The mechanical detail is shown in Fig. 1(b) and summarized in Table 1 below.
Table 1
Parameter Specifications Unit
Outline dimensions 84.0(W) x 44.0(H) x 10.0 MAX.(D) mm
Effective viewing area 61.0(W) x 15.8(H) mm
Display format 16 characters x 2 lines Character size 2.95(W) x 5.55(H) (5 x 8 dots ) mm
Character spacing 0.60(W) x 0.40(H) mm
Character pitch 3.55(W) x 5.95(H) mm
Dot size 0.578(W) x 0.681(H) mm
Dot spacing 0.015(W) x 0.015(H) mm
Dot pitch 0.593(W) x 0.696(H) mm
Weight TBDgrams
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
VL-FS-BTHQ 21605VSS-01 REV. B
(BT 21605VSS-SRE-HQ)
JULY/2003
PAGE5OF
14
Figure 1(a): Outline Drawing
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
VL-FS-BTHQ 21605VSS-01 REV. B
(BT 21605VSS-SRE-HQ)
JULY/2003
PAGE6OF
14
Figure 1(b): Outline Drawing
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
VL-FS-BTHQ 21605VSS-01 REV. B
A
H
V
H
(BT 21605VSS-SRE-HQ)
JULY/2003
PAGE7OF
14
3. Absolute Maximum Ratings
3.1 Electrical Maximum Ratings (Ta = 25 ºC)
Table 3
ParameterSymbolMin.Max.Unit
Power Supply voltage (Logic)VDD - VSS-0.3 +7.0V
Power Supply voltage (LCD drive)VLCD=VDD – V0-0.3+15.0V
Input voltageVin-0.3VDD+0.3V
Note:
The modules may be destroyed if they are used beyond the absolute maximum ratings.
All voltage values are referenced to VSS = 0V.
3.2 Environmental Condition
Operating
Item
Temperature
(Topr)
Min.Max.Min.Max.
mbient Temperature
umidity
0qC+50qC-10qC+60qC
95% max. RH for Ta d 40qC
< 95% RH for Ta > 40qC
ibration (IEC 68-2-6)
cells must be mounted
on a suitable connector
Shock (IEC 68-2-27)
alf-sine pulse shape
Frequency: 10 a 55 Hz
Amplitude: 0.75 mm
Duration: 20 cycles in each direction.
Pulse duration: 11 ms
Peak acceleration: 981 m/s2= 100g
Number of shocks: 3 shocks in 3
mutually perpendicular axes.
Table 4
Storage
Temperature
(Tstg)
Remark
Dry
no condensation
3 directions
3 directions
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
VL-FS-BTHQ 21605VSS-01 REV. B
(BT 21605VSS-SRE-HQ)
JULY/2003
PAGE8OF
4. Interface signals
Table 2
Pin No. Symbol Description
1VSSGround (0V).
2VDDPower supply for logic (+5V)
3V0Power supply for LCD driver
4RSRegister Select Input:
“High” for Data register (for read and write)
“Low” for Instruction register (for write),
Busy flag, address counter (for read)
5R/W Read/Write signal:
“High” for Read mode.
“Low” for Write mode.
6EEnable.
Start signal for data read /write.
7DB0Data input/output (LSB)
8DB1Data input/output
9DB2Data input/output
10DB3Data input/output
11 DB4Data input/output
12DB5Data input/output
13DB6Data input/output
14DB7Data input/output (MSB)
15LED(+)Anode of LED backlight
16LED(-)Cathode of LED backlight
14
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
VL-FS-BTHQ 21605VSS-01 REV. B
(BT 21605VSS-SRE-HQ)
JULY/2003
PAGE9OF
14
4. Electrical Specifications
4.1 Typical Electrical Characteristics
At Ta = 25 qC, VDD = 5Vr5%, VSS=0V.
Table 5
Parameter Symbol ConditionsMin.Typ. Max.Unit
Supply voltage (Logic) VDD-VSS4.755.05.25V
Supply voltage (LCD) VLCD
=VDD-V0
Input signal voltage 1
for E,DB0-DB7,R/W,RS
Input signal voltage 2
V
V
V
IH1
IL1
IH2
VDD = 5V,
4.14.65.1V
Note 1
“High” level 2.2-VDDV
“Low” level -0.3-0.6V
“High” level VDD
-VDDV
-1.0
for OSC1
(Logic & LCD)
V
IL2
IDD
“Low” level --1.0V
Character mode,
-1.11.7mA Supply Current
Note 1
Checkerboard
1.21.8mA
mode, Note 1
Character mode,
-0.20.3mA Supply Current (LCD) I0
Note 1
Checkerboard
-0.20.3mA
mode, Note 1
Note 1 : There is tolerance in optimum LCD driving voltage during production and it will be within
the specified range.
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
VL-FS-BTHQ 21605VSS-01 REV. B
(BT 21605VSS-SRE-HQ)
JULY/2003
PAGE10OF
4.2 Timing Specifications
At Ta = 0 qC To +50 qC, VDD = +5Vr5%, VSS = 0V.
Refer to Fig. 2, the bus timing diagram for write mode.
Table 6
Parameter Symbol Min.Max.UnitTest pin
E cycle time t
E rise time t
E fall time t
E pulse width (High, Low) t
R/W and RS set-up time t
R/W and RS hold time t
Data set-up time t
Data hold time t
Refer to Fig. 3, the bus timing diagram for read mode.
Table 7
Parameter Symbol Min.Max.UnitTest pin
E cycle time t
E rise time t
E fall time t
E pulse width t
R/W and RS set-up time t
R/W and RS hold time t
Data output delay time t
Data hold time t
C
R
F
W
SU
H
D
DH
500-nsE
-25nsE
-25nsE
220-nsE
40-nsR/W,RS
10-nsR/W, RS
-120nsDB0-DB7
20-nsDB0-DB7
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
VL-FS-BTHQ 21605VSS-01 REV. B
(BT 21605VSS-SRE-HQ)
JULY/2003
PAGE11OF
14
Figure 2: The bus timing diagram for write mode .
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
VL-FS-BTHQ 21605VSS-01 REV. B
(BT 21605VSS-SRE-HQ)
JULY/2003
PAGE12OF
14
Figure 3: The bus timing diagram for read mode .
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
VL-FS-BTHQ 21605VSS-01 REV. B
(BT 21605VSS-SRE-HQ)
JULY/2003
PAGE13OF
14
4.3 Timing Diagram of VDD against V0.
Power on sequence shall meet the requirement of Figure 4, the timing diagram of VDD against V0.
Figure 4: Timing diagram of VDD against V0.
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
VL-FS-BTHQ 21605VSS-01 REV. B
(BT 21605VSS-SRE-HQ)
JULY/2003
PAGE14OF
5.CGROM Character Code Table (KS0070B-00)