Bartscher 700FX-G40, 700FX-G20, 700FX-G60 Operating instructions

700FX-G20 / 700FX-G40 / 700FX-G60
2831021 - 2831041 - 2832361
Phone: +49 5258 971-0 Fax: +49 5258 971-120 Service hotline: +49 5258 971-197 www.bartscher.com
CE-0085DL0222
Version: 1.0 Date of preparation: 2024-02-14
EN 2
2831021 1 / 38
Original instruction manual
1 Safety ............................................................................................................ 2
1.1 Explanation of Signal Words .................................................................... 2
1.2 Safety instructions.................................................................................... 3
1.3 Residual Risks ......................................................................................... 7
1.4 Personal Protective Equipment ................................................................ 9
1.5 Intended Use ......................................................................................... 10
1.6 Unintended Use ..................................................................................... 10
2 General information ..................................................................................... 11
2.1 Liability and Warranty ............................................................................ 11
2.2 Copyright Protection .............................................................................. 11
2.3 Declaration of Conformity ...................................................................... 11
3 Transport, Packaging and Storage .............................................................. 12
3.1 Delivery Check ....................................................................................... 12
3.2 Packaging .............................................................................................. 12
3.3 Storage .................................................................................................. 12
4 Technical Data ............................................................................................. 13
4.1 Technical Specifications ........................................................................ 13
4.2 Functions of the Appliance ..................................................................... 15
4.3 List of Components of the Appliance ..................................................... 22
5 Installation Instructions ................................................................................ 24
5.1 Installation .............................................................................................. 24
6 Operating Instruction ................................................................................... 30
6.1 Operation ............................................................................................... 31
7 Cleaning and Maintenance .......................................................................... 35
7.1 Safety Instructions for Cleaning ............................................................. 35
7.2 Cleaning ................................................................................................. 35
7.3 Maintenance .......................................................................................... 36
8 Possible Malfunctions .................................................................................. 37
9 Disposal ....................................................................................................... 38
Safety
2 / 38 2831021
EN
Diese Bedienungsanleitung beschreibt di e Installation, Bedienung und Wartung des Geräts und gilt als wichtige Informationsqu elle und Nachschlagewerk. Die Ke nntnis aller enthaltenen Sicherheitshinw eise und Handlungsanweisungen schafft die Voraussetzung für das sichere und sachgerechte Arbeiten mit dem Gerä t. Darüber hinaus müssen die für de n Einsatzbereich des Geräts geltenden örtli chen Unfallverhütungsvorschriften u nd allgemeinen Sicherheitsbestimmungen eingehalten werden. Diese Bedienungs anleitung ist Bestandteil des Prod ukts und muss in unmittelbarer Nähe d es Geräts für das In¬stallations-, Bedie nungs-, Wartungs- und Reinigungspers onal jederzeit zugänglich auf¬bewahrt werde n. Wenn das Gerät an eine dritte Pers on weitergegeben wird, muss die Bedienungsa nleitung mit ausgehändigt werden.
Read this instruction manual before using and keep it available at all times!
This instruction manual contains information about installation, operation and maintenance of the appliance and constitutes an important source of information and reference guide. The knowledge of all operational and safety instructions included in this manual is a prerequisite for safe and proper handling of the appliance. Additionally, accident prevention, occupational health and safety, and legal regulations in force in the area the appliance is used apply.
Before you start using the appliance, especially before turning it on, read this instruction manual in order to avoid personal injuries and property damages. Improper use may cause damage.
This instruction manual forms and integral part of the product and must be stored in an immediate vicinity of the appliance and be available at all times. The instruction manual should be transferred together with the appliance.

1 Safety

This appliance has been manufactured in accordance with technical standards currently in force. However, the appliance may be a source of hazards if used improperly or contrary to its intended purpose. All persons using the appliance must consider information included in this instruction manual and observe safety instructions.

1.1 Explanation of Signal Words

Important safety instructions and warning information are indicated in this instruction manual with appropriate signal words. You must strictly follow the instructions, to prevent accidents, personal injuries and property damages.
DANGER!
The signal word DANGER warns against hazards that lead to severe injuries or death if the hazards are not avoided.
Safety
2831021 3 / 38
EN
WARNING!
The signal word WARNING warns against hazards that may lead to moderate or severe injuries or death if the hazards are not avoided.
CAUTION!
The signal word CAUTION warns against hazards that may lead to light or moderate injuries if the hazards are not avoided.
, die
IMPORTANT!
The signal word IMPORTANT indicates possible property damages, which may occur if safety instructions are not observed.
NOTE!
The symbol NOTE indicates subsequent information and guidelines for the user on usage of the appliance.

1.2 Safety instructions

Electrical Current
Too high a mains voltage or incorrect installation may cause electric shock.
The appliance may be connected only if data on the rating plate correspond with
the mains voltage.
To avoid short-circuit, the appliance should be kept dry.
If there are malfunctions during operation, disconnect the appliance from the
power supply.
• Do not touch the appliance’s plug with wet hands.
Never take hold of the appliance if it has fallen into water. Immediately
disconnect the appliance from the power supply.
Any repairs or housing opening may be carried out by professionals and
relevant workshops only.
Do not transport the appliance, holding it by the power cord.
Do not allow the power cord to come into contact with heat sources or sharp
edges.
Do not bend, pinch nor knot the power cord.
Safety
4 / 38 2831021
EN
Always completely unwind the power cord.
Never place the appliance or other objects on the power cord.
Always take hold of the plug to disconnect the appliance from the power supply.
Check the power cord regularly for damage. Do not use the appliance if the
power cord is damaged. If this cable is damaged, it must be replaced by customer service or a qualified electrician in order to avoid dangers.
Safety of Gas Supplied Appliances
Do not use a gas supplied appliance in the event of a malfunction or damage or
in the case of a suspected malfunction or damage. In such a case set the knob(s) to 'O' and close the main gas valve. Contact the service company immediately.
Regularly conduct tightness checks using suds (a spray for detecting leakages).
Do not use open flame for checking tightness of gas installation!
WARNING! Suffocation and explosion hazard due to leaking gas!
When you sense gas odour, observe the following rules:
immediately close the knob(s) and the main gas valve; provide for sufficient venting of rooms: open wide all doors and windows; do not light up any open flame, quench flames; do not smoke; do not produce sparks, do not actuate any electric switches, do not use
phones (irrespective of it being landline phone or mobile phone);
– do not operate any electric appliances in the vicinity of a gas supplied
appliance;
– if needed, notify all persons in a building by calling loud and knocking on
doors;
leave building; when outside of a building, contact the service company. If it is
impossible to precisely locate gas leak, immediately phone fire fighters and notify gas supplier.
Flammable Materials
Never use the appliance near flammable or easily combustible materials (e.g.:
petrol, spirit, alcohol). High temperature triggers evaporation of these materials, and, as a result of contact with sources of ignition, an explosion may occur.
Safety
2831021 5 / 38
EN
Use the appliance only with materials designed to this end and with correct
temperature settings. Materials, food products and left-overs of food products remaining in the appliance may catch fire.
To avoid fire hazard, clean the appliance regularly.
Never leave the appliance unattended, especially when cooking with fats or oils
as they may cause fire.
Close the gas shut-off valve should the fire emerge. Never put the flame out with
water; to suppress fire, use a lid or a fire-blanket. Following extinction of fire, ensure sufficient fresh air inflow.
Supervised Usage only
Only supervised appliance may be used.
Always remain in an immediate vicinity of the appliance.
Hot Surfaces
Surfaces of the appliance become hot during operation. Burning hazard! High
temperature remains for some time after switching the appliance off.
Do not touch any hot surfaces of the appliance. Use the provided handling
elements and holders.
You may transport and clean the appliance after it cools down entirely.
It is prohibited to sprinkle hot surfaces with cold water or flammable liquids.
Safety
6 / 38 2831021
EN
Operating Personnel
The appliance may only be operated by qualified personnel and trained
specialist personnel.
This appliance may not be operated by persons (including children) with limited
physical, sensory or mental capabilities, nor by persons with limited experience and/or limited knowledge.
Children should be supervised to ensure that they are not playing with or
switching on the appliance.
Improper Use
Unintended or prohibited use may cause damage to the appliance.
The appliance may only be used when its technical condition is flawless and
allows for safe operation.
The appliance may only be used when all connections are executed according
to rules of law in force.
The appliance may only be used when it is clean.
Use only original spare parts. Never attempt to repair the appliance on your own.
Do not introduce any changes in the appliance nor modify it.
Safety
2831021 7 / 38
EN

1.3 Residual Risks

Residual Risks
Dangerous situation
Warning
Danger of slipping or falling
User may slip on the floor due to the presence of water or dirt.
Wear non-skid safety shoes when using the device.
Burn
Operator is deliberately touches the machine components.
Operator is deliberately touching hot substances (oil, water, steam, ...).
Danger of falling
Operator performs actions on the upper part of the device using inappropriate aids (e.g. a ladder with rungs or climbs the device).
Do not work on the top of the device with unsuitable aids (e.g. ladders with rungs or by climbing on the device).
Danger of the load tipping over
Moving the device or its elements with inappropriate aids.
Appropriate lifting aids or equipment must be used when moving the device or its packaging.
Safety
8 / 38 2831021
EN
Residual Risks
Dangerous situation
Warning
Chemicals
Operator is dealing with chemicals (e.g. cleaners, descaling agents, etc.)
Appropriate precautions should be taken. Always follow the instructions on the safety data sheets and labels for the products you use. Use personal protection measures recommended in the safety data sheets.
Danger of injury
There is a risk of injury during maintenance work if you touch the internal parts of the machine frame.
Maintenance work may only be performed by qualified personnel, equipped with appropriate personal protective equipment (cut-resistant protective gloves, forearm protectors).
Danger of crushing
The personnel may crush their fingers or hands when moving parts.
Maintenance work may only be performed by qualified personnel, equipped with personal protective equipment.
Ergonomics
Operator works on the device without using the necessary personal protective equipment.
Operator working on the device must use personal protective equipment.
Safety
2831021 9 / 38
EN

1.4 Personal Protective Equipment

Phase
Safety clothing
Safety footwear
Gloves
Eye protection
Hearing protection
Respiratory tract protection
Head protection
Transport
X
Moving
X
Unpacking
X
Assembly
X
Standard usage
X X X (*)
Settings
X
Standard cleaning
X
Special cleaning
X X
Maintenance
X X (*)
Dismantling
X
Disposal
X
X Personal protective equipment provided
Personal protective equipment is available or must be used if required
Personal protective equipment not provided
* Gloves intended for standard usage and maintenance works must be resistant to
high temperatures to protect operator's hands when the operator touches hot elements of the appliance or hot substances (oil, water, steam, etc.).
Safety
10 / 38 2831021
EN

1.5 Intended Use

As described below, every use of the appliance for a purpose differing and/or diverging from its intended standard use, is prohibited and considered to be an unintended use.
The following is an intended use:
– Preparing and heating-up foods with the use of suitable cookware.

1.6 Unintended Use

An unintended use may lead to personal injuries or property damages caused by hazardous voltage, fire or high temperature. The appliance may only be used to perform tasks described in this instruction manual.
The following is an unintended use:
Heating of rooms. Heating-up flammable, hazardous to health and volatile, etc. liquids and
materials.
General information
2831021 11 / 38
EN

2 General information

2.1 Liability and Warranty

All information and instructions in this instruction manual account for legal regulations in force, current level of technical engineering knowledge as well as our expertise and experience, developed over the years. If special models or additional options are ordered, or state-of-the-art technical solutions were implemented, the actual scope of delivery of the appliance may, in some circumstances, differ from descriptions and numerous drawings in this instruction manual.
The manufacturer is not liable for any damages nor faults stemming from:
failure to observe instructions, unintended use, technical alterations introduced by the user, usage of unapproved spare parts.
We reserve the right to introduce technical modifications to the product, intended for improvement of the appliance and its performance.

2.2 Copyright Protection

This instruction manual, and texts, drawings and images included in it, as well as its other components are copyright protected. It is prohibited to reproduce this instruction manual (including its excerpts), in any form and by any means, and to
use and/or transfer its content to third parties without manufacturer’s written
permission. Violation of the above results in obligation to pay compensation. We reserve the right to claim further damages.

2.3 Declaration of Conformity

The appliance meets the currently applicable standards and guidelines of the European Union. We confirm the above in the EC Declaration of Conformity. We may provide relevant Declaration of Conformity upon request.
Transport, Packaging and Storage
12 / 38 2831021
EN

3 Transport, Packaging and Storage

3.1 Delivery Check

Immediately upon reception, check the delivery for completeness and possible shipping damage. In the case of visible transport damage refuse to accept the appliance or accept it conditionally. Mark and note the scope of damage in shipping documents/consignment list of the shipping company and lodge a complaint. Concealed damage must be reported immediately upon its discovery, as compensation claims may only be filed within applicable time limits.
If you find that parts or accessories missing, please contact our Customer Service Department.

3.2 Packaging

Do not dispose of the appliance cardboard box. It may be used to store the appliance when relocating or when shipping the appliance to our service point in the case of any damages.
The packaging and its elements are made of recyclable materials. Particularly, these are: plastic films and bags, cardboard box.
When disposing of the packaging, observe applicable domestic regulations. Recyclable packaging materials should be recycled.

3.3 Storage

Leave the packaging closed until installation of the appliance; observe external indications concerning method of placing and storage. Store the packaging in the following conditions only:
in closed rooms; in dry and dust-free surrounding; away from aggressive agents; in a location protected against sunlight; in a location protected against mechanical shocks.
In the case of extended storage (over three months), make sure you check the condition of the packaging and the parts regularly. If needed, replace the packaging with a new one.
Technical Data
2831021 13 / 38
EN

4 Technical Data

4.1 Technical Specifications

Version / Characteristics
Type: table-top appliance
Supply type: gas
Gas type:
natural gas E propane nozzles included
Hob type: gas
Ignition type: manual
Gas burner: double-ring burner
Pilot flame
Features:
stainless steel surface with Scotch-Brite finish cast-iron grates
The set includes: 4 height-adjustable feet
May be used as a table-top appliance or in connection with the base as a free-
standing appliance
It can be combined and installed in series with other 700FX series appliances
Technical Data
14 / 38 2831021
EN
Name:
Gas stove 700FX-G20
Art. No.:
2831021
Material:
stainless steel
Number of hobs:
2
Distribution of hobs, in kW, max.:
2 x 7,7
Size of hobs, in mm:
400 x 300
Gas connected load:
28.5 kW
Dimensions (W x D x H), in mm:
400 x 700 x 295
Weight, in kg:
25,0
We reserve the right to implement technical modifications.
Name:
Gas stove 700FX-G40
Art. No.:
2831041
Material:
stainless steel
Number of hobs:
4
Distribution of hobs, in kW, max.:
1 x 3,85 / 2 x 5,7 / 1 x 7,7
Size of hobs, in mm:
400 x 300
Gas connected load:
28.5 kW
Dimensions (W x D x H), in mm:
800 x 700 x 295
Weight, in kg:
42,0
We reserve the right to implement technical modifications.
Technical Data
2831021 15 / 38
EN
Name:
Gas stove 700FX-G60
Art. No.:
2832361
Material:
stainless steel
Number of hobs:
6
Distribution of hobs, in kW, max.:
2 x 3,85 / 2 x 5,7 / 2 x 7,7
Size of hobs, in mm:
400 x 300
Gas connected load:
28.5 kW
Dimensions (W x D x H), in mm:
1.200 x 700 x 295
Weight, in kg:
61,0
We reserve the right to implement technical modifications.

4.2 Functions of the Appliance

The 700FX series gas stove offers the greatest flexibility: it can be used as a table­top or a free-standing appliance. Efficient and durable: hobs are equipped with robust, enamelled cast-iron grates.
Technical Data
16 / 38 2831021
EN
Gas Pressure Table
Countries
Appliance categories
Gas pressure (mbar)
Connection pressure (mbar)
Rated
Min.
Max.
LU-PL
I2E
G20
20
17
25
NO
I2H
G20
20
17
25
NL
I2EK G20
20
17
25
G25.3
25
20
30
LU
I3+
G30/G31
28-30/37
20/25
35/45
NO-NL-CY­MT
I3B/P
G30/G31
28-30
25
35
PL
I3B/P
G30/G31
37
25
45
BE-FR
II2E+3+ G20/G25
20/25
17
25/30
G30/G31
28-30/37
20/25
35/45
PL
II2ELL3B/P G20
20
17
25
G25
20
18
25
G30/G31
50
42,5
57,5
ES-GB-GR-IE­IT-PT-SK
II2H3+ G20
20
17
25
G30/G31
28-30/37
20/25
35/45
DK-FI-SE-BG­EE-LV-LT-CZ­SI-TR-HR-RO
II2H3B/P G20
20
17
25
G30/G31
28-30
25
35
Technical Data
2831021 17 / 38
EN
Countries
Appliance categories
Gas pressure (mbar)
Connection pressure (mbar)
Rated
Min.
Max.
AT-CH
II2H3B/P G20
20
17
25
G30/G31
50
42,5
57,5
HU
II2HS3B/P G20
25
18
33
G25.1
25
18
33
G30/G31
28-30
25
35
HU
II2HS3B/P G20
25
18
33
G25.1
25
18
33
G30/G31
50
42,5
57,5
NL
II2EK3B/P G20
20
17
25
G25.3
25
20
30
G30/G31
28-30
25
35
Tab. 1
Technical Data
18 / 38 2831021
EN
Nozzles and settings
Countries
Gas type
Pa mbar
Ref.
Burner
C D E
Qn Max
Qn Min
Qn Max
Qn Min
Qn Max
Qn Min
AT-BE-BG­CH-CZ-DE­DK-EE-ES-FI­FR-GB-GR­HR-IE-IT-LT­LU-LV-NO­PL-PT-RO­SE-SI-SK-TR
G20
G20/
G25
20
20/25
UM
150R
190R
215K
UP
30 (250W)
30 (250W)
30 (250W)
A(mm)
OPEN
OPEN
10
Um
90
110
130
Qn (kW)
3,50
1,40
5,50
2,10
7,50
2,80
DE
G25
20
UM
165K
205K
245K
UP
30 (250W)
30 (250W)
30 (250W)
A(mm)
OPEN
OPEN
OPEN
Um
90
110
130
Qn (kW)
3,60
1,15
5,60
1,70
7,70
2,30
NL
G25.3
25
UM
155K
195K
220K
UP
30 (250W)
30 (250W)
30 (250W)
A(mm)
OPEN
OPEN
10
Um
90
110
130
Qn (kW)
3,50
1,30
5,60
1,90
7,50
2,60
HU
G20
25
UM
145R
180R
210K
UP
30 (250W)
30 (250W)
30 (250W)
A(mm)
OPEN
OPEN
OPEN
Um
90
110
130
Qn (kW)
3,30
1,50
5,40
2,30
7,60
3,10
Technical Data
2831021 19 / 38
EN
Countries
Gas
type
Pa
mbar
Ref.
Burner
C D E
Qn
Max
Qn
Min
Qn
Max
Qn
Min
Qn
Max
Qn
Min
HU
G25.1
25
UM
160K
200K
230K
UP
30 (250W)
30 (250W)
30 (250W)
A(mm)
OPEN 1 1
Um
90
110
130
Qn (kW)
3,60
1,25
5,60
1,75
7,50
2,50
BE-BG-CY­CZ-DK-EE­ES-FI-FR­GB-GR-HR­HU-IE-IT-LT­LU-LV-MT­NL-NO-PT­RO-SE-SI­SK-TR
G30/
G31
28-30/ 37
28-30
UM
95
120
140
UP
20 (250W)
20 (250W)
20 (250W)
A(mm)
OPEN
OPEN
OPEN
Um
90
90
100
Qn (kW)
3,60
2,50
5,70
2,70
7,60
3,40
PL
G30/
G31
37
UM
90
110
130
UP
20 (250W)
20 (250W)
20 (250W)
A(mm)
OPEN
OPEN
OPEN
Um
70
80
100
Qn (kW)
3,75
2,00
5,30
2,50
7,30
3,70
Technical Data
20 / 38 2831021
EN
Countries
Gas
type
Pa
mbar
Ref.
Burner
C D E
Qn
Max
Qn
Min
Qn
Max
Qn
Min
Qn
Max
Qn
Min
AT-CH-DE­HU
G30/
G31
50
UM
85
105
120
UP
20 (250W)
20 (250W)
20 (250W)
A(mm)
1
OPEN
OPEN
Um
70
80
80
Qn (kW)
3,85
2,30
5,50
3,00
7,50
3,00
Um: MIN nozzle
UP: Ignition burner
A: Open the air ring
Pa: Connection pressure
reg: set
Gas Consumption
Model / Art. No.
2831021 / 74GCTT 154
Rated heat load, Qn
kW
7,7
9,6
11,6
11,4
13,4
15,4
Total gas consump­tion
G20 (20)
0,81
1,01
1,22
1,21
1,42
1,63
G25.3 (25)
0,79
0,95
1,19
1,18
1,38
1,59
G25 (20)
0,95
1,18
1,42
1,40
1,65
1,90
G20 (25)
0,81
1,01
1,22
1,21
1,42
1,63
G25.1 (25)
0,95
1,17
1,42
1,40
1,65
1,89
G30 (29)
0,61
0,75
0,91
0,90
1,06
1,21
G30 (37)
0,61
0,75
0,91
0,90
1,06
1,21
G30 (50)
0,61
0,75
0,91
0,90
1,06
1,21
Tab. 2
Technical Data
2831021 21 / 38
EN
Model / Art. No.
2831041 / 78GCTT 229
Rated heat load, Qn
kW
15,4
19,1
23,1
22,8
24,8
30,8
Total gas consump­tion
G20 (20)
1,63
2,02
2,44
2,41
2,62
3,26
G25.3 (25)
1,59
1,97
2,38
2,35
2,56
3,18
G25 (20)
1,90
2,35
2,84
2,81
3,05
3,79
G20 (25)
1,63
2,02
2,44
2,41
2,62
3,26
G25.1 (25)
1,89
2,35
2,84
2,80
3,05
3,78
G30 (29)
1,21
1,51
1,82
1,80
1,96
2,43
G30 (37)
G30 (50)
Tab. 3
Model / Art. No.
2832361 / 712GCTT 345
Rated heat load, Qn
kW
23,1
30,5
32,4
42,4
34,5
38,5
38,2
46,2
Total gas consump­tion
G20 (20)
0,69
2,44
3,23
3,42
4,48
3,65
4,07
4,04
4,89
G25.3 (25)
0,75
2,38
3,15
3,34
4,37
3,56
3,97
3,94
4,76
G25 (20)
0,80
2,84
3,75
3,98
5,21
4,25
4,74
4,70
5,69
G20 (25)
0,69
2,44
3,23
3,42
4,48
3,65
4,07
4,04
4,89
G25.1 (25)
0,80
2,84
3,75
3,97
5,2
4,24
4,73
4,69
5,68
G30 (29)
0,51
1,82
2,41
2,55
3,34
2,72
3,04
3,01
3,64
G30 (37)
0,51
G30 (50)
0,51
Tab. 4
Technical Data
22 / 38 2831021
EN

4.3 List of Components of the Appliance

2831021
2831041
Technical Data
2831021 23 / 38
EN
2832361
1. Ventilation chimney
2. Cast-iron grate
3. Burner
4. Ignition burner
5. Housing
6. Knob
7. Feet (4 pcs)
Installation Instructions
24 / 38 2831021
EN

5 Installation Instructions

5.1 Installation

CAUTION!
Incorrect installation, positioning, operation, maintenance or misuse of the appliance may lead to personal injury or property damage.
Positioning and installation, as well as repairs may be performed by authorised technical service only and in compliance with the applicable national law.
NOTE!
The manufacturer disclaims all liability and provides no warranty for damages, which may be attributed to non-observance of regulations or incorrect installation.
Place of Installation
This appliance are A1 type appliances, which means that they do not have to be
connected to a fume extraction system. In order to provide venting in the place of installation, follow indications included in DVGW G631 data sheet.
Place the appliance in a well-ventilated room, under a fume extractor, if
possible, in order to eliminate fumes or odours generated when food is prepared (see DVGW G631 data sheet).
A room, in which the appliance is installed, should contain the amount of air
necessary for burning gas according to regulations in force. For proper burning, the required fresh air inflow may not be lower than 2 m3/h per kW of appliance's rated power (see appliance's rated plate). Additionally, accident prevention regulations should be observed.
Make sure that there are no objects near or under the appliance that may
restrict the amount of air necessary for burning.
Before placing the appliance, check the dimensions and exact position of gas
connections.
Installation Instructions
2831021 25 / 38
EN
Observe all provisions of law, guidelines and regulations during installation:
Regional or local safety regulations and construction law provisions Accident prevention acts in force Fire prevention provisions Respective IEC provisions DVGW G600 (TRGI), 'Technical regulations for gas installations' TRF, 'Technical regulations for liquid gas' Directive and regulations of a gas supplying company (EUV) DVGW G 631, 'Installation of commercial kitchen appliances for
combustion of gas fuels'
– Respective legal regulations
Unpacking / Positioning
Unpack the appliance, remove all external and internal packaging elements and
shipment safeguards.
CAUTION!
Choking hazard!
Prevent children from accessing package materials, for instance: plastic bags and EPS.
If the appliance is covered with a protective film, remove it. Remove the film
slowly, so no glue residues are left. Remove any glue residues with the use of a suitable solvent.
Be careful not to damage the rating plate and warning labels fixed on the
appliance.
Never place the appliance in humid or wet environment.
Place the appliance in a way making the connections easily accessible, so that
they may be quickly disconnected if such a need arises.
The appliance should be placed on surfaces that are:
even, with sufficient bearing capacity, resistant to water, dry and resistant
to high temperatures;
– sufficiently large, and thus enabling usage of the appliance with no
problems;
easily accessible; well ventilated.
Installation Instructions
26 / 38 2831021
EN
Screw 4 feet in.
To level the appliance, you may adjust the height of feet.
IMPORTANT! Never use the appliance without feet.
Maintain sufficient clearance from table edges. The appliance might turn over
and fall down.
Never place the appliance directly next to walls, furniture, or other objects made
of flammable materials. Maintain minimum clearance of 200 mm between side and rear walls and the said objects and walls. Maintain clearance of at least 600 mm between the appliance's surface and horizontal surfaces over the appliance.
If keeping the minimum clearance is not possible, walls should be isolated with
non-combustible, thermo-insulation materials (e.g., films made of heat resistant materials, which may sustain temperature of at least 65°C). Follow fire protection regulations in force.
When adjusting the feet, level the appliance and set its height. Considerable
differences in height or tilting may negatively affect the appliance's operation.
Connection to Gas Installation
Before making the connection to gas installation, make sure that the appliance
is set to gas and pressure is available in the installation location (see rating plate on the appliance and packaging). If factory default settings are not suitable, the appliance must be adapted to the available gas type (section 'Resetting to Other Type of Gas / Required Adjustments').
The attested gas shut-off valve must be installed in an easily accessible location
between the gas supply installation and the appliance, so that, if needed, gas supply may be interrupted at any time.
Check if the gas cylinder (if it is included) is correctly set up and secured, and if
it is located in a dry place.
Connect the appliance to the gas supply installation, using rigid connection
tubes or flexible steel hoses, with section suitable for the given rated power and length.
Use only connection tubes with, at least, diameters equalling the diameter of the
appliance's gas connection. Gas connection stub is found at the back of the appliance.
Make sure that flexible hoses do not run on or near hot surfaces, are not subject
to stress or pressure and do not come into contact with sharp edges or other objects that could damage the tube.
Installation Instructions
2831021 27 / 38
EN
After connecting the appliance, all connection points between the installation
and the appliance must be subject of tightness check. To this end, use spray for detecting leakages or foam producing agents, which do not spur corrosion. Connection points should be covered with an agent - no air bubbles should be produced. Also the gas shut-off valves should be subject of this check.
WARNING! Do not use open fire to test tightness.
Checking Gas Pressure and Rated Heat Load
With first installation, the gas installation technician must verify the appliance's
rated heat load, as well as conduct maintenance, and, if needed, resetting to other type of gas.
DO NOT attempt to increase the power nor rated heat load specified by the
manufacturer.
Check the rated heat pressure with gas meter and a stop watch. Measure
exactly the amount of gas flowing per unit of time the appliance is consuming with maximum power.
Compare the measured value with data on consumption in section 'Technical
Specifications', Table 3. Admissible deviation is ±5%.
Check the gas supply pressure observing indication in section 7.3
„Maintenance / Gas Supply Pressure Check“.
Resetting to Other Type of Gas / Required Adjustments
The appliances are set to the following gas type/category:
Natural gas E
Check the type of the supplied gas in the country of installation, and, if needed, reset the appliance to the other gas type.
Tables 1 and 2 in section 'Technical Specifications' provide, depending on the country of installation:
what gas types may be used to power the appliance; nozzles and settings for each gas type that is used.
The number provided in Table 2 for proper nozzles is pressed on nozzles' bodies. In order to adapt the appliance to the gas type, with which it may be effectively
operated, collect data from Table 2 and perform the following actions:
Installation Instructions
28 / 38 2831021
EN
exchange main burner's nozzle (UM) fit main burner air controller within the distance A exchange ignition burner's nozzle (UP) perform air adjustment of ignition burner (if needed).
Exchange of Main Burner Nozzle / Primary Air Adjustment
Fig. 1
Fig. 2
1. Remove the knob.
2. Remove cast-iron grates and burners.
3. Remove main burner's nozzle, UM (Fig. 1), and exchange it with a nozzle
provided in Table 2 (part of the delivery).
4. Re-tighten main burner's nozzle, UM.
Installation Instructions
2831021 29 / 38
EN
Exchange of Ignition Burner Nozzle
1. Remove the front guard / operation panel.
2. Unscrew the R connection.
3. Remove the UP nozzle and exchange it with a nozzle provided in Table 2 (part of the delivery).
4. Re-tighten the R connection.
5. Reinstall removed elements in reverse order.
Fig. 3
When the nozzles are exchanged, it is necessary to verify functions of the appliance, as set forth in section 'Verification of Functions'.
To end with, exchange the old rating plate to a new one, included in the delivery, and containing different data and indication of the new type.
Functional Check
Before test-running, install the appliance in a well ventilated room and remove any flammable materials from the vicinity of the appliance.
Before starting, perform the tightness test using soapsuds. Cover connections and pipe fittings with suds. Leakages are revealed when bubbles are produced on couplings and pipe connections. Other method involves observation of gas meter. No reaction of gas meter indicates that there are no gas leakages.
WARNING! Do not use open flame for checking tightness of gas installation!
Restart the appliance, observing indications in section 'Appliance Start-up'.
Check the appliance for gas tightness (see DVGW data sheets, TRGI/TRF).
Verify burner's ignition.
Verify flame shape.
Operating Instruction
30 / 38 2831021
EN

6 Operating Instruction

Indications for the User
Read carefully this instruction manual. It contains important indications for installation, usage and maintenance of the appliance.
Before operating the appliance, make sure that its condition is flawless and that it is located in a well ventilated room.
Always strictly observe the following safety precautions:
Check if there are no objects near or under the appliance that may
restrict the amount of air necessary for burning.
Never cover ventilation and discharge openings in the appliance. If the malfunction persists, do not use the appliance and order gas
installation technician's visit.
– Any manipulation with the appliance, assembly or maintenance work
may be performed exclusively by the authorized service personnel.
– The user is authorized to perform only everyday routine cleaning to
maintain the device in a good condition.
– The appliance should be used solely for grilling of suitable food products;
do not use it for any other purposed. The use against the intended purpose may lead to severe injury or damage caused by, for example, high temperatures and fire, etc.
Never leave the operating appliance without supervision. If the appliance is not to be used any more, rotate the gas controller(s) to
OFF position and close the gas shut-off valve in the gas line.
Operating Instruction
2831021 31 / 38
EN

6.1 Operation

WARNING
Risk of burning! During operation, the housing and working surface become very hot
and remain hot for a while after switching the appliance off.
Do not touch the appliance! To control the appliance, use only designated control elements.
The grease collection container and its contents are very hot.
Empty the grease collection container only when it has cooled down.
Fire hazard!
Never place any kitchen utensils, towels, paper, etc., on the working surface during operation. Do not place plastic containers on the working surface.
Preparation of the Appliance
1. Before use, clean the appliance, observing instructions in section 6 'Cleaning'.
2. Dry the appliance thoroughly.
Operating Instruction
32 / 38 2831021
EN
3. Install burners.
4. Correctly fix gas burner guards.
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
5. Install cast-iron grates.
Operating Instruction
2831021 33 / 38
EN
Reinigen Sie das Gerät und Zubehörteile vor dem Ge brauch gründlic h nach den Anweis ungen im Absch nitt 6 „Reinigung“ . Achten Si e darauf, dass keine Feuch tigkeit in die el ektrische Anl age bzw. den Sch altkasten eindri ngt. Następnie d okładnie osuszyć urządzenie and the entire equipment.
Insert the bottom cover into the appliance. The cover acts as a spacer between t he heating element and left-over food tr ay.
Carefully insert the connection box with th e heating element at the back edge of th e appliance. A pin in bottom part of the c onnection box must enter a hole in t he main appliance. This way the connectio n box is properly mounted.
Appliance Start-up
The appliances are equipped with 2, 4 or 6 burners and, respectively, in separate control elements, owing to which the grilling zones may be used and set-up separately. Each time, the below description pertains to one burner.
1. Knob
2. OFF position (0)
3. Ignition flame lighting up
4. Large flame
5. Small flame
Fig. 10
Ignition flame lighting up
1. Press the knob (1) and rotate it to position (3).
2. Press the knob entirely (1) and light the ignition burner with a small flame.
3. Keep the knob (1) pressed for approx. 20 seconds, and then release it. If the ignition flame is out, repeat the process.
Switching Main Burner On
1. Rotate the knob (1) from position (3) to position (4).
2. Depending on the desired thermal processing temperature, rotate the knob (1) to the desired position between (4) and (5).
Switching Off
1. To switch the main burner off, rotate the knob (1) to position (3).
2. To switch the ignition burner off, press and hold the knob (1), while rotating it to off position (2).
Operating Instruction
34 / 38 2831021
EN
Heating Up / Keeping Food Warm
WARNING! The food in containers may slide or fall if the appliance is not set on even
and stable surface.
Pay attention to the surface you are putting cookware taken off of the appliance. Never move the appliance with food on top of it; remove the food first. Use protective gloves when moving cookware.
1. Place an appropriate cookware with food on the heating plate.
ATTENTION! Do not place an empty cookware on the hob, as otherwise, this may result
in damage to the appliance and cookware.
2. Select the required setting, suitable for the processed product.
3. Prepare food.
Switching the Appliance OFF
1. If the appliance is not used, rotate the knob to '0' position.
2. Close the gas shut-off cock.
Cleaning and Maintenance
2831021 35 / 38
EN

7 Cleaning and Maintenance

7.1 Safety Instructions for Cleaning

Close the gas supply valve before cleaning.
Leave the appliance to cool down completely.
Do not clean the appliance with a pressurized water jet.
Do not use any sharp or pointed, nor metal implements (knife, fork, etc.). Sharp
or pointed objects may damage the appliance.
For cleaning, do not use any scouring agents that contain solvents nor corrosive cleaning agents. They may damage the surface.

7.2 Cleaning

Gas Hob
1. Clean the appliance regularly at the end of each working day, and, if necessary, also in the meantime or when the appliance is not to be used for a longer time.
2. Remove cast-iron grates and gas burners guards.
3. Clean the hob and housing using a soft cloth or sponge soaked in warm water. Use neutral cleaning agent when required.
4. Use a clean cloth to wipe the hob and housing, and dry the cleaned surfaces thoroughly.
5. Clean cast-iron grates and gas burner guards with a neutral washing agent and a soft cloth or sponge. To end with, rinse them thoroughly in fresh water and dry.
6. After cleaning, re-fit gas burner guards and cast-iron grates correctly.
Cleaning and Maintenance
36 / 38 2831021
EN

7.3 Maintenance

ATTENTION!
Any works interfering in the appliance must be performed by professional and qualified personnel.
We recommend to order the maintenance of the appliance with the qualified and authorised maintenance technician at least twice a year.
Perform the following maintenance works:
– Operation verification of the available control elements and protective
devices;
Verification of the flame; Verification of the ignition; Verification of the flame's safety; Verification of functions.
Operate the appliance observing the instruction manual and indications in section 'Indications for the User' and check:
gas supply pressure (see next section). correct switching of burners and operation of the fume extractor
(chimney).
Gas Supply Pressure Check
Use a suitable manometer with 0.1 mbar minimum pitch.
Remove operating panels. Remove the retaining screw from the pressure connection. Connect the manometer. Perform the measurement with an operating appliance. Disconnect the manometer and re-tighten the retaining screw back to the
pressure connection.
ATTENTION! If the gas supply pressure is outside the limit values range (min. – max.) in
Table 2, interrupt the appliance's operation and contact local gas supply operator.
Possible Malfunctions
2831021 37 / 38
EN
Cleaning Performed by the Maintenance Technician
At least twice a year, have the authorised maintenance technician perform the cleaning of the appliance's interior.

8 Possible Malfunctions

Mögliche
The table below contains descriptions of possible causes and solutions to malfunctions or errors during operation of the appliance. When malfunction cannot be removed, contact the technical service.
Problem
Possible Cause
Solution
Ignition burner does not switch on
Insufficient gas supply pressure
Check gas supply Clogged line or nozzles
Contact the service company
Spark plug is incorrectly connected or damaged
Connect spark plug or replace it
Igniter or spark plug line is damaged
Contact the service company Damaged knob
Contact the service company
Ignition burner does not switch on or goes out when the knob or piezoelectric igniter is released
Thermo-element is incorrectly connected to the knob
Contact the service company
Thermo-element is damaged or insufficiently heated up by the ignition burner
Repeat the ignition process
Damaged knob
Contact the service company
Knob has not been pressed sufficiently long
Keep the knob pressed for approx. 20 seconds
Damaged gas fittings
Contact the service company
Disposal
38 / 38 2831021
EN
Problem
Possible Cause
Solution
Main burner does not switch on when the ignition burner is on
Loss of pressure in gas supply line
Check gas supply
Clogged line or nozzles
Contact the service company Damaged knob
Contact the service company
Main burner is damaged or gas outlet openings are clogged
Contact the service company
Heating power output control is not possible
Damaged knob
Contact the service company

9 Disposal

At the end of the appliance's operational life cycle, dispose of the appliance, observing national and local regulations. To this end, we recommend contacting a professional company or local authorities' unit, proper for utilisation matters.
Before disposing of the appliance make sure that the appliance cannot be restarted to prevent any abuse and related risks, and then deliver it to the local collection point.
Loading...