BAS-IP AV-07T Instruction Manual

The individual outdoor panel
BAS-IP AV-07T
The instruction manual
Page 2
For the correct installation, follow the instructions. If you have any difficulty with installation and operation, please contact your dealer for advice. The technical parameters and specifications mentioned here may vary slightly from those stated in the instructions of the devices. This is our company conducts constant upgrading and improvement of the functionality to improve the characteristics of current devices.
Page 3
CONTENT
Appearance Main functions Technical parameters Equipment Settings through the WEB interface Connection scheme Mounting scheme Attachment 1 Notes
Page 4
APPEARANCE
Model: AV-07T
Page 5
MAIN FUNCTIONS
BAS-IP AV-07T
Interface
WEB-interface
Lock opening
By card, with the monitor
Access control
Combined contactless card reader: EM-Marin and MIFARE
Integration with ACS
Wiegand-26, Wiegand-34 Input / Output
Quick dial buttons
1 piezoelectric ring button
Number of ringtones
1 polyphonic ringtone
Authentication
A separate password for the settings, WEB-interface
Talking mode
Double-sided
Talking time
Up to 30 minutes
Additional functions
SIP P2P; TR-069, 2 SIP accounts; 2 relays for connection of 2 locks; 2 contacts for connection of 2 exit buttons; Separate locks control; 3 controlled inputs for alarm; Motion Sensor; Gyroscope
Page 6
TECHNICAL PARAMETERS
BAS-IP AV-07T
Panel type
Individual
Screen
No
Matrix size
1/4’’
Angle
122° horizontal x 56° vertical
Matrix resolution
2 MP
Output video
720p (1280x720) H.263, H264, MJPEG
Night backlight
4 IR LEDs
Light sensitivity
0.01 lux
Protection class
IP65
Operating temperature
-40 - +65 °C
Power consumption
6.5 W, in standby – 4 W
Power
+12 W, PoE
Body
Metal
Colors
Silver gray, black
Dimensions for installation
165x108x65 mm
Dimensions of panel
168x115x40mm
Installation
Flush mounting, wall mounting with BR-AV7
Page 7
EQUIPMENT
Outdoor panel Sealing rubber Protective shroud Sealing ring
М2.5х6.5 – М2.5х6.5 screws for Allen wrench М3х5 – М3х5 screws for Phillips head screwdriver
Allen wrench
Strap for installation work
Flush-mounting bracket
Page 8
EQUIPMENT
Built-in box for flush mounting Screws for Phillips head screwdriver: M4x10 and ST4x20 Plastic dowels Wall-mounting bracket (not included)
Page 9
SETTINGS THROUGH THE WEB INTERFACE
Searching the IP address of the outdoor panel After the outdoor panel and your PC have connected to the same local area network, run the
“AV07T Device manager” to determine an IP address of the outdoor panel:
Press the “Scan” button and program window will display IP addresses of all AV-07T outdoor
panels, which are connected to the local network. It is possible to change the basic network settings, update a firmware of the outdoor panel and programmatically restart it.
Page 10
SETTINGS THROUGH THE WEB INTERFACE
To configure the outdoor panel remotely via the WEB interface and to set the virtual numbers, you need to connect to it via Internet-browser on your PC. The outdoor panel should be connected to the same network segment, as the PC, from which it is planned to customize the outdoor panel. Enter the IP address of the outdoor panel in an address line of a browser, then the window for entering the user name and password will appear. Username to access the settings is admin. Password required to enter, matches the password for accessing the settings of the outdoor panel and is an installer password (the default password is admin).
1. Status
Select the "Status" menu option to access the current status interface:
2. Intercom
2.1 Basic
Select “Basic to access the call configuration:
Page 11
SETTINGS THROUGH THE WEB INTERFACE
Select account: Account which is used for calls. Dialing if not answered: Call forwarding function if no answer is received from dialed subscriber. Ring button: A field for entering a subscriber number you are dialing by pressing the ring button. To call the device using the internal protocol, you need to enter the 7-digit number, for example, "# 1010027", where "1" is the number of a building, "01" – the number of the entrance, "00" - the floor number and "27" - the apartment number. Dialing if not answered Call 1, Call 2: Fields for entering subscriber’s numbers, which incoming call will be forwarded to, if it is no answer from main number.
Page 12
SETTINGS THROUGH THE WEB INTERFACE
FTP: Sending the visitor’s photo to FTP-server. E-mail: Sending of the visitor's photo to the specified E-mail. HTTP URL: GET request to the specified address. HTTP URL: The URL to which GET request will be sent if such option selected. Web call: Calling the number specified in the field number from the web interface of the panel. Maximum call time: The maximum duration of a call (2 - 30 minutes). Maximum dial in time: The maximum dialing time for incoming calls (from 30 to 120 seconds). Maximum dial out time: Maximum dialing time for outgoing calls (from 30 to 120 seconds). Push to hang up: The call cancellation function by repeatedly pressing the push button.
2.2 Advanced
Select "Advanced" to access advanced settings of call configuration.
Page 13
SETTINGS THROUGH THE WEB INTERFACE
AEC Level: AEC Level. Default value is 700. Photo resistor Settings: Range of photo resistance sensitivity level (0-100). The default values are 5 - 37. Tamper Alarm: Alarm on / off function on the tamper. Accelerometer Trigger Threshold: Accelerometer Trigger Level (0 – 127). The default value is 32. Location Setting: Number of building, unit, floor, room, serial number, sync number. IP server: The IP address of the server with Management Software. Wiegand Type: The type of used Wiegand interface. It is possible to choose between Wiegand - 26 and Wiegand - 34. Blinking Time: The blinking frequency of the ring button LEDs during the lock opening is from 500 ms up to 5000 ms.
2.3 Relay
Select “Relay” to access the configuration of the relay outputs:
Page 14
SETTINGS THROUGH THE WEB INTERFACE
ID Relay: Relay identifier. Relay type: Relay operating mode. May be set in the NO or NС position. Opening time: Relay activation time (0 - 10 sec.). DTMF option: The number of DTMF code symbols transmitted to activate the relay. DTMF: The code transmitted to activate the relay (this option is active if an item 1 Digit DTMF is selected in the DTMF-option). Multiple DTMF: A field for entering a user DTMF code, transmitted to activate the relay (this option is active if an item 2 – 4 Digit DTMF is selected in the DTMF-option). Relay Status: The current status of the relay (closed or open).
2.3.1 Web relay
Type: A feature that allows enabling / disabling the ability of panel to work with 2N WebRelay. IP address: IP address of the 2N WebRelay. Username: Login of the 2N WebRelayweb interface. Password: Password of the2N WebRelayweb interface.
2.3.2 Open relay via HHTP
Type: Enabling / Disabling the signal transmission to open the door via HHTP-link. User name: The user’s login. Password: The password for access. The default values are empty. URL format: http://192.168.1.229/fcgi/do?action=OpenDoor&UserName=&Password=& DoorNum = 1, where 192.168.1.229 is an IP address of the outdoor panel, UserName is the name of the user, Password is the password of the user, DoorNum is the relay number.
2.4 Inputs
Select "Inputs" to access the configuration of the controlled inputs:
Page 15
SETTINGS THROUGH THE WEB INTERFACE
2.4.1 Input
Input Status: Enabling / disabling the controlled input when closing contacts. Action: Additional action when closing the input contacts. FTP: Sending the visitor's photo to the FTP server.
Page 16
SETTINGS THROUGH THE WEB INTERFACE
E-mail: Sending the visitor's photo to the specified E-mail. SIP call: SIP call to a specified number on the "Trigger" tab. HTTP URL: GET-request to the specified address. HTTP URL: The URL which GET request will be sent to if the appropriate option selected. Open relay: The function of opening the specified relay when the input is triggered. Input Status: Displays the current input status.
2.5 Web view
Select "Web view" to access streaming video from the outdoor panel camera:
2.6 RTSP Select "RTSP" to access the streaming video display settings from the camera of the outdoor panel via the RTSP protocol:
Page 17
SETTINGS THROUGH THE WEB INTERFACE
2.6.1 RTSP Basic
RTSP Server: Enabling / Disabling the RTSP server.
2.6.2 RTSP Stream
RTSP audio: The function of sound transmitting from the outdoor panel’s microphone via the RTSP protocol. RTSP video: The function of video transmitting from the outdoor panel’s camera via the RTSP protocol. RTSP video codec: Used codec for video transmission via RTSP (H.264, MPEG4, MJPEG). An example of a RTSP line for recording video from the outdoor panel’s camera: rtsp: //192.168.1.186/live/ch00_0.
2.6.3 H.264 Video Parameters Video resolution: Resolution of the transmitted video stream (QCIF, QVGA, CIF, VGA, 4CIF, 720P).
Page 18
SETTINGS THROUGH THE WEB INTERFACE
Video frame rate: Number of the transmitted frames per second (10fps, 15 fps, 20fps). Video bit rate: The compression ratio of the video stream (64 kbps, 128 kbps, 256 kbps, 512 kbps, 1024 kbps, and 2048 kbps).
2.6.4 MPEG4 Parameters
Video resolution: Resolution of the transmitted video stream (QCIF, QVGA, CIF, VGA, 4CIF, 720P). Video frame rate: Number of the transmitted frames per second (10fps, 15 fps, 20fps). Video bit rate: The compression ratio of the video stream (64 kbps, 128 kbps, 256 kbps, 512 kbps, 1024 kbps, and 2048 kbps).
2.6.5 MJPEG
Video resolution: Resolution of the transmitted video stream (QCIF, QVGA, CIF, VGA, 4CIF, 720P). Video frame rate: Number of the transmitted frames per second (10 fps, 15 fps, 20 fps). Quality: The quality of the transmitted video stream (50, 60, 70, 80, 90).
2.7 ONVIF Parameters
Select "ONVIF Settings" to access the display settings of the streaming video from the outdoor panel’s camera via ONVIF protocol: