Barmesa Pumps 2SEV512 Installation, Operation & Maintenance Manual

Page 1
2SEV512
0.5 @ 3500 RPM
Installation, Operation &
Maintenance Manual
Submersible Sewage Pumps
barmesapumps.com
IMPORTANT! - Read all instructions in this manual before operating or servicing a pump.
Page 2
General Safety Information
Before installation, read the following instructions carefully. Failure to follow instruction and safety information could cause serious bodily injury, death and/or property damage. Each Barmesa product is carefully inspected to insure proper performance. Closely following these instructions will eliminate potential operating problems, assuring years of trouble-free service.
DANGER
imminently hazardous situation which, if not avoided, WILL result in death or serious injury.
WARNING
an imminenty hazardous situation which, if not avoided, MAY result in death or serious injury.
CAUTION
potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury.
"Danger" indicates an
"Warning" indicates
"Caution" indicates a
barmesapumps.com
IMPORTANT! - Barmesa Pumps is not responsible for losses, injury or death resu lting from fai lure to observe these safety precautions, misuse, abuse or misapplication of pumps or equipment.
A L L R E T U R N E D P R O D U C T S M U S T B E
CLEANED, SANITIZED, OR DECONTA M I N AT ED P RIOR TO SHIPMENT, TO INSURE EMPLOYEES WILL NOT BE EXPOSED TO HEALTH HAZA RD S IN HAN DLING S AID MATERIAL. ALL APPLICABLE LAWS AND REGULATIONS SHALL APPLY.
WARNING
junc tio n co nn ect ion s must be in accordance with the National Electric Code and all applicable state and local codes. Requirements may vary depending on usage and location.
Installation, wiring, and
WARNING
se rvicing is to be conducted by qualified personnel only.
pow er co nnec te d; th e rota ting impeller can cause serious injury.
may become entangled in moving parts.
DANGER
before handling or servicing the p u m p o r a ny accessory i t e m s associated with or near the pump.
DANGER
human contact with pumped fluid.
DANGER
handling any aspect of the pumping system. Lock out power and tag.
WARNING
pumps in water over 77º F. Do not exceed manufacturers recommended maximum performance, as this could cause the motor to overheat.
DANGER
shock, burns or death. Never handle connected power cords with wet hands. Use appropriate lifting device.
I n s t a l l a t i o n a n d
Keep clear of suction and discharge openings. Do not insert fingers in pump with
Always wear eye protection when working on pumps. Do not wear loose clothing that
Pumps build up heat and pressure during operation. Allow time fo r p umps t o c ool
T h i s p u mp i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is
Risk of electric shock. To reduce risk of electric shock, always disco nnect pump from power source before
D o n o t u se t h e se
Do not lift, carry or
hang pump by the electrical c a b l e s . D amage to t h e electrical cables can cause
WARNING
pumps often handle materials which could cause illness or disease. Wear adequate protective clothing when working on a used pump or piping. Never enter a basin after it has been used.
DANGER
burns or death.
DANGER
Electric Code, ANSI/NFPA 70.
WARNING
Code (UP C) s tat es that sew age systems shall have an audio and visual alarm that signals a malfunction of the systems, that are required to reduce the potencial for property damage.
IMPORTANT! - Prior to installation, record Model Number, Serial, Amps, Voltage, Phase and HP from pump name plate for the future reference. Also record the Voltage and Current Readings at Startup:
Model Number: ____________________
Serial: ____________________
Amps:_______ Voltage:_______
Phase:_______ HP:_______
S u mp a n d se w a ge
Failure to permanently ground the pump, motor and controls before connecting to power can cause shock,
These pumps are not to be i nstal led in l ocati ons classified as hazardous in accordance with the National
The Uniform Plumbing
01
Page 3
Specifications & Dimensions
DISCHARGE: 2" NPT, female, vertical.
SPH SLD HNDLG: 2"
LIQUID TEMPERATURE: 104 °F (40 °C) max.
VOLUTE: Cast iron ASTM A-48 class 30.
MOTOR HOUSING: Cast iron ASTM A-48 class 30.
IMPELLER: Vortex. Cast iron ASTM A-48 class 30, dynamically balanced, ISO G6.3.
SHAFT: 416 series stainless steel.
O-RINGS: Square shaped Buna-N.
PAINT: Air dry enamel, water based.
SEAL: Single mechanical, oil filled chamber. Carbon / ceramic / Buna-N, with stainless steel
hardware.
HARDWARE: 300 series stainless steel.
CORD ENTRY: 20 ft of neoprene cord SJTOW 16/3, sealed against moisture.
UPPER BEARING: Ball, single row, oil lubricated, for radial load.
LOWER BEARING: Ball, single row, oil lubricated, for radial and axial loads.
MOTOR: NEMA L, single phase, permanent split capacitor, 115 volts, 60 Hz, 3500 RPM, oil
filled, with overload protection in motor.
OPTIONAL EQUIPMENT: Additional cord, slide rail coupling (SRC-2).
MODEL PART No. HP VOLTS PHASE
barmesapumps.com
2SEV512 62180405 0.5 115 1 3500 10.2 16 16/3 SJTOW 51
2SEV512A 62180406 0.5 115 1 3500 10.2 16 16/3 SJTOW 53
2SEV512VF 62180407 0.5 115 1 3500 10.2 16 16/3 SJTOW 53
A = Automatic Float Switch, VF = Automatic Vertical Float Switch.
RPM
(Nominal)
15"15"15"
6.45"6.45"6.45"
MAX
AMPS
LOCKED
ROTOR AMPS
3.23"3.23"3.23"
CORD
4.82"4.82"4.82"
SIZE
CORD
TYPE
WEIGHT
(pounds)
2" NPT2" NPT2" NPT
1.22"1.22"1.22"
4.47"4.47"4.47"
9.43"9.43"9.43"
02
Page 4
Receiving & Installation
Receiving inspection
Upon receiving the pump, it should be inspected for damage or shortages. If damage has occurred, file a claim immediately with the company that delivered the pump. If the manual is removed from the packaging, do not lose or misplace.
Storage
Any product that is stored for a period longer than six (6) months from the date of purchase should be bench tested prior to installation. A bench test consists of, checking the impeller to assure it is free turning and a run test to assure the motor (and switch if provided) operate properly. Do not pump out of liquid.
Controls
Manual models require a separate approved pump control device or panel for automatic operation. Be sure the electrical specification of the
barmesapumps.com
control selected properly match the electrical specifications of the pump.
Submergence
The pump should always be operated in the submerged condition. The minimum sump liquid level should never be less than above the pump’s volute (See Figure 1).
Liquid Level Control
Typical Discharge Pipe Mounted:
Refer to Figure 2 below which shows a typical installation of a 1 phase 115 volt pump using a level control mounted to the discharge piping with a piggyback plug. The level control should have adequate clearance so it cannot hang up in it’s swing and that the pump is completely submerged when the level control is in the "Off" mode. By adjusting the cord tether the control level can be changed.
Typical Discharge Pipe Mounted
Level Control
DISCHARGE
VENT
GATE VALVE
CHECK VALVE
INLET
UNION
Drill ⅛" dia. vent hole to prevent air locking
Figure 3
Installation
These pumps are recommended for use in a sump or basin. The sump or basin shall be sealed and vented in accordance with local plumbing codes. This pump is designed to
pump effluent or wastewater, nonexplosive and noncorrosive liquids and shall NOT be installed in locations classified as hazardous in accordance with the National Electrical Code (NEC) ANSI/NFPA 70 or Canadian Electric Code (CEC).The pump should never be
installed in a trench, ditch, or hole with a dirt bottom. The legs will sink into the dirt and the suction will
become plugged.
Recommended Submergence Level
Minimum Submergence Level
6"
Figure 1
Bottom of Feet
Level Control Basic instructions:
Plug the level control plug into the GFI receptacle, then plug the pump into the piggy-back plug (See Figure
3). One cycle of operation should be observed, so that any potential problems can be corrected.
It is recommended that the level control float should be set to insure that the liquid in the sump never drops below the top of the motor housing or a minimum level of 6 inches above the basin floor.
The installation should be at a sufficient depth to ensure that all plumbing is below the frost line. If this is not feasible, remove the check valve and size the basin to accommodate the additional backflow volume.
Discharge Piping
Discharge piping should be as short as possible and sized no smaller than the pump discharge. Do not reduce
the discharge pipe size below that which is provided on the pump.
03
Page 5
Installation & Service
Both a check valve and a shut-off valve are recommended for each pump. The check valve is used to prevent backflow into the sump. The shut-off valve is used to manually stop system flow during pump servicing.
Electrical Connections
Power cable:
The power cable mounted to the pump must not be modified in any way. This pump is provided with a 3 wire cord and 3 prong grounded plug that must be connected into a 3 wire grounded Ground Fault receptacle. Do not bypass grounding wires or remove ground prongs from plug. This pump requires separate, properly fused and grounded branch circuit. Use of a ground fault circuit interrupter (GFCI) is strongly recommended.
The electrical outlet or panel shall be within the length limitations of the
barmesapumps.com
pump power cord, and at least 4 feet above floor level to minimize possible hazards from flood conditions. Do Not use an extension cord.
IF USED with Control Panel - Any splice between the pump and the control panel must be made in accordance with the electric codes. It is recommended that a junction box, if used, be mounted outside the sump or be of at a minimum NEMA 4 construction if located within the wet well. DO NOT USE THE POWER CABLE TO LIFT PUMP. Always rely upon a Certified Electrician for installation.
Overload Protection:
Single Phase - The stator in-winding
overload protector used is referred to as an inherent overheating protector and operates on the combined effect of temperature and current.
This means that the overload protector will trip out and shut the pump off if the windings become too hot, or the load current passing through them becomes too high.
IMPORTANT! - The overload will then automatically reset and start the pump up after the motor cools to a safe temperature. In the event of an overload, the source of this condition should be determined and corrected immediately.
WARNING
P UM P C Y C LE O R R U N I F A N OVERLOAD CONDITION OCCURS.
If current through the temperature sensor exceeds the values listed, an intermediate control circuit relay must be used to reduce the current or the sensor will not work properly.
TEMPERATURE SENSOR ELECTRICAL
Volts Continuous
110-120 3.00 30.0
220-240 1.50 15.0
Wire Size:
If longer power cable is required consult a qualified electrician for proper wire size.
D O N OT L E T T H E
RATINGS
Inrush
Amperes
Amperes
Pre-Operation
1.Check Voltage and Phase -
Compare the voltage and phase information stamped on the pump name plate.
2.Check Pump Rotation - Improper
motor rotation can result in poor pump performance and can damage the motor and/or pump. Incorrect rotation for Single-Phase pumps is unlikely. If the rotation is incorrect contact factory.
3.Name Plate - Record the
information from the pump name plate to drawing in front of manual for future reference.
4.Insulation Test - An insulation
(megger) test should be performed on the motor. Before the pump is put into service. The resistance values (ohms) as well as the voltage (volts) and current (amps) should be recorded.
5.Pump-Down Test - Be sure pump
has been properly wired, lowered into the basin, sump or lift station, check the system by filling with liquid and allowing the pump to operate through its pumping cycle. The time needed to empty the system, or pump-down time along with the volume of water, should be recorded.
Maintenance
No lubrication or maintenance is required. Perform the following checks when pump is removed from operation or when pump performance deteriorates:
a)Inspect motor chamber for oil
level and contamination.
b)Inspect impeller and body for
excessive build-up or clogging.
c)Inspect motor, bearings and shaft
seal for wear or leakage.
Servicing
Cooling Oil - Anytime the pump is
removed from operation, the cooling oil in the motor housing should be checked visually for oil level and contamination.
To check oil, set unit upright. Remove pipe plug from housing.
04
Page 6
Service
With a flashlight, visually inspect the oil in the housing to make sure it is clean and clear, light amber in color and free from suspended particles. Milky white oil indicates the presence of water. Oil level should be just above the motor when pump is in vertical position.
Oil Testing
Ÿ Drain oil into a clean, dry
container by placing pump on it’s side, remove pipe plug, from housing.
Ÿ Check oil for contamination using
an oil tester with a range to 30 kilovolts breakdown.
Ÿ If oil is found to be clean and
uncontaminated (measuring above 15 kV breakdown), refill the housing.
Ÿ If oil is found to be dirty or
contaminated (or measures below 15 kV breakdown), the pump must be carefully inspected for leaks at the shaft seal, cable
barmesapumps.com
assembly, square ring and pipe plug, before refilling with oil. To locate the leak, perform a pressure test.
After leak is repaired, dispose of old oil properly, and refill with new oil.
Pressure builds up extremely fast, increase pressure by "TAPPING" air nozzle. Too much pressure will damage seal. DO NOT exceed 10 PSI.
Oil Replacement - Set unit upright and refill with new cooling oil as per table below. Fill to just above motor, but below capacitor as an air space must remain in the top of the housing to compensate for oil expansion.
Apply pipe thread compound to threads of pipe plug then assemble to housing.
DO NOT overfill oil. Overfilling of housing with oil can create excessive and dangerous hydraulic pressure which can destroy the pump and create a hazard.
Overfilling oil voids warranty.
Cooling Oil
Recommended Supplier/Grade
BP Enerpar SE100 Conoco Pale Parafin 22 Mobile D.T.E. Oil Light Shell Canada Transformer-10 Texaco Diala-Oil-AX
Disassembly
Impeller and Volute:
1. Disconnect power.
2. Remove cap screws, volute and gasket.
3. Clean and examine impeller, for cracks or breakage and replace if required. To remove impeller, place a flat screwdriver in the slot of the end of the shaft to hold the shaft stationary while unscrewing.
4. Check v-ring and remove if damaged.
Power Cord and Motor:
5. Remove pipe plug and drain oil from housing.
6. Remove gland nut, washer and nylon housing from motor housing. Pull cord through and disconnect the wires from the terminals on power cord.
7. Remove screws and washers and lift motor housing and stator from seal plate.
8. Remove o-ring, replace if damaged.
9. Check motor capacitor with an Ohm meter by first grounding the capacitor by placing a screwdriver across both terminals and then removing screwdriver. Connect Ohm meter (set on high scale) to terminals. If needle moves to infinity (∞) then drifts back, the capacitor is good. If needle does not move or moves to infinity (∞) and does not drift back, replace capacitor.
10. Inspect motor winding for shorts and check resistance values. Check rotor for wear. If rotor or the stator windings are defective, the complete motor must be replaced.
Shaft Seal:
11. Remove snap ring from seal plate. Remove shaft and motor rotor from seal plate.
12. Remove seal’s rotating member, spring and retaining ring from seal plate. Examine all seal parts, if seal faces show signs of wear, uneven wear pattern, chips or scratches replace entire seal. DO NOT
interchange seal components, replace the entire shaft seal. If
replacing seal, remove stationary by prying out with flat screwdrive.
Bearings:
13. Examine lower bearing, and upper bearing, if replacement is required, remove by using a wheel puller.
05
Page 7
Service
Reassembly
IMPORTANT! - All parts must be clean before
reassembly. Handle seal parts with extreme care. DO NOT damage lapped surfaces.
Bearings:
1. Press bearings and onto shaft.
Shaft Seal:
2. Clean seal cavity in seal plate and oil. Press seal’s stationary member firmly into seal plate, use a seal tool or pipe. Nothing should come in contact with the seal face except the seal tool. Be sure the stationary is in straight.
3. Place seal’s retaining ring, spring onto shaft. Lightly oil (Do not use grease) shaft and inner surface of bellows.
Power Cord:
8. Check power cord for cracks or damage and replace if required. Reconnect motor leads.
9. Place power cord with nylon housing, ring, washer and gland nut into housing and tighten gland nut to 17.5 ft/lbs.
Impeller, V-ring and Volute:
10. Position v-ring into seal plate until seated.
11. Clean the threads with thread locking compound cleaner. Apply removable Loctite® 242 or equivalent to shaft threads. Screw impeller onto the shaft hand tight while using a screwdriver in the slot at the end of the shaft to hold it stationary. Rotate impeller to check for binding.
12. Position gasket on volute flange
barmesapumps.com
4. With lapped surface of seal’s rotating member facing outward, slide over shaft using a seal tool, being carefull not to damage seal face. Make sure spring is seated in retaining ring and spring is lined up on rotating member and not cocked or resting on bellows tail.
Motor:
5. Slide rotor/shaft with bearings and seal parts into seal plate until bearing seats into seal plate. Install snap ring into seal plate.
6. Lower housing while stringing motor leads through the cord entry bore, with motor stator onto seal plate.
and position impeller and motor housing assembly on volute.
13. Place screws into volute and torque to 11 ft/lbs. Check for free rotation of impeller.
14. Refill with cooling oil.
7. Place screws with washers through housing into seal plate and torque to 60 in/lbs.
06
Page 8
2SEV512
Repair Parts
barmesapumps.com
For Repair Part Please supply: Model Number and Serial as shown on Name Plate, and Part Description and Part Number as shown on Parts List.
07
Page 9
Parts List
2SEV512
ITEM DESCRIPTION QTY. MATERIAL
1 Cable assembly 20 ft ­2 Pump body 1 HT200 3 Capacitor 30uf/300V 90 °C 1 Plastic Pin 4 Capacitance clip 1 08F 5 Cross recessed pan head screw M4x10 2 Q235A 6 Ground lead 1 ­7 Upper bearing plate 1 ZL102 8 Temperature protector 17AM032-05 1 -
9 Stator 1 ­10 Rotor 1 ­11 Lower bearing plate 1 HT200 12 Bearing 6203 Z3 1 ­13 Mechanical seal 1 CC/SiC 14 Impeller 1 HT200 15 Hex socket cap screws 1/4" - 20UNCx28 5 304
barmesapumps.com
16 Casing 1 HT20 17 Handle 1 304+NBR40 18 Hex bolt 1/4" - 20UNCx13 2 304 19 Name plate 1 304 20 Nail for name plate 2x6 4 Cu 21 Hex socket pipe stropper 1/4" - 18 NPT 1 304 22 Vortex shell gasket 1 NBR41 23 Hex socket cap head screws 1/4" - 20UNCx18 2 304 24 O-ring Ø5.25" x 0.25" 1 NBR40 25 Lengthen bolt M4x100 2 Q235A 26 Bearing 6200 Z3 1 ­27 Wave washer Ø1.125" 1 65Mn 28 Cable guard 1 NBR40
29 Float switch 1 ­30 Clamp 1 2Cr13+NBR40 31 Cross recessed pan head screw
#10 - 31UNFx12 1 304
0
For Repair Part Please supply: Model Number and Serial as shown on Name Plate, and Part Description and Part Number as shown on Parts List.
08
Page 10
Troubleshooting Chart
Risk of electric shock. Always disconnect the pump from the power source before handling inspections or repairs.
Symptom Possible Cause(s) Corrective Action
1. Poor electrical connection, blown fuse, tripped breaker or other interruption of power; improper power supply
2. Motor or switch inoperative (go to manual
Pump will not run
Pump will not turn off
Pump hums but doesn’t run
Pump delivers insufficient capacity
barmesapumps.com
Pump cycles too frequently or runs periodically when f ixtures are not in use
Pump shuts of f and turns on independent of switch, (trips thermal overload protector). CAUTION! Pump may start unexpectedly. Disconnect power supply.
Pump operates noisily or vibrates excessively
NOTE: Barmesa Pumps assumes no responsibility for damage or injury due to disassembly in the field. Disassembly of the pumps or supplied accessories other than at Barmesa Pumps or its authorized service centers, automatically voids warranty.
operation) 2a. Float movement restricted 2b. Switch will not activate pump or is defective 2c. Defective motor
3. Insuffi cient liquid level
2a. Float movement restricted 2b. Switch will not activate pump or is defective
4. Excessive inflow or pump not properly sized for application
9. Pump may be air locked causing pump not to flow
14. H-O-A switch on panel is in "HAND" position
1. Incorrect low voltage
8. Impeller jammed or loose on shaft, or inlet
plugged
1. Incorrect low voltage
4. Excessive inflow or pump not properly sized for
application
5. Discharge restricted
6. Check valve partially closed or installed backwards
7. Shut-off valve closed
8. Impeller jammed or loose on shaft, or inlet
plugged
9. Pump may be air locked causing pump not to flow
10. Piping fixtures leaking or discharge before the
nozzle
6. Check valve partially closed or installed backwards
11. Fixtures are leaking
15. Ground water entering basin
1. Incorrect low voltage
4. Excessive inflow or pump not properly sized for
application
8. Impeller jammed or loose on shaft, or inlet
plugged
12. Excessive water temperature (internal
protection only)
2c. Worn bearings, motor shaft bent
5. Debris in impeller cavity or broken impeller
10. Pump running backwards
13. Piping attachments to building structure too
loose or rigid
1. Check all electrical connections for security. Have electrician measure current in motor leads, if current is within ± 20% of locked rotor Amps, impeller is probably locked. If current is 0, overload may be tripped. Remove power, allow pump to cool, then re-check current. 2a. Reposition pump or clean basin as required to provide adaquate clearance for float 2b. Disconnect level control. Set ohmmeter for a low rang, such as 100 ohms full scale and connect to level control leads. Actuate level control manually and check to see that ohmmeter shows zero ohms for closed switch and full scale for open switch. (Float Switch) 2c. Check winding insulation (Megger Test) and winding resistance. If check is outside of range, dry and re-check. If still defective, replace per service instructions.
3. Make sure liquid level is above the pump
4. Re-check all sizing calculations to determine proper pump size.
5. Check discharge line for restrictions, including ice if line passes through or into cold areas.
6. Remove and examine check valve for proper installation and freedom of operation
7. Open valve
8. Check impeller for freedom of operation, security and condition. Clean impeller cavity and inlet of any obstruction
9. Loosen union slightly to allow trapped air to escape. Verify that turn-off level of switch is set
so that the suction is always flooded. Clean vent hole
10. Check rotation. If power supply is three phase,
reverse any two of three power supply leads to ensure proper impeller rotation
11. Repair fixtures as required to eliminate leakage
12. Check pump temperature limits and fluid
temperature
13. Replace portion of discharge pipe with flexible
connector or tighten existing piping.
14. Turn to automatic position
15. Check for leaks around basin inlet and outlets
09