI
2FLCACHE responds with this message.
↵↵
File W:\PUBLIC\WHOAMI.EXE is 26 KB. Continue? Y)es N)o
D)ownload
This message means that FLCACHE detected that WHOAMI.EXE is located on the network drive. It
then prompts you whether you want to run or download the program.
3You then respond by entering this command to download WHOAMI.EXE to your file cache
directory on your local drive:
↵↵
D
From now on, whenever you run WHOAMI, it automatically runs from the cache directory on your local drive.
67
Configuring FLCACHE
FLCACHE has command-line options to allow you to customize its operation. This command follows this
syntax.
FLCACHE <option list>
The following table explains these options.
OptionMeaning
/LSpecifies the directory containing local copies of remote programs.
The default is the FLCACHE directory off the current directory
/UUnloads FLCACHE from memory
/SSets the file size threshold in kilobytes. Smaller files will be loaded
normally over the network. Default: /S=5
/DDisables FLCACHE notification
/EEnables FLCACHE notification after using /D
/WProvides the warning only. No caching is done. Reduces TSR
overhead somewhat. '/L' option not allowed
/?Displays available options
68
Overview
II-4 Connecting from Windows
This chapter describes how to connect to the network from the Windows environment. It covers not only
FastLink II, but also the other TSRs and programs you need to build an IPX stack and login to NetWare file
servers. You’ll find out:
How to issue a series of commands in DOS to load the proper drivers prior to running Windows.
How to use the FastLink II User Interface from Windows to make and break connections to a Remote
Annex server.
How to use Novell’s NetWare User Tools program to log in and out of file servers, map drives, and
capture printers.
How to create powerful Windows icons that automate the process of connecting to a Remote Annex
server and setting up your networking environment.
69
Before You Connect
Before proceeding make sure that:
Note that FastLink II comes pre-configured with a connection named SAMPLE that dials a remote access server.
If you’d like, you can connect to that server as a test. Check the FastLink II User Interface Connections dialog in
case you need to make changes to the SAMPLE connection. For example, you might need to include a PBX
prefix or international country code in the phone number.
You are not already connected to a LAN through a direct Ethernet or Token Ring connection.
You’ve installed the VLM version of the Novell’s NetWare Client. If you requested Novell NetWareFiles during installation, this will be done for you automatically.
You’ve used FastLink II’s Setup dialog to configure COM port settings, modem information, and the
like.
You’ve used FastLink II’s Connections dialog to create a named connection with the correct phone
number to dial and other settings.
Before Running Windows
If you requested Novell NetWare Files installation, then the last line of your AUTOEXEC.BAT should be:
CALL C:\FLINK\LOADVLM
This will load all the required drivers you need to run FastLink II from Windows. If you don’t have this line in
your AUTOEXEC.BAT, you can invoke LOADVLM.BAT with the following command:
LOADVLM ↵↵
Alternatively, you can load each driver manually. For information on doing this, refer to the next section
“Loading the NetWare VLM Stack.”
Loading the NetWare VLM Stack
To load the NetWare stack, type the following from the DOS command prompt:
1Load LSL (the Link Support Layer):
↵↵
LSL
2Load the FastLink II ODI driver:
↵↵
FLODI
70
3Load the IPX protocol:
IPXODI ↵↵
4Load VLM (the Virtual Loadable Module manager):
VLM ↵↵
Now, you can start Windows and use FastLink II to make connections.
Connecting to the Remote Access Server
To connect to a Remote Annex server from Windows:
1Run the FastLink II User Interface (FLINKW.EXE) by double-clicking the FastLink II Client icon.
The FastLink II Connection dialog appears.
2Select a connection from the Connection drop-down box.
3Press
To disconnect from the Remote Annex server, just press [Disconnect] from the Connection dialog.
[Connect]
. FastLink II will establish a connection to the Remote Access server.
Connecting to NetWare File Servers
Once you have made a FastLink II connection, you can log into NetWare file servers, map drives, capture
printers, then log out when you’re done. All these operations can be performed from Novell’s NetWare User
Tools (NWUSER.EXE).
To log into a NetWare file server:
1From NetWare User Tools, click the NetWare Connections icon or press
Connections dialog will appear.
2Under the Resources column, select the NetWare file server you want to access, then press
3Enter your NetWare user name and password.
To map drives:
1From NetWare User Tools, click the Drive Connections icon or press
Connections dialog will appear.
[Alt-C]
[Alt-D]
. The NetWare
. The Drive
[Login]
.
71
2Select a drive from the Drives column and a file server from the Resources column, then press
.
[Map]
To capture printers:
1From NetWare User Tools, click the Printer Connections icon or press
Connections dialog will appear.
2Select a printer port from the Ports column and a print queue from the Resources column, then press
[Capture]
To log out of a NetWare file server:
1From NetWare User Tools, click the NetWare Connections icon or press
Connections dialog will appear.
2Under the Connections column, select the currently attached NetWare file server you want to log out
of, then press
.
[Logout]
.
Using Custom Windows Icons
This section describes several types of icons that you can create to automate the process of connecting and
establishing a networking environment.
These icons use the FLINKW.EXE command line for connecting to a Remote Annex server and launching
programs or batch files once connected. See the section “FLINKW Command Line Options” in the “FastLink II
User Interface” chapter for a description of how these options work.
FastLink II’s Windows installation creates a Software group with several samples of such icons:
[Alt-P]
[Alt-C]
. The Printer
. The NetWare
Dial Sample — Dials a Remote Annex server using the SAMPLE connection.
Dial Sample & Guest Login — Dials Remote Annex server, logs in to the network, and maps drives.
Dial & Proxy — Connects to a Remote Annex server and starts a Proxy Remote Control session.
The following sections show how to create your own icons, using these samples as guides.
Creating an Icon that Establishes a Connection
The following procedure shows how to create an icon similar to the Dial icon in your Software program group.
This icon automatically connects to a FastLink II server using a connection name.
Follow these steps:
72
1Use Program Manager’s File New command to create a new Program Item in the group of your
choice.
2Set the Command Line field to run the FastLink II User Interface and specify a connection name as
an argument. For example, to create a FastLink II icon that uses the DIAL connection, you would
enter:
C:\FLINK\FLINKW.EXE SAMPLE
3Click
and the new icon is ready for use.
[OK]
Creating an Icon that Connects and Logs In
The following procedure shows how to create an icon similar to the Dial & Guest Login icon in your Software
program group. This icon automatically connects to a Remote Annex server using the connection name, then
runs a batch file in a DOS box to log in to a NetWare file server.
In order for this to work, your system must be set up so that when you log in or map a drive in a DOS box, you
do so “globally” and affect the entire system, not just the one DOS box. To make sure that this is the case, run
NetWare User Tools (NWUSER.EXE), click the NetWare Settings icon or press [Alt-S], and make sure the
Global Drives & Path box is checked. If not, check it and restart Windows so this change will take effect.
To create the icon, follow these steps:
1If you don’t already have one, create a local login script that attaches to servers, maps drives, and
otherwise sets up your networking environment.
NOTE: Local login scripts are discussed in the chapter “Connecting From DOS.”
2Create a DOS Batch (.BAT) file that logs you into the network and give it a descriptive name (such
as MYLOGIN.BAT).
The first line must make your first network drive the current drive. (Check the FIRST NETWORK
DRIVE setting of your NET.CFG file for the appropriate drive letter.) This is really just a trick to
“wake up” VLM and let it make its initial attachment to the first server it sees.
The second line should contain the LOGIN command you require, which would include the name of
a local login script, the name of a file server, and your user name.
The following is an example of a batch file that logs in to server TEST as user GUEST and uses a
local login script GUEST.DAT:
F:
C:LOGIN /S C:\FLINK\GUEST.DAT TEST/GUEST
73
3Using the PIF Editor, create a .PIF file to execute the DOS batch file you just created. Use the same
name as your batch file; for example, if your batch file is MYLOGIN.BAT you could call your .PIF
file MYLOGIN.PIF. Set the following options:
PIF Editor OptionSetting
Program FilenameThe name of your batch file (e.g.,
MYLOGIN.BAT)
Display UsageWindowed
ExecutionBackground
Close Window on ExitChecked
4Use Program Manager’s File New command to create a new Program Item in the group of your
choice.
5Set the Command Line field to run the FastLink II User Interface with a connection name as an
argument, followed by a vertical bar and the name of the .PIF file you just created.
74
For example, to create a FastLink II icon that uses the DIAL connection and then runs a batch file
specified in MYLOGIN.PIF, enter the following in the Command Line field:
C:\FLINK\FLINKW.EXE SAMPLE | C:\FLINK\MYLOGIN.PIF
6Click OK and the new icon is ready for use.
Creating an Icon that Runs Proxy
The following procedure shows how to create an icon similar to the Dial Sample and Proxy icon included in
your FastLink II program group. This icon connects to a Remote Annex server, then launches a Proxy Remote
Control session.
To create this icon:
1Use Program Manager’s
choice.
2Set the Command Line field to run the FastLink II Windows User Interface with a connection name
as an argument, followed by a vertical bar and a PROXY command line to run after successful
connection.
For example, to create a FastLink II icon that uses the SAMPLE connection and begins a Proxy
session with a host named DEMO, enter the following in the Command Line field:
File New
command to create a new Program Item in the group of your
C:\FLINK\FLINKW.EXE SAMPLE | PROXY DEMO
3Click OK and the new icon is ready for use.
75
II-A FastLink II Connection
Errors
Connection Error Messages
The following messages may appear on screen when your system encounters an error, either while trying to
establish a connection, or while connected.
77
Error MessageMeaningAction
Modem error:
Busy
DisconnectedThe modem disconnected
Modem error:
invalid command
Error: Crossed
connection
Error: No
FastLink II Server
License Available
Error: Not
Universal
FastLink II Client
Error: Unable to
access Remote
Access Server
Database
Forced by
administrator
Invalid
configuration
The line is busy.Try the call again.
before completing PPP
negotiation.
The modem returned an
error message.
The hardware is echoing
data sent by the client.
All available licenses on
the server are in use.
You are not authorized to
connect to a non-Bay
Networks server.
There has been an error
accessing the server
database.
The system administrator
forced a termination of the
connection.
The client and server failed
to agree on PPP
negotiation parameters.
Check the modem configuration and
try the call again. If the error
persists, contact the system
administrator.
Check the modem configuration and
try the call again. If the error
persists, contact the system
administrator.
Check the hardware and modem
configuration.
Try the call again later.
Are you running the PPP Client,
instead of the FastLink II Client?
Contact the system administrator.
Contact the system administrator.
Contact the system administrator.
78
Error MessageMeaningAction
Invalid or
duplicate node
address
Invalid or missing
IP Address
Modem Error:
No carrier
Modem Error:
No dialtone
No network
protocols
enabled
Not a dial-in portThe server terminated the
TimeoutThe client timed out
Unable to
negotiate data
link
UnknownThere was an unknown
User requestYou explicitly
Someone has called in
with a duplicate node
address.
You have requested a
dynamic IP address which
the server is unable to
provide
The modem is unable to
connect, or unable to
negotiate with the
answering modem’s
protocols.
There is no dialtone; there
may be a problem with
your local connection.
You have not connected
with either an IPX or an IP
protocol
connection attempt
because it is not
configured to allow dial-in
at this port.
waiting for the modem to
connect.
The client timed out during
PPP negotiation.
error on the line.
disconnected.
Generate a new Client random node
address. If this fails, contact the
system administrator.
Contact the system administrator to
provide additional IP addresses
Check the modem configuration and
try the call again. If the error
persists, contact the system
administrator.
Check your modem and your
telephone line.
Check your IPX and IP protocol
settings. If you have requested IPX
and/or IP, the remote access server
may not be properly configured for
the requested protocol.
Contact your system administrator.
Possible modem problem. Check
your modem configuration.
Ask the administrator to check your
configuration
Try the call again.
79
Introduction
FastLink II supports the following IP stacks:
Information on installation and configuration of these stacks with FastLink II is provided in this document.
III-1 Supported IP Stacks
Beame & Whiteside (BW-TCP 3.2)
Frontier (Super/TCP 4.0 R2)
FTP (OnNet v2.1 for Windows)
Microsoft (Windows for Workgroups 3.11)
NetManage (Chameleon 4.01)
Novell (LAN Workplace for DOS/Windows 4.2, 5.1)
Wall Data (Rumba for Internet 1.0)
Wollongong (Pathway Access 3.1)
WRQ (Reflection 2, 4.01)
81
Beame & Whiteside (BW-TCP 3.2)
ProductBW-TCP 3.2
CompanyBeame & Whiteside
Address706 Hillsborough St.
1Run the standard BW-TCP installation. Follow the standard installation instructions.
2When asked to supply Driver Type, respond ODI.
3Now, configure your stack based on whether you want a static or dynamic IP address. Follow the
instructions for "Static IP Address Configuration" or "Dynamic IP Address Configuration" below.
82
Static IP Address Configuration
Configuring BW-TCP for a static IP address requires configuring both BW-TCP and FastLink II for the same
static IP address.
To configure BW-TCP for a static IP address:
1Run the BW-TCP configuration utility by clicking on the Customize icon in the BW-Apps Windows
group.
2Click [OK] in the BW Customization Program dialog box.
3In the dialog box entitled BW-TCP Customization Menu, enter the IP address of your gateway in the
Default Gateway field.
4Set the Netmask field to your IP subnet mask.
5Enter your static IP address in the IP Address field.
6After you make your changes press [Save].
To configure FastLink II for a static IP address:
1Run FastLink II, and select the Connections button at the left of the screen. Highlight the Connect
drop-down box, and select the connection whose settings you want to set for your IP connection.
2Click on the [IP Protocol Settings] button, and check the Static IP address button.
3Highlight the Address field and enter your static IP address.
83
Dynamic IP Address Configuration
Configuring BW-TCP for a dynamic IP address requires BOOTP or RARP protocol; for this stack, we
recommend RARP. FastLink II should be configured for dynamic IP address.
To configure BW-TCP for RARP:
1Run the BW-TCP configuration utility by clicking on the Customize icon in the BW-Apps Windows
group.
2Click [OK] in the BW Customization Program dialog box.
3In the dialog box entitled BW-TCP Customization Menu, delete any value in the Default Gateway
field.
4Set the Netmask field to 0.0.0.0.
5Use the Arrow Box in the IP Address field to select the value: RARP.
6After you make your changes press [Save].
7After making your changes, you must reboot your machine for them to take effect. First, however,
you may wish to do the FastLink II configuration for dynamic addressing.
To configure FastLink II for a dynamic IP address:
1Run FastLink II, and select the Connections button at the left of the screen. Highlight the Connect
drop-down box, and select the connection whose settings you want to set for your IP connection.
2Click on the [IP Protocol Settings] button, and check the Dynamic IP address button.
To use RARP and dynamic addressing, you must connect in DOS (not in Windows) prior to running
STARTNET, which the stack install will have placed in your AUTOEXEC. See "System File Requirements"
for more information.
84
System File Requirements
Your AUTOEXEC.BAT (or the file you use to load your network stack) should contain lines like these:
C:\FLINK\LSL
C:\FLINK\FLODI
C:\BEAME\STARTNET
However, if you are going to use dynamic addressing (and RARP protocol), you must defer execution of
STARTNET until you have connected. So the necessary sequence is to execute LSL and FLODI, then use
FLINK to connect. Once you are connected, you may then execute STARTNET prior to invoking Windows.
In addition, verify that the SET DOMAIN statement in the AUTOEXEC.BAT is correctly pointing to your
domain. If your domain were XYZ.COM, this statement should read
SET DOMAIN XYZ.COM
85
Frontier (SuperTCP for Windows)
ProductSuperTCP for Windows, version 4.0 R2
CompanyFrontier Technologies, Inc.
Address10201 N. Port Washington Road
Mequon , WI 53092
Telephone+1 414 241 4555
Technical Support Telephone+1 414 241 4555
Installation Directions
Frontier Technologies Corporation. - SuperTCP for Windows version 4.00
To configure SuperTCP do the following:
1Run the standard SuperTCP installation. Follow the standard installation instructions.
2Configure your stack based on whether you want a static or dynamic IP address (see instructions
below).
3When asked to supply Driver Type, respond ODI.
4At the end of the install, the SetupTCP configuration utility will be launched. You will be prompted
for configuration information, however, you must manually select Next Hop Always and the DefaultGateway. Follow the instructions for "Static IP Address Configuration" or "Dynamic IP Address
Configuration" below.
NOTE: If you have a version of SuperTCP prior to March 1995, you need to apply the
WINSOCK9.ZIP patch release (dated 2/2/95) available from Frontier Technologies. This patch
fixes RARP functionality, along with a number of other improvements. It also removes the need
to run the ODIPKT driver, thus simplifying the running of the stack.
86
Static IP Address Configuration
Configuring SuperTCP for a static IP address requires configuring both SuperTCP and FastLink II for the same
static IP address.
To configure SuperTCP for a static IP address:
1Run the SuperTCP configuration utility by clicking on the SetupTCP icon in the SuperTCP
Windows group
2Select the Interfaces icon in the left-hand side list box.
3Set the IP Address Type by selecting the Fixed radio button.
4Enter your static IP address in the IP Address field.
5Enter your IP subnet mask in the IP Address Mask field.
6Select the IP Setup icon in the left-hand side list box.
7Enter your remote access server gateway address in the Default Gateway field.
8Check the box labeled Always Use Default Gateway As Next Hop.
9After you make your changes press [Close].
To configure FastLink II for a static IP address:
1Run FastLink II, and select the Connections button at the left of the screen. Highlight the Connect
drop-down box, and select the connection whose settings you want to set for your IP connection.
2Click on the [IP Protocol Settings] button, and check the Static IP address button.
3Highlight the Address field and enter your static IP address.
87
Dynamic IP Address Configuration
Configuring SuperTCP for a dynamic IP address requires BOOTP or RARP protocol; BOOTP provides you with
the most flexibility and is what we recommend. FastLink II should be configured for dynamic IP address.
To configure SuperTCP for BOOTP:
1Run the SuperTCP configuration utility by clicking on the SetupTCP icon in the SuperTCP
Windows group.
2Select the Interfaces icon in the left-hand side list box.
3Set the IP Address Type by selecting the BOOTP radio button. The BOOTP Server Address field
will display 255.255.255.255, and the Subnet Mask field will display 255.255.255.0.
4After you make your changes press [Setup], then press [Close].
NOTE: If you previously configured SuperTCP for a Fixed IP Address, you need to
remove its matching Hosts Table entry. Select the
side list box, select the
To configure FastLink II for a dynamic IP address:
1Run FastLink II, and select the Connections button at the left of the screen. Highlight the Connect
drop-down box, and select the connection whose settings you want to set for your IP connection.
Fixed IP
entry, and press the
Hosts Table
[Cut]
icon in the left-hand
button.
2Click on the [IP Protocol Settings] button, and check the Dynamic IP address button.
88
System File Requirements
Make sure that your NET.CFG file contains the following Link Driver FLODI section lines:
Link Driver FLODI
Frame Ethernet_II
Protocol IP 800 Ethernet_II
Protocol ARP 806 Ethernet_II
Protocol RARP 8035 Ethernet_II
Make sure that your AUTOEXEC.BAT (or the file you use to load your network stack) contains lines similar to
this:
SET TZ=est5edt
SET SUPERTCP=C:\WINDOWS\SUPERTCP.INI
C:\FLINK\LSL
C:\FLINK\FLODI
89
FTP (OnNet v2.1 for Windows)
ProductOnNet v2.1 for Windows
CompanyFTP Software, Inc.
Address2 High Street
North Andover, MA 01845
Telephone+1 508 685 4000
Technical Support Telephone+1 508 685 4000
Installation Directions
FTP Software, Inc. - OnNet v2.1 for Windows
To install OnNet, or configuring an existing installation of OnNet, do the following:
1Make sure that you have loaded the FastLink II driver (FLODI) into memory from the DOS prompt.
If you need to load FastLink II, exit Windows, run FLODI from the FastLink II directory, and then
run Windows again.
2Run the standard OnNet installation. Follow the standard installation instructions.
3In the Found existing driver dialog choose:
ODI, FLODI
4In the Network Type dialog chose:
DIX Ethernet
5Setup will then ask for your IP address information.
6Follow the instructions for "Automatic IP Address Configuration" below.
90
Automatic IP Address Configuration
When using FTP Software OnNet version 1.2 or 2.1, FastLink II will automatically set the workstation IP
address, the network mask, and the router address when it connects to the remote access server.
To ensure that this works, you need to configure OnNet for dummy static IP addresses (which will later be
updated) as follows:
1Run the OnNet configuration utility.
-- From DOS, run CONFIG.EXE from the PCTCP directory
-- From Windows, click on Configure in the OnNet group
2Choose Internet Addresses.
3Enter your static IP address in the IP Address field.
4Enter your IP subnet mask in the Subnet Mask field
5Enter your remote access server gateway address in the Router field.
Static IP Address Configuration
Since FastLink II will replace the OnNet IP stack values at connect time, it is not normally required to use a
Static IP address.
To configure FastLink II for a static IP address:
1Run FastLink II, and select the Connections button at the left of the screen. Highlight the Connect
drop-down box, and select the connection whose settings you want to set for your IP connection.
2Click on the
3Highlight the Address field and enter your static IP address.
Dynamic IP Address Configuration
Since FastLink II will replace the OnNet IP stack values at connect time, you normally will use FastLink II
dynamic IP configuration.
To configure FastLink II for a dynamic IP address:
1Run FastLink II, and select the Connections button at the left of the screen. Highlight the Connect
drop-down box, and select the connection whose settings you want to set for your IP connection.
2Click on the
[IP Protocol Settings]
[IP Protocol Settings]
button, and check the Static IP address button.
button, and check the Dynamic IP address button.
91
System File Requirement
Make sure that your AUTOEXEC.BAT (or the file you use to load your network stack) contains lines similar to
this:
SET PCTCP=C:\PCTCP\PCTCP.INI
C:\FLINK\LSL
C:\FLINK\FLODI
C:\PCTCP\ODIPKT
C:\PCTCP\ETHDRV (for DOS applications)
or
C:\PCTCP\VXDINIT (for Windows applications)
Make sure that your NET.CFG contains the statement:
Link Driver FLODI
92
Microsoft TCP/IP-32 3.11 (WFW 3.11)
ProductTCP/IP-32 3.11
CompanyMicrosoft Corporation
AddressOne Microsoft Way
Redmond, WA 98052
Telephone+1 206 882 8080
Technical Support Telephone+1 206 882 8080
Installation Directions
Microsoft Corporation - TCP/IP-32 3.11 (Windows for Workgroups 3.11)
TCP/IP-32 3.11 supports TCP/IP for Windows for Workgroups, version 3.11 only. To install TCP/IP-32 do the
following:
1Run Network Setup from the Network group in WFW.
2Get to the Drivers section and select your network card. Select [Add Protocol] to add the TCP/IP
protocol (which may be obtained from Microsoft).
3Follow the instructions for "Static IP Address Configuration" below.
Windows for Workgroups' TCP/IP-32 supports only static IP addressing.
93
Static IP Address Configuration
Configuring TCP/IP-32 for a static IP address requires configuring both TCP/IP-32 and FastLink II to use the
same static IP address.
NOTE: Before you setup WFW for TCP/IP support, you must already have configured Windows
for Workgroups for basic network connectivity. If you have not done this, refer to your WFW
documentation, or the README.TXT file supplied with FastLink II.
To configure TCP/IP for a static IP address:
1If TCP/IP-32 has already been installed, run Network Setup from the Network group in WFW.
2In the Network Setup dialog box, select the Microsoft TCP/IP-32 3.11 line, and click on the
Drivers Button.
3In the Network Drivers dialog box, select the Microsoft TCP/IP-32 3.11 line, and click on the
Setup Button.
4In the Microsoft TCP/IP dialog box, enter your static IP address in the IP Address field.
5Enter your IP subnet mask in the Subnet Mask field
6Enter your remote access server gateway address in the Default Gateway field.
To configure FastLink II for a static IP address:
1Run FastLink II, and select the Connections button at the left of the screen. Highlight the Connect
drop-down box, and select the connection whose settings you want to set for your IP connection.
2Click on the [IP Protocol Settings] button, and check the Static IP address button.
3Highlight the Address field and enter your static IP address.
94
System File Requirements
Make sure your NET.CFG contains these lines:
Link Driver FLODI
Frame Ethernet_II
Note that FastLink II will not work properly if any frame statement other than Frame Ethernet_II appears after
the Link Driver line.
Make sure your AUTOEXEC.BAT (or the file you use to load your network stack) contains lines like these:
C:\FLINK\LSL
C:\FLINK\FLODI
Windows for Workgroups is guided by a path statement in PROTOCOL.INI, when it seeks the location of your
NET.CFG. If you change the directory in which you place your NET.CFG and execute LSL, you must alter the
path in PROTOCOL.INI.
If you execute LSL from C:\FLINK, for example, PROTOCOL.INI would have lines like these:
[NET.CFG]
PATH=C:\FLINK\NET.CFG
PROTOCOL.INI should also contain these lines:
[LINK DRIVER FLODI]
data=Frame Ethernet_II
data=Link Driver FLODI
NOTE: Any time you reconfigure using the
you should check your resulting NET.CFG and PROTOCOL.INI files. Check for new frame
statements that may disable FastLink II.
Network Setup
icon in Windows for Workgroups,
95
NetManage (Chameleon 4.01)
ProductChameleon 4.01
CompanyNetManage, Inc.
Address10725 North De Anza Blvd
Telephone:+1 408 973 7171
Technical Support Telephone+1 408 973 7171
Installation Directions
NetManage, Inc.. - ChameleonNFS
To install Chameleon do the following:
1Make sure that you have loaded the FastLink II driver (FLODI) into memory from the DOS prompt.
If you need to load FastLink II, exit Windows, run FLODI from the FastLink II directory, and then
run Windows again.
Cupertino, CA 95014
2Run the standard Chameleon installation. Following installation, the configuration utility will be
launched, which is the equivalent of clicking on "Custom" in the ChameleonNFS Windows group.
3Follow the instructions for "Static IP Address Configuration" or "Dynamic IP Address Configuration"
below.
NOTE: When
settings for you to fill in. However, it does not prompt for the
Server
Custom
. Make sure that you enter information for these fields.
is executed in the Install sequence, it brings up a number of dialog box
Default Gateway
or
Domain
96
Static IP Address Configuration
Configuring Chameleon for a static IP address requires configuring both Chameleon and FastLink II for the
same static IP address.
NOTE: Make sure that you have loaded the FastLink II driver (FLODI) into memory from the
DOS prompt before proceeding. Otherwise, you will have to manually configure the driver type
to ODI in the
To configure Chameleon for a static IP address:
1Click on the "Custom" icon in the ChameleonNFS Windows group.
2Select Setup, and then IP Address choice from the pulldown menu.
3Enter your static IP address in the IP Address field.
4Enter your IP subnet mask in the Subnet Mask field
5Enter your remote access server gateway address in the <Gateway> field.
To configure FastLink II for a static IP address:
1Run FastLink II, and select the Connections button at the left of the screen. Highlight the Connect
Hardware
drop-down box, and select the connection whose settings you want to set for your IP connection.
pulldown in
Setup
.
2Click on the [IP Protocol Settings] button, and check the Static IP address button.
3Highlight the Address field and enter your static IP address.
97
Dynamic IP Address Configuration
Configuring Chameleon for a dynamic IP address requires configuring BOOTP protocol. FastLink II should be
configured for dynamic IP address.
NOTE: Make sure that you have loaded the FastLink II driver (FLODI) into memory from the
DOS prompt before proceeding. Otherwise, you will have to manually configure the driver type
to ODI in the
To configure Chameleon for BOOTP:
1Click on the "Custom" icon in the ChameleonNFS Windows group.
2Click on the BOOTP on the Setup pulldown menu. Leave the address 0, and check the "Use
To configure FastLink II for a dynamic IP address:
1Run FastLink II, and select the Connections button at the left of the screen. Highlight the Connect
2Click on the [IP Protocol Settings] button, and check the Dynamic IP address button.
System File Requirements
Hardware
BOOTP" box.
drop-down box, and select the connection whose settings you want to set for your IP connection.
pulldown in
Setup
.
Make sure that your NET.CFG file contains the following Link Driver FLODI section lines:
Link Driver FLODI
frame ethernet_ii
Make sure that your AUTOEXEC.BAT (or the file you use to load your network stack) contains lines similar to
this:
ProductLAN Workplace 4.2 and 5.1
CompanyNovell, Inc.
Address122 East 1700 South
Provo, UT 84606
Telephone+1 800 NETWARE
Technical Support Telephone+1 800 NETWARE
Installation Directions
Novell, Inc. - LAN Workplace Version 4.2 and 5.1
To install the LAN Workplace stack you can use the FastLink II client install and select the
Stack
option.
If you install the LAN Workplace product (which includes TCP/IP applications), or to configure an existing
installation of LAN Workplace, do the following:
1Run the standard LAN Workplace installation. Follow the standard installation instructions.
2When asked to identify the IPX Frame Format, respond
requires.
3Install creates an initializing batch file called LANWP.BAT, which it runs from your
AUTOEXEC.BAT. See the instructions under
modifications to that file.
4To customize the installation, you will need to edit the NET.CFG file to configure the stack for static
or dynamic IP address (see instructions below).
Ethernet_II
System File Requirements
. This is the frame FastLink
Novell TCP/IP
, below, for needed
99
Automatic IP Address Configuration
FastLink II will automatically set the workstation IP address, the network mask, and the router address when it
connects to the remote access server.
To ensure that this works, you need to configure LAN Workplace for dummy addresses (which will later be
updated) as follows:
1Look for the "Protocol TCPIP" section in the NET.CFG:
Protocol TCPIP
PATH TCP_CFG C:\NET\TCP
ip_router 127.0.0.1
ip_netmask255.255.255.0
ip_address 127.0.0.1
2Edit any existing configuration lines for ip_router, ip_netmask, and ip_address from the TCPIP
section to contain any values (use the values above to show dummy values); make sure that the
values are not 0.0.0.0.
Static IP Address Configuration
Since FastLink II will replace the LAN Workplace IP stack values at connect time, it is not normally required to
use a Static IP address.
To configure FastLink II for a static IP address:
1Run FastLink II, and select the Connections button at the left of the screen. Highlight the Connect
drop-down box, and select the connection whose settings you want to set for your IP connection.
2Click on the
3Highlight the Address field and enter your static IP address.
Dynamic IP Address Configuration
Since FastLink II will replace the LAN Workplace IP stack values at connect time, you normally will use
FastLink II dynamic IP configuration.
To configure FastLink II for a dynamic IP address:
1Run FastLink II, and select the Connections button at the left of the screen. Highlight the Connect
drop-down box, and select the connection whose settings you want to set for your IP connection.
2Click on the
[IP Protocol Settings]
[IP Protocol Settings]
button, and check the Static IP address button.
button, and check the Dynamic IP address button.
100
System File Requirements
Make sure LANWP.BAT contains lines like these (FLODI must be loaded prior to TCPIP):
C:\FLINK\LSL
C:\FLINK\FLODI
C:\LANWP\BIN\TCPIP.EXE
The directory where LSL is executed must be the same directory where your NET.CFG is located. The
NET.CFG built by the stack install program is sometimes placed in an NWCLIENT subdirectory underneath the
stack root directory. Move the NET.CFG to the FastLink II directory.
Make sure your NET.CFG contains the following lines (in addition to the Protocol TCPIP lines generated by the
stack install):
Link Driver FLODI
Frame Ethernet_II
After configuring LAN Workplace, make sure you reference the correct NET.CFG file (i.e., use the version in
the FastLink II directory).
101
Wall Data (Rumba for Internet 1.0)
ProductRumba for Internet 1.0
CompanyWall Data
Address11332 N.E. 122nd Way
Kirkland, WA 98034
Telephone+1 800 927 8622
Technical Support Telephone+1 800 927 8622
Installation Directions
Wall Data (Rumba for Internet 1.0)
To configure RUMBA do the following:
1Run the RUMBA installation, and follow the standard installation instructions.
2When prompted for your adapter driver enter the name of the FastLink II ODI driver using the
whole path as in the following line:
C:\FLINK\FLODI.COM
NOTE: Make sure you provide the full path name, or the installation will not work properly.
3Configure your stack based on whether you want a static or dynamic IP address (see instructions
below).
102
Static IP Address Configuration
Configuring RUMBA for a static IP address requires configuring both RUMBA and FastLink II for the same
static IP address.
To configure RUMBA for a static IP address:
1Run the RUMBA configuration utility by clicking on the TCP/IP Configuration icon in the
RUMBA Windows group.
2Click on [Stack] in the TCP/IP Configuration dialog box.
3In the dialog box entitled MultiNet Configuration click on [Modify].
4Set the Subnet Mask field to your IP subnet mask.
5Enter your static IP address in the IP Address field.
6Make sure the Enable Interface box is checked, and that your Driver Choice is set to ODI.
7Make sure your Gateway is addressed by clicking on the Routing tab in the MultiNet Configuration
dialog box. Enter the gateway address in the Default Route field.
8After you make your changes press [Done].
To configure FastLink II for a static IP address:
1Run FastLink II, and select the Connections button at the left of the screen. Highlight the Connect
drop-down box, and select the connection whose settings you want to set for your IP connection.
2Click on the [IP Protocol Settings] button, and check the Static IP address button.
3Highlight the Address field and enter your static IP address.
103
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.