INTRODUCTION
Thank You for choosing us. The perfect tub
for your remodeling and building needs.
Before Using
Before using your Hydromassage Bath Tub, please read the IMPORTANT OPERATING, SAFETY, MAINTENANCE, and INSTALLATION INSTRUCTIONS in this manual. To ensure maximum performance and warranty protection, be sure your bath unit is installed according to the installation instructions in this manual.
ALSO NOTE
INSTALLATION OF HYDROMASSAGES MUST CONFORM TO STATE AND LOCAL CODES: BUILDING, PLUMBING, AND ELECTRICAL.
Electrical component manufacturers instructions for bonding and grounding are especially important and must be in compliance.
The variety of installations possible with this Hydromassage tub may require framing procedures other than those described in this manual.
Information contained in this manual is based on the latest product features available at the time of publication. We reserve the right to make changes in product features, packaging or availability without notice. Our hydromassage tubs are UL listed.
TABLE OF CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Framing Tub/Shower Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3, 4
Framing Sunken Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Apron Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Electrical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Pictorial Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Care and Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
1
IMPORTANT SAFETY INSTRUCTIONS
INSTRUCTIONS PERTAINING TO A RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS.
IMPORTANT SAFETY INSTRUCTIONS WARNING–When using this unit, basic precautions should always be followed,
including the following:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. DANGER: To reduce the risk of injury, do not permit children to use this unit unless they are closely supervised at all times.
3. The water temperature in the hydromassage bath should not exceed 104 degrees F (40 deg C). Hot hydromassage baths can put certain stresses on the body, as does any hot bath or shower. Therefore, hydromassage bathing may not be suitable for all persons. If you have a heart condition, high blood pressure, diabetes, circulatory problems, or if you are under the care of a physician, consult your physician before using a hydromassage bath. Failure to do so may result in bodily injury or serious health hazards.
4. If you are pregnant you should consult your physician before using the hydromassage bath. The hydromassage action may prove hazardous.
5. Do not consume alcoholic beverages or take medications or drugs prior to or when using the hydromassage bath. Alcohol and drugs affect mental judgement and inhibit bodily functions such as heartbeat and respiration, resulting in potentially dangerous effects.
6. Acrylic and gel surfaces can be slippery when wet. Please exercise caution when entering, leaving, or moving about in the hydromassage bath.
7. Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer.
8. Never drop or insert any object into any opening.
9. Do not operate this unit without the guard over the suction fitting.
10. The unit must be connected only to a supply circuit that is protected by a ground-fault circuit-interrupter (GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI push the test button. The GFCI should interrupt power. Push the test button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the bathtub without the test button being pushed, a ground current is flowing, indicating the possibility on an electric shock. Do not use this hydromassage bathtub. Disconnect the hydromassage bathtub and have the problem corrected by a qualified service representative before using.
11. (For permanently connected units) a green-colored terminal (or a wire connector marked “G,” “GR,” “Ground,” or “Grounding.”) is provided within the terminal compartment. To reduce the risk of electric shock the grounding terminal of your electric service or supply panel should be wired with a conductor equivalent in size to the circuit conductors supplying this equipment.
12. SAVE THESE INSTRUCTIONS
2
INSTALLATION INSTRUCTIONS
ATTENTION INSTALLER: PLEASE READ THE FOLLOWING IMPORTANT CONSIDERATIONS! READ ALL INSTRUCTIONS CAREFULLY AND FOLLOW ALL LOCAL PLUMBING AND ELECTRICAL CODES.
1. Before installation, make sure proper access is made to the final connections.
2. Installation must comply with local and national electrical codes.
Electrical connections should be made by a qualified electrician.
3. A properly connected ground fault interrupter must be used.
4. The building materials and wiring should be routed away from the pump body or
other heat-producing components of the units.
DO NOT USE THE PIPING OR PUMP FOR STRUCTURAL SUPPORT OR POSITIONING OF HYDROMASSAGES. DO NOT SUPPORT THE WEIGHT OF THE BATH TUB BY THE RIM. MAKE SURE BOTH CONNECTIONS TO THE PUMP ARE SECURELY TIGHTENED. CONSTRUCTION DAMAGE IS NOT COVERED UNDER WARRANTY!
When cleaning up after installation, DO NOT USE ABRASIVE CLEANERS as they may scratch and dull the unit surface. Use warm water and one of the liquid detergents to clean the surface. Stubborn stains, paint, or tar can be removed with turpentine or paint thinner, DO NOT ALLOW CLEANERS CONTAINING PETROLEUM DISTILLATES TO REMAIN IN CONTACT WITH TUB SURFACES FOR LONG PERIODS OF TIME. Plaster can be removed by scraping with a wood edge. Do not use metal scrapers, wire brushes, or other metal tools.
FRAMING TUB/SHOWER UNITS
1. The tub should be on the job site during the early stage of framing. Studs may be
temporarily omitted to allow unit to be moved into place (figure1).
2. Rough-in drains should be located according to the line drawings for the particular
unit. When measuring the tub to obtain these measurements, be sure to use the top of the unit for the overall depth and width of the unit. Please note that most units have slanted backs and sides, but the front of the unit should always be installed vertically plumb.
3. Prior to installation, check to be sure the framed-in area is proper size, square and
plumb.
4. If a one hour fire wall is required, contact the factory for recommended method of
installation. A one hour fire wall can normally be obtained by placing 5/8” dry wall on the studs prior to the installation of the unit.