Baxi Main 12 HE A, Main 18 HE A, Main 15 HE A, Main 24 HE A, Main 30 HE A User Manual

© Baxi Heating UK Ltd 2014
Users Guide and Important Warranty Information
HE
A Range
Please keep these instructions in a safe place.
If you move house, please hand them over to the next occupier.
2
© Baxi Heating UK Ltd 2014
Natural Gas
Main 12 HE A
G.C.No41-467-16
Main 15 HE A
G.C.No41-467-17
Main 18 HE A
G.C.No41-467-18
Main 24 HE A
G.C.No41-467-19
Main 30 HE A
G.C.No41-467-20
© Baxi Heating UK Ltd 2014 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any retrieval system of any nature (including in any database), in each case whether electronic, mechanical, recording or otherwise, without the prior written permission of the copyright owner, except for permitted fair dealing under Copyrights, Designs and Patents Act 1988.
Applications for the copyright owner’s permission to reproduce or make other use of any part of this publication should be made, giving details of the proposed use, to the following address:
The Company Secretary, Baxi Heating UK Ltd, Brooks House, Coventry Road, Warwick. CV34 4LL
Full acknowledgement of author and source must be given.
WARNING: Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages.
1.0 Operating the Boiler 3
2.0 Troubleshooting 4
3.0 Clearances 6
4.0 Care of the Boiler 7
5.0 Legislation 8
6.0 Notes 9
7.0 Emergency 11
8.0 Warranty & Service 12
Section Page
Contents
0086
ISO 9001
FM 00866
The Benchmark Scheme
Baxi Heating UK Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance.
Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk
1.0 Operating the Boiler
3
© Baxi Heating UK Ltd 2014
1.1 In Operation
1. The Main HE A is a range of high efficiency condensing boilers.
2. In common with other condensing boilers its exceptional efficiency means the flue gases are cooled to such an extent that steam is often visible at the outside flue terminal.
3. The amount produced depends on system design, product use and outside air temperature but it is not harmful to the individual or the working of the boiler in any way.
4. Other Controls A programmer or other type of clock should have been fitted in your system, together with heating and hot water controls. Full instructions on the use of these controls will have been supplied with them.
1.2 To Light
1. Ensure that the main gas and electricity supplies to the boiler are ON.
2. The fan will start to run and after a short period the ignition spark will commence. Sparking will continue until the flame is established then stop automatically. Check that a flame is visible through the sight glass.
Sight Glass
2.0 Troubleshooting
4
© Baxi Heating UK Ltd 2014
Boiler not working
START
Make sure the gas supply is turned ON and check if other gas appliances are operating (e.g. fire, cooker).
NO
If no gas, consult your supplier.
Is there electricity to the boiler ?
Check electrical supply to
boiler is switched on.
NO
YES
Ignition Spark will commence
Boiler operating
satisfactorily.
NO
YES
YES
YES
Boiler fails to light ?
YES
Press the Reset Button
If boiler will not light.
CONTACT YOUR
INSTALLER OR
SERVICE
ENGINEER.
Boiler flame established (Check that a flame is visible through the sight glass)