Introduction:
Thank you for choosing the Ascensia®BREEZE™ Diabetes Care System! We are proud to be your partner in helping you to manage your diabetes. We understand that people who regularly check their blood glucose levels want a meter that is simple, straightforward and easy to use. As you use your Ascensia®BREEZE™ System, you will appreciate the:
• Ease of running a test, and discarding a used test strip.
• Use of a 10-Test Disc—which means no individual test strips to fumble with.
• User-friendly design—buttons make recalling your results or setting the time as easy as making a telephone call.
• Ease of recalling a 14-Day Average.
This ease of use comes with the added bonus of the reliability that you count on from Bayer.
This user guide shows you how to use your Ascensia
®
BREEZE™ Diabetes Care System. It will answer any questions you might have and guide you through the testing process. It is here to help you!
This User Guide is divided into two sections. Part 1 — Everyday Use will guide you through the basic use of the meter. Part 2 — Beyond Everyday Use will guide you through special features—such as how to change the time and the date, or where to find more help with this product.
i
Fold this page out for easy reference when using your user guide.
A look at your Ascensia B
REEZE Meter…
On/Off Button:
Use this button to manually turn the
meter On or Off.
Data Port:
(side of meter) Insert cable here to allow communication between meter and a personal computer.
Screen: This is
where your test results will be displayed.
Release Button:
Press to release
and discard
used test strip.
Meter Handle:
Use this handle to
push out a test
strip and
automatically turn
on the meter.
Button Door:
Open to expose meter buttons.
Battery Holder:
(side of meter)
Holds one CR2025
lithium battery.
ii
Simply place the easy reference sticker on the Button Door as shown. See sheet of stickers provided in your meter package and select the language of your choice.
On/Off Button:
Use this button to manually turn the
meter On or Off.
Memory Button:
Use this button to
view your blood
glucose results
stored in memory
and to view your
14-day average.
Set-Up Button:
Use this button to
enter the Set-Up
mode and easily
change the time,
date or other
features.
Up/Down Buttons:
Use these buttons with the Memory button to see your results or use with the Set-Up button to change the time, date, etc.
Accept (OK) Button:
Use this but­ton to accept changes made in the Set-Up mode.
iii
(Button door open)
iv
Release Button
Test Strip Slot
Open Latch
(back of meter) Press in and pull up to open meter.
Meter Handle
Testing Materials:
10-Test AUTODISC (Contains ten test strips.)
Normal Control Solution
M
ICROLET
®
Adjustable
Lancing Device and Lancet
Important Information:
Caution: Before using any product to test your blood glucose, read all instructions carefully and practice the test.
A full display, as shown here, indicates that all characters in the display are working properly. To view the full display, pull the meter handle all the way out. Compare your meter to the display shown here. If there is a difference, please see Troubleshooting page 44.
v
1
Table of Contents:
Everyday Use
Inserting a 10-Test AUTODISC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Running a Blood Glucose Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Running a Control Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Beyond Everyday Use
Recalling Test Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Setting Time, Date and Other Features . . . . . . . . . . . . . . . . . . . . . . . 19
Transferring Test Results to a Computer . . . . . . . . . . . . . . . . . . . . . . 26
Cleaning Your Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Replacing the Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Te chnical Information
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Performance Evaluations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Multiple Site Testing Evaluation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Solving Problems
Solving Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Troubleshooting and Error Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Customer Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Replacement Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
5-Year Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
The Ascensia®BREEZE™Diabetes Care System (meter, test strips and controls) is intended for self-testing by persons with diabetes, and by healthcare professionals, to monitor the level of glucose in whole blood. The Ascensia®BREEZE™System is specific for glucose and has been referenced to plasma/serum glucose.
INSERTING A 10-TEST AUTODISC:
WARNING: Never open
the meter with the meter handle pulled out.
Open Meter
1. Hold the meter with the display screen down. Open the meter by pressing down on the back edge of the open latch and then pulling the front cover up.
2.Open the new 10-test disc
package. Check the expiration date on the disc.
2
Everyday Use
Insert Disc
3.Insert a new 10-test
disc—yellow arrow (bumpy side) up. The arrow may point in any direction.
Close Meter
4.Close the meter and
snap it shut. Keep the
meter flat.
J
Helpful Hint: The meter must be kept flat when closing. If the meter is not kept flat, the disc may move and become damaged and you may waste test strips.
3
Counting Number of Strips Left
Your Ascensia®BREEZE™ Meter will automatically count down the number of test strips you have left.
To see this count when the meter is off, press the button.
Note: This count is reset to 10 every time you open the meter. To keep an accurate count, open the meter only when all 10 of the test strips have been used in the 10-test disc.
Your meter will also tell you when you need to insert a new 10-test disc. It will do this by showing you a picture of a disc being inserted into the meter.
4
RUNNING A BLOOD GLUCOSE TEST:
1.Wash your hands well with soap and
warm water. Rinse and dry thoroughly.
2.Remove the endcap from the
M
ICROLET
®
Adjustable Lancing
Device. (See M
ICROLET
®
Device package insert for complete instructions.)
3.Insert lancet firmly until it comes to a full stop. This will “cock” the device.
5
4.Twist off lancet cap and replace the endcap.
Push out Test Strip
Caution: Your meter is designed to push out one test strip at a time. Do not attempt to push out a new test strip with one already showing.
5.Your Ascensia
®
BREEZE™ Meter was designed with a special, easy-to-use “Pull and Push” design. Here’s how it works:
Hold the meter comfortably in one hand. Firmly grasp the
Meter Handle with the other hand (shown here). Now, just “Pull and Push”“Pull” the handle out until it stops and
“Push” it back in until it stops again.
6
Note: This will automatically turn your meter on if it is not al­ready on. For regular, everyday use you don’t have to worry about turning it on—just “Pull and Push.”
Note: The release button is UP, a test strip
is pushed out and a flashing blood drop appears on the screen. The meter is now ready to run a blood glucose test.
6.Stick your finger with the M
ICROLET
®
Device and form a small round drop of blood.
7
Te st
7.Your test strip is like a straw; it sips in a sample of blood. Move the entire front edge of the test strip to touch the edge of the blood drop. The blood is automatically pulled into the test strip and fills the test strip.
Hold the test strip in place until the meter beeps, and three dashes appear on the screen, then move it away. By doing this, you will make sure the test strip is completely filled.
8
8.While the meter calculates your blood glucose level, you will see a sequence of dashes on the screen.
After 30 seconds, your test result will appear on the screen.
9
9.To release the used test strip, hold the meter with the test strip pointing down over a waste container. Press the release button. Make sure the heel of your hand is not against the meter handle.
Note: If you block the meter handle with your hand, the test strip may not release properly.
10.Press the button to turn the meter off. If you forget to turn your meter off, the meter will turn
off automatically after three minutes. This will save battery power.
Caution: If your glucose result is below 2.8 mmol/L (50 mg/dL), above 13.9 mmol/L (250 mg/dL) or if the meter shows “HI” or “LO,” test again. If your glucose level is still below 2.8 mmol/L (50 mg/dL), above 13.9 mmol/L (250 mg/dL), or if the meter again shows “HI” or “LO,” it may indicate a potentially serious medical condition.
If this is the case: We recommend you consult your
physician or healthcare professional immediately.
Caution: Any changes in medication based on Ascensia
®
BREEZE™ blood glucose results without the advice of a physician or healthcare professional is not recommended.
10
For best results:
•Blood is pulled IN the test strip not dropped ON.
• Do not allow blood to run down into the meter.
•Do not add more blood after the meter beeps.
11
Loading...
+ 38 hidden pages