Baxi Potterton 24 Eco HE User Manual

Performa
24 Eco HE
Condensing
Combination Boiler
You can rely on
User Guide and Important Warranty Information
Please keep these instructions in a safe place.
If you move house, please hand them over to
the next occupier.
Reset
Burner On
Flame Failure
Power On
2
1
3
4
0
bar
2
Natural Gas
Potterton Performa 24 Eco HE
G.C.No47 393 11
1.0 Quick Reference Guide 3
2.0 Troubleshooting 4
3.0 Repressurising the System 6
4.0 Fault Indication 7
5.0 Clearances & Cleaning 8
6.0 Legislation 9
7.0 Notes 10
8.0 Emergency 11
9.0 Warranty & Service 12
Section Page
Contents
Boiler Controls - see opposite page
for Operating Quick Reference Guide
Where fitted, user label for optional
timer to be applied here.
© Baxi Heating UK Ltd 2011 All rights reserved. No part of this publication may
be reproduced or transmitted in any form or by any means, or stored in any retrieval system of any nature (including in any database), in each case whether electronic, mechanical, recording or otherwise, without the prior written permission of the copyright owner, except for permitted fair dealing under Copyrights, Designs and Patents Act 1988.
Applications for the copyright owner’s permission to reproduce or make other use of any part of this publication should be made, giving details of the proposed use, to the following address:
The Company Secretary, Baxi Heating UK Ltd, Brooks House, Coventry Road, Warwick. CV34 4 LL
Full acknowledgement of author and source must be given.
WARNING: Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages.
0086
ISO 9001
FM 00866
The Benchmark Scheme
Baxi Heating UK Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance.
Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk
1.0 Quick Reference Guide
3
Reset
Burner On
Flame Failure
Power On
bar
0
1
2
3
4
ON/OFF/Reset Selector Switch
Indicator Neons Central Heating
Temperature Control
Domestic Hot Water Temperature Control
System Pressure Gauge
OFF Position
The boiler will not operate.
Central Heating Temperature Control
Turn the knob clockwise to increase or anticlockwise to decrease the temperature. Range 35 - 85° C.
Domestic Hot Water Temperature Control
Turn the knob clockwise to increase or anticlockwise to decrease the temperature. Range 35 - 65° C.
Power On Indicator - The indicator will illuminate when there is power to the boiler.
Flame Failure Indicator - The indicator will illuminate when the burner has not fired.
Burner On Indicator - The indicator will illuminate when the burner has fired and is heating
your central heating or domestic hot water.
Central Heating System Pressure - The normal operating water pressure is shown when the needle is between 1 and 2.5 bar. If the pressure exceeds 3 bar the safety pressure valve will operate and a fault is indicated. Contact your Installer.
Reset
Central Heating & Hot Water
Both Heating & Hot Water will operate.
Reset
Hold for approx 5 seconds and release.
Indicator Neons
Position of
Optional Timer
Reset
Domestic Hot Water
Hot Water will operate.
Reset
Burner On
Flame Failure
Power On
2
1
3
4
0
bar
2.0 Troubleshooting
4
START
Make sure the gas supply is turned ON and check if other gas appliances are operating (e.g. fire, cooker).
If no gas, consult your supplier.
Is the ON/OFF/Reset Select Switch in the ( ) position and the Power ON Indicator lit ?
Is the ( ) and the ( ) indicator neon on ?
Burner On
Flame Failure
Power On
Check electricity to the boiler is switched on.
Reset
Power On Indicator
Burner On
Flame Failure
Power On
Burner On Indicator
Boiler operating satisfactorily.
bar
0
1
2
3
4
Is the Central Heating System Pressure needle in the GREEN section, between 1 and 2.5 bar ?
If the reading falls below 1 bar repressurise the system as described in section 3.1.
Is the ( ) indicator neon on?
Boiler not working
NO
NO
YES
YES
YES
NO
Turn the ON/OFF/Reset Selector Switch to Reset.
NO
YES
YES
NO
If boiler does not Reset
Power On Indicator
Burner On
Flame Failure
Power On
Flame Failure Indicator