Baxi Solarflo In-Roof tile Quick Start Manual

© Baxi Heating UK Ltd 2011
GUIDANCE NOTES
Solar Collectors
In-Roof Tile Installation (First Fix)
Please leave these instructions
with the User
2
© Baxi Heating UK Ltd 2011
3
4
5
6
8
11
12
13
16
20
24
1.0 Legislation
2.0 General Layout
3.0 Icon Quick Reference Guide
4.0 Dimensions
5.0 Health & Safety
6.0 Snow & Wind Load
7.0 Optimum Pipework Assembly
8.0 Kit Contents and Components
9.0 Installation of the Collector
10.0 Fixing the Flashing
11.0 Maintenance
3
1.0 Legislation
© Baxi Heating UK Ltd 2011
Please note the following instructions regarding laws, regulations and technical rules.
When setting up solar energy installations, the laws and regulations at local, state, European and international level that apply to the country in question must be observed. Generally acknowledged technical regulations apply; these are usually formulated in the form of standards, guidelines, provisions, regulations and technical rules laid down by local and national bodies, energy supply companies, trade organisations and technical committees in the relevant fields. The installation of solar units may require improved rain resistance with regard to roof, wall and sealing technology and this must be taken into account accordingly. To meet regulations for the prevention of accidents, it may be necessary to use safety equipment (straps, scaffolding, supports, etc.). Such safety equipment is not supplied and must be ordered separately. Installation must only be carried out by technically qualified and authorised personnel with a recognised qualification (verified by a state or national body) in the relevant technical area.
Use a safety harness when working at height. The structure of the roof must be assessed for its suitability prior to commencing work.
This product is unclassified against BS 476-3.
Consult a Structural Engineer if you are unsure of the collector’s siting. Loading due to snow may exceed the capability of the property’s structure. Wind loads may cause excess forces on the structure and cause damage. The Installer is responsible for the suitability of the site and its sub-structure. The collector should be sited to avoid damage from falling debris and vandalism. All pipe work within this installation must be Earth bonded. In exposed areas, the collector must be protected against the risk of lightning. It is recommended that a minimum of 2 people are used to lift this product. The collector must not be lifted by its pipe connections. Ensure all hydraulic connections are securely fixed and are free of leaks. The system must be inspected on completion of the work. A further inspection is recommended annually. Avoid installing the collector in shaded areas. The general recommended torque setting for nuts and bolts is 10Nm. A separate second array can be installed behind the first if necessary. Large arrays will require specialist piping, pump groups and design. The collector must not be installed on an uneven roof surface. Do not apply excessive force when installing the collector. Hot, exposed surfaces that can be touched must be insulated to protect against injury. Lubrication is not required for the ‘O’ ring connections.
4
2.0 General Layout
© Baxi Heating UK Ltd 2011
Wes t
> 350mm
> 500mm
100mm
> 500mm
North
90°
50°50°
40°40°
30°30°
20°20°
10°10°
South
Angle of tilt
70°70°
60°60°
90°
80°80°
East
S.E.S.W.
20° to 55°
less than optimum by 0-5% 5-10% 10-20%
5
3.0 Icon Quick Reference Guide
© Baxi Heating UK Ltd 2011
3A 3B 3C
3D 3E 3F
3G 3H 3J
3K 3L 3M
3N 3P
3Q
R/H
L/H
13mm
!
3A - Contents
3B - Page Reference Number
3C - Measure
3D - Specialist Advice Required
3E - Materials to be Provided by Installer
3F - Spanner Tight
3G - Information or Advice
3H - Screwdriver
3J - Hammer
3K - 1 Collector
3L - 2 Collectors
3M - Right Hand Side
3N - Left Hand Side
3P - Caution
3Q - Drill / Driver
3R - Tile Cutter
3R
6
4.0 Dimensions
© Baxi Heating UK Ltd 2011
150 / 300mm
a
c
d
b
e
f
a
b
c
d
e
f
a
b c
d
e
f
130
390
174.5 40 40
174.5
130
390
174.5
40
174.5
174.5
174.5
130
390
f
kg
10
0
bar
!
SOL 200
35kg
10bar
SOL 200H SOL 250 SOL 250H
36kg
10bar
48kg
10bar
49kg
10bar
7
4.0 Dimensions
© Baxi Heating UK Ltd 2011
a
b
c
d
e
f
a
b
c
d
e
f
a
b
c
d
e
f
a
b
c
d
e
f
a
b
c
d
e
f
1496
1753
1610
2272
1147
1289
2683
1753
1610
2272
2334
2476
3870
1753
1610
2272
3521
3663
5057
1753
1610
2272
4708
4850
6244
1753
1610
2272
5895
6037
Sol 200 Sol 200H Sol 250 Sol 250H
2101
1147
1004
1666
1753
1895
3895
1147
1004
1666
3546
3688
5688
1147
1004
1666
5339
5481
7481
1147
1004
1666
7132
7274
9274
1147
1004
1666
8925
9067
1496
2187
2044
2706
1147
1289
2683
2187
2044
2706
2334
2476
3870
2187
2044
2706
3521
3663
5057
2187
2044
2706
4708
4850
6244
2187
2044
2706
5895
6037
2536
1147
1004
1666
2187
2329
4763
1147
1004
1666
4414
4556
6990
1147
1004
1666
6641
6783
9217
1147
1004
1666
8868
9010
11444
1147
1004
1666
11095
11237
1
2
3
4
5
a
b
c
d
e
f
a
b
c
d
e
f
a
b
c
d
e
f
a
b
c
d
e
f
a
b
c
d
e
f
7431
1753
1610
2272
7082
7224
8618
1753
1610
2272
8269
8411
9805
1753
1610
2272
9456
9598
10992
1753
1610
2272
10643
10785
12179
1753
1610
2272
11830
11972
Sol 200 Sol 200H Sol 250 Sol 250H
11067
1147
1004
1666
10718
10860
12860
1147
1004
1666
12511
12653
14653
1147
1004
1666
14304
14446
16446
1147
1004
1666
16097
16239
18239
1147
1004
1666
17890
18032
7431
2187
2044
2706
7082
7224
8618
2187
2044
2706
8269
8411
9805
2187
2044
2706
9456
9598
10992
2187
2044
2706
10643
10785
12179
2187
2044
2706
11830
11972
13671
1147
1004
1666
13322
13464
15898
1147
1004
1666
15549
15691
18125
1147
1004
1666
17776
17918
20352
1147
1004
1666
20003
20145
22579
1147
1004
1666
22230
22372
6
7
8
9
10
mm mm
8
5.0 Health and Safety
© Baxi Heating UK Ltd 2011
!