Baxtran STI User Manual

STI
USER MANUAL
EN
V.2.2
18/10/2018
| marca propiedad de | est une marque de | trade mark propiety of | ist als Marke des Markeneigentums zu kennzeichnen |marchio proprietà di
Pol. Empordà Internacional Calle F. Parcela 15-16
El fabricante se reserva el derecho de modificar sin previo aviso las características de sus productos para introducir mejoras técnicas o cumplir con nuevas regulaciones oficiales./Le constructeur se réserve le droit de modifier les caractéristiques de ses produits en vue d’y apporter des améliorations techniques ou de respecter de nouvelles réglamentations./The manufacturer reserves the right to modify the specifications of its products in order to make technical improvements or comply with new regulations/ Der Hersteller behält sich das Recht vor, ohne Vorankündigung die Eigenschaften seiner Produkte zu ändern, um weitere Verbesserungen zu erzielen oder neuen offiziellen Richtlinien nachzukommen/ Il fabbricante si riserva il diritto di modificare senza alcun preavviso le caratteristiche dei suoi prodotti in vista di apportare migliorie tecniche o di rispettare nuove regolamentazioni.
T. (34) 972 527 212 - F. (34) 972 527 211
ENUSER MANUAL STI
EN
CONTENTS
1. PRECAUTIONS 4
2. INTRODUCTION 5
2.1 COMPONENTS 5
3. SPECIFICATIONS 5
3.1 GENERAL SPECIFICATIONS 5
3.2 PRINTER SPECIFICATIONS 6
3.3 OVERALL VIEW 6
3.4 CONNECTORS 7
3.5 DIMENSIONS 7
4. INSTALLATION 8
5. KEY BOARD & DISPLAY 9
6. OPERATION 11
6.1 POWER ON/OFF 11
6.2 ZERO 11
6.3 TARE 12
6.4 SAMPLE WEIGHING 12
6.5 SELECT UNIT 12
6.6 PLU SETTINGS 13
6.6.1 USING DIRECT PLU 13
6.6.2 USING INDIRECT PLU 15
6.7 BACK LIGHT 17
6.8 AUTOMATIC UNIT PRICE CLEAR 17
6.9 ACUMULATION 17
6.10 GIVE CHANGES 18
6.11 SALES REPORT 19
6.12 PAPER ROLL INSTALLATION 20
7. PARAMETERS 21
7.1 PARAMETER SETTINGS 21
7.2 PARAMETER MENU 22
8. CALIBRATION 24
9. RS 232 OUTPUT 24
10. PRINT FORMAT 27
11. ERROR CODES 28
12. DRAWING 30
13. DOWNLOAD SOFTWARE 31
2
ENUSER MANUAL STI
3
1. PRECAUTIONS
ENUSER MANUAL STI
WARNING
DISCONNECT ALL POWER TO THIS UNIT BEFORE
INSTALLING, CLEANING, OR SERVICING. FAILURE TO
DO SO COULD RESULT IN BODILY HARM OR DAMAGE
THE UNIT.
CAUTION
• PERMIT ONLY QUALIFIED PERSONS TO SERVICE THE INSTRUMENT
• BEFORE CONNECTING OR DISCONNECTING ANY COMPONENTS, REMOVE THE POWER.
• FAILURE TO OBSERVE THESE PRECAUTIONS BODILY HARM OR DAMAGE TO OR DESTRUCTION OF THE EQUIPMENT.
• The price computing scale is a precision electronic instrument, handle it carefully.
• Do not install the scale in direct sunlight.
• Verify the local voltage and receptacle type are correct for the scale.
• Only use original adaptor, other could cause damage to the scale.
• Pluggable equipment must be installed near an easily accessible socket outlet.
• Avoid unstable power sources. Do not use near large users of electricity such as welding equipment or large motors.
• Avoid sudden temperature changes, vibration, wind and water.
• Avoid heavy RF noise.
• keep the scale clean
4
2. INTRODUCTION
2.1. COMPONENTS
STI series of economic price computing scales are very compact, reliable high accuracy and much stable
It uses 18mm/9.5mm LCD display with white LED back light
Accumulation, weighing unit conversion and change function
33 membrane keyboard
8 direct PLUs and 100 indirect PLUs, supported alphanumeric PLU information
4 direct keys for vendors
Auto unit price clear operation
With back office software to manage product information and sale repor t
AC Adaptor / Rechargeable battery
Built-in 58mm thermal receipt printer, easy to load paper
3. SPECIFICATIONS
ENUSER MANUAL STI
3.1. GENERAL SPECIFICATIONS
MODEL
Display
Capacity 6g 15g 30g
Readability 2g 5g 10g
Max. Divisions 3000e
Weighing Units kg / 100g
Pan size 240x370mm
Housing ABS Plastic and stainless steel pan
Communication Interface RS232; RJ11 as standard port.
Operation Temperature -10°C -+ 40°C
Stability Time 1 Seconds typical
Power
Keypad 33 membrane keys
ADC Sigma delta
Front and Pole: 18mm/9.5mm LCD Display
AC Adaptor 12V/2500mA.
standard rechargeable Battery 6V/4Ah
LPP
LED back Light
Internal counts 600,000
Gross Weight 7kg
5
3.2 PRINTER SPECIFICATIONS
Printing Method Thermal dot line printing
Number of dots/line 384
Dots density 8
Printing width (mm) 48 (centered on paper)
Paper width (mm) 57
Paper roll size (mm) 50
Printing Resolution 203DPI
Printer Head Life 50kilometer
Printer Speed 90mm/second
3.3. OVERALL VIEW
ENUSER MANUAL STI
Client display
Pole
SST Pan
Level bubble Display Printer Keyboard
Calibration switch
Adjustable foot
Adaptor jack
6
3.4. CONNECTORS
1 2
No Interface Description Spec
1 RS 232 For computer, ECR or TPuP printer Standard
2 RJ11 Support Cash drawer(6V) Standard
3.5 DIMENSIONS
ENUSER MANUAL STI
7
4. INSTALLATION
UNPACKING
Carefully take the scale out of its package, make it sure its not damaged and all accessories are included.
Accessories:
1. Scale
2. Adaptor
3. Stainless steel pan
4. Product manual
Keep the packaging material for your future use.
LEVEL ADJUSTING
Place the scale on a table. Check the water mark. If bubble is not centre, adjust the leveling feet until reach centre. Check the level when you change the location.
ENUSER MANUAL STI
CONECT ADAPTOR
• To charge the battery insert the adaptor pin to jack. Adaptor simply plug into the mains power.
The scale no needs to be turned on.
• The battery should be charged for 4 hours for full capacity.
• The symbol status of the battery
Battery voltage has dropped
Fully charged
• Do not use any other type of power adaptor than the one supplied with the scale.
• Verify that the AC power socket outlet is properly protected
INSTALLATION
Place the scale on a table.
• Insert the pole into the bottom bracket.
• Close the bottom cover by using screws
• Carefully place the pan to the four holes on the top cover
• Adjust the water mark bubble level.
• Connect the adaptor pin to the adaptor jack.
Adaptor jack is locating below the right side of the scale.
8
• Adaptor connects into your AC power socket.
PANTONE 7541
B/L
COPY
U
JKL
DEFABC
PQRS
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
7
8
4
1
0
2
5
DEFABC
WXYZTUV
MNOGHI
3
6
9
T
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
Pluggable equipment must be installed near an easily accessible socket outlet with a protective ground/ earth contact.
• Turn on the power switch. If you want to turn off, press again the switch backward.
• Display will be show the scale capacity and will be starting self checking.
• After self checking, display will be come to normal weighing mode.
• Then you can start your operation.
Note: Initial Start Up.
Warm-up time of 15 minutes stabilizes the measured values after switching on.
5. KEYBOARD DISPLAY
ENUSER MANUAL STI
STI
V1 V2 P1 P2 P3 P4
V3 V4 P5 P6 P7 P8
SAVE
T
kg
100 g
V1
V2
V3
V4
COPY
7
4
1
0
PLU
TOTAL
M
B/L
PQRS
_( )
MEM
+
8
5
2
SAVE
U
JKL
MR
9
6
3
CE
WXYZTUV
T
DEFABC
MNOGHI
CLEAR RECORDS
KEYS PRESS THIS KEY TO
9
_( )
CE
to
CLEAR RECORDS
DEF
Numeric Keys, enter unit price / PLU and enter alphabetic characters in the corresponding menus.
Clear incorrect entries and error conditions. By keeping it pressed allows us to erase all records.
Returns the display to zero.In parameter settings,to escape from the menu. By long pressing enter to amount operation.
T
Subtracts the tare values, change to gross to net mode and enter parameter settings. By keeping it pressed allows us to enter a pre-tare.
9
ENUSER MANUAL STI
U
T
JKL
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
8
2
5
B/L
COPY
U
SAVE
T
JKL
DEFABC
PQRS
_( )
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
7
8
4
1
0
2
5
B/L
COPY
MEM
PLU
U
SAVE
T
MR
JKL
DEFABC
PQRS
_( )
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
7
8
4
1
0
2
5
U
SAVE
T
JKL
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
8
2
5
U
U
JKL
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
8
2
5
PANTONE 7541
B/L
COPY
MEM
PLU
U
SAVE
T
JKL
DEFABC
PQRS
_( )
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
7
8
4
1
0
2
5
100 g
kg
V1
V2
V4
V3
SAVE
T
P2 P3 P4
B/L
COPY
MEM
PLU
U
SAVE
T
M
+
TOTAL
MR
JKL
DEFABC
PQRS
_( )
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
7
8
4
1
0
2
5
100 g
kg
V1
V2
V4
V3
SAVE
T
PANTONE 7541
B/L
COPY
MEM
PLU
U
SAVE
T
JKL
DEFABC
PQRS
_( )
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
7
8
4
1
0
2
5
STI
100 g
kg
V1
V2
V4
V3
SAVE
T
V2 P1 P2 P3 P4
PANTONE 7541
B/L
COPY
MEM
PLU
U
SAVE
T
M
+
TOTAL
MR
JKL
DEFABC
PQRS
_( )
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
7
8
4
1
0
2
5
STI
100 g
kg
V1
V2
V4
V3
SAVE
T
P5 P6 P7 P8
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
B/L
COPY
U
JKL
DEFABC
MNO
6
9
7
8
5
DEFABC
9
T
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
SAVE
PLU
TOTAL
COPY
M
MEM
MR
U
Enter to auto clear mode.
By keeping it pressed allows us enter in the report print.
- Used for store or recall PLU information. (Long Touch)
- Used for select indirect PLUS (One Touch)
+
Used for give change operations. (First we must select the vendor).
Management of accounts in process.
- Used for change unit (kg/100g)
- Used for set back light (Long touch)
B/L
- Used for take a ticket copy (One Touch)
Used for switch on/off the scale
P1
V1
KEYS IN THE PARAMETER SETTINGS
4
10
GHI
to
to
to
Decimal point
P8
V4
T
6
MNO
8 direct PLU,used for store or recall PLU information
4 direct keys for select vendor.
To enter into the function and parameter settings
Scroll to function or parameter
Returns the display to zero.In parameter settings,to escape from the menu.
DISPLAY OVERLAY
PANTONE 7541
STI
T
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
DISPLAY SYMBOLS
ENUSER MANUAL STI
Net Net Weight.
Zero
/Kg /100g Current unit weight.
SAVE Save Indicator.
Tare Tare indicator.
Battery indicator. When it’s illuminated, battery should be
Stable indicator. When it’s illuminated, the scale is stable.
Zero indicator. When it’s illuminated, the scale is in Zero point.
recharge.
6. OPERATION
INITIAL START-UP
Warm-up time of 15 minutes stabilizes the measured values after switching on.
6.1 POWER ON/OFF
Switch on the scale by pressing the key again.
6.2 ZERO
Environmental conditions can lead to the balance exactly zero in spite of the pan not taking any strain. However, you can set the display of your balance to zero any time by pressing
key. The display is switched on and the self test is started. If you want to switch off, press
key and therefore ensure that the weighing starts at zero
11
6.3 TARE
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
The weight of any container can be tared by pressing weighed is always displayed.
Load weight on the pan.
ENUSER MANUAL STI
T
key, so that with subsequent weighing the net weight of the object being
• Press
T
key. Zero is displayed, and tare is subtracted.
Remove weight from the platform. Tared weight is displayed. It can set only one tare value. It can display with a minus value.
• Press
key. Zero is displayed, tare weight is cleared.
T
6.4 SAMPLE WEIGHING
Place goods to be weighed on the platform.
Wait few seconds for stability display.
Read the result.
Avoid overloading. When display appears “ol” reduce the load or unload.
6.5 SELECT UNIT
Press
U
key, It can select to kg for kilogram / 100g for gram weighing mode. When change the unit, unit indicator will be shown
in unit price display.
UNIT PRICE SETTINGS
Make sure platform is empty and display is zero
Weight
Unit price
Total price
0 000
0000
0 000 0 000
Place goods to be weighed on the platform.
Weight
Unit price
Total price
0 175
0000
0 000 0 000
Enter the unit price by pressing numeric keys.
Total price will be calculate automatically.
12
ENUSER MANUAL STI
PANTONE 7541
B/L
COPY
MEM
PLU
U
SAVE
T
JKL
DEFABC
PQRS
_( )
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
7
8
4
1
0
2
5
100 g
kg
V1
V2
V4
V3
SAVE
T
P2 P3 P4
B/L
COPY
MEM
PLU
U
SAVE
T
MR
JKL
DEFABC
PQRS
_( )
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
7
8
4
1
0
2
5
U
SAVE
T
JKL
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
8
2
5
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
B/L
COPY
U
JKL
DEFABC
MNO
6
9
7
8
5
DEFABC
9
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
Weight
Unit price
Total price
0 175
0000
5 000 0 88
6.6 PLU SETTINGS
STI has 8 direct and 100 indirect PLU, supported alphanumeric PLU information. It includes product name, weight mode, unit price, pre-tare.
6.6.1 USING DIRECT PLU
SAVE TO MEMORY
Enter product name
P1
Press and hold the direct
Weight
Unit price
SET
0000
PNAME
key, The display will show:
Total price
{__} Will be blink, press numeric keys to input product name. Press
For Ex: Press keys are for apple.
Weight
Unit price
Total price
Select product weight mode
Press
Weight
Unit price
Total price
Select product mode for amounting or weighting by using
Press
SET
APPLE
PNAME
T
key to confirm display will be Show weight mode:
weight mode
Amol-ht
T
key to confirm.
4
TOTAL
+
M
or
MR
key to shift location.
6
or
MNO
keys.
13
GHI
Set unit price
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
PANTONE 7541
B/L
COPY
MEM
PLU
U
SAVE
T
JKL
DEFABC
PQRS
_( )
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
7
8
4
1
0
2
5
100 g
kg
V1
V2
V4
V3
SAVE
T
P2 P3 P4
Display will be show:
ENUSER MANUAL STI
Weight
SET
UNIT PRICE
Unit price
0 00
Total price
Press numeric keys to input UNIT PRICE and press
Set pre-tare
Display will be show:
Weight
SET
PRE-TARE
Unit price
0 00
Total price
Press numeric keys to input PRE-TARE and press
Set tax
T
key to confirm.
T
key to confirm
Display will be show:
Press 1,2 or 3 numeric keys for select TAX A,B or C
RE-CAL PLU INFORMATION
When you want to weigh stored PLU content:
Press
Weight
Unit price
Total price
Which unit PLU information is stored.
Place the load on the platform, total price will be calculated automatically.
14
SET
ELECT - VAT 1
P1
, display will be shown
0 000 APPLE 000 0 00
0 00
6.6.2 USING INDIRECT PLU
B/L
COPY
U
SAVE
T
JKL
DEFABC
PQRS
_( )
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
7
8
4
1
0
2
5
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
B/L
COPY
MEM
PLU
U
SAVE
T
MR
JKL
DEFABC
PQRS
_( )
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
7
8
4
1
0
2
5
U
SAVE
T
JKL
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
8
2
5
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
SAVE TO MEMORY
Enter product name
PLU
Press and hold the
MEM
key, the display will be show set PLU:
ENUSER MANUAL STI
Weight
Unit price
SET
PLU
Total price
Press numeric keys to select the location you want to store
Weight
Unit price
SET
PLU 01
Total price
T
Press
key to confirm.
{__} Will be blink, press numeric keys to input product name,
TOTAL
+
press
M
or
MR
key to shift location.
Weight
Unit price
Total price
For Ex: Press keys are for apple.
Weight
Unit price
Total price
Select product weight mode
Press
Weight
Unit price
Total price
T
SET
PNAME
SET
APPLE
PNAME
key to confirm display will be Show weight mode:
HEIGHT MODE
AmoL-ht
15
ENUSER MANUAL STI
B/L
COPY
U
JKL
DEFABC
MNO
6
9
7
8
5
DEFABC
6
9
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
B/L
COPY
U
SAVE
T
JKL
DEFABC
PQRS
_( )
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
7
8
4
1
0
2
5
Select product mode for amounting or weighting by using
T
Press
key to confirm
Set unit price
Display will be show:
Weight
Unit price
SET
UNIT PRCE
0 000
Total price
T
Press numeric keys to input UNIT PRICE and press
Set pre-tare
Display will be show:
4
GHI
or
key to confirm.
MNO
keys
Weight
Unit price
SET
PRE TARE
0 000
Total price
Press numeric keys to input PRE-TARE value and press
Set tax
Display will be show:
SET
ELECT - VAT 1
Press 1,2 or 3 numeric keys for select TAX A,B or C
RE-CAL PLU INFORMATION
When you want to weigh stored PLU weighment, Press PLU information is stored.
T
key to confirm.
PLU
MEM
, display will be shown which
16
Weight
Unit price
Total price
SELECT
PLU
Input PLU number ,the display will be show PLU information.
Place the load on the platform, total price will be calculated automatically.
ENUSER MANUAL STI
U
B/L
COPY
U
JKL
DEFABC
MNO
6
9
7
8
5
DEFABC
9
U
T
JKL
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
8
2
5
PANTONE 7541
B/L
COPY
MEM
PLU
U
SAVE
T
JKL
DEFABC
PQRS
_( )
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
7
8
4
1
0
2
5
STI
100 g
kg
V1
V2
V4
V3
SAVE
T
V2 P1 P2 P3 P4
PANTONE 7541
B/L
COPY
MEM
PLU
U
SAVE
T
M
+
TOTAL
MR
JKL
DEFABC
PQRS
_( )
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
7
8
4
1
0
2
5
100 g
kg
V1
V2
V4
V3
SAVE
T
P5 P6 P7 P8
Weight
APPLE
Unit price
Total price
0 175 0000 5 000
0 88
6.7 BACK LIGHT
STI have an option to choose the back light operation.
When in normal weighing mode, Press and hold
Weight
Unit pice
Total price
Press the
4
SET
btmode Auto
GHI
or
6
MNO
keys to change the settings back light display mode to Auto / Manual /Off
COPY
B/L
key until to show the display
DISPLAY DESCRIPTION
SET BT MODE AUTO
SET BT MODE ON
SET BT MODE OFF
6.8 AUTOMATIC UNIT PRICE CLEAR
LPP can set automatic unit price clear.
Press
When save indicator on, unit price appear after return to zero.
When save indicator off, unit price will be clear automatically.
6.9 ACCUMULATION
The scale can be set to accumulate manually by pressing from to use.
Backlight will be turned on, when start to use or when weight is more than 20d.(when weight is less than 20d,the backlight will be off after a second)
Backlight stays on permanently.
Backlight function will be turned off
SAVE
key to save indicator turn on or off.
to
V4
key, depending on the seller that we want
V1
17
NON- WEIGHING ACCUMULATOR OPERATION
T
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
B/L
COPY
MEM
PLU
U
SAVE
T
MR
JKL
DEFABC
PQRS
_( )
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
7
8
4
1
0
2
5
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
Using numeric keys to input unit price or select PLU by pressing direct PLU key or by pressing.
ENUSER MANUAL STI
Weight
APPLE 0000
Unit price
Total price
Press and hold
Weight
Unit price
Total price
0,000
5 00 0 00
, key the display willl be show.
o 0
APPLE 0000
5 00
0. 00
Enter the number of pieces and the Total price will be calculated automatically.
6.10 GIVE CHANGE
TOTAL
+
Press
M
Key and select the desired vendor.
18
Displays will be show summation price
Weight
Unit price
Total price
2. 63 PAY
0. 00
By pressing numeric keys enter the amount, which is given customer.
Weight
Unit price
Total price
2. 63 PAY
3. 00
T
Press
Key to confirm, remaining scale
will be show in total price display.The payment details will be printed out and then return weighing mode.
Weight
Unit price
Total price
CHANGE
0. 37
ENUSER MANUAL STI
U
SAVE
T
JKL
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
8
2
5
U
JKL
DEFABC
WXYZ
MNOGHI
3
6
9
8
5
U
DEF
9
DEFABC
WXYZTUV
MNOGHI
3
6
9
U
T
JKL
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
8
2
5
B/L
COPY
U
JKL
DEFABC
MNO
6
9
7
8
5
DEFABC
9
DEFABC
WXYZTUV
MNOGHI
3
6
9
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
RECALL SALES LIST
After accumulating the list ,press
MR
key, it can check sales list one by one by pressing
If we want to delete any line from the scales list we just press the
6.11 SALES REPORT
SAVE
Press and hold
Weight
Unit price
Total price
4
By pressing
Total repor t: Will print the total sales by products.
Vat report: Wil print the total sales rates.
key, display will be show:
REPORT
Total
6
or
MNO
keys, Total repor t or Vat report can be selected. It allows the user to print the reports.
GHI
CE
CLEAR RECORDS
key.
2
TUV
or
8
ABC
keys.
REMOVE ALL RECORDS
CE
CLEAR
Once memory is full or no need to keep old records, It can select to remount record all by pressing
RECORDS
key.
Display will be show:
Weight
Unit price
Total price
REMOVE
ALL RECORD
T
Press key
to confirm
All sales memory will be clear. And display will be show:
Weight
PLEASE WAIT
Unit price
Total price
5 EMPTY
19
6.12 PAPER ROLL INSTALLATION
1
ENUSER MANUAL STI
2
3 4
5
1.Press the button to open the printer cover;
2. Open the printer cover;
3. Load paper rolls;
4. Pull the paper outside of the printer cover and press both side to close correctly cover;
5. Pull the paper towards the tear bar from one side to the other
20
7. PARAMETERS
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
B/L
COPY
U
JKL
DEFABC
MNO
6
9
7
8
5
DEFABC
9
T
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
7.1 PARAMETER SETTINGS
ENTER INTO THE MENU
T
Turn on the scales. Press Display will show Pin. Press the Pin number to get into the parameter menu.
The default PIN number is “9999”
Press numeric key 9 four times
T
• Press
key to confirm, it will enter into the parameter settings and will to show “FO CAL
ENTER TO SELECTED MENU
T
• Press
to confirm, it can confirm which will be shown displayed
key during the self test.
ENUSER MANUAL STI
SELECT THE MENU
4
• Press
6
or
MNO
It can choose menu block one by one
GHI
RETURN TO WEIGHING MODE
Press
escape from the menu and exit to weighing mode
ACTIVE ALL PARAMETERS
NOTE: to access the parameters marked with an asterisk it is necessary to press the switch placed
!
under the keyboard, in the inferior part of the equipment before pressing the key
T
to access. This
one is protected by a seal. Breaking the seal the verification is lost.
Press CAL switch to enable parameters for to access and change any parameter. CAL switch is locating bottom of the scale
21
7.2 PARAMETER MENU
ENUSER MANUAL STI
MENU
F0 CAL *
F 1 r ES *
F 2 CAP *
F 3 CLOCK
CLOCK STYLE Set the date format
SUB MENU DESCRIPTION
Calibration. See the calibration section
dUAL int Erv 3000 6 KG 15 KG 30 KG DATE TIME
COM 1
CHANEL
Pt YPE
bAUD
CHANEL
Rs232
PSEND
OFF 1200
2400
4800
9600
19200
38400
115200 RJ45
OFF
WIFI
Set external resolution
Set scale capacity
Set the date
Set the time
Com function selection
Download PLU information to the scale or receive PLU and report information from the back office software via RS232 Continuous data transmission
RS232 function disable
Set baud rate
Com function selection
22
F4 PCOM
COM 2
COM 3 *
Pt YPE
BAUD
Pt YPE
BAUD
PSEND
OFF
1200
2400
4800
9600
19200
38400
115200
TPUP
OFF 1200
2400
4800
9600
19200
38400
115200
Download PLU information to the scale or receive PLU and report information from the back office software via RJ45/WIFI
Com function disable
Set baud rate
Turn on the printer (Built-in printer)
Turn off the printer
Set baude rate
ENUSER MANUAL STI
F5
SET HT
F5
SET HT
F6 *
A2n
F7
PDECI
F8 *
PAY
F9 *
Minim
F10 *
GRA
F11
TAX
HERDE 1 HERDE 2 HERDE 3 HERDE 4 FOOTE 1 FOOTE 2 ON OFF 0
0.0
0.00
0.000 ON
OFF
2D
20d
BRANCH NAME
SCALE NAME
TAX NAME
Set header 1 content for print out
Set header 2 content for print out
Set header 3 content for print out
Set header 4 content for print out
Set footer 1 content for print out
Set footer 2 content for print out
Set Zero tracking function.
Set the price decimal.
Set pay function
Set minim weight function.
Set the local gravity
Enter the names of department,
scale and tax.
F12
T-CURR
F13
LANGUE
TAX TYPE
TAX WAY
TAX USER
EUR
CUSTOM
USD
FRENCH
PORTUG
ENGLISH
SPAIN
A, B or C
Include, exclude or no tax
Default or ask
For currency selection
For language selection
23
8. CALIBRATION
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
DEFABC
CLEAR RECORDS
WXYZTUV
MNOGHI
CE
3
6
9
NOTE: to access the parameters marked with an asterisk it is necessary to press the switch placed
ENUSER MANUAL STI
!
under the keyboard, in the inferior part of the equipment before pressing the key one is protected by a seal. Breaking the seal the verification is lost.
T
Turn on the scale. Press key
during the self test.
Display will show “Pin”. Press the PIN number to get into the parameter menu
The default PIN number is “9999”
Press numeric key 9 four times.
T
• Press
key to confirm, It will enter into the parameter settings and will to show “
Press Cal switch.
T
• Press
key to confirm for calibration, display will be show “
UNLOAD
Remove the goods from the platform and make sure STABLE indication has been enable.
T
• Press
key to confirm.
Display will be show the calibration weight
If necessary change the calibration weight value by pressing numeric keys
LOAD
Press key to confirm ,the display will be show “
CAL F0
”.
T
to access. This
Place the calibration weight on the platform, press
when display gets stable,display will be show “
PASS
key to confirm .
Once finished the calibration,the scale will be self-test and go back to the weighing mode.
9. RS S232 OUTPUT
1. SPECIFICATIONS
RS-232 output of weighing data ASCII code 1200~115200 Baud 8 data bits No Parity
2. RS-232 (9PIN D TYPE CONNECTOR)
24
T
ENUSER MANUAL STI
Pin 2
Pin 3
Pin 5
RXD Input
TXD Output
GND -
9PIN D CONNECTER:
Scale Computer
Pin 2 Pin 3
Pin 3 Pin 2
Pin 3 Pin 5
3. CONTINUOUSLY OUTPUT PROTOCOL
HEADER1: ST=STABLE US=UNSTABLE HEADER2: NT=NET GS=GROSS, WEIGHING UNIT:KG
Stable data communication
Receiving data
Transmission data
Signal ground
S T , G S : - +/- k
-HEADER 1- -HEADER 2- - WEIGHT DATA - -WEIGHT UNIT- -TERMINATOR-
g
CR LF
Unstable data communication
U S , G S : - +/- k
-HEADER 1- -HEADER 2- - WEIGHT DATA - -WEIGHT UNIT- -TERMINATOR-
g
CR LF
Gross data communication
S T , G S : - +/- k
-HEADER 1- -HEADER 2- - WEIGHT DATA - -WEIGHT UNIT- -TERMINATOR-
g
CR LF
Tare (Net Weight) data communication
S T , N T : - +/- k
-HEADER 1- -HEADER 2- - WEIGHT DATA - -WEIGHT UNIT- -TERMINATOR-
g
CR LF
Unsable Tare (Net Weight) data communication
U S , N T : - +/- k
-HEADER 1- -HEADER 2- - WEIGHT DATA - -WEIGHT UNIT- -TERMINATOR-
g
CR LF
25
4. PLU SEND PROTOCOL
P 0 3 , B I G A P P L E , 1 , 5 . 0 0 , 0 . 3 0 0
0 3
P
,
B I G : A N A N A , 1 , 5 . 0 0 , 0 . 3 0 0 ,
ENUSER MANUAL STI
\n
\
r
PLU NUMBER
PRODUCT NAME UNIT PRICE PRE - TARE TERMINATOR
Weighing mode
1: Weighing mode 0: Counting mode
5. REPORT SEND MODE
1) Daily\r\n: export daily report
d a i 1 y \r \n
DAILY TERMINTOR
(2) start170718\r\n
end170718\r\n
export custom
report
s t a r t 1 7 0 7 1 8 \r \n
Start Start date TERMINATOR
e n d 1 7 0 7 1 8 \r \n
End End date TERMINATOR
(3) product -- (1-12 direct PLU)\r\
p r o d u c t 0 1 \r \n
product PLU number TERMINATOR
00<N<13
(4) list\r\n Export product information
p r o d u c t 0 1 \r \n
product PLU number TERMINATOR
N<99
(5) list\r\n Export product information
l i s t \r \n
List
(6) recordall\r\n remove all record
TERMINATOR
r e c o r d a 1 1 \r \n
Record all TERMINATOR
26
10. PRINT FORMAT
ENUSER MANUAL STI
27
11. ERROR CODES
Error Message Description Solution
---- Maximum load exceeded Unload or reduce weight
Err 1 Incorrect date Enter the date by using format “yy: mm: dd”
Err 2 Incorrect time Enter the time by using format “hh: mm: ss”
Err 4 Zero setting error
Err 5 Key board error Check the keys and connecter
ENUSER MANUAL STI
Zero setting range exceeded due to switching on. (4%max) Make sure platform empty(4%max) Make sure platform empty.
Err 6 A/D value out of range
Err 7 Percentage Error Please check input data, must be > 0.5d
Err 8 Calibration weight error
Err 9 Unstable Reading
Err 10 Wireless communication failure
Err 11 Communication protocol error Check communication settings
Err 12 Accumulation error Max accumulation times 99 / 999 / weight 999999
Err 13 Lack of unit weight Check unit weight entry data, must be >0.5d
Err 14 Lack of sample Check counting samples entry, must be >20d
Err 15 Gravity error Check the gravity settings. Gravity range must be 0.9xx ~
Err 16 Paper error Check the printer paper
Err 17 Tare out of range Minus weight or overload. Remove the load and restart
Err 18 Pre-tare error Check the pre-tare value
Err 19 Initialize zero error Calibration the scale.
Make sure platform empty and check the pan is installed proper. Check the load cell connectors.
Check the test weights for calibration or linear calibration
Check any air variation, vibration, RF noise and touching some where. Check the load cell and connecters
Check wireless settings or change Com settings from the wireless settings from the wireless
28
Err P Printer error Check the printer settings or connections
Err l Approval setting error
-- ol --- Over range Remove the load. Re calibrate
-- lo --- Underload Minus weight, check the platform and restart or calibrate.
fAil H/
fAil l/
fAil
bA lo /
lo bA
Calibration Error Check the test weights & Re calibrate
Battery low Re charge battery, check the voltages.
Check the PCB jumper settings. Must be connect
jumper pin to K1 (BW series)
12. DRAWING
ENUSER MANUAL STI
29
Error Message Description QTY Spec
1 Pan 1
2 Top cover 1
3 “+”screw 5 M4x8
4 Battery cover 1
5 Level bubble 14.7 1
6 Acrylic board 1
7 Overlay 1
8 Front display board 1
9 Printer fixed bracket 1
10 Printer paper cutter 1
11 TP230 printer module 1
12 Printer cover 1
13 Printer cover 1
14 TP230 printer axis 1
15 “+” round self thread screw 9 ST4x12
ENUSER MANUAL STI
16 Printer button 1
17 Spring 2
18 Paper baffel 1
19 TP230 printer control board 1
20 Paper axis 1
21 Roll paper 1
22 Load cell bracket rubber 4
23 Internal hexagon screw 4 M6x20
24 Spring washer 4 M6
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
Washer 4 M6
Load cell bracket 1
Load cell 1
Hexagon screw 4 M4x16
Hexagon nut 4 M4
“+” round self thread screw 4 ST4x20
Load cell bracket 1
6V10Ah lead acid battery 1
“+” round self thread screw 4 ST4x8
Cable gland 4
Calibration switch board 1
Interface board 1
“+” round self thread screw 9 ST3x8
Round adaptor jack 1
Bottom cover 1
Fixed foot 4
Foot 4
Seal plastic 2
Fragile paper 2
30
ENUSER MANUAL STI
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
USB paster 1
“+” round machine screw 4 M4x35
Tube socket cover 1
“+” round machine screw 4 M4x12
Tube socket 1
Pole 2
Pole rotary joint 1
Screw 1
Rear display fixing bolt 1
Pole display rear cover 1
Main board 1
Foam 1
Pole display overlay 1
Pole display front cover 1
+” round self thread screw 2 ST4x10
+” round self thread screw 1 ST3x16
+” round self thread screw 16 ST3x8
13. DOWNLOAD SOFTWARE
1) TTC software for PC for the management of the PLU’s and to generate reports. Free download through the website.
https://www.baxtran.com/fr/commerciales/sti.html
2) Fill in the fields and press the button
31
ENUSER MANUAL STI
| marca propiedad de | est une marque de | trade mark propiety of | marchio proprietà di:
Pol. Empordà Internacional Calle F. Parcela 15-16
17469 VILAMALLA - (Girona) SPAGNA
T. (34) 972 527 212 - F. (34) 972 527 211
32
Loading...