Bauknecht WEDXXHEX, WED95HEX, WED94HEX, WED97HEX User Manual

PRODUCT MODEL NUMBERS
27"
(686 mm)
3
/4"*
(18 mm)
38
1
/8"
(968 mm)
305/8"
(728 mm)
50
7
/8"
(1292 mm)
Left or
right side
exhaust
3
/4"*
(18 mm)
61/2"
(165 mm)
29
7
/8"*
(759 mm)
3
1
/2"*
(89 mm)
6
1
/8"*
(156 mm)
14
3
/8"
(365 mm)
3
/4"*
(18 mm)
18" min.
(457 mm)
1"
(25 mm)
5"
(127 mm)
24 in.2 min.
(155 cm2)
48 in.2 min.
(310 cm
2
)
3"
(76 mm)
3"
(76 mm)
1"
(25 mm)
WED94HEX, WED95HEX, WED97HEX, WEDXXHEX
Electrical: This dryer requires a 3 or 4 wire, single
phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specied on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
Water (Steam models only): The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten. Damage to the coupling can result.
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm) diameter vent is required. Rigid or exible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust.
Hood styles: A & B are recommended.
Electric Dryer Installation Instructions
OVERALL DIMENSIONS
Dryer dimensions
Front view:
Back view:
Side view:
NOTE: Most installations require a
minimum of 5" (127 mm) clearance behind dryer for exhaust vent with elbow. See “Venting Requirements.”
A
B
C
A. Louvered hood B. Box hood C. Angled hood (acceptable)
* Approximate measurement
The Vent system chart provides venting requirements that will help achieve best drying performance.
Closet installation (dryer only):
NOTE: Side and bottom exhaust installation have a 90°
turn inside the dryer. To determine maximum exhaust length, add a 90° turn to the total number of elbows when referemcing the chart.
Vent system chart
Number of 90° elbows
0
1
2
3
4
Do not use vent runs longer than specied in vent length chart.
Determine the number of elbows you will need.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Box/louvered
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
hoods
64 ft. (20 m)
27 ft. (8.2 m)
Angled
hoods
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings are acceptable.
Select the route that will provide the straightest and most direct path outdoors.
Plan the installation to use the fewest number of elbows and turns.
Use the fewest 90° turns possible.
Ref. W10057363B
12/2010