Battery Power Solutions freedom User Manual

USER’S MANUAL
Batteries to Power Your World!
Package Contents..........................................................................
Connection Components Sold Separately...................................
Product Specifications..................................................................
Safety Features.........................................................................
Charge Time..............................................................................
Life Span....................................................................................
Warranty....................................................................................
Intended Use..................................................................................
Compatibility..................................................................................
Average Run Times........................................................................
Getting Started
Initial Battery Usage.................................................................
Turning the Battery On/Off.......................................................
The Control Board.....................................................................
1
1
2
2
2
2
2
3
3
4
5
5
5
Charging the Battery.....................................................................
Charging in a Foreign Country...................................................
Single Battery Charging............................................................
Dual Battery Charging..............................................................
Other Charging Options................................................................
Auto Charge Cable....................................................................
150W Sine Wave Power Inverter...............................................
SunPower 40W Solar Panel.......................................................
6
6
6
7
8
8
8
8
Powering Your PAP Device
Respironics DreamStation Series..............................................
Respironics System One & M Series........................................
ResMed Air 10 & S9 Series.......................................................
ResMed S8 Series......................................................................
DeVilbiss IntelliPAP Series........................................................
Somnetics Transcend Series......................................................
HDM Z1 Series..........................................................................
Other PAP Devices....................................................................
Power Backup Usage.....................................................................
Air Travel Usage.............................................................................
Powering Other Devices...............................................................
USB Port Connection.................................................................
DC Input Cord Connection.........................................................
150W Sine Wave Inverter Connection......................................
9-10
11-12
13-15
16-17
18-19
20-21
22-23
24-25
26
26
27
27
28
28
Battery Care Instructions.............................................................
Battery Storage.............................................................................
FAQ/Troubleshooting....................................................................
Safety Warnings.............................................................................
Usage Disclaimer............................................................................
Battery Disposal.............................................................................
29
29
30-31
32
32
32
Package Contents
The FreedomTM CPAP Battery Kit comes with the items listed below.
FREEDOMTM CPAP BATTERY AC POWER SUPPLY DC POWER PIGTAIL CORD
CONNECTOR TIPS (3) DC INPUT CORD
NOTE: The included DC power pigtail cord and connector tips are compatible
with Respironics System One, Respironics M series and DeVilbiss IntelliPAP series devices. All other PAP device makes and models will require an additional connection component (see below).
Connection Components Sold Separately
The following items are required to connect certain PAP devices to the Freedom™ battery. These items are typically packaged separately and are not included in the FreedomTM CPAP Battery Kit box.
RESMED
24V POWER CONVERTER
{ITEM #: BPS C-24V-RES}
Required for ResMed
Air 10 and S9 devices.
DREAMSTATION
12V POWER ADAPTER
{ITEM #: BPS C-12V-DS}
Required for Respironics
DreamStation devices.
1
150W SINE WAVE POWER INVERTER
{ITEM #: BPS INVERTER}
Required for most all
other PAP device models.
Product Specifications
Cell Type: Industrial grade rechargeable lithium-ion
Capacity: 97.68 Wh
Output Voltage Range: 9V-12.6V DC
USB Output Voltage: 5V DC, 2A
Output Current: 8A maximum
Power Gauge: Digital display charge level indicator
Size: 7.5” x 4.8” x 0.8” (L x W x H)
Weight: 1.7 lbs
SAFETY FEATURES
Protective Circuit Board (PCB) provides internal protection against
thermal runaway (overheating), over charging, over discharging, over voltage, over current, and short circuiting.
Aluminum alloy shell provides maximum cell protection and durability.
The Freedom
all current safety regulations and shipping requirements.
TM
CPAP Battery has been UN 38.3 tested and meets
CHARGE TIME
The FreedomTM CPAP Battery can be charged in approximately 4 hours (per battery) when fully discharged. The battery does not need to be fully discharged before charging.
LIFE SPAN
Under normal conditions the average life span of the FreedomTM CPAP Battery is generally around 400-500 charge/discharge cycles. The amount of charge the battery will hold will gradually decrease due to usage and aging. This decrease in charge capacity is true for all rechargeable lithium­ion batteries. See page 29 for more information.
WARRANTY
The FreedomTM CPAP Battery, all components and accessories are under warranty for manufacturing and quality defects for one (1) year.
2
Intended Use
The FreedomTM CPAP Battery is intended to provide external battery power to PAP (positive airway pressure) devices when AC power is unavailable during travel or power outages.
The FreedomTM CPAP Battery can also be used to power or charge most common portable electronic devices such as cell phones and tablets.
Use of the battery with a device that has higher amperage requirements than the output of the battery (over 8A) may cause the internal circuitry of the battery to shut off to protect from thermal runaway.
Compatibility
All PAP device makes and models have different voltage and direct current capability requirements which determine the type of external battery that can be used.
The unique universal design of the FreedomTM CPAP Battery allows it to power most common PAP devices; however, some devices will require a device-specific connection component that is sold separately from the standard FreedomTM CPAP Battery Kit. See page 1 for more information.
Some older obsolete PAP devices and targeted ventilation PAP devices may not be compatible with or may require more power than the Freedom CPAP Battery can provide.
Reference the instructions in this manual for your specific PAP device to determine which connection components are required. Do not attempt
to connect your PAP device to the FreedomTM CPAP Battery before reading these connection instructions.
If connection instructions for your PAP device are not in this manual or you have any questions about connecting your device, please contact us at 1-877-445-5228 or via email at info@batterypowersolutions.net.
3
TM
Average Run Times
Multiple factors will affect how long the FreedomTM CPAP Battery will power a PAP device, including, but not limited to device type, pressure setting, altitude, humidifier usage, and the required connection component type.
BiLevel devices will have lower run times as the pressure setting is not constant and changes throughout the night requiring more power to operate the device.
The use of heated humidification and heated tubing will significantly reduce expected run times by up to two thirds in most cases and in some cases could prevent the battery from being able to power the PAP device. To obtain optimal battery performance we recommend you
forgo the use of heated humidification and heated tubing.
Average run times are based on standard CPAP devices without the use of heated humidification or heated tubing on a pressure setting of 10 cm/H2O. To increase average run times the battery can be used in a dual battery configuration by pigtailing two batteries together.
Respironics DreamStation Series
Single Battery: 1-2 nights Dual Batteries: 2-4 nights
Respironics System One & M Series
Single Battery: 1-3 nights Dual Batteries: 3-5 nights
DeVilbiss IntelliPAP Series
Single Battery: 1-3 nights Dual Batteries: 3-5 nights
Somnetics Transcend Series
Single Battery: 1-2 nights Dual Batteries: 2-4 nights
ResMed Air 10 & S9 Series
Single Battery: 1-2 nights Dual Batteries: 2-4 nights
ResMed S8 Series
Single Battery: 1 night Dual Batteries: 2 nights
HDM Z1 Series
Single Battery: 1-2 nights Dual Batteries: 2-4 nights
Most Other PAP Device Models
Single Battery: 1 night Dual Batteries: 2 nights
4
Getting Started
INITIAL BATTERY USAGE
Before using the FreedomTM CPAP Battery for the first time be sure to charge it fully. It may only take a short time for the battery charge level to reach 100% as it is already partially charged before it leaves the factory.
TURNING THE BATTERY ON/OFF
The FreedomTM CPAP Battery turns on and off automatically when a device is connected or disconnected from the DC OUT jack.
When connecting a device via the USB port, the charge level indicator button must be pressed once the device is connected in order to activate power output from the USB port. The battery will automatically shut off when the device is disconnected from the USB OUT port.
If the battery stops functioning press the charge level indicator button to reset the internal circuitry. See page 31 for additional information.
When not in use disconnect devices from the DC OUT jack or USB OUT port of the battery to allow the battery to completely shut down.
THE CONTROL BOARD
The FreedomTM CPAP Battery control board includes the DC IN and DC OUT jacks, USB OUT port, charge level indicator button, and digital display screen which displays the current charge level of the battery.
B
A
(A) DC IN JACK (B) CHARGE LEVEL INDICATOR BUTTON
(C) DIGITAL DISPLAY SCREEN (D) USB OUT PORT (E) DC OUT JACK
C
5
D
E
Charging the Battery
The FreedomTM CPAP Battery can be charged via a wall outlet using the included AC power supply in approximately 4 hours (per battery) when the battery is fully discharged.
CHARGING IN A FOREIGN COUNTRY
The AC power supply of the FreedomTM CPAP Battery will operate on any AC current from 100-240VAC and 50/60 Hz without any adjustment. An international electrical adapter plug is the only additional component that is required to charge the battery in a foreign country.
SINGLE BATTERY CHARGING
Connect the AC power cord to the AC power supply.
Plug the AC power supply into the DC IN jack of the battery.
Plug the AC power supply into a wall outlet.
The digital display screen will show the charge level of the battery.
You may press the charge level indicator button to illuminate this screen for a few seconds at a time.
When charging is complete disconnect the AC power supply from the
wall outlet and the battery.
Note: It is normal for the AC power supply and the battery to be slightly warm to the touch during the charging process.
AC POWER CORD
AC POWER SUPPLY
DC IN JACK
6
Charging the Battery
DUAL BATTERY CHARGING
Connect the AC power cord to the AC power supply.
Plug the AC power supply into the DC power pigtail cord.
Plug the DC power pigtail cord into the DC IN jacks of both batteries.
Plug the AC power supply into a wall outlet.
The digital display screen will show the charge level of the battery.
You may press the charge level indicator button to illuminate this screen for a few seconds at a time.
When charging is complete disconnect the AC power supply from the
wall outlet and the battery.
Note: It is normal for the AC power supply and the batteries to be slightly warm to the touch during the charging process.
AC POWER CORD
AC POWER SUPPLY
DC IN JACKS
7
DC POWER PIGTAIL CORD
Other Charging Options
When AC power is not available you can still keep the FreedomTM CPAP Battery charged up and ready to go. Optional accessories are available for charging the battery in a vehicle or by using the power of the sun. For more detailed information on these charging accessories visit our website at www.batterypowersolutions.net or call us at 1-877-445-5228.
AUTO CHARGE DC CABLE
The auto charge DC cable lets you connect the battery directly to the cigarette lighter/power socket of a vehicle. The vehicle must be running during the charging process in order to obtain the proper voltage to successfully charge the battery. We do not recommend using any other
brand of “universal” auto charge cable as it may damage the internal circuitry of the Freedom™ CPAP Battery.
150W SINE WAVE POWER INVERTER
The 150W sine wave power inverter lets you charge the battery via the cigarette lighter/power socket of a vehicle by plugging the battery AC power supply into the inverter and then plugging the inverter into the vehicle. The vehicle does not need to be running during the charging process to obtain the proper voltage to successfully charge the battery.
SUNPOWER 40W SOLAR PANEL
The SunPower 40W solar panel lets you use the power of the sun to charge the battery. The solar panel also comes with a DC input cord so you can charge other small electronic devices that operate from 18V or less by using the device’s DC power cord.
AUTO CHARGE DC CABLE
{ITEM #: BPS DC.CABLE}
150W SINE WAVE POWER INVERTER
{ITEM #: BPS INVERTER}
8
SUNPOWER 40W
SOLAR PANEL
{ITEM #: BPS SP40}
Respironics DreamStation Series Devices
The DC input port on Respironics DreamStation series devices require a proprietary signal in order to recognize a valid power source; therefore, the use of a 12V power adapter is required in conjunction with the FreedomTM CPAP Battery.
Our 12V power adapter was designed specifically for use with Respironics DreamStation series devices and the FreedomTM CPAP Battery.
REQUIRED COMPONENTS
Freedom
DreamStation 12V Power Adapter
SINGLE BATTERY CONNECTION
Plug the 12V power adapter into the DC OUT jack of the battery.
Plug the 12V power adapter into the DC input port of the PAP device.
Turn the PAP device on and it should begin functioning.
TM
CPAP Battery Kit
The digital display screen will show the charge level of the battery.
You may press the charge level indicator button to illuminate this screen. It will stay illuminated for a few seconds at a time.
12V POWER
ADAPTER
PAP DC INPUT PORT
DC OUT JACK
9
Respironics DreamStation Series Devices
DUAL BATTERY CONNECTION
Dual battery connection will require an additional FreedomTM CPAP Battery.
Plug the 12V power adapter into the DC power pigtail cord.
Plug the DC power pigtail cord into the DC OUT jacks of both batteries.
Plug the 12V power adapter into the DC input port of the PAP device.
Turn the PAP device on and it should begin functioning.
The digital display screen will show the charge level of the battery.
You may press the charge level indicator button to illuminate this screen. It will stay illuminated for a few seconds at a time.
DC OUT JACKS
12V POWER ADAPTER
DC POWER
PIGTAIL CORD
PAP DC INPUT PORT
10
Respironics System One & M Series Devices
Respironics System One and M series devices can be connected directly to the FreedomTM CPAP Battery using the DC power pigtail cord and the appropriate connector tip included in the FreedomTM CPAP Battery Kit.
REQUIRED COMPONENTS
Freedom
SINGLE BATTERY CONNECTION
Plug the DC power pigtail cord into the DC OUT jack of the battery.
Insert the appropriate connector tip into the DC power pigtail cord.
System One 60 Series: Tip with black top labeled “W”
System One 50 & M Series: Tip with yellow top labeled “N”
Plug the DC power pigtail cord with appropriate connector tip attached
into the DC input port of the PAP device.
Turn the PAP device on and it should begin functioning.
TM
CPAP Battery Kit
The digital display screen will show the charge level of the battery.
You may press the charge level indicator button to illuminate this screen. It will stay illuminated for a few seconds at a time.
CONNECTOR TIP
Image shows connection to Respironics System One 60 series PAP device.
INSERTED INTO PAP
DC INPUT PORT
11
DC OUT JACK
DC POWER PIGTAIL CORD
Respironics System One & M Series Devices
DUAL BATTERY CONNECTION
Dual battery connection will require an additional FreedomTM CPAP Battery.
Plug the DC power pigtail cord into the DC OUT jacks of both batteries.
Insert the appropriate connector tip into the DC power pigtail cord.
System One 60 Series: Tip with black top labeled “W”
System One 50 & M Series: Tip with yellow top labeled “N”
Plug the DC power pigtail cord with appropriate connector tip attached
into the DC input port of the PAP device.
Turn the PAP device on and it should begin functioning.
The digital display screen will show the charge level of the battery.
You may press the charge level indicator button to illuminate this screen. It will stay illuminated for a few seconds at a time.
CONNECTOR TIP
INSERTED INTO PAP
DC INPUT PORT
Image shows connection to Respironics System One 60 series PAP device.
DC OUT JACKS
12
DC POWER PIGTAIL CORD
ResMed Air 10 & S9 Series Devices
ResMed Air 10 and S9 series devices operate from 24V direct current and the FreedomTM CPAP Battery provides 12V direct current; therefore, the use of a 24V power converter is required in conjunction with the battery.
Our 24V power adapter was designed specifically for use with ResMed Air 10 and S9 series devices and the FreedomTM CPAP Battery.
REQUIRED COMPONENTS
Freedom
ResMed 24V Power Converter
24V RESMED POWER CONVERTER
The 24V power converter includes the converter box and two output cords. Each output cord has a tag attached to it noting which device it fits ­either ResMed Air 10 or ResMed S9 series devices.
Set the converter box and the appropriate output cord for your device aside. Do not connect the output cord to the converter box yet as the converter box must be connected to the Freedom™ battery first. See the connection instructions on the following pages.
TM
CPAP Battery Kit
S9 SERIES
OUTPUT CORD
CONVERTER BOX
AIR 10 SERIES
OUTPUT CORD
13
ResMed Air 10 & S9 Series Devices
The steps below must be followed in exact sequence in order to initiate the voltage conversion process and thus allow the FreedomTM CPAP Battery to power the device. After connection if you are not receiving power to the device unplug all components and follow the instructions again.
SINGLE BATTERY CONNECTION
Plug the 24V power converter box into the DC OUT jack of the battery.
Insert the appropriate output cord for your device (Air 10 or S9) into
the power converter box.
Plug the 24V power converter with appropriate output cord attached
into the DC input port of the PAP device.
Turn the PAP device on and it should begin functioning.
The digital display screen will show the charge level of the battery.
You may press the charge level indicator button to illuminate this screen. It will stay illuminated for a few seconds at a time.
DC OUT JACK
Image shows connection to a ResMed Air 10 series PAP device.
14
24V POWER CONVERTER
PAP DC
INPUT PORT
ResMed Air 10 & S9 Series Devices
The steps below must be followed in exact sequence in order to initiate the voltage conversion process and thus allow the FreedomTM CPAP Battery to power the device. After connection if you are not receiving power to the device unplug all components and follow the instructions again.
DUAL BATTERY CONNECTION
Dual battery connection will require an additional FreedomTM CPAP Battery.
Plug the DC power pigtail cord into the DC OUT jacks of both batteries.
Plug the 24V power converter box into the DC power pigtail cord.
Insert the appropriate output cord for your device (Air 10 or S9) into
the power converter box.
Plug the 24V power converter with appropriate output cord attached
into the DC input port of the PAP device.
Turn the PAP device on and it should begin functioning.
The digital display screen will show the charge level of the battery.
You may press the charge level indicator button to illuminate this screen. It will stay illuminated for a few seconds at a time.
DC OUT JACKS
DC POWER PIGTAIL CORD
Image shows connection to a ResMed Air 10 series PAP device.
15
PAP DC
INPUT PORT
24V POWER CONVERTER
ResMed S8 Series Devices
Although ResMed S8 series devices operate from 12V DC the DC input ports run opposite polarity from the FreedomTM CPAP Battery; therefore, the use of the 150W sine wave power inverter is required in conjunction with battery. DO NOT connect a ResMed S8 device to the battery
without using the sine wave power inverter as doing so will cause irreversible damage to the PAP device.
REQUIRED COMPONENTS
Freedom
150W Sine Wave Power Inverter (power inverter)
SINGLE BATTERY CONNECTION
Plug the DC input cord into the DC OUT jack of the battery.
Plug the power inverter into the DC input cord.
Plug the AC power cord of the PAP device into the power inverter.
Plug the AC power cord into the PAP device.
TM
CPAP Battery Kit
Turn the PAP device on and it should begin functioning.
The digital display screen will show the charge level of the battery.
You may press the charge level indicator button to illuminate this screen. It will stay illuminated for a few seconds at a time.
PAP AC POWER CORD
DC OUT JACK
16
DC INPUT CORD
150W SINE WAVE POWER INVERTER
ResMed S8 Series Devices
Although ResMed S8 series devices operate from 12V DC the DC input ports run opposite polarity from the FreedomTM CPAP Battery; therefore, the use of the 150W sine wave power inverter is required in conjunction with battery. DO NOT connect a ResMed S8 device to the battery
without using the sine wave power inverter as doing so will cause irreversible damage to the PAP device.
DUAL BATTERY CONNECTION
Dual battery connection will require an additional FreedomTM CPAP Battery.
Plug the DC power pigtail cord into the DC OUT jacks of both batteries.
Plug the DC input cord into the DC power pigtail cord.
Plug the power inverter into the DC input cord.
Plug the AC power cord of the PAP device into the power inverter.
Plug the AC power cord into the PAP device.
Turn the PAP device on and it should begin functioning.
The digital display screen will show the charge level of the battery.
You may press the charge level indicator button to illuminate this screen. It will stay illuminated for a few seconds at a time.
PAP AC POWER CORD
150W SINE WAVE POWER INVERTER
DC POWER
PIGTAIL CORD
DC OUT JACKS
1718
DC INPUT CORD
DeVilbiss IntelliPAP Series Devices
DeVilbiss IntelliPAP series devices can be connected directly to the FreedomTM CPAP Battery using the DC power pigtail cord and appropriate connector tip included in the FreedomTM CPAP Battery Kit.
REQUIRED COMPONENTS
Freedom
SINGLE BATTERY CONNECTION
Plug the DC power pigtail cord into the DC OUT jack of the battery.
Insert the connector tip with blue top labeled “J” into the DC power
pigtail cord.
Plug the DC power pigtail cord with “J” connector tip attached into the
DC input port of the PAP device.
Turn the PAP device on and it should begin functioning.
The digital display screen will show the charge level of the battery.
You may press the charge level indicator button to illuminate this screen. It will stay illuminated for a few seconds at a time.
TM
CPAP Battery Kit
CONNECTOR TIP INSERTED
INTO PAP DC INPUT PORT
DC OUT JACK
DC POWER PIGTAIL CORD
DeVilbiss IntelliPAP Series Devices
DUAL BATTERY CONNECTION
Dual battery connection will require an additional FreedomTM CPAP Battery.
Plug the DC power pigtail cord into the DC OUT jacks of both batteries.
Insert the connector tip with blue top labeled “J” into the DC power
pigtail cord.
Plug the DC power pigtail cord with “J” connector tip attached into the
DC input port of the PAP device.
Turn the PAP device on and it should begin functioning.
The digital display screen will show the charge level of the battery.
You may press the charge level indicator button to illuminate this screen. It will stay illuminated for a few seconds at a time.
CONNECTOR TIP INSERTED
INTO PAP DC INPUT PORT
DC OUT JACKS
DC POWER PIGTAIL CORD
19
Somnetics Transcend Series Devices
Somnetics Transcend series devices can be connected to the Freedom™ CPAP Battery via the 150W sine wave power inverter.
REQUIRED COMPONENTS
Freedom
150W Sine Wave Power Inverter (power inverter)
Due to the initial power draw required to start the device the connection instructions below must be followed in exact sequence in order to
prevent “tripping” the internal circuitry of the battery. If the battery does shut down disconnect all components, press the charge level indicator button to reset the battery and follow the instructions in exact sequence.
SINGLE BATTERY CONNECTION
Plug the DC input cord into the DC OUT jack of the battery.
Plug the power inverter into the DC input cord.
TM
CPAP Battery Kit
Plug the AC power supply of the PAP device into the power inverter.
Plug the AC power supply into the PAP device.
Turn the PAP device on and it should begin functioning.
The digital display screen will show the charge level of the battery.
You may press the charge level indicator button to illuminate this screen. It will stay illuminated for a few seconds at a time.
150W SINE WAVE POWER INVERTER
DC OUT JACK
PAP AC
POWER SUPPLY
20
DC INPUT CORD
Somnetics Transcend Series Devices
Due to the initial power draw required to start the device the connection instructions below must be followed in exact sequence in order to
prevent “tripping” the internal circuitry of the battery. If the battery does shut down disconnect all components, press the charge level indicator button to reset the battery and follow the instructions in exact sequence.
DUAL BATTERY CONNECTION
Dual battery connection will require an additional FreedomTM CPAP Battery.
Plug the DC power pigtail cord into the DC OUT jacks of both batteries.
Plug the DC input cord into the DC power pigtail cord.
Plug the power inverter into the DC input cord.
Plug the AC power supply of the PAP device into the power inverter.
Plug the AC power supply into the PAP device.
Turn the PAP device on and it should begin functioning.
The digital display screen will show the charge level of the battery.
You may press the charge level indicator button to illuminate this screen. It will stay illuminated for a few seconds at a time.
PAP AC
POWER SUPPLY
150W SINE WAVE
POWER INVERTER
DC INPUT
CORD
PIGTAIL CORD
21
DC POWER
DC OUT JACKS
HDM Z1 Series Devices
HDM Z1 series devices can be connected to the Freedom™ CPAP Battery via the 150W sine wave power inverter.
REQUIRED COMPONENTS
Freedom
150W Sine Wave Power Inverter (power inverter)
Due to the initial power draw required to start the device the connection instructions below must be followed in exact sequence in order to
prevent “tripping” the internal circuitry of the battery. If the battery does shut down disconnect all components, press the charge level indicator button to reset the battery and follow the instructions in exact sequence.
SINGLE BATTERY CONNECTION
Plug the DC input cord into the DC OUT jack of the battery.
Plug the power inverter into the DC input cord.
TM
CPAP Battery Kit
Plug the AC power supply of the PAP device into the power inverter.
Plug the AC power supply into the PAP device.
Turn the PAP device on and it should begin functioning.
The digital display screen will show the charge level of the battery.
You may press the charge level indicator button to illuminate this screen. It will stay illuminated for a few seconds at a time.
PAP AC POWER SUPPLY
150W SINE WAVE POWER INVERTER
22
DC INPUT CORD
DC OUT JACK
HDM Z1 Series Devices
Due to the initial power draw required to start the device the connection instructions below must be followed in exact sequence in order to
prevent “tripping” the internal circuitry of the battery. If the battery does shut down disconnect all components, press the charge level indicator button to reset the battery and follow the instructions in exact sequence.
DUAL BATTERY CONNECTION
Dual battery connection will require an additional FreedomTM CPAP Battery.
Plug the DC power pigtail cord into the DC OUT jacks of both batteries.
Plug the DC input cord into the DC power pigtail cord.
Plug the power inverter into the DC input cord.
Plug the AC power supply of the PAP device into the power inverter.
Plug the AC power supply into the PAP device.
Turn the PAP device on and it should begin functioning.
The digital display screen will show the charge level of the battery.
You may press the charge level indicator button to illuminate this screen. It will stay illuminated for a few seconds at a time.
PAP AC
POWER SUPPLY
POWER INVERTER
DC INPUT
CORD
SINE WAVE
23
DC POWER
PIGTAIL CORD
DC OUT JACKS
Other PAP Device Models
Most other PAP device models including Fisher & Paykel ICON series, 3B Medical RESmart and Luna series, and Apex Medical XT series devices can be connected to the Freedom™ CPAP Battery via the 150W sine wave power inverter.
REQUIRED COMPONENTS
Freedom
150W Sine Wave Power Inverter (power inverter)
SINGLE BATTERY CONNECTION
Plug the DC input cord into the DC OUT jack of the battery.
Plug the power inverter into the DC input cord.
Plug the AC power supply of the PAP device into the power inverter.
Plug the AC power supply into the PAP device.
Turn the PAP device on and it should begin functioning.
TM
CPAP Battery Kit
The digital display screen will show the charge level of the battery.
You may press the charge level indicator button to illuminate this screen. It will stay illuminated for a few seconds at a time.
Image shows connection to Fisher & Paykel ICON series PAP device.
PAP AC POWER SUPPLY
150W SINE WAVE POWER INVERTER
DC OUT JACK
24
DC INPUT CORD
Other PAP Device Models
DUAL BATTERY CONNECTION
Dual battery connection will require an additional FreedomTM CPAP Battery.
Plug the DC power pigtail cord into the DC OUT jacks of both batteries.
Plug the DC input cord into the DC power pigtail cord.
Plug the power inverter into the DC input cord.
Plug the AC power supply of the PAP device into the power inverter.
Plug the AC power supply into the PAP device.
Turn the PAP device on and it should begin functioning.
The digital display screen will show the charge level of the battery.
You may press the charge level indicator button to illuminate this screen. It will stay illuminated for a few seconds at a time.
Image shows connection to Fisher & Paykel ICON series PAP device.
DC POWER
PIGTAIL CORD
DC OUT JACKS
DC INPUT CORD
25
PAP AC POWER SUPPLY
150W SINE WAVE POWER INVERTER
Power Backup Usage
The FreedomTM CPAP Battery can be used as a backup power supply for your PAP device during power outages. You may leave your PAP device connected to the battery when you sleep and in the event AC power is lost the battery will automatically begin powering your PAP device.
Plug the battery into the wall outlet as if you were charging it.
Connect the PAP device to the battery via the instructions in this manual
for your specific device.
When AC power is available it will bypass the lithium-ion cells of the
battery thus preventing unnecessary cycling of the cells. In the event AC power is lost the battery will recognize this lack of power flow and automatically begin powering your PAP device uninterrupted.
When you are not using your PAP device disconnect it from the
DC OUT jack of the battery and unplug the battery from the wall outlet so the battery can completely shut down.
If using in the dual battery configuration an additional DC power pigtail
cord will be required as one is needed to plug the batteries into the wall outlet and the other to connect the batteries to the PAP device.
Air Travel Usage
The FreedomTM CPAP Battery meets current FAA requirements for spare lithium-ion batteries (batteries not installed in a device) taken in carry-on baggage as each battery is less than 100 Wh (97.68 Wh) and is protected from damage and short circuit.
Spare lithium-ion batteries are not allowed in checked baggage and must only be taken in carry-on baggage. TSA security, individual airline, and international rules may, at times, be more restrictive.
If you are planning to use the battery during flight it is recommended that you contact your airline as they may have specific requirements regarding the use of PAP devices and/or lithium-ion batteries during flight.
26
Powering Other Devices
The FreedomTM CPAP Battery can be used to power many common handheld electronic devices such as cell phones, iPods, MP3 players, and tablets via the 5V USB port or DC input cord.
USB PORT CONNECTION
Plug the device’s USB cord into the USB OUT port of the battery.
Press the charge level indicator button once to initiate power output
from the USB OUT port.
Turn the device on and it should begin functioning.
The digital display screen will show the charge level of the battery.
You may press the charge level indicator button to illuminate this screen. It will stay illuminated for a few seconds at a time. Pressing this button again will not turn the battery off it will simply illuminate the display screen.
When not in use disconnect all devices from the battery thus allowing
the battery to completely shut down.
USB OUT PORT
CHARGE LEVEL INDICATOR BUTTON
DEVICE USB CORD
It is possible to have a portable electronic device and a PAP device connected to the Freedom™ battery simultaneously; however, this could impact PAP device run times.
27
Powering Other Devices
DC INPUT CORD CONNECTION
Plug the DC input cord into the DC OUT jack of the battery.
Plug the device’s DC power cord into the DC input cord.
Turn the device on and it should begin functioning.
The digital display screen will show the charge level of the battery.
You may press the charge level indicator button to illuminate this screen. It will stay illuminated for a few seconds at a time.
When not in use disconnect all devices from the battery thus allowing
the battery to completely shut down.
DC OUT JACK
DC INPUT CORD
DEVICE DC POWER CORD
150W SINE WAVE POWER INVERTER CONNECTION
You can also connect other small electronic devices that do not have a USB cord or DC power cord by using the 150W sine wave power inverter in conjunction with the battery.
In this setup you connect the device’s AC power cord to the inverter and then connect the inverter to the battery via the DC input cord.
28
Battery Care Instructions
Understanding common phenomenon with rechargeable lithium-ion batteries can help you better care for your FreedomTM CPAP Battery and answer many common questions regarding usage.
Lithium-ion batteries do not suffer from the memory effects that are
associated with other types of battery chemistries. This means that the battery does not need to be completely discharged before charging.
Upon initial use or after a prolonged storage period lithium-ion
batteries may require 3-4 charge/discharge cycles before achieving their maximum capacity.
Lithium-ion batteries will self-discharge when unused; therefore,
the battery will need to be charged after a storage period. On average the battery will self-discharge by 20% every 30 days.
The amount of charge lithium-ion batteries will hold will gradually
decrease due to usage and aging. Over time, the actual battery capacity decreases as less and less active material within each lithium-ion cell is available to electrochemically store a charge. This loss in capacity (aging) is true for all rechargeable lithium-ion batteries.
It is normal for a lithium-ion battery and its AC power supply to
become slightly warm to the touch during charging and discharging.
Battery Storage
Fully charge the battery before storage.
Store the battery in a dry, cool place away from extreme heat, direct
sunlight and metal objects.
If the battery is being stored for long periods of time we recommend
charging the battery to 50% of capacity at least once every 90 days.
29
FAQ | Troubleshooting
Below are the most common questions/issues regarding use of the FreedomTM CPAP Battery. If you have additional questions please contact us at 877-445-5228 or email us at info@batterypowersolutions.net.
LOWER THAN EXPECTED RUN TIMES
Several factors can impact how long the battery will power a PAP device. Below are the most common of these factors:
The use of heated humidification or heated tubing will reduce run times
by two thirds in most cases and in some cases could prevent the battery from being able to power the PAP device. You should disconnect the humidifier or completely turn it off and use non-heated tubing to obtain optimal battery performance.
If humidification is required, try lowering the humidification setting as many people can lower their heat setting and still achieve the desired result. If lowering the setting does not produce enough of an increase in run time you can use the battery in the dual battery configuration to increase the run time.
Very high pressure settings (above 18 cm/H2O) can impact run times
especially when other factors are present. All average run time testing is done on a pressure setting of 10 cm/H2O.
Leaking masks can impact run times as the PAP device will be working
harder to maintain the prescribed pressure setting and thus be drawing more power from the battery.
BiLevel devices will have lower run times as the pressure setting is
not constant and changes throughout the night requiring more power to operate the device.
Some older obsolete PAP device models and newer targeted ventilation
PAP devices require a much higher power draw than today’s standard CPAP devices and therefore can result in lower run times or could prevent the battery from being able to power the device.
The device-specific connection components required for some PAP
device models do draw power from the battery but this has been factored into the listed average run times.
30
FAQ | Troubleshooting
BATTERY STARTS THEN STOPS WORKS
If the battery stops functioning press the charge level indicator button to reset the batteries’ internal circuitry. If the battery continues to shut down, the device you are attempting to power may not be compatible.
The device may have higher amperage requirements (over 8A) than
the battery can provide.
The device may require a constant voltage output to operate properly.
The FreedomTM CPAP battery has a voltage range of 9V-12.6V DC and does not maintain a constant voltage level.
The internal circuitry of the device may be set to automatically adjust
to accommodate for multi-voltage capabilities which could make it compatible with the battery at times and incompatible at other times.
DUAL BATTERY CONFIGURATION
While both batteries are providing output power simultaneously the battery with the highest charge level will generally be the one to display “DC 12V” under the battery symbol on the digital display screen.
Also note that due to the circuit board differences a Freedom™ CPAP Battery cannot be pigtailed with an older model C-100 CPAP Battery.
USB PORT CONNECTION
When connecting a device to the USB port you must press the charge level indicator button once to initiate output power from the battery. See page 27 for connection instructions.
PAP DEVICE CONNECTION VIA A 12V DC POWER CORD
While you can connect a PAP device to the battery using a manufacturer’s 12V DC power cord and the DC input cord included with the battery kit it may only power the PAP device for a short period of time. This occurs because these types of DC power cords typically require a constant 12V power flow in order to work properly and the Freedom™ battery functions on a voltage range. Therefore, 12V DC power cords are not a viable option for connecting a PAP device to the Freedom™ battery.
31
Safety Warnings
The following safety warnings must be observed at all times:
Do not drop, hit, crush, or otherwise abuse the battery as this
may result in the exposure of the cell contents, which are corrosive.
Do not expose the battery to rain or moisture of any type.
Do not expose the battery to fire, incineration or other extreme heat.
Exposure to extreme heat may result in a hazardous reaction.
Do not disassemble the battery (remove the cover) or attempt to
repair the battery as there are no user-serviceable parts inside.
Periodically inspect connection cords, connector tips and the power
supply for damage or signs of wear. Discontinue use if damaged.
Usage Disclaimer
By purchasing, using or possessing any of Battery Power Solutions’ products, you are agreeing to hold harmless Battery Power Solutions, it’s subsidiaries, affiliates, owners, officers and employees from any and all claims or liability for any damage to any property or injury, illness or death of any person when such damage, injury, illness or death shall be caused in whole or in part from use of the product(s).
Battery Disposal
Lithium-ion batteries should be recycled. Some states have specific laws regarding the disposal of lithium-ion batteries. For information on laws in your state and where you can recycle your batteries at no cost, visit www.call2recycle.org or call 1-877-723-1297.
32
1-877-445-5228 www.batterypowersolutions.net
FREEDOMTM CPAP BATTERY USER’S MANUAL
OCTOBER 2016
Loading...