Bauknecht WGD97HEXL User Manual

Gas Dryer
4"
(102 mm)
2½"
(64 mm)
4" (102 mm)
4" (102 mm)
B
A
Number of 90 turns or elbows
Ty pe of vent
Box or Louvered hoods
Angled hoods
0
Rigid metal
64 ft (20 m)
58 ft (17.7 m)
1
54 ft (16.5 m)
48 ft (14.6 m)
2
44 ft (13.4 m)
38 ft (11.6 m)
3
35 ft (10.7 m)
29 ft (8.8 m)
4
27 ft (8.2 m)
21 ft (6.4 m)
Rigid metal
Rigid metal
Rigid metal
Rigid metal
o
Gas
61/4"
(159 mm)
29
7
/8"*
(759 mm)
3
1
/2"*
(89 mm)
53/4"*
(146 mm)
6
1
/8"*
(156 mm)
14
3
/8"
(365 mm)
253/4"
(654 mm)
311/8"
(790 mm)
50
7
/8"
(1292 mm)
Left or
right side
exhaust
31/2"
(89 mm)
10
1
/8"
(257 mm)
34" min.
(864 mm)
1"
(25 mm)
5"
(127 mm)
24 in.
2
(155 cm2)
48 in.
2
(310 cm2)
3"
(76 mm)
3"
(76 mm)
1"
(25 mm)
7"
(178 mm)
14"
(356 mm)
1"
(25 mm)
1"
(25 mm)
5"
(127 mm)
1"
(25 mm)
1"
(25 mm)
39" min.
(990 mm)
Gas
61/4"
(159 mm)
29
7
/8"*
(759 mm)
3
1
/2"*
(89 mm)
53/4"*
(146 mm)
6
1
/8"*
(156 mm)
14
3
/8"
(365 mm)
253/4"
(654 mm)
1"
(25 mm)
5"
(127 mm)
24 in.
2
(155 cm2)
48 in.
2
(310 cm2)
3"
(76 mm)
3"
(76 mm)
76
1
/4"*
(1936 mm)
6"
(152 mm)
1"
(25 mm)
PRODUCT MODEL NUMBERS WGD94HEX, WGD95HEX,
WGD97HEX, WGDXXHEX
Gas supply: This dryer is equipped for use with Natural
gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2" IPS. When acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1.
Electrical: A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit are recommended.
Water (Steam models only): The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten. Damage to the coupling can result.
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm) diameter vent is required. Rigid or exible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust.
Hood styles: A & B are recommended.
C
OVERALL DIMENSIONS
Dryer dimensions
A. Louvered hood B. Box hood C. Angled hood (acceptable)
The vent system chart provides venting requirments that will help to achieve the best drying performance.
Vent system chart: NOTE: Side and bottom exhaust installations have
a 90° turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart.
Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Use the fewest 90° turns possible.
Do not use vent runs longer than specied in vent length chart.
Determine the number of elbows you will need.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
Cabinet, Closet and Undercounter dimensions
For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings are acceptable.
For cabinet installation, with a door, the minimum ventilation openings in the top are required.
Ref. W10057364
10/10
Loading...