RFID Snap On Modul
Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004
Document no. B1-A2Z0-7M0003
Revision 1 / June, 20th 2013
Reservation: Technical data subject to change without notice. Changes, errors and
misprints may not be used as a basis for any claim for damages.
Declaration of Conformity
Certificate of Compliance

RFID Snap On Modul
Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004
1. Basic Safety Instructions 3
1.1 Notes on this manual ..................................................................................................... 3
2. Warnings for Use of Wireless Devices 4
2.1 Radio Frequency Interference Requirements - FCC ..................................................... 4
2.2 Radio Frequency Interference Requirements - Canada ................................................ 5
3. Product Description 6
3.1 Operation ....................................................................................................................... 6
3.1.1 Exclusive Purpose ........................................................................................... 6
3.1.2 Site of Operation.............................................................................................. 7
4. Technical Data 8
4.1 Certification.................................................................................................................... 8
4.2 Characteristics ............................................................................................................... 8
4.2.1 Physically Characteristic .................................................................................. 8
4.2.2 User Environment ............................................................................................ 9
4.2.3 Supported RFID Standards ............................................................................. 9
4.3 External Interface ........................................................................................................ 10
4.4 Product Marking .......................................................................................................... 10
5. Commissioning and Operation 11
5.1 Requirements inside of hazardous location ................................................................. 11
5.2 Composition................................................................................................................. 12
6. Order Number 12
6.1 RFID Snap On module for hazardous location ............................................................ 12
6.2 RFID Snap On Module for industrial environment ....................................................... 12

RFID Snap On Modul
Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004
The user manual is a constituent part of the product. It must be kept in the direct vicinity
of the device and accessible at all times to installation, operating and maintenance
personnel.
It contains important notes, safety instructions and test certificates which are necessary
for perfect functioning when the devices are being operated and handled.
The user manual is written for all people who carry out assembly, installation,
commissioning and maintenance work on the product, whereby the directives and
standards applicable to areas with a gas or dust atmosphere (99/92/EC, EN 60079-17,
EN 60079-19, IEC 60079-17, IEC 60079-19) must be observed when doing such work.
Familiarity with and strict adherence to the safety instructions and warnings in this
manual are essential for safe installation and commissioning. Careful handling and
consistent observation of these instructions can prevent accidents, personal injuries and
damage to property.
The illustrations in these operating instructions serve to make the information and
descriptions more clear. They are not necessarily true to scale and may deviate slightly
from the actual construction of the device.
DANGER indicates a hazardous situation which, if not avoided, will result in death or
serious injury.
WARNING indicates a hazardous situation which, if not avoided, could result in death
or serious injury.
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or
moderate injury.
ATTENTION identifies a potentially damaging situation which, if not avoided, could
damage the equipment or something in its environment.
Important instructions and information on effective, economical and environmentally
compatible handling.
1. Basic Safety Instructions
1.1 Notes on this manual
Please read carefully before commissioning the devices..
Safety instructions and warnings are specially highlighted in this manual and marked by
symbols.

RFID Snap On Modul
Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004
2.2 Radio Frequency Interference Requirements - Canada
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
Radio Transmitters
This device complies with RSS 210 of Industry & Science Canada. Operation is subject to
the following two conditions:
(1) this device may not cause harmful interference and
(2) this device must accept any interference received, including
interference that may cause undesired operation.
Label Marking: The Term "IC:" before the radio certification only signifies that "Industry
Canada" technical specifications were met.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisée aux deux
conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2)
l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même
si le brouillage est susceptible d'en compromettre le fonctionnement.

RFID Snap On Modul
Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004
3. Product Description
Available for:
Industrial Environment
ATEX/IECEx Zone 2 and Zone 22
UL Class I, II, III Division 2
3.1 Operation
3.1.1 Exclusive Purpose
The RFID Snap On Module is a accessory. The modules read and write data on RFID
tags in industrial and hazardous locations.
It is used exclusively in combination with operating devices which satisfy the requirements
for overvoltage category I.

RFID Snap On Modul
Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004
3.1.2 Site of Operation
The RFID Snap On Module type G7-A0Z0-…., has been modified for use in following
environment:
Industrial environment outside of hazardous location
The RFID Snap On Module type G7-A0Z0-…., may not be used in locations of:
Hazardous location
The RFID Snap On Module type B7-A2Z0-…., has been modified for use in following
environment:
ATEX/IECEx Zone 2 and Zone 22
UL Class I Division 2 Groups A, B, C and D
UL Class II Division 2 Groups F and G
UL Class III
The RFID Snap On Module type B7-A2Z0-…., may not be used in locations of:
ATEX/IECEx Zone 0
ATEX/IECEx Zone 1 and Zone 21
UL Class I Division 1
UL Class II Division 1

RFID Snap On Modul
Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004
4. Technical Data
B7-A2Z0-0020
B7-A2Z0-0021
B7-A2Z0-0022
B7-A2Z0-0023
II 3G Ex ic IIC T6 Gc
II 3D Ex ic IIIC T80°C Dc
Class I Division 2 Gruppen A, B, C and D
Class II Division 2 Gruppen F and G
Class III
For industrial environment
G7-A0Z0-0001
G7-A0Z0-0002
G7-A0Z0-0003
G7-A0Z0-0004
Length x width x depth
80 x 61 x 31 mm 3,15 x 2,4 x 1,22 inch
approx. 75 g approx. 0,165 oz
4.1 Certification
4.2 Characteristics
4.2.1 Physically Characteristic

RFID Snap On Modul
Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004
-20 °C up to +50 °C -4 °F up to +122 °F
-40 °C up to +70 °C -40 °F up to +158 °F
outside of hazardous location
5 % up to 95 % (non-condensing)
Protection type (EN 60529)
IP 54 (with adapter plate)
LF Reader
Type: B7-A2Z0-0020
Type: G7-A0Z0-0001
HF Reader
Type: B7-A2Z0-0021
Type: G7-A0Z0-0002
UHF EU und US Reader
Type: B7-A2Z0-0022
Type: B7-A2Z0-0023
Type: G7-A0Z0-0003
Type: G7-A0Z0-0004
ISO 14443 (z.B.
Mifare Ultralight)
4.2.2 User Environment
4.2.3 Supported RFID Standards

RFID Snap On Modul
Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004
Marking for ex proofed Version
Type: B7-A2Z0-…
Marking for Industrial Version
Type: G7-A0Z0-….
Type: B7-A2Z0-0020
Type: G7-A0Z0-0001
Type: B7-A2Z0-0021
Type: G7-A0Z0-0002
Type: B7-A2Z0-0023
Type: G7-A0Z0-0003
Type: B7-A2Z0-0022
Type: G7-A0Z0-0004
4.3 External Interface
Pins on the connector:
+++++
4.4 Product Marking

RFID Snap On Modul
Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004
Avoid electrostatic charge inside of hazardous location.
There is a risk of fatal injury in an explosive atmosphere!
Don’t dry clean or wipe.
Wear suitable clothes and shoes.
Don’t use rubber gloves.
Inproper use is a risk for the explosion protection.
There is a risk of fatal injury in an explosive atmosphere!
The user may not make any alterations to the module.
If a function error or a damage on the enclosure occurs then bring the device with
the module immediately outside of the hazardous location and switch it off.
Not certified accessories are a risk for the explosion protection.
There is a risk of fatal injury in an explosive atmosphere!
Use only original accessories from BARTEC.
Only allowed outside of the hazardous location:
Snap on, release and remove of the module
5. Commissioning and Operation
5.1 Requirements inside of hazardous location
Don’t open it!
Don’t use, change or replace not specified!
Protect the device from impact effects!
Do not expose the equipment to any caustic/aggressive liquids, vapours or mist!
Avoid the effects of moisture!
Avoid the influence of heat that is outside of the specified temperature range!
Snap on of the 10-pin data interface is only permissible outside the hazardous area
and only with devices specified by the manufacturer!

RFID Snap On Modul
Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004
5.2 Composition
6. Order Number
6.1 RFID Snap On module for hazardous location
6.2 RFID Snap On Module for industrial environment

RFID Snap On Modul
Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004
7. Compliance Information Statement
Compliance Information Statement
(Declaration of Conformity Procedure)
Responsible Party:
BARTEC US Corp
Address:
600 Century Plaza Drive
Suite C160
Houston, TX 77073
USA
Telephone:
+ 1 281 214 8542
Type of Equipment:
RFID Snap On Module
Type B7-A2Z0-0020, -0021 and -0022 and
G7-A0Z0-0001, -0002 and -0004
Model Name:
RFID LF Snap On Module FCC ID: TBULFG2
RFID HF Snap On Module FCC ID: TBUHFG2
RFID UHF (US) Snap On Module FCC ID: TBUUHFG2