Safety instructions
Before installing the unit, read this manual thoroughly and retain it for future reference. The device should be installed in compliance with oicial regulations valid in country of use. The device may only be installed and connected by qualified electricians. Ensure that electricity is switched o when installing or unmounting the device. Do not open, dismantle, alter or modify the device.
Components
Wall base
0130-01
A
B
B
D
C
E
B
A Opening to fix the outlet to the wall box B Clips to mount the cover plate C Charging connector for Eve Plus sleeve D This sign up E Alligning magnets F 24V DC power connector
B
A
Eve Plus Cover
(not included)
F
Model No. 0131-CC
Wall boxes
The wall base should be installed in European wall boxes with screws. The distance between the screws needs to be 60mm, and a minimal depth of 45 mm is required. Square wall boxes size 60 x 60 mm are compatible with the sockets. Round wall boxes should have an inner diameter of 64mm or more.
The following round wall boxes are compatible with the Basalte sockets :
Helia round with cut hole 68 mm (type 247, 261).
Kaiser round with cut hole 68 mm (type 9063-xx, 9064-xx, 9062-xx).
Legrand batibox round (ref 080051, 080061, 080052, 080053).
ABB round Hafobox MD4050 and hollow wall boxes HW-50, HW50-G, HW52-F (Except HW52-F IGD and HW52-F BW).
When using other round boxes, please verify the compatibility upfront. Do not use following wall boxes:
Helia O-range
Kaiser (1055-xx – 1056-xx)
ABB 3040
ABB HW52-F IGD and HW52-F BW
EVE Plus wall base 24V
© 2018
basalte v1.0
Installation Manual
Installation instructions
1. Install square wall box (60mm) or compatible round wall box. Wall box should have screws with a vertical distance of 60mm and minimal depth of 45mm.
2. Connect the 24V DC power lines using the terminals.
3. Fix the wall base to the wall box with 2 screws using the holes on vertical axis.
4. Mount the cover using the clips. ( see drawing a & b )
PUSH FORWARD & CLICK ON THE CLIPS ABOVE
a
CLICK ON THE CLIPS BELOW
b
Cabling
The cable between the DC power supply and wall base must have a cable section of at least 0.8mm² and maximum 1.5mm². The applicable maximum cable lengths are specified both 12V and 24V. To limit power loss in the cable, we recommend using a star wiring from the power supply to each single wall base. We advise to automatically put the iPad in standby mode when not in use to reduce power consumption.
Maximum cable length between DC power supply and wall base Cable type 12V DC 24V DC
0.8mm² (AWG 19) 50m (164) 300m (984)
1.0mm² (AWG 18) 60m (197) 400m (1312)
1.5mm² (AWG 17) 90m (295) 500m (1640)
How to remove the Socket front cover ( see drawing c & d )
c
PUSH UP
Technical data
Power supply: 10 - 30 V DC Consumption: Input power 12W Operating temperature: 0°C - +35°C