Barksdale Control Products B1X, B2X Technical Data

Page 1
Mechanical single/dual pressure switch Repeatability ±1.0 % at constant temperature
Features
Bourdon tube pressure switchAll welded parts wettedDirect acting, no friction, high accuracyApprovals: Ex ia, Ex d, UL, CSA, SIL 2/3 (IEC 61508)
Adjustment ranges
5.3 ... 496 bar
Applications
Petrochemicals industry, Process technology, Shipbuilding technology, Alarm applications
Index: G / 923-1500
B1X/B2X Bourdon Tube Press. Switches `B1X/B2X
Technical Data
Wetted parts:
Process connection: Bourdon tube:
Repeatability:±1 % at constant temperature Switching rate:max. 20/min Temperature range:-40 °C... +75 °C Protection class:IP65 Housing:Explosion proof housing, aluminum
Process connection:1/4" NPT female thread except
Electrical connection:Internal terminal strip (0.5 - 2.5
Electrical rating and hysteresis:
Pressure Ranges
Pressure range
code
12SS5.3... 833.4... 81100.125.0.96.1.86. 20SS13.7... 13711.0... 134250.330.2.68.5.44. 32SS22.4... 22016.5... 215400.500.2.75.5.90.
72SS*79.3... 49641.4... 459600.950.16.90.37.90.
Increasing press.Decreasing press.(short term)H, GH [bar]M, GM [bar]
Stainless steel 1.4401 Stainless steel 1.4401
anodized and lacquered
ranges marked with*). These switches have proof pressures above 500 bar and are provided with high pressure thread with adapter G1/4'' IG.
2
mm
), approved cable gland has to
be provided by the customer Many micro switch versions with
different switching powers and hysteresis are applicable and make it possible to make customized changes.
Adjustment range [bar]
Max. operating
pressure [bar]
Weight:B1X-...: approx. 3.9 kg
Set point adjustment:Turn the adjustment screw
Intrinsically safe:The switches are designed for
Approval:Ex: Ex d II C T6 acc. to ATEX
Proof pressure
[bar]
B2X-...: approx. 3.9 kg
clockwise to decrease the set point.
intrinsically safe applications. Please add "Exi" to your ordering details when placing an order. To comply with the intrinsically safe approval following max. ratings must not be
exceeded: Umax = 28 V Imax = 50 mA
cULus:
Class I, Groups B, C, D Class II, Groups E, F , G acc. to Underwriter Laboratories Inc. and Canadian Standard Assn.
Max. hyst. of the different switches in
bar (end of range)
Barksdale
Subject to technical changes.
1
Loading...