Baxi Potterton 18 HE A-24 HEA A-28HE A User Manual

© Baxi Heating UK Ltd 2010
User Guide and Important Warranty Information
Please keep these instructions in a safe place.
If you move house, please hand them over to
the next occupier.
Gold System
A
Range
Condensing
System Boiler
You can rely on
2
© Baxi Heating UK Ltd 2010
© Baxi Heating UK Ltd 2010 All rights reserved. No part of this publication may
be reproduced or transmitted in any form or by any means, or stored in any retrieval system of any nature (including in any database), in each case whether electronic, mechanical, recording or otherwise, without the prior written permission of the copyright owner, except for permitted fair dealing under Copyrights, Designs and Patents Act 1988.
Applications for the copyright owner’s permission to reproduce or make other use of any part of this publication should be made, giving details of the proposed use, to the following address:
The Company Secretary, Baxi Heating UK Ltd, Brooks House, Coventry Road, Warwick. CV34 4LL
Full acknowledgement of author and source must be given.
WARNING: Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages.
1.0 Quick Reference Guide 3
2.0 Troubleshooting 4
3.0 Repressurising System 6
4.0 Clearances 7
5.0 Care of the Boiler 8
6.0 Legislation 9
7.0 Notes 10
8.0 Emergency 11
9.0 Warranty & Service 12
Section Page
Contents
Boiler Controls - see opposite page
for Operating Quick Reference Guide
0086
ISO 9001
FM 00866
The Benchmark Scheme
Baxi Heating UK Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance.
Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk
Natural Gas
Potterton Gold System 18 HE A
G.C.No41 592 15
Potterton Gold System 24 HE A
G.C.No41 592 16
Potterton Gold System 28 HE A
G.C.No41 592 17
1.0 Quick Reference Guide
3
© Baxi Heating UK Ltd 2010
Reset
bar
0
1
2
3
4
ON/OFF/Reset Selector Switch
Display Central Heating
Temperature Control
Calibration Control System Pressure Gauge
OFF Position
The boiler will not operate.
Central Heating Temperature Control
Turn the knob clockwise to increase or anticlockwise to decrease the temperature. Range 25 - 80° C.
Calibration Control
This control is for use only by the installer or service engineer.
Central Heating Indicator - The indicator will illuminate when the boiler is in the central heating mode.
Burner On Indicator - The indicator will illuminate when the burner has fired and is heating your central heating or domestic hot water.
Boiler Output Temperature - In either the central heating or domestic hot water position the display will illuminate showing the current boiler temperature in degrees centigrade.
Central Heating System Pressure - The normal operating water pressure is between 1 and
2.0 bar. If the pressure exceeds 3 bar the safety pressure valve will operate and a fault is indicated. Contact your Installer.
Reset
Reset
Central Heating & Hot Water
Both Heating & Hot Water will operate.
Reset
Hold for approx 5 seconds and release.
Display
Reset
2
1
3
4
0
bar
2.0 Troubleshooting
4
© Baxi Heating UK Ltd 2010
START
Make sure the gas supply is turned ON and check if other gas appliances are operating (e.g. fire, cooker).
If no gas, consult your supplier.
Is the ON/OFF/Reset Select Switch in the ( ) position and the display lit ?
Is the ( ) light on and the ( ) on ?
Check electricity to the boiler is switched on.
Reset
Display
Central Heating Indicator
Burner On Indicator
Boiler operating satisfactorily.
bar
0
1
2
3
4
Is the Central Heating System Pressure needle in the GREEN section, between 1 and 2.5 bar ?
If the reading falls below 1 bar repressurise the system as described in section 3.1.
Does the display show an error code e.g. E133, E110 ?
Boiler not working
NO
NO
YES
YES
YES
NO
Turn the ON/OFF/Reset Selector Switch to Reset.
Reset
Error Code E119 showing low pressure.
NO
YES
YES
NO
If boiler does not Reset