Baxi Solarflo In-Roof slate Quick Start Manual

© Baxi Heating UK Ltd 2011
GUIDANCE NOTES
Solar Collectors
In-Roof Slate Installation (First Fix)
Please leave these instructions
with the User
2
© Baxi Heating UK Ltd 2011
3
4
5
6
8
11
12
13
16
20
24
1.0 Legislation
2.0 General Layout
3.0 Icon Quick Reference Guide
4.0 Dimensions
5.0 Health & Safety
6.0 Snow & Wind Load
7.0 Optimum Pipework Assembly
8.0 Kit Contents and Components
9.0 Installation of the Collector
10.0 Fixing the Flashing
11.0 Maintenance
3
1.0 Legislation
© Baxi Heating UK Ltd 2011
Please note the following instructions regarding laws, regulations and technical rules.
When setting up solar energy installations, the laws and regulations at local, state, European and international level that apply to the country in question must be observed. Generally acknowledged technical regulations apply; these are usually formulated in the form of standards, guidelines, provisions, regulations and technical rules laid down by local and national bodies, energy supply companies, trade organisations and technical committees in the relevant fields. The installation of solar units may require improved rain resistance with regard to roof, wall and sealing technology and this must be taken into account accordingly. To meet regulations for the prevention of accidents, it may be necessary to use safety equipment (straps, scaffolding, supports, etc.). Such safety equipment is not supplied and must be ordered separately. Installation must only be carried out by technically qualified and authorised personnel with a recognised qualification (verified by a state or national body) in the relevant technical area.
Use a safety harness when working at height. The structure of the roof must be assessed for its suitability prior to commencing work. Consult a Structural Engineer if you are unsure of the collector’s siting. Loading due to snow may exceed the capability of the property’s structure. Wind loads may cause excess forces on the structure and cause damage. The Installer is responsible for the suitability of the site and its sub-structure. The collector should be sited to avoid damage from falling debris and vandalism. All pipe work within this installation must be Earth bonded. In exposed areas, the collector must be protected against the risk of lightning. It is recommended that a minimum of 2 people are used to lift this product. The collector must not be lifted by its pipe connections. Ensure all hydraulic connections are securely fixed and are free of leaks. The system must be inspected on completion of the work. A further inspection is recommended annually. Avoid installing the collector in shaded areas. The general recommended torque setting for nuts and bolts is 10Nm. A separate second array can be installed behind the first if necessary. Large arrays will require specialist piping, pump groups and design. The collector must not be installed on an uneven roof surface. Do not apply excessive force when installing the collector. Hot, exposed surfaces that can be touched must be insulated to protect against injury. Lubrication is not required for the ‘O’ ring connections.
4
2.0 General Layout
© Baxi Heating UK Ltd 2011
Wes t
> 350mm
> 500mm
100mm
> 500mm
North
90°
50°50°
40°40°
30°30°
20°20°
10°10°
South
Angle of tilt
70°70°
60°60°
90°
80°80°
East
S.E.S.W.
20° to 55°
less than optimum by 0-5% 5-10% 10-20%
5
3.0 Icon Quick Reference Guide
© Baxi Heating UK Ltd 2011
3A 3B 3C
3D 3E 3F
3G 3H 3J
3K 3L 3M
3N 3P
3Q
R/H
L/H
13mm
!
3A - Contents
3B - Page Reference Number
3C - Measure
3D - Specialist Advice Required
3E - Materials to be Provided by Installer
3F - Spanner Tight
3G - Information or Advice
3H - Screwdriver
3J - Hammer
3K - 1 Collector
3L - 2 Collectors
3M - Right Hand Side
3N - Left Hand Side
3P - Caution
3Q - Drill / Driver
3R - Tile Cutter
3R
6
4.0 Dimensions
© Baxi Heating UK Ltd 2011
a
c
d
b
e
f
a
b
c
d
e
f
a
b c
d
e
f
247
390
174.5 40 40
174.5
247
390
174.5
40
174.5
174.5
174.5
247
390
f
kg
10
0
bar
!
SOL 200
35kg
10bar
SOL 200H SOL 250 SOL 250H
36kg
10bar
48kg
10bar
49kg
10bar
7
4.0 Dimensions
© Baxi Heating UK Ltd 2011
a
b
c
d
e
f
a
b
c
d
e
f
a
b
c
d
e
f
a
b
c
d
e
f
a
b
c
d
e
f
1627
1753
1610
2388
1147
1289
2814
1753
1610
2388
2334
2476
4001
1753
1610
2388
3521
3663
5188
1753
1610
2388
4708
4850
6375
1753
1610
2388
5895
6037
Sol 200 Sol 200H Sol 250 Sol 250H
2232
1147
1004
1782
1753
1895
4026
1147
1004
1782
3546
3688
5819
1147
1004
1782
5339
5481
7612
1147
1004
1782
7132
7274
9405
1147
1004
1872
8925
9067
1627
2187
2044
2822
1147
1289
2814
2187
2044
2822
2334
2476
4001
2187
2044
2822
3521
3663
5188
2187
2044
2822
4708
4850
6375
2187
2044
2822
5895
6037
2667
1147
1004
1782
2187
2329
4895
1147
1004
1782
4414
4556
7122
1147
1004
1782
6641
6783
9349
1147
1004
1782
8868
9010
11576
1147
1004
1782
11095
11237
1
2
3
4
5
a
b
c
d
e
f
a
b
c
d
e
f
a
b
c
d
e
f
a
b
c
d
e
f
a
b
c
d
e
f
7562
1753
1610
2388
7082
7224
8618
1753
1610
2388
8269
8411
9805
1753
1610
2388
9456
9598
11123
1753
1610
2388
10643
10785
12310
1753
1610
2388
11830
11972
Sol 200 Sol 200H Sol 250 Sol 250H
11198
1147
1004
1782
10718
10860
12991
1147
1004
1782
12511
12653
14784
1147
1004
1782
14304
14446
16577
1147
1004
1782
16097
16239
19370
1147
1004
1782
17890
18032
7562
2187
2044
2822
7082
7224
8618
2187
2044
2822
8269
8411
9805
2187
2044
2822
9456
9598
11123
2187
2044
2822
10643
10785
12310
2187
2044
2822
11830
11972
13803
1147
1004
1782
13322
13464
16030
1147
1004
1782
15549
15691
18257
1147
1004
1782
17776
17918
20484
1147
1004
1782
20003
20145
22711
1147
1004
1782
22230
22372
6
7
8
9
10
mm mm
8
5.0 Health and Safety
© Baxi Heating UK Ltd 2011
!
Loading...
+ 16 hidden pages