Bartscher 2800081 User Manual [ru]

Instruction manual for installation, maintenance and use
Gas Kettles PM.G…A
- GB -
1 di 28
INSTRUCTION MANUAL
FOR INSTALLATION,
MAINTENANCE
AND USE
GAS KETTLES
“PM.G…A”
Cat. II
2H3+
- 0085– AU0433
2800021 2800031 2800071 2800081
Instruction manual for installation, maintenance and use
Gas Kettles PM.G…A
- GB -
Page 2 di 28
MANUALE D’ISTRUZIONE
Codice PM.G…A
Storia delle revisioni
Nr.
Revis.
Data di
revisione
Punto
Natura della
correzione
Type of correction
Verbesserungsart
Type de correction
Firma
Visto
05
01.11.2003
Tutti
Modificato libretto
Modify instruction
manual
Veränderfe
Handbuch
Modifiè manuel
d’iinstallation
Budel
06
25.06.2004
Tutti
Modificato libretto
Modify instruction
manual
Veränderfe
Handbuch
Modifiè manuel
d’iinstallation
Budel
07
18.09.07
Pag.20
Cap.3.2.1
Modificato libretto
Modify instruction
manual
Veränderfe
Handbuch
Modifiè manuel
d’iinstallation
G.A.
08
04.03.11
Pag.20
Pag.26-28
Modificato libretto
Modify instruction
manual
Veränderfe
Handbuch
Modifiè manuel
d’iinstallation
G.A.
09
09.04.2013
Tutti
Mod. schema
elettrico
Modify Wiring
Diagram
Veränderfe Elektrischer
Schaltplan
Mod. Schéma
électrique
Cadorin
Instruction manual for installation, maintenance and use
Gas Kettles PM.G…A
- GB -
Page 3 di 28
INDEX
Part 1: General reminders and notes
1.1.
General reminders
5
1.2.
Technical data
6
1.3.
Construction
9
1.3.1.
Special features for pressure kettles (Models PM…… A)
9
1.3.2.
Special features for indirect kettles (Models PM.IG… .)
10
1.4.
Laws, technical prescriptions and directives
10
1.5.
Special requirements for the installation site
10
Part 2: Positioning, installation and maintenance
2.1.
Positioning
11
2.2.
Installation
11
2.2.1.
Connection to waterworks
11
2.2.2.
Gas connection procedures
11
2.3.
Checking the operation of the gas system
12
2.3.1.
Control of the gas inlet pressure
12
2.3.2.
Control of primary air flow
12
2.4.
Commissioning and testing
13
2.5.
Conversion to other types of gas
13
2.5.1.
Replacement of injectors for main burners
13
2.5.2.
Replacement of injectors for pilot burner
13
2.5.3.
Minimum output adjustment
14
2.6.
Maintenance of the appliance
14
2.6.1.
Anode replacing
14
2.6.2.
Possible failures and their elimination
15
Part 3: Use and cleaning
3.1.
Warnings and hints for user
15
3.2.
Instructions for use
16
3.2.1.
Filling the jacket
16
3.2.2.
Use of pressure kettle lid (Models PM…… A)
16
3.2.3.
Switch on, start of cooking and switch off
17
3.3.
Cleaning and care of the appliance
17
3.3.1.
Daily cleaning
17
3.4.
Special procedures in case of long inactivity
18
3.5.
Special procedures in case of failures
18
3.6.
How to proceed, if …
18
Instruction manual for installation, maintenance and use
Gas Kettles PM.G…A
- GB -
Page 4 di 28
Part 4: Figures and details
4.1.
Size of appliance and position of connections
19
4.2.
Measuring the inlet pressure
22
4.3.
Gas cock
23
4.4.
Pilot burner
24
4.5.
Main burner
24
4.6.
Primary air regulation
25
4.7.
Controls
26
4.7.1.
Controls ( MOD. PM1IG200/300/500 PM9IG170/270/370 )
26
4.8.
Relief valve (only pressure kettles)
27
4.9.
Wiring Diagram ( MOD. PM1IG200/300/500 PM9IG170/270/370 )
28
Instruction manual for installation, maintenance and use
Gas Kettles PM.G…A
- GB -
Page 5 di 28
1.1. GENERAL REMINDERS
Read the warnings contained in this manual carefully as they provide important information concerning
safety during the installation, use and maintenance of the appliance.
Keep these instructions carefully!
Only personnel trained for its specific use should use the equipment.
Keep the appliance under control during use.
The appliance should be used only for the purpose for which it has been specifically designed; other
uses are improper and hence dangerous.
During operation surfaces can become hot and require special operation.
Unplug the appliance in case of failures or improper operation.
Apply exclusively to a service centre for repairs or maintenance.
All important information about the appliance required for technical service is contained in the technical
data plate (see figure “Size of appliance and position of connections”).
In the event of technical assistance being required, the trouble must be described in as much detail as
possible, so that a service technician will be able to understand the nature of the problem.
Gloves should be worn to protect the hands during installation and maintenance operations.
Warning! : Follow the fire prevention regulations very carefully.
Instruction manual for installation, maintenance and use
Gas Kettles PM.G…A
- GB -
Page 6 di 28
1.2. TECNICAL DATA
Table 1 – General data Note: Models with "A" as end letter = pressure kettle
Model
Type of heating:
Vat usable volume: I
Pressure in the vat: bar
Jacket pressure: bar PM8DG100
Direct
100
--
--
PM9DG100
Direct
100
--
--
PM8DG100 A
Direct
100
0,05
--
PM9DG100 A
Direct
100
0,05
--
PM8IG100
Indirect
100
--
0,5
PM9IG100
Indirect
100
--
0,5
PM8IG100 A
Indirect
100
0,05
0,5
PM9IG100 A
Indirect
100
0,05
0,5
PM8DG150
Direct
140
--
--
PM9DG150
Direct
140
--
--
PM8DG150 A
Direct
140
0,05
--
PM9DG150 A
Direct
140
0,05
--
PM8IG150
Indirect
135
--
0,5
PM9IG150
Indirect
135
--
0,5
PM8IG150 A
Indirect
135
0,05
0,5
PM9IG150 A
Indirect
135
0,05
0,5
PM9DG200
Direct
200
--
--
PM9DG200 A
Direct
200
0,05
--
PM1DG200
Direct
200
--
--
PM1DG200 A
Direct
200
0,05
--
PM1IG200
Indirect
200
--
0,5
PM1IG200 A
Indirect
200
0,05
0,5
PM1DG300
Direct
300
--
--
PM1DG300 A
Direct
300
0,05
--
PM1IG300
Indirect
300
--
0,5
PM1IG 300 A
Indirect
300
0,05
0,5
PM1DG500
Direct
500
--
--
PM1DG500 A
Direct
500
0,05
--
PM1IG500
Indirect
500
--
0,5
PM1IG500 A
Indirect
500
0,05
0,5
PM9DG170GN
Direct
170
--
--
PM9IG170GN
Indirect
170
--
0,5
PM9DG270GN
Direct
270
--
--
PM9IG270GN
Indirect
270
--
0,5
PM9DG370GN
Direct
370
--
--
PM9IG370GN
Indirect
370
--
0,5
Instruction manual for installation, maintenance and use
Gas Kettles PM.G…A
- GB -
Page 7 di 28
Table 2 – Sizes (see figure “Size of appliance and position of connections”)
Specifications
Models
Description
Unit of
measure
ment
PM8…
PM9…
PM9DG200
PM1.G200
PM1.G300
PM1.G500
Width (A)
mm
800
900
900
1000
1150
1150
Depth (B)
mm
900
900
1150
1300
1300
Height (C)
mm
900
950
900
900
1050
Vat diameter
mm
600
600
750
900
900
Specifications
Models
Description
Unit of
measurement
PM9.G170GN
PM9.G270GN
PM9.G370GN
Width (A)
mm
1000
1400
1800
Depth (B)
mm
900
900
900
Height (C)
mm
900
900
900
Vat diameter
mm
700X550
1100X550
1500X550
Table – Electrical data
Description
Unit of measurement
PM1IG200 / 300 / 500
PM9IG170/ 270/ 370GN
Power
W
200
Voltage/Input
AC 230 V / 60 Hz
Table 3 – General water data
Specifications
Models
Description
Unit of
measurement
PM8…. .
PM9…. .
PM9DG200
PM1.G200 / 300 / 500
PM9…GN
Cold water connection
mm
10
½”
Hot water connection
mm
10
½”
Water pressure
kPa
50 – 300
Table 4 – Minimum output setting
PM8… ./PM9…. .
PM1.G200
PM1.G300
PM1.G500
G 20 – 20 mbar
2,5 mbar
8,6 mbar
5,6 mbar
5 mbar
G 30 – 28-30/37 mbar
3 mbar
12 mbar
8,5 mbar
7,25 mbar
PM9.G170GN
PM9.G270GN
PM9.G370GN
G 20 – 20 mbar
7,5 mbar
4 mbar
3,5 mbar
G 30 – 28-30/37 mbar
11,6 mbar
5,5 mbar
10,5 mbar
Instruction manual for installation, maintenance and use
Gas Kettles PM.G…A
- GB -
Page 8 di 28
Table 5 – Gas data
Description
PM8…. . PM9…. .
PM9DG200
PM1.G200
PM1.G300
PM1.G500
Lower
calorific
value
H
i
Rated heating power
kW
21
32
34.5
48
58
Minimum power
kW
7
15
22.5
26.5
Gas connection
R”
½”
½”
½”
½”
½”
Consumption G20 – 2H
m3/h
2,22
3,38
3,65
5,07
6,1
kWh/m3
9,45
G30 – 3+
Kg/h
1,65
2,52
2,72
3,78
4,57
kWh/kg
12,68
Nozzles diameter in
1/100 mm
G20
20 mbar Pilot
40
40
40
40
40
Maximum
3 X 205
4 X 225
4 X 225
4 X 280
4 X 310
Minimum
ADJUST.
ADJUST.
ADJUST.
ADJUST.
ADJUST.
G30
28-30/37 mbar
Pilot
20
25
25
25
25
Maximum
3 X 135
4 X 145
4 X 150
4 X 185
4 X 195
Minimum
ADJUST.
ADJUST.
ADJUST.
ADJUST.
ADJUST.
Primary air
distance
G20
mm
30
23
30
10
30
G30
OPEN
OPEN
OPEN
Description
PM9.G170GN
PM9.G270GN
PM9.G370GN
Lower calorific value
H
i
Rated heating power
kW
30
44
49
Minimum power
kW
17,8
20
24
Gas connection
R”
½”
½”
½”
Consumption
G20 –
2H
m3/h
3,17
4,65
5,18
kWh/m3 9,45
G30 –
3+
Kg/h
2,36
3,47
3,86
kWh/kg 12,68
Nozzles diameter in 1/100
mm
G20
20 mbar
Pilot
40
40
40
Maximu m
6 X 175
10 X 170
14 x 170
Minimum
ADJUST.
ADJUST.
ADJUST.
G30
28­30/37 mbar
Pilot
25
25
25
Maximu m
6 X 115
10 X 110
14 x 110
Minimum
ADJUST.
ADJUST.
ADJUST.
Primary air
distance
G20
mm
1
10
1
G30
25
18
18
Instruction manual for installation, maintenance and use
Gas Kettles PM.G…A
- GB -
Page 9 di 28
Table 6 – Gas inlet pressure
Table 6a Nominal main pressure for the different
types of gas
Gas family 2 – Natural
20 mbar
Gas family 3 –LPG
28-30/37 mbar
Table 6b Operation permissible if pressure is in the
range:
Gas family 2 – Natural
da 17 a 25 mbar
Gas family 3 –LPG
da 20/25 a 35/45 mbar
Table 6c Operation non permissible if pressure is lower than:
Gas family 2 – Natural
17 mbar
Gas family 3 –LPG
20/25 mbar
Table 6d Operation non permissible if pressure is
higher than:
Gas family 2 – Natural
25 mbar
Gas family 3 –LPG
35/45mbar
1.3. CONSTRUCTION
Main structure in steel with 4 adjustable height feet.
Panels in stainless steel AISI 304, thickness 10-12/10.
Cooking vat in stainless steel AISI 316, thickness 20/10.
Lid in stainless steel, hinged and spring balanced in all opening positions.
Chrome-plated brass drainage tap.
Vat heating controlled by means of high efficiency stainless steel tubular burners resistant to
mechanical and thermal stress.
The gas supplied to the burner is adjusted by a cock.
The appliance has a pilot burner with fixed injector, besides piezoelectric ignition.
The safety of the appliance is ensured by a thermocouple that cuts off the gas flow if the pilot burner
should turn off for any reason.
The cold/hot water connection is 10 mm. (Mod. 100/150lt.)
The cold/hot water connection is ½”. (Mod. 200/300/500/170/270/370lt.)
The appliance is equipped with a mixer tap.
1.3.1. SPECIAL FEATURES FOR PRESSURE KETTLES (MODELS PM…… A)
Stainless steel lid with heat-resistant silicone gasket.
Hermetically sealed with 4 screw clamps.
The relief valve for the pressure that develops in the cooking chamber is set at 0.05 bar.