Bartscher 295.9081, 295.9001 Instruction Manual For Installation, Maintenance And Use

Installations-Wartungs und gebrauchs handbuch
Gasbeheizte Kochkessel S.900
01.08.00
pagina
32
INSTRUCTION MANUAL
FOR INSTALLATION,
MAINTENANCE
AND USE
GAS KETTLES
Serie 900
Cat. II
2H3+
- 0085
01.08.00 – GB-
295.9081
295.9001
Installations-Wartungs und gebrauchs handbuch
Gasbeheizte Kochkessel S.900
01.08.00
pagina
33
INDEX
Part 1: General reminders and notes
1.1.
General reminders
34
1.2.
Technical data
35
1.3.
Construction
37
1.4.
Laws, technical prescriptions and directives
38
1.5.
Special requirements for the installation site
38
Part 2: Positioning, installation and maintenance
2.1.
Positioning
38
2.2.
Installation
39
2.2.1.
Connection to waterworks
39
2.2.2.
Gas connection procedures
39
2.3.
Checking the operation of the gas system
39
2.3.1.
Control of the gas inlet pressure
40
2.3.2.
Control of primary air flow
40
2.4.
Commissioning and testing
40
2.5.
Conversion to other types of gas
40
2.5.1.
Replacement of injectors for main burners
41
2.5.2.
Replacement of injectors for pilot burner
41
2.5.3.
Minimum output adjustment
41
2.6.
Maintenance of the appliance
41
2.6.1.
Possible failures and their elimination
42
Part 3: Use and cleaning
3.1.
Warnings and hints for user
42
3.2.
Instructions for use
43
3.2.1.
Filling the jacket
43
3.2.4.
Switch on, start of cooking and switch off
43
3.3.
Cleaning and care of the appliance
44
3.3.1.
Daily cleaning
44
3.4.
Special procedures in case of long inactivity
44
3.5.
Special procedures in case of failures
44
3.6.
How to proceed, if …
45
Installations-Wartungs und gebrauchs handbuch
Gasbeheizte Kochkessel S.900
01.08.00
pagina
34
Part 4: Figures and details
4.1.
Size of appliance and position of connections
75
4.2.
Measuring the inlet pressure
76
4.3.
Gas cock
77
4.4.
Pilot burner
78
4.5.
Main burner
78
4.6.
Primary air regulation
79
4.7.
Controls
80
Installations-Wartungs und gebrauchs handbuch
Gasbeheizte Kochkessel S.900
01.08.00
pagina
35
1.1. GENERAL REMINDERS
Read the warnings contained in this manual carefully as they provide important information concerning
safety during the installation, use and maintenance of the appliance.
Keep these instructions carefully!
Only personnel trained for its specific use should use the equipment.
Keep the appliance under control during use.
The appliance should be used only for the purpose for which it has been specifically designed; other uses
are improper and hence dangerous.
During operation surfaces can become hot and require special operation.
Unplug the appliance in case of failures or improper operation.
Apply exclusively to a service centre for repairs or maintenance.
All important information about the appliance required for technical service is contained in the technical
data plate (see figure “Size of appliance and position of connections”).
In the event of technical assistance being required, the trouble must be described in as much detail as
possible, so that a service technician will be able to understand the nature of the problem.
Gloves should be worn to protect the hands during installation and maintenance operations.
Warning! : Follow the fire prevention regulations very carefully.
Installations-Wartungs und gebrauchs handbuch
Gasbeheizte Kochkessel S.900
01.08.00
pagina
36
1.2. TECNICAL DATA
Table 1 – General data
Model
Type of heating:
Vat usable volume: I
Pressure in the vat: bar
Jacket pressure: bar
2959081
Indirect
100
--
0,5
2959001
Indirect
135
--
0,5
Table 2 – Sizes (see figure “Size of appliance and position of connections”)
Specifications
Models
Description
Unit of measurement
Width (A)
mm
900
Depth (B)
mm
900
Height (C)
mm
900
Vat diameter
mm
600
Table 3 – General water data
Specifications
Models
Description
Unit of
measurement
Cold water connection
mm
10
Hot water connection
mm
10
Water pressure
kPa
50 – 300
Table 4 – Minimum output setting
G 20 – 20 mbar
2,5 mbar
G 30 – 28-30/37 mbar
3 mbar
Table 5 – Gas data
Installations-Wartungs und gebrauchs handbuch
Gasbeheizte Kochkessel S.900
01.08.00
pagina
37
Description
Lower calorific value
H
i
Rated heating power
kW
21
Minimum power
kW
7
Gas connection
R”
½”
Consumption
G20 – 2H
m3/h
2,22
kWh/m3 9,45
G30 – 3+
Kg/h
1,65
kWh/kg 12,68
Nozzles diameter in
1/100 mm
G20
20 mbar Pilot
40
Maximum
3 X 205
Minimum
ADJUST.
G30
28-30/37 mbar Pilot
20
Maximum
3 X 135
Minimum
ADJUST.
Primary air
distance
G20
mm
30
G30
Table 6 – Gas inlet pressure
Table 6a Nominal main pressure for the different
types of gas
Gas family 2 – Natural
20 mbar
Gas family 3 –LPG
28-30/36 mbar
Table 6b Operation permissible if pressure is in the
range:
Gas family 2 – Natural
da 16 a 25 mbar
Gas family 3 –LPG
da 20/25 a 35/45 mbar
Table 6c Operation non permissible if pressure is lower than:
Gas family 2 – Natural
16 mbar
Gas family 3 –LPG
20/25 mbar
Table 6d Operation non permissible if pressure is
higher than:
Gas family 2 – Natural
25 mbar
Gas family 3 –LPG
35/45mbar
Installations-Wartungs und gebrauchs handbuch
Gasbeheizte Kochkessel S.900
01.08.00
pagina
38
1.3. CONSTRUCTION
Main structure in steel with 4 adjustable height feet.
Panels in stainless steel AISI 304, thickness 10-12/10.
Cooking vat in stainless steel AISI 316, thickness 20/10.
Lid in stainless steel, hinged and spring balanced in all opening positions.
Chrome-plated brass drainage tap.
Vat heating controlled by means of high efficiency stainless steel tubular burners resistant to mechanical
and thermal stress.
The gas supplied to the burner is adjusted by a cock.
The appliance has a pilot burner with fixed injector, besides piezoelectric ignition.
The safety of the appliance is ensured by a thermocouple that cuts off the gas flow if the pilot burner
should turn off for any reason.
The cold water connection is 10 mm.
The hot water connection is 10 mm.
The appliance is equipped with a mixer tap.
1.3.1. SPECIAL FEATURES ONLY FOR INDIRECT KETTLES
Stainless steel cooking vat and chamber.
To ensure safe operation, the appliance is equipped with the following devices:
Steam safety valve set at 0.5 bar; Pressure gauge for steam pressure reading; Jacket steam trap; Steam pressure switch set at 0.5 bar; Jacket water supply with level control by means of taps.
Safety thermostat to interrupt operation automatically in case of failures.
Installations-Wartungs und gebrauchs handbuch
Gasbeheizte Kochkessel S.900
01.08.00
pagina
39
1.4. LAWS, TECHNICAL PRESCRIPTIONS AND DIRECTIVES
When installing the appliance it is necessary to follow and comply with the following regulations:
current regulations on the matter;
any hygienic-sanitary regulations concerning cooking environments;
municipal and/or territorial building regulations and fire prevention prescriptions;
current accident prevention guidelines;
standards for the use of combustible gas;
standards for gas-fired systems utilizing on-tap or liquid petroleum gas;
standards relating to gas-fired cooking appliances and similar equipment used large-scale catering.
Safety requirements;
standards relating to gas systems for appliances used in professional kitchens and communal facilities;
the regulations of the gas supply company or agency;
electricity board regulations concerning safety;
the regulations of the electrical power supply company or agency;
any other local prescriptions.
1.5. SPECIAL REQUIREMENTS FOR THE INSTALLATION SITE
The appliance belongs to the installation class A1 (no direct connection of a chimney of flue exhaust
system is required), so it is very important for the environment in which it is installed to be well-aired and provided with all the safety openings prescribed for its power.
In addition, it is good policy to locate the appliance under an extractor hood so that cooking vapours can
be removed rapidly and continuously.
The gas supply system must be equipped with a rapid on off tap approved for the purpose.
This appliance requires two water connections: one for hot and one for cold water. Each line must be
fitted with an on-off valve.
Warning! : The shutoff valves must both be located near to the appliance, within easy reach for
the user.
2.1. POSTIONING
Remove all the packaging and check that the appliance is in perfect conditions. In case of visible
damage, do not connect the appliance and notify the sales point immediately.
Remove the PVC protection from the panels.
Dispose of packaging according to regulations. Generally material is divided according to composition
and should be delivered to the waste disposal service.
Maintain a distance of 5 cm between the back (chimney) of the appliance and the wall. There are no
particular prescriptions regarding side distances from other appliances or walls, however it is advisable to leave enough space in case of maintenance and/or repairs. It is advisable to fit a suitable heat insulation if the appliance is in direct contact with inflammable walls.
The appliance must stand level. Small differences in level can be eliminated by screwing or unscrewing
the adjustable feet: A significantly uneven or sloping stance can affect the operation of the appliance adversely.
Loading...