Bartscher 2x5L-F, 3x5L-F, 700940, 700941 Operating instructions

2x5L-F - 3x5L-F
700940 - 700941
Bartscher GmbH Franz-Kleine-Str. 28 D-33154 Salzkotten Germany
Phone: +49 5258 971-0 Fax: +49 5258 971-120 Service hotline: +49 5258 971-197 www.bartscher.com
Version: 1.0 Date of preparation: 2023-03-24
EN 2
Original instruction manual
1 Safety ............................................................................................................ 2
1.1 Explanation of Signal Words .................................................................... 2
1.2 Safety instructions.................................................................................... 3
1.3 Intended Use ........................................................................................... 6
1.4 Unintended Use ....................................................................................... 6
2 General information ....................................................................................... 7
2.1 Liability and Warranty .............................................................................. 7
2.2 Copyright Protection ................................................................................ 7
2.3 Declaration of Conformity ........................................................................ 7
3 Transport, Packaging and Storage ................................................................ 8
3.1 Delivery Check ......................................................................................... 8
3.2 Packaging ................................................................................................ 8
3.3 Storage .................................................................................................... 8
4 Technical Data ............................................................................................... 9
4.1 Technical Specifications .......................................................................... 9
4.2 List of Components of the Appliance ..................................................... 11
4.3 Functions of the Appliance ..................................................................... 13
5 Installation and operation ............................................................................ 13
5.1 Installation .............................................................................................. 13
5.2 Operation ............................................................................................... 15
6 Cleaning and Maintenance .......................................................................... 24
6.1 Safety Instructions for Cleaning ............................................................. 24
6.2 Cleaning ................................................................................................. 24
6.3 Maintenance .......................................................................................... 25
7 Possible Malfunctions .................................................................................. 26
8 Disposal ....................................................................................................... 28
700940 1 / 28
Safety
EN
Read this instruction manual before using and keep it available at all times!
DANGER!
The signal word DANGER warns against hazards that lead to severe injuries or death if the hazards are not avoided.
Diese Bedienungsanleitung beschreibt di e Installation, Bedienung und Wartung d es Geräts und gilt als wichtige Infor mationsquelle und Nachschlagewer k. Die Kenntnis aller enthaltenen Sicherh eitshinweise und Handlungsanw eisungen schafft die Voraussetzung f ür das sichere und sachgerechte Ar beiten mit dem Gerät. Darüber hinaus müssen die für den Einsatzbereic h des Geräts geltenden örtlichen Unfall verhütungsvorschriften und allgemeine n Sicherheitsbestimmungen eingehalten werden. Diese Bedienungsanleitung is t Bestandteil des Produkts und muss in unmittelbarer Nähe des Geräts für das In¬stallations-, B edienungs-, Wartungs- und Reinigungsp ersonal jederzeit zugänglich auf¬be wahrt werden. Wenn das Gerät an eine dritte Person weitergegeben wird, muss die Bedienungsa nleitung mit ausgehändigt werden.
This instruction manual contains information about installation, operation and maintenance of the appliance and constitutes an important source of information and reference guide. The knowledge of all operational and safety instructions included in this manual is a prerequisite for safe and proper handling of the appliance. Additionally, accident prevention, occupational health and safety, and legal regulations in force in the area the appliance is used apply.
Before you start using the appliance, especially before turning it on, read this instruction manual in order to avoid personal injuries and property damages. Improper use may cause damage.
This instruction manual forms and integral part of the product and must be stored in an immediate vicinity of the appliance and be available at all times. The instruction manual should be transferred together with the appliance.

1 Safety

This appliance has been manufactured in accordance with technical standards currently in force. However, the appliance may be a source of hazards if used improperly or contrary to its intended purpose. All persons using the appliance must consider information included in this instruction manual and observe safety instructions.

1.1 Explanation of Signal Words

Important safety instructions and warning information are indicated in this instruction manual with appropriate signal words. You must strictly follow the instructions, to prevent accidents, personal injuries and property damages.
2 / 28 700940
Safety
EN
WARNING!
The signal word WARNING warns against hazards that may lead to moderate or severe injuries or death if the hazards are not avoided.
CAUTION!
The signal word CAUTION warns against hazards that may lead to light or moderate injuries if the hazards are not avoided.
IMPORTANT!
The signal word IMPORTANT indicates possible property damages, which may occur if safety instructions are not observed.
NOTE!
The symbol NOTE indicates subsequent information and guidelines for the user on usage of the appliance.
, die

1.2 Safety instructions

Electrical Current
Too high a mains voltage or incorrect installation may cause electric shock.
The appliance may be connected only if data on the rating plate correspond with
the mains voltage.
To avoid short-circuit, the appliance should be kept dry.
If there are malfunctions during operation, disconnect the appliance from the
power supply.
• Do not touch the appliance’s plug with wet hands.
Never take hold of the appliance if it has fallen into water. Immediately
disconnect the appliance from the power supply.
Any repairs or housing opening may be carried out by professionals and
relevant workshops only.
Do not transport the appliance, holding it by the power cord.
Do not allow the power cord to come into contact with heat sources or sharp
edges.
Do not bend, pinch nor knot the power cord. 700940 3 / 28
Safety
EN
Always completely unwind the power cord.
Never place the appliance or other objects on the power cord.
Always take hold of the plug to disconnect the appliance from the power supply.
Check the power cord regularly for damage. Do not use the appliance if the
power cord is damaged. If this cable is damaged, it must be replaced by customer service or a qualified electrician in order to avoid dangers.
Incorrect operation of the appliance ma y cause fire or explosion hazard due to igniti on of its content.
Fire hazard / flammable materials hazard / explosion hazard!
Do not use any electric devices in the appliance.
Do not store nor use petrol or other flammable liquids and gases in the vicinity of
this or any other appliance. Those gases may cause fire or explosion hazard.
Do not put into the appliance any explosive materials, like sprays filled with
flammable propellants. Contents of containers filled with flammable gases and liquids may leak in low temperatures, and the contents may catch fire from sparks generated by an electric appliance. Explosion hazard!
In the case of coolant leakage, pull the plug from the socket. Remove all
sources of ignition in the vicinity, ventilate room and contact technical service. Avoid coolant getting in contact with eyes, as it may cause serious eye damage.
Never use any flammable liquids for cleaning the appliance or its parts. Gases
released may cause fire or explosion hazard.
In the case of fire, disconnect the appliance from the power supply before
attempting adequate fire-extinguishing actions.
Never attempt to extinguish fire with water if the appliance is connected to the
power supply. Following extinction of fire, ensure sufficient fresh air inflow.
Defrosting process may not be sped up with mechanical means or heat energy
sources (candles or heaters) nor with any other means. Vapour produced may cause short-circuit and too high temperatures may damage the appliance.
All ventilation slots should not be obstructed during operation.
Never attempt to damage cooling installation of the appliance.
4 / 28 700940
Safety
EN
Operating Personnel
The appliance may only be operated by qualified personnel and trained
specialist personnel.
This appliance may not be operated by persons (including children) with limited
physical, sensory or mental capabilities, nor by persons with limited experience and/or limited knowledge.
Children should be supervised to ensure that they are not playing with or
switching on the appliance.
Improper Use
Unintended or prohibited use may cause damage to the appliance.
The appliance may only be used when its technical condition is flawless and
allows for safe operation.
The appliance may only be used when all connections are executed according
to rules of law in force.
The appliance may only be used when it is clean.
Use only original spare parts. Never attempt to repair the appliance on your own.
Do not introduce any changes in the appliance nor modify it.
Do not drill hole in the appliance nor install any objects on it.
Do not place any heavy objects on the appliance.
700940 5 / 28
Safety
EN

1.3 Intended Use

As described below, every use of the appliance for a purpose differing and/or diverging from its intended standard use, is prohibited and considered to be an unintended use.
The following is an intended use:
– Storing ice cream for on-going preparation of desserts in professional
kitchens.
The appliance is intended for operation in maximum ambient temperature of 40°C and relative humidity of 55%.

1.4 Unintended Use

An unintended use may lead to personal injuries or property damages caused by hazardous voltage, fire or high temperature. The appliance may only be used to perform tasks described in this instruction manual.
The following is an unintended use:
prolonged storage of ice cream; Storing flammable or explosive objects and liquids, such as ether,
petroleum or adhesives;
Storing explosive materials, like sprays filled with flammable propellants; Storing pharmaceutical products or preserved blood; Storing live pets.
6 / 28 700940
General information
EN

2 General information

2.1 Liability and Warranty

All information and instructions in this instruction manual account for legal regulations in force, current level of technical engineering knowledge as well as our expertise and experience, developed over the years. If special models or additional options are ordered, or state-of-the-art technical solutions were implemented, the actual scope of delivery of the appliance may, in some circumstances, differ from descriptions and numerous drawings in this instruction manual.
The manufacturer is not liable for any damages nor faults stemming from:
failure to observe instructions, unintended use, technical alterations introduced by the user, usage of unapproved spare parts.
We reserve the right to introduce technical modifications to the product, intended for improvement of the appliance and its performance.

2.2 Copyright Protection

This instruction manual, and texts, drawings and images included in it, as well as its other components are copyright protected. It is prohibited to reproduce this instruction manual (including its excerpts), in any form and by any means, and to
use and/or transfer its content to third parties without manufacturer’s written
permission. Violation of the above results in obligation to pay compensation. We reserve the right to claim further damages.

2.3 Declaration of Conformity

The appliance meets the currently applicable standards and guidelines of the European Union. We confirm the above in the EC Declaration of Conformity. We may provide relevant Declaration of Conformity upon request.
700940 7 / 28
Transport, Packaging and Storage
EN

3 Transport, Packaging and Storage

3.1 Delivery Check

Immediately upon reception, check the delivery for completeness and possible shipping damage. In the case of visible transport damage refuse to accept the appliance or accept it conditionally. Mark and note the scope of damage in shipping documents/consignment list of the shipping company and lodge a complaint. Concealed damage must be reported immediately upon its discovery, as compensation claims may only be filed within applicable time limits.
If you find that parts or accessories missing, please contact our Customer Service Department.

3.2 Packaging

Do not dispose of the appliance cardboard box. It may be used to store the appliance when relocating or when shipping the appliance to our service point in the case of any damages.
The packaging and its elements are made of recyclable materials. Particularly, these are: plastic films and bags, cardboard box.
When disposing of the packaging, observe applicable domestic regulations. Recyclable packaging materials should be recycled.

3.3 Storage

Leave the packaging closed until installation of the appliance; observe external indications concerning method of placing and storage. Store the packaging in the following conditions only:
in closed rooms; in dry and dust-free surrounding; away from aggressive agents; in a location protected against sunlight; in a location protected against mechanical shocks.
In the case of extended storage (over three months), make sure you check the condition of the packaging and the parts regularly. If needed, replace the packaging with a new one.
8 / 28 700940
Technical Data
EN
Name:
Ice cabinet 2x5L-F
Art. No.:
700940
Material:
Steel | plastic
Number of GN containers:
2x 1/3 GN 5 litres | 4x 1/6 GN 2.5 litres
Max. container depth, in mm:
150
Volume, in l:
10
Temperature range, min.–max., in °C:
-10 °C - -22 °C
Amount of coolant, in kg:
R600a / 0,022
Climate class:
4
Energy efficiency class:
A (EU Nr. 2019 / 2018)
Energy consumption, in kWh/year:
537
Connected load:
0,184 kW | 220-240 V | 50 Hz
Dimensions (W x D x H), in mm:
465 x 715 x 355
Weight, in kg:
24,4

4 Technical Data

4.1 Technical Specifications

We reserve the right to implement technical modifications.
700940 9 / 28
Technical Data
EN
Name:
Ice cabinet 3x5L-F
Art. No.:
700941
Material:
Steel | plastic
Number of GN containers:
3x 1/3 GN 5 litres | 6x 1/6 GN 2.5 litres
Max. container depth, in mm:
150
Volume, in l:
15
Temperature range, min.–max., in °C:
-10 °C - -22 °C
Amount of coolant, in kg:
R600a / 0,024
Climate class:
4
Energy efficiency class:
A (EU Nr. 2019 / 2018)
Energy consumption, in kWh/year:
637
Connected load:
0,184 kW | 220-240 V | 50 Hz
Dimensions (W x D x H), in mm:
650 x 720 x 355
Weight, in kg:
28,8
We reserve the right to implement technical modifications.
Version / Characteristics
Colour: white
Type of glazing: double glazing, safe glass
Temperature control: electronic
Internal lighting: LED
Door type: lifting door
Door position: top side
Digital display
Control: electronic
The set includes: support for GN containers
Note: Delivery without GN containers
10 / 28 700940
Technical Data
EN
Fig. 1
1. GN container bracket
2. Cooling compartment
3. Shelf with a grate
4. Digital temperature controller
5. Ventilation openings
6. Glass pane door handle
7. LED lighting
8. Housing
9. Glass pane door

4.2 List of Components of the Appliance

700940
700940 11 / 28
EN
Fig. 2
1. GN container bracket
2. Cooling compartment
3. Shelf with a grate
4. Digital temperature controller
5. Ventilation openings
6. Glass pane door handle
7. LED lighting
8. Housing
9. Glass pane door
700941
Technical Data
12 / 28 700940
Installation and operation
EN
CAUTION!
Incorrect installation, positioning, operation, maintenance or misuse of the appliance may lead to personal injury or property damage.
Positioning and installation, as well as repairs may be performed by authorised technical service only and in compliance with the applicable national law.
NOTE!
The manufacturer disclaims all liability and provides no warranty for damages, which may be attributed to non-observance of regulations or incorrect installation.
CAUTION!
Choking hazard!
Prevent children from accessing package materials, for instance: plastic bags and EPS.

4.3 Functions of the Appliance

The ice cream cabinet is a solution for optimum storage of self-made ice cream desserts at the right temperature for the desired period of time. The lowered
containers minimise the formation of ice on surfaces.

5 Installation and operation

5.1 Installation

Unpacking / Positioning
Unpack the appliance, remove all external and internal packaging elements and
shipment safeguards.
If the appliance is covered with a protective film, remove it. Remove the film
slowly, so no glue residues are left. Remove any glue residues with the use of a suitable solvent.
Be careful not to damage the rating plate and warning labels fixed on the
appliance.
700940 13 / 28
Installation and operation
EN
Never place the appliance in humid or wet environment.
Place the appliance in a way making the connections easily accessible, so that
they may be quickly disconnected if such a need arises.
The appliance should be placed on surfaces that are:
even, with sufficient bearing capacity, resistant to water, dry and resistant
to high temperatures;
– sufficiently large, and thus enabling usage of the appliance with no
problems;
easily accessible; well ventilated.
Maintain sufficient clearance from table edges. The appliance might turn over
and fall down.
Nie należy umieszczać urządzenia w gorąc ym otoczeniu a ni w pobliżu m ateriałów łat wopalnych.
The appliance requires sufficient airflow f or proper operation. Assure a minim um lateral clearance of the appliance of 1 0 cm.
Never cover nor block ventilation slots of t he appliance.
Do not place the appliance in direct sunlight or in the vicinity of heat sources
(cooker, radiator, heating devices, etc.). Heat sources may pose negative effect in terms of power consumption and lead to restrictions in operation of the appliance.
Place the appliance so that sufficient air circulation is ensured. Leave 10 cm
clearance from walls and other objects.
The appliance may be installed only in rooms, in which ambient temperature
does not exceed 30°C.
In order to avoid compressor’s damage, do not tilt the appliance more than 45°
when positioning or transporting it.
If the appliance is to be relocated, follow the instructions below:
switch the appliance off; remove the plug from the socket; take out contents of the appliance; us a tape to stick up all loose elements inside the appliance and the
door;
the appliance may only be transported in upright position.
The electric socket should be easil y accessible so it is possible to quickly disconnect th e power cable w hen necessar y.• The electric socket should be easil y accessible so it is possible to quickly discon nect the power cable when necessar y. The electric socket should be easily accessibl e so it is possible to quickly disconnect t he power cable when necessar y.
14 / 28 700940
Installation and operation
EN
Power supply connection
Verify if technical data of the appliance (see rating plate) correspond with the
local electric power grid specification.
Connect the appliance to a single, properly grounded mains socket with
protective contact. Do not connect the appliance to a multi-socket.
The power cord should be laid in a way preventing anyone from threading on it
or tripping against it.
Prior to first use, the appliance should be installed and left standing upright for at
least 2 hours, before it is connected to power supply.
After a power failure or when the plug is removed from the socket, do not
reconnect the appliance to power supply for at least 5 minutes.

5.2 Operation

Prior to first operation, clean the appliance and its equipment, observing instructi ons in section 6 'Cleaning'. Make sure no water enters electric installatio n and connection box. Then thoroughl y dry the appliance and the entire eq uipment.
Insert the bottom cover into the applianc e. The cover acts as a spacer between t he heating element and left-over f ood tray.
Carefully insert the connection box with th e heating element at the back edge of t he appliance. A pin in the bottom part o f the connection box must enter a hole in the main appliance. This wa y the connection box is properly mounte d.
Appliance Preparation
1. Prior to first operation, clean the appliance inside and outside, as well as the
glass pane door and the GN container bracket according to instructions in section 6 'Cleaning'.
2. Finally, thoroughly dry the cleaned surfaces and elements.
3. Place the support in the cooling compartment of the appliance.
4. Tightly close the appliance lid.
5. Plug the appliance into a suitable single socket.
6. Switch the appliance on according to instructions in section 'Switching the
Appliance ON/OFF'. The digital display shows current temperature inside the appliance. The appliance will be cooled down to the factory pre-set temperature.
7. Ice cream should be placed in the appliance only when it reaches the right
temperature.
8. If needed, the temperature may be altered with digital temperature controller
keys. Follow indications in subsequent sections of the instruction.
700940 15 / 28
Installation and operation
EN
1.
Digital Display
2.
Fan LED indicator
LED on: fan activated LED blinks: evaporator fan is disconnected
3.
Defrosting process LED indicator
LED on: defrosting in progress LED blinks:
– defrosting was requested, but compressor protection
has tripped
dripping is in progress defrosting was requested, but compressor is in
minimum start-up mode
4.
Compressor LED indicator
LED on: compressor off LED blinks:
setting the parameters of cooling mode in progress compressor fuse tripped
Digital Temperature Controller
Functions of Operating Elements and Displays
16 / 28 700940
Installation and operation
EN
5.
Energy-saving mode LED indicator
LED and digital display are on: the energy-saving mode is activated
LED and digital display are off: the appliance is in 'sleep' mode
Press the key to activate the display
6.
LED indicator of Celsius scale
LED on: the temperature measurement unit are degrees Celsius
LED indicator of Fahrenheit scale
LED on: the temperature measurement unit are degrees Fahrenheit
7.
LED AUX
LED on:
alarm is activated interior lighting is in manual mode
LED blinks: when the door switch is pressed, the lighting is switched on
8.
LED ON/Standby indicator
LED on: Appliance is switched off (Standby)
9.
Setting value increase key manual defrosting
10.
Activate / Deactivate key | Reduce setting values
11.
Interior lighting key | ON/Standby
12.
Locking key | Programming key
700940 17 / 28
Installation and operation
EN
General Information
The appliance may feature the following status:
ON: The appliance is connected to the power supply and switched on
with the ON/OFF key of the digital temperature controller.
Standby: The appliance is connected to the power supply, but the very
appliance is switched off by the software; the temperature regulator is switched off.
OFF: The appliance is not connected to the power supply.
Switching the Appliance ON/OFF
1. Plug the appliance into a suitable single socket.
2. Make sure that the digital temperature controller keys are not blocked and there
are no on-going processes (defrosting, cooling, etc.).
3. Press and hold the key for 4 seconds. The LED flashes and the appliance is switched on or off.
Digital Display
When the appliance is switched on, in normal operation the digital display of the appliance shows P5 parameter, except for defrosting, when the temperature set by d6 parameter is displayed. The LED indicator lights can be switched on.
When the appliance is switched off, no values appear on the digital display. The LED indicator light is on.
When the appliance is in 'sleep mode', the digital display is off and the LED indicator light is on.
18 / 28 700940
Installation and operation
EN
Value
Displayed temperature
Pb1
Room temperature
Pb2
When the P4 parameter is set to 1 or 2, the evaporator temperature is displayed
When the P4 parameter is set to 3, the condenser temperature is displayed
Indicator Light of the Temperature Measured by Probes
1. Make sure that the keys are not blocked and there is no process in progress.
2. Press and hold the key for 4 seconds. The digital display shows the first available value.
3. Press the or key to set the time.
4. Press the key and release it again. The table below shows the assignment of a value and the displayed temperature.
To end the procedure:
5. Press the key briefly or refrain from inputting any data for 60 seconds.
6. Press the key and release it again. If there is no second analogue input (i.e. if the P4 parameter is set to 0), the 'Pb2'
value is not displayed.
Manual Defrosting Activation
1. Make sure that the keys are not blocked and there is no process in progress.
2. Press and hold the key for 4 seconds. The defrosting is activated immediately.
The LED indicator light starts to illuminate and remains on as long as the defrost process is in progress.
If the compressor probe acts as a defrost probe (the P4 parameter is set to 1) and the compressor temperature at the time of defrost activation is higher than the temperature set by the d2 parameter, defrost will not be activated.
700940 19 / 28
Installation and operation
EN
Internal lighting in manual ON/OFF modes
1. Make sure that the keys are not blocked and there is no process in progress. The u2 parameter is displayed.
2. Press the key briefly. The LED light switches ON/OFF.
Key Locking/Unlocking
Key Locking:
1. Make sure, there is no process in progress.
2. Do not enter any data for 30 seconds: the 'Loc' indication will be shown in the
digital display for 1 second and the keypad will be automatically locked.
When the keypad is locked, the following functions are not available:
switching the appliance ON/OFF displaying the temperature measured by the probe activating the manual defrosting process setting the working temperature
If you attempt to introduce these settings, there will be the 'Loc' indication shown in the display for 1 second.
Key Unlocking:
3. Unlock the keys before you attempt to introduce the data.
4. To unlock the keys, press and hold one of the keys for 1 seconds. The 'UnL' indication will be shown in the display for 1 second.
Setting Set-Point Operation
1. Make sure that the keys are not blocked and there is no process in progress.
2. Press the key briefly. The LED indicator light blinks.
3. Within 15 seconds, press the or key briefly. The digital display shows the parameters: r1 (min. temperature) and r2 (max.
temperature).
20 / 28 700940
Installation and operation
EN
Alarm Code
Description
Solution
Outcomes
AL
Minimum temperature alarm
Check the room temperature (A1 parameter)
The alarm output is activated
AH
Maximum temperature alarm
Check the room temperature (A4 parameter)
The alarm output is activated
id
Door micro-switch input alarm
Check what caused the input to be activated (i0 and i1 parameters)
The effect is set with the i0 parameter
The alarm output is activated
iA
Multifunction input alarm or pressure switch alarm
Check what caused the input to be activated (i0 and i1 parameters)
The effect is set with the i0 parameter
The alarm output is activated
COH
Overheated capacitor alarm
Check the capacitor temperature (C6 parameter)
The alarm output is activated
4. To confirm, press the key briefly or refrain from inputting any data for
15 seconds. The LED indicator light goes off and the appliance completes the settings.
5. Press the key briefly to terminate the procedure early. No changes will be saved.
Set-point operation can also be set with the SP parameter.
NOTE!
If additional parameter settings are necessary, contact technical service.
Alarms
700940 21 / 28
Installation and operation
EN
Alarm Code
Description
Solution
Outcomes
CSd
Compressor locked alarm
Check the capacitor temperature (C7 parameter)
Compressor shuts down
Switch the appliance off and on again: if, when the appliance is switched on again, the capacitor temperature is still higher than the maximum temperature set by the C7 parameter, disconnect the power supply and clean the capacitor
The alarm output is activated
dFd
Defrosting terminated due to time limit exceeded alarm
Check the operation of the compressor probe (d2, d3 and d11 parameters)
Appliance is still operating correctly
Press any key to return to normal display
NOTE!
When the fault that triggered the alarm has been cleared, the appliance
restarts its normal operation. The exception to this is the defrosting alarm
due to a time-out (the 'dFd' alarm code). In this case, the key must be
pressed.
22 / 28 700940
Installation and operation
EN
Code
Description
Solution
Outcomes
Pr1
Room temperature probe error
Check whether it is a PTC or NTC type probe (P0 parameter)
Compressor behaviour depends on C4 and C5 parameters
Check the probe connection to the appliance
Defrost never activates
Check the room temperature (A4 parameter)
The alarm output is activated
Pr2
Compressor probe or capacitor probe error
As described above, applies to compressor or capacitor probe only
If the P4 parameter is set to 1, defrosting continues for the time set by the d3 parameter
If the P4 parameter is set to 1 and the 8d parameter is set to 2 or 3, the appliance operates as if the d8 parameter was set to 0
If the P4 parameter is set to 1 or 2, and the F0 parameter is set to 3 or 4, the appliance operates as if the P4 parameter was set to 2
If the P4 parameter is set to 3, the superheated condenser alarm ('COH' code) never activates
If the P4 parameter is set to 3, the locked compressor alarm ('CSd' code) never activates
The alarm output is activated
Error Messages
700940 23 / 28
Cleaning and Maintenance
EN

6 Cleaning and Maintenance

6.1 Safety Instructions for Cleaning

Before cleaning, disconnect the appliance from the power supply.
Leave the appliance to cool down completely.
Make sure water does not enter the appliance. Do not immerse the appliance in
water or other liquids during cleaning. Do not clean the appliance with a
pressurized water jet.
Do not use any sharp or pointed, nor metal implements (knife, fork, etc.). Sharp
or pointed implements may damage the appliance, and when in contact with live
parts, they may cause electric shock.
For cleaning, do not use any scouring agents that contain solvents nor corrosive
cleaning agents. They may damage the surface.

6.2 Cleaning

1. Clean the appliance regularly.
2. Open the glass pane door.
3. Remove the GN containers with ice cream from the appliance and store them in
the mean time in the freezer.
4. Pull out the GN container support.
5. Clean the GN container bracket thoroughly, using warm water and a soft cloth.
Use a mild cleaning agent when required.
6. Clean the ice cabinet and the glass pane door from the inside with warm water,
using a soft cloth and mild cleaning agent.
7. Wipe cleaned parts and surfaces with a cloth moistened in fresh water.
8. Wipe the appliance housing, the display surface with the grate and the glass
pane door from the outside with a soft, damp cloth.
9. Finally, dry thoroughly all cleaned surfaces.
10. Leave the appliance door open for the appliance to dry completely.
24 / 28 700940
Cleaning and Maintenance
EN
11. Clean the used GN containers thoroughly under warm water with a mild
detergent.
12. Rinse the containers thoroughly with fresh water and dry afterwards.
NOTE!
Clean the GN containers, the ice cabinet on the inside and the GN
container support regularly with a food-grade disinfectant.
13. Check the ventilation openings of the appliance regularly; if necessary, clean
them with a soft brush or a vacuum cleaner.

6.3 Maintenance

Let the appliance to be inspected by professional technician at least once a year or as required.
Ensure that the capacitor fins (visible through the housing vents) are not clogged (e.g. with lint, dust).
It is very important for the correct operation of the housing and energy saving that the capacitor fins are clean.
Cleaning must be carried out by authorised and specialised personnel as follows:
disconnect the plug from the socket; after removing the fixing screws, remove the protective grille and the
housing cover;
– clean the capacitor with a brush, air jet or vacuum cleaner to avoid
damage to the housing;
– re-fit the protective grate and cover with special fixing screws.
700940 25 / 28
Possible Malfunctions
EN
Error
Possible Cause
Solution
Appliance not working (no operating noise)
Incorrectly connected plug
Remove the plug and insert it properly into a socket
Defective mains fuse, socket outlet or mains plug
Check the fuse, socket, plug; check the appliance after plugging into another socket
No power supply
Restore the electric power supply
Cooling temperature too high
Ambient temperature too high
Adjust ambient temperature
Damaged thermostat
Contact the service company
Minimum distance from wall not observed
Maintain minimum distance
Ventilation openings clogged or obstructed
Keep ventilation openings free
Contaminated condenser
Perform maintenance
Excessive ice in the cooling compartment
Initiate defrosting process
Insufficient refrigerant in the system
Contact the service company
Cooling temperature too low
Incorrect settings
Adjust the thermostat well
Lighting does not work
Lighting not on
Switch the lighting on
Damaged bulb
Replace the bulb

7 Possible Malfunctions

Mögliche
The table below contains descriptions of possible causes and solutions to malfunctions or errors during operation of the appliance. When malfunction cannot be removed, contact the technical service.
26 / 28 700940
Possible Malfunctions
EN
Error
Possible Cause
Solution
Water condenses in the cooling compartment and on the glass cover
Extreme operating conditions (e.g., humidity >65%, very high ambient temperatures, direct sunlight or heat sources nearby)
Maintain correct ambient temperatures, ensure sufficient air circulation, do not expose the appliance to direct draughts
Water under and in front of the appliance
Incorrect defrosting or extreme operating conditions (e.g., humidity >65%, very high ambient temperatures) can lead to overflowing of the collection tray.
Ensure ambient conditions with the following values: T=0°C – +40°C and RH of 55%
Remove the excess water. If water accumulates again within the next 48 hours, contact the service company
Check fans and the condenser
Odour formation inside the appliance
Clogged air duct space
Perform cleaning
Lack of ventilation or defective fans
Thermostat / control unit out of order
Replace the thermostat and/or the defective ventilation probe
700940 27 / 28
EN
Error
Possible Cause
Solution
Compressor does not work or switches on only briefly
No power supply
Supply power
Temperature set too high: if the set temperature is higher than the temperature in the cooling compartment, the compressor does not start
Set the correct temperature
Capacitor is clogged
Clean the condenser
Fan stalls
Contact the service company
Ambient temperature too high
Ensure optimum ambient temperature
Maximum pressure switch activated (if equipped)
Contact the service company
Electric appliances are marked with this symbol. Electrical appliances must be disposed of and recycled in a correct and environmentally friendly manner. You must not dispose of electric appliances with household waste. Disconnect the appliance from the power supply and remove power cord from the appliance.

8 Disposal

Electrical Appliance
Disposal
Electrical appliances should be returned to designated collection points.
Coolant
The propellant used in the appliance is flammable. It should be utilised pursuant to national regulations in force.
28 / 28 700940