OPERATING INSTRUCTIONS!
!
The Bartol “Mag-Probe" is an Instrument for
sensing magnetic fields.!
!
CAUTION: Damage may result if the "Mag-
Probe" Is dropped.!
General applications!
All voltages (AC & DC)!
Solenoids, Solenoid valves, Relays, Reed
relays, Coils, Rotary solenoids, Stepper
switches, Detecting residual magnetism,
Coils, Transient current pulses, Identifying
North & South poles, etc.!
The white magnetic shield on the “MagProbe’s" tip reduces the chance of
magnetic fields turning it on during
storage and must be removed before
using. Replace the magnetic shield after
using.!
!
DO NOT STORE THE “MAG-PROBE" NEAR A
PERMANENT MAGNET OR MAGNETIC FIELD.!
!
A “Mag-Probe" will not detect devices
enclosed in a magnetic shield. (most
devices aren’t shielded.)!
!
You may self test the “Mag-Probe" with the
High/Low sensitivity ring supplied with each
unit.!
!
TESTING AC & DC DEVICES WITHOUT!
USING THE HIGH/LOW SENSITIVITY RING!
1. Hold the “Mag-Probe" as shown in
figure 2."
!
2. Place the tip close to or on the shaft that
projects through the device’s coil."
!
3. Observe the LED in the “Mag-Probe’s"
handle."
!
4. If the LED is on,the solenoid or relay is
energized."
!
5. If the LED is off, the solenoid or relay is
de-energized."
!
6. If the LED turns on and off, and flow
through the solenoid valve under test is
not interrupted, or power through a
relay’s contacts don’t turn on and off, a
mechanical failure has occurred. "
!
7. If the LED remains off during machine
operation, two possible problems exist:!
A. No power to the solenoid or relay.!
B. An open coil"
To locate the problem, first test the
power source, then the solenoid or
relay coil."
!
8. If transit pulses are suspected, hold the
Probe tip close to or on the solenoid or
relay and observe the LED during a
machine cycle. If transit pulses are
present during the time the solenoid or
relay should be off, the LED will flash on
and off.!
"
With a little practice, you’ll know when to
use the high/low sensitivity ring in order to
test sub-miniature and smaller devices.!
!
If you need the added sensitivity, install the
high/low sensitivity ring according to the
following instructions.!
www.GlobalTestSupply.com