Baxi Barselona User Manual

Page 1
Baxi Barcelona
Wall Mounted Powered Flue Condensing Boiler
Gas Fired Central Heating Unit
User’s Operating Instructions
Please keep these instructions safe.
Should you move house, please hand
Page 2
2
Baxi UK Limited is one of the leading manufacturers
of domestic heating products in the UK.
Our first priority is to give a high quality service to our
customers. Quality is designed into every Baxi product
- products which fulfil the demands and needs of
customers, offering choice, efficiency and reliability.
To keep ahead of changing trends, we have made a
commitment to develop new ideas using the
latest technology - with the aim of continuing to
make the products that customers want to buy.
Baxi is also the largest manufacturing partnership in
the country. Everyone who works at the company has
a commitment to quality because, as shareholders, we
know that satisfied customers mean continued
success.
We hope you get a satisfactory service from Baxi. If
not, please let us know.
Natural Gas
Baxi Barcelona
G.C.No41 075 02
Baxi is a BS-EN ISO 9001 Accredited Company
The boiler meets the requirements of Statutory Instrument “ The Boiler (Efficiency) Regulations 1993 N
o
3083” and is deemed to meet the requirements of Directive 92/42/EEC on the energy efficiency requirements for new hot water boilers fired with liquid or gaseous fuels:-
Type test for purpose of Regulation 5 certified by: Notified Body 0086.
Product/Production certified by: Notified Body 0086.
For GB/IE only.
Page 3
1.0 Warnings
3
1.1 Safe Installation
1. The installation must be carried out by a CORGI Registered Installer or other registered competent person and be in accordance with the relevant requirements of the current G
AS SAFETY
(Installation and Use) REGULATIONS, the BUILDING REGULATIONS (Scotland)(Consolidation), the LOCAL BUILDING REGULATIONS, the current I.E.E. WIRING REGULATIONS and the bye laws of the LOCAL WATER UNDERTAKING. Where no specific instruction is
given reference should be made to the relevant BRITISH STANDARD CODES OF PRACTICE. For Ireland install in accordance with IS 813 I
NSTALLATION OF GAS APPLIANCES”. Reference
should also be made to B
RITISH GAS GUIDANCE
NOTES FOR THE INSTALLATION OF DOMESTIC GAS CONDENSING BOILERS.
2. This appliance must be installed in accordance with the manufacturers instructions and the rules in force, and only used in a suitably ventilated location.
3. Read the instructions before installing or using this appliance.
4. Any purpose provided ventilation should be checked periodically to ensure that it is free from obstruction.
IMPORTANT - The addition of anything that may interfere with the normal operation of the appliance without the express written permission of Baxi UK Limited could invalidate the appliance warranty and infringe the G
AS
SAFETY (Installation and Use) REGULATIONS.
1.2 In case of gas leaks
1. If a gas leak is found or suspected, turn off the
gas supply at the meter immediately and at the
isolating valve on the boiler if possible. Contact your
Installer or Transco (under 'Gas' in the phone
directory). Do not operate any electrical equipment
or light switches.
1.3 Servicing your Appliance
1. For reasons of safety and economy your appliance
should be serviced annually. Your Installer or British
Gas Service will be able to advise you.
1.4 Electricity Supply
1. THIS APPLIANCE MUST BE EARTHED.
2. A standard 230V ~ 50Hzsupply is required. The
appliance must be protected by a 3 amp fuse.
Never Hang Flammable Items Over
The Appliance
B.S. Codes of Practice
Standard Scope
BS 6891 Gas Installation. BS 5546 Installation of hot water supplies for
domestic purposes. BS 5449 Part 1 Forced circulation hot water systems. BS 6798 Installation of gas fired hot water boilers. BS 5440 Part 1 Flues. BS 5440 Part 2 Ventilation. BS 7074 Expansion vessels and ancillary
equipment for sealed water systems. BS 7593 Treatment of water in domestic hot water
central heating systems.
Benchmark Installation, Commissioning and Service Record Log Book
Please ensure that your installer has completed the Installation and Commissioning sections of the Log Book and hands the Log Book over. The details of the Log Book will be required in the event of any warranty work. Keep the Log Book in a safe place and ensure that the relevant sections are completed at each subsequent regular service visit.
All CORGI registered installers carry a CORGI identification card and have a registration number. Both should be recorded in your boiler Log Book. You can check your installer is registered by telephoning 01256 372300 or writing to:­1 Elmwood, Chineham Business Park, Crockford Lane, Basingstoke. RG24 8WG.
Page 4
2.0 Operating the Boiler
4
2.1 Operating the Boiler
1. Remove the lower door panel by gripping it’s lower edge and rotating upwards (Fig. 1).
2. Turn on the main gas and electricity supplies to the appliance.
3. Set the boiler thermostat control knob to the required setting (Fig. 3). (The optimum boiler setting depends upon type of system, external controls and your requirements. Your installer will be able to advise you on this matter.)
4. The fan will start to run and after a short period the ignition spark will commence. Sparking will continue until the flame is established then stop automatically. Check that both the mains ON light and boiler ON light are on. Mains ON is indicated by green and boiler ON by yellow (Fig. 2).
5. Flashing mains ON light indicates that there is a mains electrical supply to the boiler, but the control knob is in the OFF position. Turn the control knob on and ignition will start.
2.2 To shut down the Boiler
1. Turn off the electricity supply to the appliance at the mains.
2. Turn the boiler thermostat control knob to OFF (Fig. 4), then turn off the gas supply at either the appliance gas cock or the meter.
2.3 Frost Protection
1. The boiler does not have integral frost protection. It is recommended that the installer fits a suitable protection device to the system controls if required. For frost protection the boiler must be turned on.
2.4 In Operation
1. The Barcelona is a high efficiency condensing boiler. In common with other condensing boilers its exceptional efficiency means the flue gases are cooled to such an extent that steam is often visible at the outside flue terminal. The amount produced depends on system design, product use and outside air temperature but it is not harmful to the individual or the working of the appliance in any way.
H I G
H
L O
W
Lower Door Panel
HIGH
LOW
HIGH
LOW
Fig. 1
Fig. 3
Fig. 4
HIGH
LOW
Boiler Thermostat Control Knob
Mains ON
(Green)
Boiler ON
(Yellow)
Overheat or Lockout
(Red)
Fig. 2
HIGH Position
OFF Position
Page 5
3.0 Safety Devices
5
3.1 Operation of Safety Devices
1. Your Baxi Barcelona is fitted with safety devices which shut down the appliance if:
a) the system overheats. b) the condensate drain is blocked. c) there is no gas to the boiler.
2. The lockout indicator light will be either flashing or permanently illuminated and the boiler will need resetting (Fig. 6).
NOTE: In the case of persistent operation of the devices, turn off the boiler and consult your service engineer as an appliance or system fault is indicated.
3.2 Resetting
1. Allow the boiler to cool if hot.
2. Remove the lower door panel by gripping it’s lower edge and rotating upwards (Fig. 5).
TO RESET THE BOILER if the lockout indicator light is flashing once a second, follow these instructions.
3. Turn the boiler thermostat control knob fully anti-clockwise to the OFF position marked (Fig. 7).
4. Wait 10 seconds.
5. Turn the boiler thermostat control knob clockwise to the required thermostat setting, the overheat light will go out and the boiler will fire up automatically when it has sufficiently cooled.
TO RESET THE BOILER if the lockout indicator light is permanently illuminated, follow these instructions.
6. Check that the gas supply to the appliance has not been inadvertantly turned off.
7. Check the condensate drain outlet has not been blocked.
WARNING: The condensate outlet must not be blocked or modified.
8. Turn the boiler thermostat control knob fully anti-clockwise to the OFF position marked (Fig. 7).
9. Wait 10 seconds.
10. Turn the boiler thermostat control knob clockwise to the required thermostat setting, the overheat or lockout light will go out and the boiler will fire up automatically.
HIGH
LOW
Boiler Thermostat Control Knob
Mains ON
(Green)
Boiler ON
(Yellow)
Overheat or Lockout
(Red)
Fig. 6
HIGH
LOW
Fig. 7
OFF Position
H I G
H
L O
W
Lower Door Panel
Fig. 5
Page 6
4.0 Clearances
6
4.1 Clearances around the Boiler
(Figs. 8 & 9)
1. The minimum clear spaces needed around the boiler are:
Top - 200mm Bottom - 130mm Both sides - 5mm Front - 500mm (For Servicing)
- 5mm (In Operation)
2. The boiler may be installed in a cupboard if these minimum clearances are kept and permanent ventilation to the boiler is provided in the compartment. The sizes of the ventilation opening at high and low levels are as follows:
3. These clearances and vents must not be
obstructed in any way. Blocking these will result in the boiler overheating and possible damage may occur.
4. The compartment should be large enough to house the boiler and ancillary equipment only.
5. IT SHOULD NOT BE USED AS A STORAGE
CUPBOARD.
6. The gas burning compartment of your boiler is completely sealed from the room in which it is fitted. Products from the combustion of gas are vented to the outside through the flue terminal which must be kept free from obstruction as this would interfere with the correct operation of the boiler.
7. The condensate drain must not be blocked or modified.
130mm
600mm
390mm
200mm
5mm Min
5mm Min
5mm
500mm
For Servicing
Purposes
Fig. 8
Fig. 9
In Operation
3°
320mm
Position of Air from Air direct Air Vent Room from Outside
High 306cm2(49 in2) 153cm2(24.5in2)
Low 306cm2(49 in2) 153cm2(24.5in2)
Page 7
5.0 Cleaning, Spares & Guarantee
7
5.1 Cleaning the Outercase
The painted panels should be wiped with a damp cloth and then dried completely. DO NOT USE
ABRASIVE CLEANING AGENTS.
5.2 Spare Parts
Repairs should be carried out by a CORGI Registered Installer or other Registered Person
1. Any repairs to the boiler will usually be the responsibility of the Installer during the guarantee period after which spare parts may be obtained through approved Baxi stockists if required.
2. Quote the appliance name, model number (found on the reverse of the lower door panel) and where possible the part number when ordering spares. A short parts list is included in the Installation and Servicing Instructions.
5.3 Guarantee
1. Your Baxi Barcelona is designed and produced to meet all the relevant Standards.
2. Baxi UK Limited provide a 12 month guarantee on the boiler. The guarantee operates from the date installation is completed for the customer who is the original user.
3. To maximise the benefit from our guarantee we urge you to return the reply-paid guarantee registration.
4. This does not in any way prejudice your rights at Common Law. Such rights between the customer and the installer or supplier from whom the unit was purchased remain intact.