IMPORTANT! - Read all instructions in this manual before operating or servicing
a pump.
Page 2
General Safety Information
Before installation, read the following
instructions carefully. Failure to
follow instruction and safety
information could cause serious
bodily injury, death and/or property
damage. Each Barmesa product is
carefully inspected to insure proper
performance. Closely following these
instructions will eliminate potential
operating problems, assuring years
of trouble-free service.
DANGER
imminently hazardous situation
which, if not avoided, WILL result in
death or serious injury.
WARNING
an imminenty hazardous situation
which, if not avoided, MAY result in
death or serious injury.
CAUTION
potentially hazardous situation
which, if not avoided, MAY result in
minor or moderate injury.
"Danger" indicates an
"Warning" indicates
"Caution" indicates a
barmesapumps.com
IMPORTANT! - Barmesa Pumps is not
responsible for losses, injury or
death resu lting from fai lure to
observe these safety precautions,
misuse, abuse or misapplication of
pumps or equipment.
A L L R E T U R N E D
P R O D U C T S M U S T B E
CLEANED, SANITIZED, OR
DECONTA M I N AT ED P RIOR TO
SHIPMENT, TO INSURE EMPLOYEES
WILL NOT BE EXPOSED TO HEALTH
HAZA RD S IN HAN DLING S AID
MATERIAL. ALL APPLICABLE LAWS
AND REGULATIONS SHALL APPLY.
WARNING
junc tio n co nn ect ion s must be in
accordance with the National Electric
Code and all applicable state and local
codes. Requirements may vary depending
on usage and location.
Installation, wiring, and
WARNING
se rvicing is to be conducted by
qualified personnel only.
pow er co nnec te d; th e rota ting
impeller can cause serious injury.
may become entangled in moving
parts.
DANGER
before handling or servicing the
p u m p o r a ny accessory i t e m s
associated with or near the pump.
DANGER
human contact with pumped fluid.
DANGER
handling any aspect of the pumping
system. Lock out power and tag.
WARNING
pumps in water over 77º F. Do not
exceed manufacturers recommended
maximum performance, as this could
cause the motor to overheat.
DANGER
shock, burns or death. Never handle
connected power cords with wet
hands. Use appropriate lifting device.
I n s t a l l a t i o n a n d
Keep clear of suction and
discharge openings. Do not
insert fingers in pump with
Always wear eye protection
when working on pumps. Do
not wear loose clothing that
Pumps build up heat
and pressure during
operation. Allow time
fo r p umps t o c ool
T h i s p u mp i s n o t
i n t e n d e d f o r u s e i n
swimming pools or water
installations where there is
Risk of electric shock. To
reduce risk of electric shock,
always disco nnect pump
from power source before
D o n o t u se t h e se
Do not lift, carry or
hang pump by the electrical
c a b l e s . D amage to t h e
electrical cables can cause
WARNING
pumps often handle materials which
could cause illness or disease. Wear
adequate protective clothing when
working on a used pump or piping.
Never enter a basin after it has been
used.
DANGER
burns or death.
DANGER
Electric Code, ANSI/NFPA 70.
WARNING
Code (UP C) s tat es that sew age
systems shall have an audio and visual
alarm that signals a malfunction of the
systems, that are required to reduce
the potencial for property damage.
IMPORTANT! - Prior to installation,
record Model Number, Serial, Amps,
Voltage, Phase and HP from pump
name plate for the future reference.
Also record the Voltage and Current
Readings at Startup:
Model Number: ____________________
Serial: ____________________
Amps:_______ Voltage:_______
Phase:_______ HP:_______
S u mp a n d se w a ge
Failure to permanently
ground the pump, motor and
controls before connecting
to power can cause shock,
These pumps are not to
be i nstal led in l ocati ons
classified as hazardous in
accordance with the National
The Uniform Plumbing
01
Page 3
Specifications & Dimensions
DISCHARGE: 2" NPT, female, vertical.
SPH SLD HNDLG: 2"
LIQUID TEMPERATURE: 104 °F (40 °C) max.
VOLUTE: Cast iron ASTM A-48 class 30.
MOTOR HOUSING: Cast iron ASTM A-48 class 30.
IMPELLER: Vortex. Cast iron ASTM A-48 class 30, dynamically balanced, ISO G6.3.
SHAFT: 416 series stainless steel.
O-RINGS: Square shaped Buna-N.
PAINT: Air dry enamel, water based.
SEAL: Single mechanical, oil filled chamber. Carbon / ceramic / Buna-N, with stainless steel
hardware.
HARDWARE: 300 series stainless steel.
CORD ENTRY: 20 ft of neoprene cord SJTOW 16/3, sealed against moisture.
UPPER BEARING: Ball, single row, oil lubricated, for radial load.
LOWER BEARING: Ball, single row, oil lubricated, for radial and axial loads.
MOTOR: NEMA L, single phase, permanent split capacitor, 115 volts, 60 Hz, 3500 RPM, oil
Upon receiving the pump, it should
be inspected for damage or
shortages. If damage has occurred,
file a claim immediately with the
company that delivered the pump. If
the manual is removed from the
packaging, do not lose or misplace.
Storage
Any product that is stored for a
period longer than six (6) months
from the date of purchase should be
bench tested prior to installation. A
bench test consists of, checking the
impeller to assure it is free turning
and a run test to assure the motor
(and switch if provided) operate
properly. Do not pump out of liquid.
Controls
Manual models require a separate
approved pump control device or
panel for automatic operation. Be
sure the electrical specification of the
barmesapumps.com
control selected properly match the
electrical specifications of the pump.
Submergence
The pump should always be
operated in the submerged
condition. The minimum sump liquid
level should never be less than above
the pump’s volute (See Figure 1).
Liquid Level Control
Typical Discharge Pipe Mounted:
Refer to Figure 2 below which shows
a typical installation of a 1 phase 115
volt pump using a level control
mounted to the discharge piping
with a piggyback plug. The level
control should have adequate
clearance so it cannot hang up in it’s
swing and that the pump is
completely submerged when the
level control is in the "Off" mode. By
adjusting the cord tether the control
level can be changed.
Typical Discharge Pipe Mounted
Level Control
DISCHARGE
VENT
GATE
VALVE
CHECK VALVE
INLET
UNION
Drill ⅛" dia. vent hole
to prevent air locking
Figure 3
Installation
These pumps are recommended for
use in a sump or basin. The sump or
basin shall be sealed and vented in
accordance with local plumbing
codes. This pump is designed to
pump effluent or wastewater,
nonexplosive and noncorrosive
liquids and shall NOT be installed
in locations classified as hazardous
in accordance with the National
Electrical Code (NEC) ANSI/NFPA
70 or Canadian Electric Code
(CEC).The pump should never be
installed in a trench, ditch, or hole
with a dirt bottom. The legs will sink
into the dirt and the suction will
become plugged.
Recommended
Submergence Level
Minimum
Submergence Level
6"
Figure 1
Bottom of Feet
Level Control Basic instructions:
Plug the level control plug into the
GFI receptacle, then plug the pump
into the piggy-back plug (See Figure
3). One cycle of operation should be
observed, so that any potential
problems can be corrected.
It is recommended that the level
control float should be set to insure
that the liquid in the sump never
drops below the top of the motor
housing or a minimum level of 6
inches above the basin floor.
The installation should be at a
sufficient depth to ensure that all
plumbing is below the frost line. If
this is not feasible, remove the check
valve and size the basin to
accommodate the additional
backflow volume.
Discharge Piping
Discharge piping should be as short
as possible and sized no smaller than
the pump discharge. Do not reduce
the discharge pipe size below that
which is provided on the pump.
03
Page 5
Installation & Service
Both a check valve and a shut-off
valve are recommended for each
pump. The check valve is used to
prevent backflow into the sump. The
shut-off valve is used to manually
stop system flow during pump
servicing.
Electrical Connections
Power cable:
The power cable mounted to the
pump must not be modified in any
way. This pump is provided with a 3
wire cord and 3 prong grounded
plug that must be connected into a 3
wire grounded Ground Fault
receptacle. Do not bypass grounding
wires or remove ground prongs from
plug. This pump requires separate,
properly fused and grounded branch
circuit. Use of a ground fault circuit
interrupter (GFCI) is strongly
recommended.
The electrical outlet or panel shall be
within the length limitations of the
barmesapumps.com
pump power cord, and at least 4 feet
above floor level to minimize
possible hazards from flood
conditions. Do Not use an extension
cord.
IF USED with Control Panel - Any
splice between the pump and the
control panel must be made in
accordance with the electric codes. It
is recommended that a junction box,
if used, be mounted outside the
sump or be of at a minimum NEMA 4
construction if located within the wet
well. DO NOT USE THE POWER CABLE TO LIFT PUMP. Always rely
upon a Certified Electrician for
installation.
Overload Protection:
Single Phase - The stator in-winding
overload protector used is referred to
as an inherent overheating protector
and operates on the combined effect
of temperature and current.
This means that the overload
protector will trip out and shut the
pump off if the windings become too
hot, or the load current passing
through them becomes too high.
IMPORTANT! - The overload will then
automatically reset and start the
pump up after the motor cools to a
safe temperature. In the event of an
overload, the source of this condition
should be determined and corrected
immediately.
WARNING
P UM P C Y C LE O R R U N I F A N
OVERLOAD CONDITION OCCURS.
If current through the temperature
sensor exceeds the values listed, an
intermediate control circuit relay
must be used to reduce the current
or the sensor will not work properly.
TEMPERATURE SENSOR ELECTRICAL
VoltsContinuous
110-1203.0030.0
220-2401.5015.0
Wire Size:
If longer power cable is required
consult a qualified electrician for
proper wire size.
D O N OT L E T T H E
RATINGS
Inrush
Amperes
Amperes
Pre-Operation
1.Check Voltage and Phase -
Compare the voltage and phase
information stamped on the
pump name plate.
2.Check Pump Rotation - Improper
motor rotation can result in poor
pump performance and can
damage the motor and/or pump.
Incorrect rotation for Single-Phase
pumps is unlikely. If the rotation is
incorrect contact factory.
3.Name Plate - Record the
information from the pump name
plate to drawing in front of
manual for future reference.
4.Insulation Test - An insulation
(megger) test should be
performed on the motor. Before
the pump is put into service. The
resistance values (ohms) as well
as the voltage (volts) and current
(amps) should be recorded.
5.Pump-Down Test - Be sure pump
has been properly wired, lowered
into the basin, sump or lift station,
check the system by filling with
liquid and allowing the pump to
operate through its pumping
cycle. The time needed to empty
the system, or pump-down time
along with the volume of water,
should be recorded.
Maintenance
No lubrication or maintenance is
required. Perform the following
checks when pump is removed from
operation or when pump
performance deteriorates:
a)Inspect motor chamber for oil
level and contamination.
b)Inspect impeller and body for
excessive build-up or clogging.
c)Inspect motor, bearings and shaft
seal for wear or leakage.
Servicing
Cooling Oil - Anytime the pump is
removed from operation, the cooling
oil in the motor housing should be
checked visually for oil level and
contamination.
To check oil, set unit upright. Remove
pipe plug from housing.
04
Page 6
Service
With a flashlight, visually inspect the
oil in the housing to make sure it is
clean and clear, light amber in color
and free from suspended particles.
Milky white oil indicates the presence
of water. Oil level should be just
above the motor when pump is in
vertical position.
Oil Testing
Ÿ Drain oil into a clean, dry
container by placing pump on it’s
side, remove pipe plug, from
housing.
Ÿ Check oil for contamination using
an oil tester with a range to 30
kilovolts breakdown.
Ÿ If oil is found to be clean and
uncontaminated (measuring
above 15 kV breakdown), refill the
housing.
Ÿ If oil is found to be dirty or
contaminated (or measures below
15 kV breakdown), the pump
must be carefully inspected for
leaks at the shaft seal, cable
barmesapumps.com
assembly, square ring and pipe
plug, before refilling with oil. To
locate the leak, perform a
pressure test.
After leak is repaired, dispose of old
oil properly, and refill with new oil.
Pressure builds up extremely
fast, increase pressure by
"TAPPING" air nozzle. Too
much pressure will damage
seal. DO NOT exceed 10 PSI.
Oil Replacement - Set unit upright
and refill with new cooling oil as per
table below. Fill to just above motor,
but below capacitor as an air space
must remain in the top of the
housing to compensate for oil
expansion.
Apply pipe thread compound to
threads of pipe plug then assemble
to housing.
DO NOToverfill oil.
Overfilling of housing with oil
can create excessive and
dangerous hydraulic pressure
which can destroy the pump
and create a hazard.
3. Clean and examine impeller, for
cracks or breakage and replace if
required. To remove impeller, place a
flat screwdriver in the slot of the end
of the shaft to hold the shaft
stationary while unscrewing.
4. Check v-ring and remove if
damaged.
Power Cord and Motor:
5. Remove pipe plug and drain oil
from housing.
6. Remove gland nut, washer and
nylon housing from motor housing.
Pull cord through and disconnect the
wires from the terminals on power
cord.
7. Remove screws and washers and
lift motor housing and stator from
seal plate.
8. Remove o-ring, replace if damaged.
9. Check motor capacitor with an
Ohm meter by first grounding the
capacitor by placing a screwdriver
across both terminals and then
removing screwdriver. Connect Ohm
meter (set on high scale) to terminals.
If needle moves to infinity (∞) then
drifts back, the capacitor is good. If
needle does not move or moves to
infinity (∞) and does not drift back,
replace capacitor.
10. Inspect motor winding for shorts
and check resistance values. Check
rotor for wear. If rotor or the stator
windings are defective, the complete
motor must be replaced.
Shaft Seal:
11. Remove snap ring from seal plate.
Remove shaft and motor rotor from
seal plate.
12. Remove seal’s rotating member,
spring and retaining ring from seal
plate. Examine all seal parts, if seal
faces show signs of wear, uneven
wear pattern, chips or scratches
replace entire seal. DO NOT
interchange seal components,
replace the entire shaft seal. If
replacing seal, remove stationary by
prying out with flat screwdrive.
Bearings:
13. Examine lower bearing, and
upper bearing, if replacement is
required, remove by using a wheel
puller.
05
Page 7
Service
Reassembly
IMPORTANT! - All parts
must be clean before
reassembly. Handle seal
parts with extreme care. DO NOT
damage lapped surfaces.
Bearings:
1. Press bearings and onto shaft.
Shaft Seal:
2. Clean seal cavity in seal plate and
oil. Press seal’s stationary member
firmly into seal plate, use a seal tool
or pipe. Nothing should come in
contact with the seal face except the
seal tool. Be sure the stationary is in
straight.
3. Place seal’s retaining ring, spring
onto shaft. Lightly oil (Do not use
grease) shaft and inner surface of
bellows.
Power Cord:
8. Check power cord for cracks or
damage and replace if required.
Reconnect motor leads.
9. Place power cord with nylon
housing, ring, washer and gland nut
into housing and tighten gland nut
to 17.5 ft/lbs.
Impeller, V-ring and Volute:
10. Position v-ring into seal plate until
seated.
11. Clean the threads with thread
locking compound cleaner. Apply
removable Loctite® 242 or equivalent
to shaft threads. Screw impeller onto
the shaft hand tight while using a
screwdriver in the slot at the end of
the shaft to hold it stationary. Rotate
impeller to check for binding.
12. Position gasket on volute flange
barmesapumps.com
4. With lapped surface of seal’s
rotating member facing outward,
slide over shaft using a seal tool,
being carefull not to damage seal
face. Make sure spring is seated in
retaining ring and spring is lined up
on rotating member and not cocked
or resting on bellows tail.
Motor:
5. Slide rotor/shaft with bearings and
seal parts into seal plate until bearing
seats into seal plate. Install snap ring
into seal plate.
6. Lower housing while stringing
motor leads through the cord entry
bore, with motor stator onto seal
plate.
and position impeller and motor
housing assembly on volute.
13. Place screws into volute and
torque to 11 ft/lbs. Check for free
rotation of impeller.
14. Refill with cooling oil.
7. Place screws with washers through
housing into seal plate and torque to
60 in/lbs.
06
Page 8
2SEV512
Repair Parts
barmesapumps.com
For Repair Part Please supply: Model Number and Serial as shown on
Name Plate, and Part Description and Part Number as shown on Parts List.
16 Casing1HT20
17 Handle1304+NBR40
18 Hex bolt 1/4" - 20UNCx132304
19 Name plate1304
20 Nail for name plate 2x64Cu
21 Hex socket pipe stropper 1/4" - 18 NPT1304
22 Vortex shell gasket1NBR41
23 Hex socket cap head screws 1/4" - 20UNCx182304
24 O-ring Ø5.25" x 0.25"1NBR40
25 Lengthen bolt M4x1002Q235A
26 Bearing 6200 Z3127 Wave washer Ø1.125"165Mn
28 Cable guard1NBR40
29 Float switch130 Clamp12Cr13+NBR40
31 Cross recessed pan head screw
#10 - 31UNFx121304
0
For Repair Part Please supply: Model Number and Serial as shown on
Name Plate, and Part Description and Part Number as shown on Parts List.
08
Page 10
Troubleshooting Chart
Risk of electric shock. Always disconnect the pump from the power source before handling inspections or repairs.
SymptomPossible Cause(s)Corrective Action
1. Poor electrical connection, blown fuse, tripped
breaker or other interruption of power;
improper power supply
2. Motor or switch inoperative (go to manual
Pump will not run
Pump will not turn off
Pump hums but doesn’t run
Pump delivers insufficient capacity
barmesapumps.com
Pump cycles too frequently or runs periodically
when f ixtures are not in use
Pump shuts of f and turns on independent of
switch, (trips thermal overload protector).
CAUTION! Pump may start unexpectedly.
Disconnect power supply.
Pump operates noisily or vibrates excessively
NOTE: Barmesa Pumps assumes no responsibility for damage or injury due to disassembly in the field. Disassembly of the pumps or supplied accessories other
than at Barmesa Pumps or its authorized service centers, automatically voids warranty.
operation)
2a. Float movement restricted
2b. Switch will not activate pump or is defective
2c. Defective motor
3. Insuffi cient liquid level
2a. Float movement restricted
2b. Switch will not activate pump or is defective
4. Excessive inflow or pump not properly sized for
application
9. Pump may be air locked causing pump not to flow
14. H-O-A switch on panel is in "HAND" position
1. Incorrect low voltage
8. Impeller jammed or loose on shaft, or inlet
plugged
1. Incorrect low voltage
4. Excessive inflow or pump not properly sized for
application
5. Discharge restricted
6. Check valve partially closed or installed backwards
7. Shut-off valve closed
8. Impeller jammed or loose on shaft, or inlet
plugged
9. Pump may be air locked causing pump not to flow
10. Piping fixtures leaking or discharge before the
nozzle
6. Check valve partially closed or installed backwards
11. Fixtures are leaking
15. Ground water entering basin
1. Incorrect low voltage
4. Excessive inflow or pump not properly sized for
application
8. Impeller jammed or loose on shaft, or inlet
plugged
12. Excessive water temperature (internal
protection only)
2c. Worn bearings, motor shaft bent
5. Debris in impeller cavity or broken impeller
10. Pump running backwards
13. Piping attachments to building structure too
loose or rigid
1. Check all electrical connections for security.
Have electrician measure current in motor leads,
if current is within ± 20% of locked rotor Amps,
impeller is probably locked. If current is 0,
overload may be tripped. Remove power, allow
pump to cool, then re-check current.
2a. Reposition pump or clean basin as required to
provide adaquate clearance for float
2b. Disconnect level control. Set ohmmeter for a
low rang, such as 100 ohms full scale and
connect to level control leads. Actuate level
control manually and check to see that
ohmmeter shows zero ohms for closed switch
and full scale for open switch. (Float Switch)
2c. Check winding insulation (Megger Test) and
winding resistance. If check is outside of range,
dry and re-check. If still defective, replace per
service instructions.
3. Make sure liquid level is above the pump
4. Re-check all sizing calculations to determine
proper pump size.
5. Check discharge line for restrictions, including
ice if line passes through or into cold areas.
6. Remove and examine check valve for proper
installation and freedom of operation
7. Open valve
8. Check impeller for freedom of operation,
security and condition. Clean impeller cavity
and inlet of any obstruction
9. Loosen union slightly to allow trapped air to
escape. Verify that turn-off level of switch is set
so that the suction is always flooded. Clean vent
hole
10. Check rotation. If power supply is three phase,
reverse any two of three power supply leads to
ensure proper impeller rotation
11. Repair fixtures as required to eliminate leakage
12. Check pump temperature limits and fluid
temperature
13. Replace portion of discharge pipe with flexible
connector or tighten existing piping.
14. Turn to automatic position
15. Check for leaks around basin inlet and outlets
09