57132
..........................................
;.
.
Kingston Deluxe
Belgravia Deluxe
Thermostatic Control of High Rate
The HIGH rate setting is thermostatically
controlled. The temperature at which the
thermostat operates can be altered by means
of the control knob situated behind the
controls access door. This is variable between
WARM and HOT. If the control knob is set on
HOT the fire will run on HIGH rate almost
continually. With the control knob on WARM
the HIGH rate will operate intermitently, the
fire dropping to MEDIUM rate when the
thermostat is satisfied. The control knob can
be set anywhere between these positions,
depending on size of room, other heating
sources, personal preferences etc.
2.0 Introduction
EIII Introduction
1. Your Baxi Cavendish Deluxe, Kingston Deluxe
or Belgravia Deluxe are live fuel effect inset gas
fires. The realistic coal effect is achieved by the
use of a multi-piece fuel bed and specially
designed gas burner rail.
~ Operating the Unit (Fig. 1)
1. The fire is controlled by a lever which is
positioned at the top right of the trim. The lever
has five positions:
Position
e
Position
* ;
IGNITION/PILOT
The High setting is thermostatically controlled.
2. To light the fire from the OFF position
(e)
push
the control lever down as far as possible to the
IGNITION/PILOT position
(*)
and the pilot should
light. If not, repeat the operation.
3. Once the pilot is alight continue to hold the
control lever down for twenty seconds.
4. Release the control lever. It will go to the
LOW/SUMMER rate position. To obtain MEDIUM
and HIGH gas rates, move the control lever
upwards to the appropriate position. Moving the
control lever to the uppermost position will
extinguish the fire.
5. The light effect is controlled by a master switch
behind the controls access door. With the master
switch in the ON position the light effect will
operate in the LOW/SUMMER position and
IGNITION/PILOT position.
6. To illuminat the light effect without the fire in
operation move the control lever from OFF to the
LOW/SUMMER position, with the master switch
ON.
NOTE: If the fire goes out at any time wait 2
minutes and repeat the ignition procedure.
7. To turn the fire off: Pull the control lever up as
far as possible to the OFF position
(e).
NOTE: When your Cavendish, Kingston or
Belgravia is first used it is possible some smells
may be emitted. These smells will quickly clear
with use.
EIII Cleaning the Fire
1. The fire may be cleaned with a damp cloth and
wiped with a soft duster. Do not use metal polish
on any parts of the appliance. It is not advisable to
use a vacuum cleaner attatchment to clean the top
of the coal bed as the material is fragile and easily
damaged.
e.
Shelf
1. A shelf may be fitted above the fire providing it
is minimum height from the hearth of 830mm
(3221/32in)and does not project more than 150mm
(529/32in).When the shelf depth is increased in
increments of 13mm ('/2in) over the 150mm
(529/32in)the height should be increased by 25mm
(1in) for every 13mm ('/2in).