Barmesa Pumps 2AHS051, 2AHS101A, 2AHS051A, 2AHS101, 2AHS103 Installation, Operation & Maintenance Manual

...
Page 1
2AHS
0.5, 1 & 2 HP @ 3500 RPM
Installation, Operation &
Maintenance Manual
Submersible Dewatering Pumps
IMPORTANT! - Read all instructions in this manual before operating or servicing a pump.
Page 2
General Safety Information
Before installation, read the following instructions carefully. Failure to follow instruction and safety information could cause serious bodily injury, death and/or property damage. Each Barmesa product is carefully inspected to insure proper performance. Closely following these instructions will eliminate potential operating problems, assuring years of trouble-free service.
DANGER
nently hazardous situation which, if not avoided, WILL result in death or serious injury.
WARNING
nenty hazardous situation which, if not avoided, MAY result in death or serious injury.
CAUTION
hazardous situation which, if not avoided, MAY result in minor or moderate injury.
Indic ates an i mmi-
Indicate s an immi-
Indicates a potentially
IMPORTANT! - Barmesa Pumps is not responsible for losses, injury or death resu lting from fai lure to observe these safety precautions, misuse, abuse or misapplication of pumps or equipment.
A L L R E T U R N E D P R O D U C T S M U S T B E
CLEANED, SANITIZED, OR DECONTA M I N AT ED P RIOR TO SHIPMENT, TO INSURE EMPLOYEES WILL NOT BE EXPOSED TO HEALTH HAZA RD S IN HAN DLING S AID MATERIAL. ALL APPLICABLE LAWS AND REGULATIONS SHALL APPLY.
WARNING
junc tio n co nne ct ion s must be in accordance with the National Electric Code and all applicable state and local codes. Requirements may vary depending on usage and location.
Installation, wiring, and
WARNING
se rvicing is to be conducted by qualified personnel only.
power connected; the rotating cutter and/or impeller can cause serious injuty.
may become entangled in moving parts.
DANGER
before handling or servicing the p u m p o r a ny accessory i t e m s associated with or near the pump.
DANGER
human contact with pumped fluid.
DANGER
handling any aspect of the pumping system. Lock out power & tag.
WARNING
pumps in water over 104 °F. Do not exceed manufactures recommended maximum performance, as this could cause the motor to overheat.
DANGER
shock, burns or death. Never handle connected power cords with wet hands. Use appropriate lifting device.
I n s t a l l a t i o n a n d
Keep clear of suction and discharge openings. Do not insert fingers in pump with
Always wear eye protection when working on pumps. Do not wear loose clothing that
Pumps build up heat and pressure during operation. Allow time fo r p umps t o c ool
T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is
Risk of electric shock. To reduce risk of electric shock, always disco nnect pump from power source before
D o n o t u se t h e se
Do not lift, carry or
hang pump by the electrical c a b l e s . D amage to t h e electrical cables can cause
WARNING
Interrupter (GFCI) to be used with plug-in type power cord.
DANGER
burns or death.
DANGER
Electric Code, ANSI/NFPA 70.
WARNING
Code (UP C) s tat es that sew age systems shall have an audio and visual alarm that signals a malfunction of the systems, that are required to reduce the potencial for property damage.
IMPORTANT! - Prior to installation, record Model Number, Serial, Amps, Voltage, Phase and HP from pump name plate for the future reference. Also record the Voltage and Current Readings at Startup:
Model Number:_____________________
Serial:_____________________________
Amps:___________ Volts:____________
Phase:____________ HP:_____________
Ground Fault Circuit
Failure to permanently ground the pump, motor and controls before connecting to power can cause shock,
These pumps are not to be i nstal led in l ocati ons classified as hazardous in accordance with the National
The Uniform Plumbing
01
Page 3
Specifications & Dimensions
DISCHARGE: 2" NPT, vertical, adapter included.
SPHERICAL SLD HNDLG: 1/2"
LIQUID TEMPERATURE: 104 °F (40 °C) max.
PUMP BODY: Cast iron FC-200.
MOTOR HOUSING: Aluminum alloy ADC12.
OIL CHAMBER: Cast iron FC-200.
IMPELLER: 8 vane, semi-open Vortex. Hytrel® thermoplastic elastomer.
SHAFT: 410 series stainless steel.
HARDWARE: 304 series stainless steel.
O-RINGS: .Nitrile rubber (NBR)
PAINT: Air dry enamel, water based.
SEAL: Double mechanical, oil filled chamber. Upper part of carbon-ceramic, lower part of
silicone carbide. Stainless steel hardware.
CORD ENTRY: 15 ft of neoprene cord , sealed against moisture.
BEARINGS: Ball, single row, permanently oil lubricated for 60,000 hours of work. Designed for
radial and axial loads.
MOTOR: Dry type submersible motor, 1 & 3 phase, 115 & 230 volts, 60 Hz, 3500 RPM. For
continuous duty, with thermal protector IP68 in winding, insulation class B.
STRAINER: Polyvinyl chloride (PVC).
HANDLE: Nylon 6.
PUMP OPERATION: Available as "A" Automatic model or Manual operation (no level control).
MODEL PART No. HP VOLTS PHASE
2AHS051 62180101 27
2AHS051A 62180102 28
2AHS101 62180103 33
2AHS101A 62180104 34
2AHS103 70090005 1 230 3 3500 3 16 AWG/3C 14.84" 10.98" Ø7" 4.75" 5,24" 34
2AHS203 70090007 2 230 3 3500 7 14 AWG/3C 18.27" 12.32" Ø7.5" 5.13" 6.1" 42
A = Automatic Float Switch. A control panel is needed for the 3 phase pumps to operate in automatic.
115
1
1
RPM
(Nominal)
3500 6 16AWG/3C 13.86" 9.57"0.51115
MAX
AMPS
CORD
SIZE
AAA
A B C D E
Ø7" 4.25" 4.61"
10.98"14.84"16 AWG/3C123500
BBB
EEE
WEIGHT
(pounds)
5.24"4.75"Ø7"
CCC
DDD
02
Page 4
Installation
Receiving inspection
Upon receiving the pump, it should be inspected for damage or shortages. If damage has occurred, file a claim immediately with the company that delivered the pump. If the manual is removed from the packaging, do not lose or misplace.
Storage
Any product that is stored for a period longer than six (6) months from the date of purchase should be bench tested prior to installation. A bench test consists of, checking the impeller to assure it is free turning and a run test to assure the motor (and switch if provided) operate properly.
Before Installation
Insulation resistance measurement With the motor and cable (excluding the power supply cable) immersed in water, use a megger to measure the insulation resistance between ground and each phase of the motor, and again between each phase of the
motor. The megger should indicate an insulation resistance of not less than 20 mega ohms. While making the measurement, keep the power supply cable off the ground. We
recommend that an auxiliary pump be kept on hand in case of emergency.
Installation
WARNING
should cable be pulled while the pump is bein g t r ansporte d o r installed. Attach a chain or rope to the grip and install the pump.
1.This pump must not be installed
on its side or operated in a dry condition. Ensure that it is installed upright on a secure base.
2.Install the pump at a location in
the tank where there is the least turbulence.
Under no circumstances
3.If there is a flow of liquid inside
the tank, support the piping where appropriate. Install piping so that air will not be entrapped. If piping must be installed in such a way that air pockets are unavoidable, install an air release valve wherever such air pockets are most likely to develop.
4.Do not permit end of discharge
piping to be submerged, as backflow will result when the pump is shut down.
WARNING
(models 2AHS), have an automatic operating system bump operating water leve l n e ar the minim um operating level as the automatic cut­off switch incorporated inside the motor will be activated. To avoid dry oper atio n, ins ta ll an auto m atic operating system, as shown in Figure 1 and maintain a safe operating water level (C.W.L.: continuous water level = 90 mm).
5.For automatic pumps (models
2AHS-A), install the floats as shown in figure 2. The pump may not start if a floats switch touches the wall of the water tank or the piping. Install the floats so that this will not happen.
C.W.L.
Figure 1
Non-automatic pumps
ON
OFF
Figure 2
Wiring:
a) Wire as indicated for the
appropiate start system as shown in figure 3.
b) Loose connections will stop the
pump. Make sure all electrical connections are secure.
Cable:
WARNING
the cable contact water.
d) If the cable is extended, do not
immerse the splice in water.
e) Fasten the cable to the discharge
piping with tape or vinyl strips.
f) Install the cable so that it will not
overheat. Overheating caused by coiling the cable and exposing it to direct sunlight.
Grounding:
Connect the green wire to ground. Under no circumstances should the green wire be connected to the power supply.
DANGER
c) Never let the end of
U s e s h o r t c i r c u i t breakers to prevent danger of electrical shock.
03
Page 5
Single phase
Electrical Wiring
Capacitor
Black
(Brown)
White (Blue)
Green
(Green/Yellow)
Frame
Grounding
Ground
Three phase
Black
R
(Black)
White
S
(Blue)
T
Red
(Brown)
(Green/Yellow)
Ground
U
V
W
Green
Protector
U2
V2
W2
Grounding
Frame
Main
Coil
Starting
Coil
Overload Protector
Figure 3
04
Page 6
Operation & Maintenance
Before Starting the Pump
1) After completing installation, measure the insulation resistance again as described in Installation.
2) Check water level. If the pump is operated continuously for an extended period of time in a dry condition or at the lowest water level, the motor protector will be activated. Constant repetition of this action will shorten pump service life. Do not start the pump again in such a situation until after the motor has completely cooled.
Test operation
Automatic (2AHS-A) and non­automatic (2AHS) pump:
1) Turn the operating switch on and off a couple of times to check for normal pump start.
For the 2AHS-A:
Floating switch must be raised for the pump to start.
2) Next, check direction and rotation.
If discharge volume is low or unusual sounds are heard when the pump is operating, rotation has been reversed. When this happens, reverse two of the wires.
Monthly inspections: Measure the insulation resistance. The value should be more than 1M ohm. If resistance starts to fall rapidly even with an initial indication of over 1M ohm, this may be an indication of trouble and repair work is required.
Annual inspections: To extend the service life of the mechanical seal, replace the oil in the mechanical seal chamber once a year. Water mixed with the oil or cloudy textures are indications of a defective mechanical seal requiring replacement. When replacing the oil, lay the pump on its side with filler plug on top. Inject suitable amount turbine oil no. 32 (ISO VG-32).
Inspections at 3-5 year intervals: Conduct an overhaul of the pump. These intervals will preclude the possibility of future trouble.
Parts that will need to be replaced: Replace the appropriate part when the following conditions are apparent. See figure 4. (Note: replacement schedule is based on normal operating conditions)
Disassembly
Maintenance
Check pressure, output, voltage, current and other
specifications. Unusual readings may indicate. Refer to Troubleshooting and correct as soon as possible.
Daily inspections:
1) Check current and ammeter
fluctuation daily. If ammeter fluctuation is great, even though within the limits of pump rating, foreign matter may be clogging the pump. If the quantity of liquid discharged falls suddenly, foreign matter may be blocking the suction inlet.
When disassembling pump, have a piece of cardboard or wooden board ready to place the different parts on as you work. Do not pile parts on top of each other. They should be laid out neatly in rows. The o-ring and gasket cannot be used again once they are removed. Have replacement parts ready. Disassemble in the following order, referring to the sectional view.
Figure 4
REPLACEABLE
PART
REPLACEAMENT
GUIDE
FREQUENCY Annually Every 6 months Every 6 months Annually
Mechanical seal
Whenever oil in mechanical seal
chamber is
clouded
Oil filler plug
gasket
Whenever oil is
replaced or
inspected
WARNING
source before disassembly.
1. Remove pump casing bolts, raise the motor section and remove pump casing.
2. Remove shaft head bolt and impeller.
3. Remove oil filler plug and drain lubricating oil.
4. Remove intermediate casing bolts and intermediate oil chamber. (Remember that any lubricating oil remaining in the mechanical seal chamber will flow out.)
5. Carefully remove mechanical seal, taking care not to scratch sliding surface or motor shaft.
Be sure to cut off power
Assembly
Re-assemble in reverse order of disassembly. Be careful of the following points:
6. During re-assembly, rotate the impeller by hand and check for smooth rotation. If rotation is not smooth, perform steps (3) through (5) again.
7. Upon completion of re-assembly step 1 rotate the impeller by hand from the suction the suction inlet and check that it rotates smoothly without touching the suction cover before operating the pump.
Please obtain o-rings, packing, shaft seals and other parts from pump dealer.
Lubricating oil O-ring
Whenever
clouded or dirty
Whenever pump
is overhauled
05
Page 7
2AHS 0.5 HP
Repair Parts
Figure 5
For repair part please supply: Model Number and Serial as shown on Name Plate, and Part Description and Part Number as shown on Parts List.
06
Page 8
2AHS 0.5 HP
ITEM NAME MATERIAL PHOTO ITEM NAME MATERIAL PHOTO
Parts List
1 CABLE H07/UL 13
2 HANDLE NYLON 6 13
3
4 BRACKET SECC 15 BEARING
5
6
7 OIL CHAMBER CAST IRON 21
MOTOR
COVER
MOTOR HOUSING
+ STATOR
SHAFT WITH
ROTOR
ADC12 14 CAPACITOR
ADC12 16 STRAINER PVC
SUS410 17 O-RING NBR
PROTECTOR
(1 PHASE)
(OPTIONAL)
PROTECTOR
(3 PHASE)
FLOAT SWITCH
(OPTIONAL)
MECHANICAL
8
11 IMPELLER HYTREL 27 FLANGE FC-15
12 PUMP CASING CAST IRON 28 AGITATOR SMF5030
SEAL
UPPER: CA/CE
LOWER: SIC/SIC
25
PLASTIC
HOSETAIL
ITEM NAME MATERIAL ITEM NAME MATERIAL
18 GASKET NBR 19-6 SCREW SUS 304 18-1 GASKET NBR 19-7 SCREW SUS 304 18-2 GASKET NBR 20 WASHER SUS 304
19 SCREW SUS 304 22 SCREW WITH O-RING 19-1 SCREW SUS 304 23 CABLE SEAT 19-2 SCREW SUS 304 24 EARTH LINE AND SCREW 19-3 SCREW SUS 304 26 "T" ADAPTER (OPTIONAL) 19-4 SCREW STEEL 29 INSULATING PAPER 19-5 SCREW SUS 304 34 CORRUGATED SPRING STEEL
For repair part please supply: Model Number and Serial as shown on Name Plate, and Part Description and Part Number as shown on Parts List.
07
Page 9
2AHS 1 HP
Repair Parts
Figure 6
For repair part please supply: Model Number and Serial as shown on Name Plate, and Part Description and Part Number as shown on Parts List.
08
Page 10
2AHS 1 HP
Parts List
ITEM NAME MATERIAL PHOTO ITEM NAME MATERIAL PHOTO
1 CABLE H07/UL 13
2 HANDLE NYLON 6 13
3
4 BRACKET SECC 15 BEARING
5
6
7 OIL CHAMBER CAST IRON 21
MOTOR
COVER
MOTOR HOUSING
+ STATOR
SHAFT WITH
ROTOR
ADC12 14 CAPACITOR
ADC12 16 STRAINER PVC
SUS410 17 O-RING NBR
PROTECTOR
(1 PHASE)
(OPTIONAL)
PROTECTOR
(3 PHASE)
FLOAT SWITCH
(OPTIONAL)
MECHANICAL
8
11 IMPELLER HYTREL 27 FLANGE FC-15
12 PUMP CASING CAST IRON 28 AGITATOR SMF5030
SEAL
UPPER: CA/CE
LOWER: SIC/SIC
25
PLASTIC
HOSETAIL
ITEM NAME MATERIAL ITEM NAME MATERIAL
18 GASKET NBR 19-6 SCREW SUS 304 18-1 GASKET NBR 19-7 SCREW SUS 304 18-2 GASKET NBR 20 WASHER SUS 304
19 SCREW SUS 304 22 SCREW WITH O-RING 19-1 SCREW SUS 304 23 CABLE SEAT 19-2 SCREW SUS 304 24 EARTH LINE AND SCREW 19-3 SCREW SUS 304 26 "T" ADAPTER (OPTIONAL) 19-4 SCREW STEEL 29 INSULATING PAPER 19-5 SCREW SUS 304 34 CORRUGATED SPRING STEEL
For repair part please supply: Model Number and Serial as shown on Name Plate, and Part Description and Part Number as shown on Parts List.
09
Page 11
2AHS 2 HP
Repair Parts
Figure 7
For repair part please supply: Model Number and Serial as shown on Name Plate, and Part Description and Part Number as shown on Parts List.
10
Page 12
2AHS 2 HP
Parts List
ITEM NAME MATERIAL PHOTO ITEM NAME MATERIAL PHOTO
1 CABLE H07/UL 12 PUMP CASING CAST IRON
2 HANDLE NYLON 6 13
3 MOTOR COVER ADC12 13
4 BRACKET SECC 14 CAPACITOR
MOTOR HOUSING
5
+ STATOR
SHAFT WITH
6
7 OIL CHAMBER A A356 17 O-RING NBR
ROTOR
ADC12 15 BEARING
SUS410 16 STRAINER PVC
7-1 OIL CHAMBER B A356 21
PROTECTOR
(1 PHASE)
(OPTIONAL)
PROTECTOR
(3 PHASE)
FLOAT SWITCH
(OPTIONAL)
MECHANICAL
8
10 OIL SEAL NBR 27 FLANGE FC-15
11 IMPELLER HYTREL 28 AGITATOR SMF5030
SEAL
ITEM NAME MATERIAL ITEM NAME MATERIAL
18 GASKET NBR 19-6 SCREW SUS 304 18-1 GASKET NBR 19-7 SCREW SUS 304 18-2 GASKET NBR 20 WASHER SUS 304
19 SCREW SUS 304 22 SCREW WITH O-RING 19-1 SCREW SUS 304 23 CABLE SEAT 19-2 SCREW SUS 304 24 EARTH LINE AND SCREW 19-3 SCREW SUS 304 26 "T" ADAPTER (OPTIONAL) 19-4 SCREW STEEL 29 INSULATING PAPER 19-5 SCREW SUS 304 34 CORRUGATED SPRING STEEL
UPPER: CA/CE
LOWER: SIC/SIC
25
PLASTIC
HOSETAIL
For repair part please supply: Model Number and Serial as shown on Name Plate, and Part Description and Part Number as shown on Parts List.
11
Page 13
Troubleshooting Chart
Risk of electric shock. Always disconnect the pump from the power source before handling inspections or repairs.
Symptom Possible Cause(s) Corrective Action
(1) Power failure (2) Large discrepancy between power source and voltage (3) Significant drop in voltage (4) Motor phase malfunction (5) Electric circuit connection faulty
(6) Faulty connection of control circuit Does not start. Starts, but imediately stops.
Operates, but stops after a while.
Does not pump. Inadequate volume.
Over current.
Pump vibrates; excessive operating noise.
(7) Fuses is blown
(8) Faulty magnetic switch
(9) Water is not at level indicated by float
(10) Float is not in appropriate level
(11) Float is not effective
(12) Short circuit breaker is functioning
(13) Foreign matter clogging pump
(14) Motor burned out
(15) Motor bearing broken
(1) Prolonged dry operation has activated
motor protector and caused pump to stop
(2) High liquid temperature has activated
motor protector and caused pump to stop
(3) Reverse rotation
(1) Reverse rotation
(2) Significant drop in voltage
(3) Operating a 60 Hz pump with 50 Hz
(4) Discharge head is high
(5) Large piping loss
(6) Low operating water level causes air
suction
(7) Leaking from discharge piping
(8) Clogging of discharge piping
(9) Foreign matter in suction inlet
(10) Foreign matter clogging pump
(11) Worn impeller
(1) Unbalanced current and voltage
(2) Significant voltage drop
(3) Motor phase malfunction
(4) Operating 50 Hz pump on 60 Hz
(5) Reverse rotation
(6) Low head. Excessive volume of water
(7) Foreign matter clogging pump
(8) Motor bearing is worn out or damaged
(1) Reverse rotation
(2) Pump clogged with foreign matter
(3) Piping resonates
(4)Strainer is closed too far
(1)~(3) Contact electric power company and devise counter-measures (4) Inspect electric circuit (5) Correct wiring (6) Inspect connections and magnetic coil (7) Check circuit then replace fuse (8) Replace with correct one (9) Raise water level (10) Adjust the position of float (11) Repair or replace (12) Repair location of short circuit (13) Remove foreign matter (14) Repair or replace (15) Repair or replace
(1) Raise water level to C.W.L. (2) Lower liquid temperature (3) Correct rotation
(1) Correct rotation (see Operation) (2) Contact electric power company (3) Check nameplate (4) Recalculate and adjust (5) Recalculate and adjust (6) Raise water level or lower pump (7) Inspect, repair (8) Remove foreign matter (9) Remove foreign matter (10) Remove foreign matter (11) Replace impeller
(1) Contact electric power company (2) Contact electric power company and devise counter-measure (3) Inspect connections and magnetic switch (4) Check nameplate (5) Correct rotation (see Operation 2) (6) Replace pump with high head pump (7) Remove foreign matter (8) Replace bearing (1) Correct rotation (2) Disassemble and remove foreign matter (3) Improve piping (4) Open strainer
NOTE: Barmesa Pumps assumes no responsibility for damage or injury due to disassembly in the field. Disassembly of the pumps or supplied accessories other than at Barmesa Pumps or its authorized service centers, automatically voids warranty.
12