Baumer HXC13 User Manual

63
33
8 x 12-M4 depth 6
63
33
8 x 12-M4 depth 6
Quick Start Guide
HXC13 - Digital High Speed Camera
Product Specication
HXC13 – High speed CMOS camera for advanced industrial vision applications
High resolution: 1280x1024 pixel CMOS Sensor up to 1024 gray levels (10bit resolution) up to 500 full frames/sec arbitrary region of interest very high sensitivity 14 µm square pixels electronic “Freeze Frame” shutter low blooming programmable via CameraLink
®
serial interface
asynchronous trigger small, compact housing wide power supply range
Dimensions
● HXC13 (11008792)
Safety
Conformity:
CE, FCC Part 15 Class B, RoHS
FCC – Class B device
No t e : This equipment has been tested and found to
comply with the limits for a Class B digital device, pursu-
ant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interfer­ence in a residential environment. This equipment gener­ates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructios, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occure in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off an on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and the receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician
for help.
Further Information
For further information on our products visit www.baumer.com For technical issues, please contact our technical support:
support@baumeroptronic.com · Phone +49 (0)3528 4386-0 · Fax +49 (0)3528 4386-86 © Baumer Optronic GmbH · Badstrasse 30 · DE-01454 Radeberg, Germany
Technical data has been fully checked, but accuracy of printed matter not guaranteed.
Subject to change without notice. Printed in Germany 04/12. V1.1 11037740
Safety Precautions
Notice
See user´s Guide for the comple­te safety instructions!
Protect the sensor from dirt and moisture. Never open the camera housing. Avoid camera contamination by foreign objects.
Environmental requirements:
Storage temp. -10°C ... +70°C Operating temp. +5°C ... +50°C Housing temp. max. +50°C Humidity 10 % ... 90 %
Non-condensing
Installation
Installation using Camera Link® BASE:
Connect the camera using an appropriate cable to the framegrabber board on your
PC using the lower mdr-26
jack on the camera side
If required, connect a strobe
to the HIROSE connector
Connect the camera to power supply
Installation using Camera Link
®
MEDIUM /
FULL:
Connect the camera using two appropriate cables to the framegrabber board on your PC (this configuration
requires the BASE and the FULL Camera Link
®
line)
If required, connect a strobe
to the HIROSE connector
Connect the camera to power supply
Installation sample
1 - Framegrabber board; 2 - Camera Link® cable; 3 - Cable for strobe; 4 - Power cable
Installation sample
1 - Framegrabber board; 2 - Camera Link® cable; 3 - Cable for strobe; 4 - Power cable
Dimensions
● HXC13-F (11008791)
Ba u me r
Type: HXCXXx (xxxxxxx) S/N: 000XXXXX
R1.0
CL FULL
CL BASE
C
L BASE
C
L FUL
L
LED
40
63
63
40
40
33
8 x 12-M4 depth 6
1
2
3
4
5
6
w
w
w
.
b
a
u
m
e
r
.
c
o
m
General Description
1
2
3
45
Nr. Description Nr. Description
1 (respective) lens mount 4 Camera Link
2 Power supply 5 Signaling-LED
®
3 Camera Link
Full socket
®
Base socket
LED Signaling
Signal Meaning
off Camera is de-energized.
If LED is off, despite the camera is powered, data is stored to the
internal EEPROM.
No (other) activity is possible.
yellow The camera is conguring the internal FPGA.
No other activity is possible.
green The camera is fully operational.
red The camera's microcontroller detected a configuration error.
The camera's FPGA could not be loaded.
The camera is not functional. Try reload conguration data.
red ash The camera's microcontroller or FPGA is loading data.
Camera verifies checksum.
No other activity is possible.
Dimensions
● HXC13 M42-Mount (11053411)
Camera Link® Interfaces
Notice
The camera has two CameraLink sockets. To differentiate bet­ween CameraLink Base and CamerLink Full socket, please look at the label. You can not use the CL Full socket alone!
®
Full CameraLink
Base CameraLink
Pin Signal Pin Signal Pin Signal Pin Signal
1 GND 14 GND 1 GND 14 GND 2 X0- 15 X0+ 2 Y0- 15 Y0+ 3 X1- 16 X1+ 3 Y1- 16 Y1+ 4 X2- 17 X2+ 4 Y2- 17 Y2+ 5 XCLK- 18 XCLK+ 5 YCLK- 18 YCLK+
6 X3- 19 X3+ 6 Y3- 19 Y3+ 7 SERTC+ 20 SERTC- 7 100 Ω term. 20 100 Ω term. 8 SERTFG- 21 SERTFG+ 8 Z0- 21 Z0+ 9 CC1- 22 CC1+ 9 Z1- 22 Z1+
10 CC2+ 23 CC2- 10 Z2- 23 Z2+ 11 CC3- 24 CC3+ 11 ZCLK- 24 ZCLK+ 12 CC4+ 25 CC4- 12 Z3- 25 Z3+
13 GND 26 GND 13 GND 26 GND
Power Supply Interface
®
Power Socket
Documentation and Software
Notice
The product documentation and software as well as accom­panying tools and applications notes can be obtained in the download area:
Pin Signal Pin Signal Pin Signal
1 (white) VCC 3 (green) STRB 5 (grey) GND
2 (brown) VCC 4 (yellow) DGND 6 (pink) GND
http://www.baumer.com/de-en/services/member-area
A registration is required.
Power Supply
Power VCC 8 VDC ... 24 VDC
W 5 W
Loading...