Bartscher 105.840, A105.942, A105.943, A105.946, A105.948 Service Manual

...
Bartscher GmbH
Franz-Kleine-Str. 28 , 33154 Salzkotten
www.Bartscher.de
Operation instructions
for
Induction Units
Ver.1.1
105.840, A105.942, A105.943, A105.946, A105.948
A105.949, A105.952, A105.953, A105.954, A105.956, A105.957
A105.935, A105.936, A105.937, A105.938, A105.939
A105.950, A105.958, A105.968, 282.410, 282.420
Page 1 of 21
Contents list Page
1 General information 3
1.1 Area of application 2 Products description 3
2.1 Products
3
2.2 Technical Data
2.2.2. Technical data 4
2.2.3. Function conditions 4
2.2.1. Operation and Control 4
3 Installation
3.1 Electrical data of the Units
3.1.2. Unit Performance (3,5 kW) 5
3.1.3. Unit Performance (5 kW) 5
3.1.4. Unit Performance (7 kW, 8 kW) 5
3.1.1. Unit Performance (2,5 kW, 3 kW) 5
3.2 Installation requirements 6
3.3 Installation instructions
3.4 Additional Installation instructions for the built-in Model 4 Taking the Unit into Service 7
4.1 Unit Assembly 5 Function test 9 6 Operation 10
6.1 Cooking
10
7 Safety instructions 11
7.1 Description of warning symbols and indicators
7.2 Dangers resulting from not observing the safety instructions
7.3 safe Application
7.4 Operator Safety Instructions
7.5 Improper operation
7.6 Modification / use of spare parts
7.7 Pan detection
13
7.8 Heating zone monitoring
7.9 Noises 8 When the unit is not in use 13
13
9 Troubleshooting 14-16
9.1. Overview error messages on display 10 Cleaning 17 11 Maintenance 18 12 Disposal 18 13 Sparepartlist 19-21
3
4
5
6
6-7
7-8
11
11
12
12
13
13
13
16
Ver.1.1
Page 2 of 21
1. General information
These operating instructions contain basic information on what needs to be considered during installation, operation, and maintenance of the equipment. They must be read entirely by the fitter and operators before the equipment is installed and taken into operation. They must always be kept close to the cooking site for reference.
1.1 Area of application
“Berner” cooking units have been designed for the preparation of meals. They can be used for cooking, keeping food warm, as well as for flambé singing, grilling, etc. Note: Only use pans suitable for induction cooking with these units. You should not use no-name products. The pan bottom must be magnetic. If in doubt, check with the help of a magnet.
2. Products description
2.1 Products
BM-Modelle
A105.942, A105.943, A105.954, 282.410, 282.420
BI-Modelle
A105.946, A105.948, A105.949, A105.952, A105.953, A105.956, A105.957
BW-Modelle
105.840, A105.935, A105.936, A105.937, A105.938
- Compact module design
Ver.1.1
- Easy installation
- service-friendly
- easy operation via power control knob
- compact high-performance electronics for easy and safe operation
- max. operation safety due to various protecting and control functions
- compact outside dimensions
- low weight
Page 3 of 21
2.2 Technical Data
2.2.1 Operation and Control
Operation indicator lamp Operation, Pan Detection“ 2V DC/ approx. 10mA (LED red) Output regulator potentiometer 0Ohm – 10kOhm
Digital display „Performance und Fault display“ 2,8V DC/ca. 60mA (red) Dimensions W x D x H Ceramic glass surface
105.840 330 x 380 x 175 mm Wok glass bowl A105.942,.943,.954 340 x 420 x 100 mm 290 x 290 mm A105.946,.948,.949 400 x 455 x 120 mm 350 x 350 mm A105.956,.957 400 x 655 x 120 mm 350 x 560 mm A105.952,.953 700 x 455 x 120 mm 650 x 350 mm A105.935,.936,.937 400 x 455 x 180 mm Wok glass bowl A105.938 500 x 555 x 235 mm Wok glass bowl A105.950 400 x 400 mm 350 x 350 mm A105.958 400 x 700 mm 350 x 650 mm A105.968 700 x 700 mm 650 x 650 mm
282.410 400 x 700 x 860-900 mm 350 x 605 mm
282.420 800 x 700 x 860-900 mm 650 x 605 mm
2.2.2 Technical Data
Unit Voltage Performance Weight
105.840 1 x 230 V 3.0 kW 8,5 kg A105.942,.943,.954 1 x 230 V 2.5, 3.0, 3,5 kW 9 kg A105.949 3 x 400 V 5 kW 13 kg A105.946,A105.948 1 x 230 V 3.0, 3.5 kW 11-13 kg A105.937 3 x 400 V 5kW 14 kg A105.935,A105.936 1 x 230 V 3.0, 3.5 kW 11-13 kg A105.938 3 x 400 V 8 kW 19 kg A105.950 3 x 400 V 5 kW 12 kg A105.958 3 x 400 V 7, 10 kW 21 kg A105.968 3 x 400 V 20 kW 40 kg
282.410 3 x 400 V 10 kW 50 kg
282.420 3 x 400 V 20 kW 80 kg
2.2.3 Function conditions
- max. tolerance of main voltage +5%/-10%
- frequency 50 / 60 Hz
- IP Code IP 43
- min. Pan-diameter 12cm
Ver.1.1
Page 4 of 21
3 Installation
3.1 Electrical data of the Units
3.1.1. Unit Performance (2,5 kW, 3 kW) Inductions unit 1-phase (Voltage 230 Volt +5% / -10%) Connection
Colour Frequency Fuse
Phase Black 50 Hz / 60 Hz Empty N Blue
Ground Yellow/Green
Working
frequency
22-35 kHz
Control fuse
1 X 400mA T
(time lag)
3.1.2. Unit Performance (3,5 kW) Inductions unit 1-phase (Voltage 230 Volt +5% / -10%) Connection
Colour Frequency Fuse
Phase Black, Brown or 1 50 Hz / 60 Hz 2 X 20A FF
N Blue or 2
Ground Yellow/Green
Working
frequency
22-35 kHz
(super-quick) Control fuse
2 X 160mA T
(time lag)
3.1.3. Unit Performance (5 kW) Inductions unit 3-phases (Voltage 400 Volt +5% / -10%) Connection
Phase Black, Brown or 1,
N Blue or 4
Ground Yellow/Green
Colour Frequency Fuse
50 Hz / 60 Hz 3 X 12,5A FF
2, 3
Working
frequency
22-35 kHz
(super-quick)
Control fuse
2 X 100mA T
(time lag)
3.1.4. Unit Performance (7 kW, 8 kW) Inductions unit 3-phases (Voltage 400Volt +5% / -10%) Connection Colour Frequency Fuse
Phase Black, Brown or 1,
2, 3
N Blue or 4
Ground Yellow/Green Installations-environment
- max. ambient temperature
50 Hz / 60 Hz 3 X 16A FF
Working
frequency
22-35 kHz
(quick)
Control fuse
2 X 100mA T
(time lag)
Ver.1.1
Storage >-20°C till +70°C in Function >+5°C till +35°C
- max. relative Atmospheric humidity
Storage > 10% till 90% in Function > 30% till 90%
Page 5 of 21
3.2 Installation requirements
The Induction-Unit has to be placed on a flat horizontal area. Don’t cover the air supply for the air circulation. The place must be allowing a weight up to min. 40 kg. To disconnect the Power, the user needs easy access to the power-connection.
3.3 Installation instructions
The following Points must always be observed during installation: Make sure that the main voltage corresponds to the voltage indicated on the
nameplate of the equipment.
- All electric installations must fulfill the local building code regulations. All regulations issued by the national electricity authorities must be observed.
- The induction unit is equipped with a main cable and a plug which can be plugged into a socket.
- When using fault-current circuit breakers, they must be designed for a minimum fault current of 30 mA.
- Avoid blocking the air inlet and outlet zones with objects (textiles, walls, etc.).
- Prevent hot ambient air from being drawn into the induction unit (for example, when several units stand next to each other, behind each other, or when the unit is placed close to tilt fryers or ovens). In such cases, use a separate air duct.
- The induction unit must not be placed close to or on top of hot surfaces.
- The unit is equipped with a suction filter. Despite the presence of this filter, you must still make sure that no greasy ambient air resulting from other activities can be drawn into the induction unit (e.g. close to deep fryers, griddles, or tilt fryers).
- The temperature of the drawn-in air must be below +35°C.
- The personnel operating the equipment must make sure that all installation, maintenance, and inspection work is done by specially trained and certified personnel only.
3.4 Additional Installation instructions for the built-in Model
- The inlet air must be guided through an air duct and passed on directly to the fans via the filters delivered with the equipment. The size of the air inlet should be at least 200 cm².
- The inlet air upstream of the cooler fan must never exceed a maximum temperature +35°C.
- Do not allow a “thermal closed circuit” to occur. Under no circumstances the outlet air must be drawn in again, because this overheats the unit.
- After installation, the equipment’s functions must be tested. To do so, determine the maximum cooling plate temperature. The temperature must be measured at the cooling plate base, below the induction coil, which is located at the centre of the equipment, close to the transistor module (large black block). In continuous
Ver.1.1
Page 6 of 21
operation of at least 2 hours and at an ambient temperature of 20°C, the temperature must not exceed 50°C.
- All BI-Modelle (A105.950,A105.958,A105.968) have to be fastened.
- When using potentiometer lines, longer than 60 cm, the lines must be shielded and connected to terminal S of the induction module.
- The main cable must always be shielded, clean contacts provided at both sides.
- Select and set up the main isolator so, that the equipment is switched on and off no more than 5 times a day.
The Induction-Unit has to be equipped with right Cable and Plug for the Regulations of the Country WHERE the Unit will be used.
Make sure that the plug is wired correctly:
For the electric Connection for the Unit take attention. The Law Regulations of the Country have to be adhered!
Warning
Wrong Voltage can damage the
Induction Unit
The electrical Connection must only be
implemented by specially trained staff
Warning
4 Taking the Unit into Service
4.1 Unit Assembly
<Warning Electrical connections must be installed by trained staff personnel only.>
Our induction units are equipped with one a main cable which must be connected with a wall socket. If no plug has been installed at the cable, connect the plug as described in chapter 3. Electric installations must be carried out by registered installation companies only, observing the specific national and local regulations. These companies are responsible for correctly interpreting all regulations and performing the installation in compliance with the safety instructions. Indications on warning signs and nameplates must be strictly observed.
Make sure that the main voltage corresponds to the voltage indicated for the unit (given on the nameplate).
The Induction-unit must always be installed on a clean, plain, and horizontal surface only (table, cupboard, etc.). The equipment stands on non-slip rubber feet which are permanently mounted. It must be placed so that it cannot fall down or be moved due to a slanted position. Make sure that the requirements given in chapter 3.1 “Installation requirements” are fully met.
Ver.1.1
Page 7 of 21
Loading...