Datasheet BT 21605AVB-03 Datasheet (BATRON)

BA TRON
BT 21605AVB-YETF-LED04-I2C(HD66717)
Dec/2001
1/15
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
BT 21605AVB-YETF-LED04-I2C(HD66717)
BA TRON
SPECIFICATION
LCD MODULE TYPE
2/15
FOR
ITEM NO.: BT 21605AVB-03
BT 21605AVB-YETF-LED04-I2C(HD66717)
WITHOUT CONNECTOR
(DOC. REVISION 0.0)
DEPARTMENT NAME SIGNATURE EFFECTIVE DATE
PREPARED BY PHILIP CHENG 2000.11.03
APPROVED BY K.P.HO 2000.11.03
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
BA TRON
BT 21605AVB-YETF-LED04-I2C(HD66717)
DOCUMENT REVISION HISTORY
3/15
DOCUMENT
REVISION
FROM TO
DATE
(YY.MM.DD)
0.0 2000.11.03
DESCRIPTION CHANGED
BY
PHILIP
CHECKED
BY
JOE LAM
CHENG
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
BA TRON
BT 21605AVB-YETF-LED04-I2C(HD66717)
CONTENT
1. GENERAL DESCRIPTION .............................................................................. P.1
2. MECHANICAL SPECIFICATIONS ................................................................. P.1
3. ABSOLUTE MAXIMUM RATINGS .....................................................…….. P.4
3.1 ELECTRICAL MAXIMUM RATINGS (Ta=+25°C) .....................…….. P.4
3.2 ENVIRONMENTAL CONDITION .................................................……. P.4
4. ELECTRICAL SPECIFICATIONS ............................................................….. P.5
4.1 INTERFACE SIGNALS ........................................................................... P.5
4.2 TYPICAL ELECTRICAL CHARACTERISTICS ……………………..… P.6
4/15
4.3 TIMING SPECIFICATIONS……………………………………………… P.7
4.4 RELATION BETWEEN CHARACTER CODES AND CHARACTER PATTERNS (ROM CODE: A03) ………………………………………… P.9
4.5 SLAVE ADDRESS SELECTABLE (JUMPER SET)….……………….… P.10
4.6 I SELECTABLE………………………………………………………….… P.10
4.7 EXTERNAL OR INTERNAL VLCD SELECTABLE…………………… P.10
4.8 TIMING DIAGRAM OF VDDAGAINST V5………..…….……………… P.11
2
C OR CLOCK SYNCHRONIZED SERIAL INTERFACE
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
BA TRON
BT 21605AVB-YETF-LED04-I2C(HD66717)
Specification
LCD Module Type
Item No.: BT 21605AVB-03
BT 21605AVB-YETF-LED04-I2C(HD66717)
WITHOUT CONNECTOR
1. General Description
2 lines x 16 characters in a 5 x 8 dot matrix STN Positive Green-Yellow Transflective LCD Character Module.
Driving scheme: 1/34 multiplexed drive, 1/6 bias.
Optimal view direction: 6 o’clock.
Driving IC : ‘HITACHI’ HCD66717A03BP (Gold Bump) or equivalent
LCD Controller/Driver.
Serial interfacing: I2C-bus or clock-synchronized serial interface.
Built-in Booster circuit.
Temperature compensation.
Yellow-green LED04 backlight.
5/15
for
2. Mechanical Specifications
The mechanical detail is shown in Figure 1 and summarized in Table 1 below.
Table 1
Parameter Specifications Unit Outline dimensions 80.0(W) x 36.0(H) x 13.0 MAX.(D) mm Viewing area 61.0(W) x 15.8(H) mm Display format 2 lines x 16 characters (5 x 8 dots) ­Character size 2.95(W) x 5.55(H) mm Character spacing 0.60(W) x 0.40(H) mm Character pitch 3.55(W) x 5.95(H) mm Dot size 0.55(W) x 0.65(H) mm Dot spacing 0.05(W) x 0.05(H) mm Dot pitch 0.60(W) x 0.70(H) mm Weight Approx. 36.6 grams
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
BA TRON
BT 21605AVB-YETF-LED04-I2C(HD66717)
6/15
Figure 1: Outline drawing.
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
BA TRON
BT 21605AVB-YETF-LED04-I2C(HD66717)
V0 RESET CS
GND
7/15
4
VDD
SCL
SDA
LCD CONTROLLER /
DRIVER
'HITACHI'
HCD66717A03BP
(GOLD BUMP)
4
BT 21605AVB LCD DISPLAY
4
2 LINES X 16 CHARACTERS (5 X 8 DOTS)
4
4
60
60
4
20
LED+
YELLOW-GREEN LED04 BACKLIGHT
LED-
Figure 2: Block Diagram
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
BA TRON
BT 21605AVB-YETF-LED04-I2C(HD66717)
3. Absolute Maximum Ratings
3.1 Electrical Maximum Ratings (Ta = +25 °°°°C)
Table 2
Parameter Symbol Min. Max. Unit Remark Supply voltage range (Logic) VDD - GND -0.3 +7.0 V 1 Supply voltage VDD-V0 -0.3 +15.0 V 1,2 Input voltage range Vi -0.3 VDD +0.3 V 1
Note
1) The modules may be destroyed if they are used beyond the absolute maximum ratings. All voltage values are referenced to GND = 0V.
2.) VDDЊV1ЊV2ЊV3ЊV4ЊV5ЊV0 must be maintained.
8/15
ʳʳʳʳ ʳʳʳʳ
3.2 Environmental Conditions
Table 3
Operating
Item
Ambient Temperature Humidity Note 1 Note 1 no condensation Vibration (IEC 68-2-6)
cells must be mounted on a suitable connector Shock (IEC 68-2-27) Half-sine pulse shape
Note 1: 95% max. RH for Ta 40°C < 95% RH for Ta > 40°C
Temperature
Min. Max. Min. Max.
-20°C +70°C -30°C +80°C
(Topr)
Note 2 Note 2 3 directions
Note 3 Note 3 3 directions
Storage
Temperature
(Tstg)
Remark
Dry
Note 2: Frequency: 10 55 Hz Amplitude: 0.75 mm Duration: 20 cycles in each direction.
Note 3: Pulse duration: 11 ms Peak acceleration: 981 m/s2= 100g
Number of shocks: 3 shocks in 3 mutually perpendicular axes.
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
BA TRON
BT 21605AVB-YETF-LED04-I2C(HD66717)
4. Electrical Specifications
4.1 Interface signals
Table 4: Pin assignment of 9 pin connection
Pin No. Symbol Description
1 V0 Negative power supply for LCD driving voltage. 2 RESET Reset pin. Initializes the LSI when low. 3 CS Selects the HD66717 during clock-synchronized serial mode:
Low: HD66717 is selected and can be accessed. High: HD66717 is not selected and cannot be accessed.
Must be grounded (CS=”L”) for I2C bus mode. 4 GND Ground (0V) 5 VDD Power supply for logic. 6 SCL Inputs serial clock pulses during I2C bus mode and clock-synchronized
serial mode. 7 SDL Inputs serial (receive) data and outputs the acknowledge bit during I2C
bus mode;
Inputs serial (receive) data during clock-synchronized serial mode. 8 LED+ Anode of LED backlight 9 LED- Cathode of LED backlight
9/15
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
BA TRON
10/15
BT 21605AVB-YETF-LED04-I2C(HD66717)
4.2 Typical Electrical Characteristics
At Ta = +25 °°°°C, VDD = +3.0V±±±±5%, GND=0V.
Table 5(A)
Parameter Symbol Condition Min. Typ. Max. Unit Operating voltage (Logic) VDD-GND 2.85 3.0 3.15 V Operating voltage for LCD Operating supply current (Logic & LCD) Operating current for negative LCD power supply
VLCD =VDD-V5
VDD=3V, Note 1 & 2
IDD VDD=3V,
Checker board mode
I0 VDD=3V,
Checker board mode, Note 1
IL
VDD=2.85V to 3.0V -0.3 - 0.5VDD V Input signal voltage low V
6.9 7.2 7.5 V
- 0.3 0.45 mA
- 0.06 0.1 mA
VDD=3.0V to 3.15V -0.3 - 0.6 Input signal voltage high VIH 0.7VDD - VDD V Supply voltage of yellow-green LED04 backlight
VLED Supply current
=90mA.
Number of
3.8 4.1 4.5 V
LED chips=18.
At Ta = +25 °°°°C, VDD = +5.0V±±±±5%, GND=0V.
Table 5(B)
Parameter Symbol Condition Min. Typ. Max. Unit Operating voltage (Logic) VDD-GND 4.75 5.0 5.25 V Operating voltage for LCD Operating supply current (Logic & LCD) Operating current for negative LCD power supply
VLCD =VDD-V5
VDD=5V, Note 1 & 2
IDD VDD=5V,
Checker board mode
I0 VDD=5V,
Checker board mode, Note 1
6.9 7.2 7.5 V
- 0.6 0.9 mA
- 0.06 0.1 mA
Input signal voltage low VIL -0.3 - 0.6 V Input signal voltage high VIH 0.7VDD - VDD V Supply voltage of yellow-green LED04 backlight
VLED Supply current
=90mA. Number of
3.8 4.1 4.5 V
LED chips=18.
Note 1: There is tolerance in optimum LCD driving voltage during production and it will be within the specified range.
Note 2: V5 is represented by the test point V0 in the silk screen in PCB.
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
BA TRON
11/15
BT 21605AVB-YETF-LED04-I2C(HD66717)
4.3 Timing Specifications
I2C Bus Interface Operation
At Ta = -20 °C to +70 °C, VDD = +3.0V±5%, GND=0V. Refer to Fig.2, I2C Bus interface timing diagram.
Table 6
At Ta = -20 °C to +70 °C, VDD = +5.0V±5%, GND=0V. Refer to Fig.2, I2C Bus interface timing diagram.
Table 7
Figure 2 : I2C Bus Interface Timing.
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
BA TRON
12/15
BT 21605AVB-YETF-LED04-I2C(HD66717)
Clock-Synchronized Serial Interface Operation
At Ta = -20 °C to +70 °C, VDD = +3.0V±5% or VDD = +5.0V±5%, GND=0V.
Refer to Fig.3, Clock-Synchronized Serial Interface Timing.
Table 8
Figure 3: Clock-Synchronized Serial Interface Timing
Reset Timing
At Ta = -20 °C to +70 °C, VDD=+3.0V±5% or VDD=+5.0V±5%, GND=0V. Refer to Fig.4, Reset timing diagram.
Table 9
Parameters Symbol Min. Typ. Max. Unit
Reset low-level width t
10 - - ms
RES
RESET
Figure 4 : Reset Timing Diagram
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
BA TRON
13/15
BT 21605AVB-YETF-LED04-I2C(HD66717)
4.4 Relation between Character Codes and Character Patterns (ROM code: A03)
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
BA TRON
14/15
BT 21605AVB-YETF-LED04-I2C(HD66717)
4.5 Slave Address Selectable. ( Jumper Set )
ID 5 ID4 ID3 ID2 ID1 ID0 1 JP1 JP3 JP5 JP7 JP9 JP11 0 JP2 JP4 JP6 JP8 JP10 JP12 Default. 011100 Short JP 2, 3, 5, 7, 10, 12
4.6 I2C or Clock Synchronized Serial Interface Selectable
Short Open I2C ( Default ) JP15, 17, 21 Jp22 Clock Synchronized Serial JP14, 17, 22 JP21
4.7 External or Internal VLCD Selectable
Open Short External VLCD ( V0 ) JP 18, 19, 20 / Internal VLCD ( 5V Input ) JP 13,18, 19 JP 20 Internal VLCD ( 3V Input ) JP 20 JP 13,18, 19
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
BA TRON
15/15
BT 21605AVB-YETF-LED04-I2C(HD66717)
4.8 Timing Diagram of VDDAgainst V5.
Power on sequence shall meet the requirement of Figure 5, the timing diagram of V against V5.
95%
LOGIC SUPPLY
VOLTAGE
0V
50ms(typical)
DD
VDD
OV
LCD SUPPLY
VOLTAGE
Note : V5 is represented by the test point V0 in the silk screen in PCB.
V5
Figure 5: Timing Diagram of V
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
Against V5.
DD
www.data-modul.de
Loading...