Baumer ZADM 034P240.6901 User Manual [en, fr, de]

Canada
Baumer Inc. CA-Burlington, ON L7M 4B9 Phone +1 (1)905 335-8444
Baumer (China) Co., Ltd. CN-201612 Shanghai Phone +86 (0)21 6768 7095
Denmark
Baumer A/S DK-8210 Aarhus V Phone +45 (0)8931 7611
France
Baumer SAS FR-74250 Fillinges Phone +33 (0)450 392 466
Germany
Baumer GmbH DE-61169 Friedberg Phone +49 (0)6031 60 07 0
India
Baumer India Private Limited IN-411038 Pune Phone +91 20 2528 6833/34
Italy
Baumer Italia S.r.l. IT-20090 Assago, MI Phone +39 (0)2 45 70 60 65
Singapore
Baumer (Singapore) Pte. Ltd. SG-339412 Singapore Phone +65 6396 4131
Sweden
Baumer A/S SE-56133 Huskvarna Phone +46 (0)36 13 94 30
Switzerland
Baumer Electric AG CH-8501 Frauenfeld Phone +41 (0)52 728 1313
United Kingdom
Baumer Ltd.
GB-Watchfield, Swindon, SN6 8TZ
Phone +44 (0)1793 783 839
USA
Baumer Ltd. US-Southington, CT 06489 Phone +1 (1)860 621-2121
www.baumer.com/worldwide
Baumer Electric AG · CH-8501 Frauenfeld Phone +41 (0)52 728 1122 · Fax +41 (0)52 728 1144
Line sensor, digital
M 8 x 1
7,7
4,5
8,2 ø
4,3ø
8
2 40max. 16,5
34 3,7
36
25
67 7
5,3
4,5
Plus petit objet détectable
Í?*/{-ÂÂ*Â|Î
10159113
IND. CONT. EQ.
1DD2
1/2
Programmierung
LED grün: Power on, Rückmeldung bei Teach-in LED gelb: Ausgangsanzeige Taste: Teach-in
Statischer Teach-in Ablauf, für ruhende Objekte
1. Den Sensor in den statischen Teach-in-Modus bringen: Taste ca. 2 Sek. drücken bis die LED (grün) blinkt
2. Objekt 1 in den Messbereich halten und Taste kurz drücken (ON­Position)
3. Objekt 2 in den Messbereich halten und Taste kurz drücken (OFF­Position)
--> Der Schaltpunkt wird ca. in die Mitte zwischen Objektgrösse 1 und 2 eingestellt.
ON-Pos > OFF-Pos --> Dunkelschaltung ON-Pos < OFF-Pos --> Hellschaltung
Achtung
mit Objekt: ON-Pos = OFF-Pos --> Dunkelschaltung, nur grössere
ohne Objekt: ON-Pos = OFF-Pos --> Dunkelschaltung, kleinstes
Dynamischer Teach-in Ablauf, für bewegte Objekte
1. Den Sensor in den dynamischen Teach-in-Modus bringen: Taste ca. 5 Sek. drücken bis das Blinken der LED (grün) von langsam zu schnell wechselt. Nach Loslassen der Taste beginnt der Sensor sofort mit dem einlernen der Minimal- und Maximalwerte.
2. Teach-in beenden: Taste kurz drücken
3. Ausgangsfunktion von Dunkelschaltung (Standard) auf Hellschaltung wechseln: Taste innerhalb 5 Sek. nach „Teach-in beenden“ kurz drücken.
-->Der Schaltpunkt wird ca. auf die Mitte der Objektgrössen zwischen Min und Max eingestellt.
Feedback nach dem Teach-in Ablauf
Teach-in OK: LED (grün) leuchtet 2 Sek Teach-in Warnung: LED (grün) blinkt für 2 Sek
Externe Teach-in-Vorgang
Er ist identisch zur Taste, indem man den Teacheingang auf +Vs bei PNP, (0V bei NPN) verbindet. Teach Feedback: Ausgang offen = Teach-in OK
Objekte werden erkannt
Objekt wird erkannt
Kein Reflektor vorhanden oder Reflektor ist komplett abgedeckt
Ausgang geschalten = Teach-in Warnung
Montage
Glänzende und spiegelnde Objekte können störend wirken.
Glänzende Flächen sollten >7° zur Sensor-Frontfläche abgewinkelt.
Hinweis zur Elektromagnetischer Verträglichkeit:
Sensor geerdet montieren und geschirmtes Anschlusskabel verwenden.
Programming
Green LED: Power on, Teach-in feedback Yellow LED: Output indicator Button: Teach-in
Static Teach-in procedure
1. Place the sensor in static teach-in mode: press the button approx. 2 sec until the green LED flashes
2. Place first object within the measuring range and press the button briefly (ON-Position)
3. Place second object within the measuring range and press the button briefly (OFF-Position)
--> The switching point will be in the middle of the two object sizes
ON-Pos > OFF-Pos --> dark operate ON-Pos < OFF-Pos --> light operate
Attention
With object ON-Pos = OFF-Pos --> larger objects will be
Without objects ON-Pos = OFF-Pos --> smallest object, dark
Dynamic Teach-in procedure
1. Place the sensor into dynamic Teach-in mode: press the button approx. 5 sec until the green LED flashing changes from slow to fast. After releasing the button, the sensor immediately starts to sense the max. and min. values
2. Stop the Teach-in procedure: press the button briefly
3. To change the output function from dark operate (standard) to light operate: press the button within 5 sec after stopping the Teach-in
--> The switching point will be in the middle of the two object sizes
Teach feedback after Teach-in procedure
Teach-in OK: Green LED is on for 2 sec Teach-in warning: Green LED is flashing for 2 sec
External teach-in
Same teach procedure as the button method. Instead of pressing the button, connect Teach-in input to +Vs (PNP) or 0V (NPN). Teach feedback: Output open = Teach-in OK
procedure
detected, dark operate
operate (factory setup)
No reflector or reflector totally covered
Output closed = Teach-in warning
Mounting
Shiny and reflective objects can interfere with the sensor’s function.
Tilt the sensor >7° to the shiny surface.
Note to electromagnetic compatibility:
Connect the sensor housing to earth potential. Use shielded connecting cables.
Programmation
LED verte: Alimentation on, confirmation du Teach-in LED jaune: témoin de sortie Touche: Teach-in
Teach-in statique , pour objets fixes
1. Appuyez env. 2 sec sur la touche Teach-in jusqu’à ce que la LED (verte) clignote
2. Placer objet 1 dans la plage de mesure et appuyer sur la touche Teach-in (On-position)
3. Placer objet 2 dans la plage de mesure et appuyer sur la touche Teach-in (Off-positon)
--> Le point de détection sera alors ajusté pour une taille d’objet correspondant à la moyenne des objets 1 et 2.
ON-Pos > OFF-Pos --> Commutation sombre ON-Pos < OFF-Pos --> Commutation clair
Attention
avec l’objet: ON-Pos = OFF-Pos --> Commutation sombre,
sans l’objetÊ: ON-Pos = OFF-Pos --> Commutation sombre,
Teach-in dynamique pour les objets en mouvement
1. Appuez env. 5 sec sur la touche Teach-in jusqu’à ce que la LED verte clignote plus rapidement. Dès que vous relâchez la touche Teach-in, le capteur commence à enregistrer les valeurs min. et max. du signal
2. Terminer le cycle Teach-in: appuyez sur la touche Teach-in
3. La fonction standard mémorisée est la commutation sombre. Pour une commutation claire, appuyez une fois sur la touche Teach-in dans les 5 sec suivant la procédure d’apprentissage.
--> Le point de détection sera alors ajusté pour une taille d’objet correspondant à la moyenne entre le min et le max . mesuré.
Teach feedback après le Teach-in
Teach-in OK: LED (verte) s’allume pendant 2 sec Alerte Teach-in: LED (verte) clignote pendant 2 sec
Procédure de Teach-in externe
L’apprentissage au travers d’un fil externe est identique à la celle du bouton poussoir. Le Teach-in sera effectué par des impulsions +Vs(PNP) ou 0V (NPN) Teach feedback: sortie ouverteÊ: Teach-in en ordre
détection d’ objets plus grands
détection d’ objet plus petits.
Pas de réflecteur ou le réflecteur est complètement couvert.
Sortie commutée =Teach-in alarme
Montage
Objets réfléchissants ou brillants peuvent perturber.
Les surfaces brillantes doivent être inclinées de > 7° par rapport à
la face avant du capteur.
Note à la compatibilité électromagnétique: Connecter le boîter du détecteur au potentiel de terre. Utiliser des câbles de raccordement blindés.