This “Instruction, Use and Maintenance Manual” has been prepared to provide guidance and
recommendations to assist qualified skilled technicians in the understanding, running and
maintenance orf the Products supplied.
It forms an integral part of the Products supplied and must be read prior to any installation,
operation and/or maintenance of all types of valves provided.
This manual must be saved for future reference and be kept readily available at the unit.
With regards to the use of valves compliant with EU Directive 2014/34/UE (ATEX), consultation
The essential characteristics of all types of valves described herein being consistent, the
Manufacturer reserves the right to alter and or complement and or update at any time and with
no obligation to notify so in writing, the data and or information relevant to the use of the valves
described in this "Instruction, Use and Maintenance Manual".
A constantly updated version of this "Instruction, Use and Maintenance Manual" is available
at the Manufacturer's website www.bardianivalvole.it.
Under no circumstance shall the Manufacturer be held liable for consequences resulting
from failure and or improper use of the instructions contained in this Manual and relating to
the installation, operating, maintenance and storage of the products.
All rights reserved.
Full or part reproduction, transfer and or recording of any part of this "Instruction, Use and
Maintenance Manual" by all means, whether it be electronic, on hard copy, mechanical or any
other means or recording or reuse is strictly prohibited without the prior written consent of the
Manufacturer and for any use other than that of the Buyer.
(Translation of the Original Instructions in the italian Language)
4
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
1 Safety,Warning and Mandatory Signs
WARNING SIGNS
PictogramDescriptionNotes
WARNING
General
WARNING
Hand crushing
This tells the person in question that the operation
described involves (when not performed in accordance
with the relative safety regulations) the risk of personal
injury.
Exercise caution in executing the procedure
Hand crushing hazard
WARNING
Heavy loads
WARNING
Severe burns
WARNING
Risk of explosions
MANDATORY SIGNS (FOR THE OPERATOR IN CHARGE OF ASSEMBLY/DISASSEMBLY)
PictogramDescriptionNotes
OBLIGATION
General
PROTECTIVE GLOVES
Exercise caution in executing the procedure
Heavy suspended loads.
Heat emission hazard Very hot surface, risk of severe
burns
Take Care, risk of explosions
Special instructions must be followed to avoid injury to
persons.
Safety gloves must be available for handling objects
which could cause hand injuries.
EN-IST-BBZP-0418
HARD HAT
FOOTWEAR
SUITABLE CLOTHING
A hard hat must be worn during machine lifting
operations to protect against hazards generated by
suspended loads.
Use safety footwear to protect against the risks of
falling objects during operations to transport the
machine.
Suitable clothing such as overalls. It is strictly
prohibited to wear clothes with large flapping sleeves
and/or other loose items which could easily get caught
up in machine parts.
5
Instruction, Use and Maintenance Manual
MANDATORY SIGNS (FOR THE OPERATOR IN CHARGE OF MECHANICAL MAINTENANCE)
PictogramDescriptionNotes
OBLIGATION
General
Special instructions must be followed to avoid injury to
persons.
PROTECTIVE GLOVES
HARD HAT
FOOTWEAR
SUITABLE CLOTHING
SAFETY GLASSES
Protective gloves must be available for handling
objects which could cause hand injuries or when there
is the possibility of coming into contact with harmful
substances..
Hard hats must be available when lifting heavy parts.
Use safety footwear to protect against injuries caused
by falling objects during maintenance operations
(particularly when dismantling parts).
Suitable clothing such as overalls. It is strictly
prohibited to wear clothes with large flapping sleeves
and/or other loose items which could easily get caught
up in machine parts.
Protective glasses must be available when there is the
possibility of contact which harmful substances which
could cause eye injuries.
OPERATING SIGNS
PictogramDescriptionNotes
SKILLED
PERSONNEL
NOTE
ENVIRONMENTAL
NOTE
CLAMP
CLAMP WITH SOFT
JAWS
Dismantling/Assembling and maintenance operations must be
carried out by expert technicians only.
Follow the indicated note with care
Follow the regulations in force in the country of used
governing waste disposal.
Use of a clamp
Use of a clamp with jaws made from soft material
6
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
OPERATING SIGNS
PictogramDescriptionNotes
PRESS
Use of a press
PRESS
(release)
ELECTRICAL
CONNECTION
ELECTRICAL
DISCONNECTION
PNEUMATIC
CONNECTION
PNEUMATIC
DISCONNECTION
1
APPLICATION OF
FOODSAFE
GREASE
Use of a press Gradual release of the pressure force
Electrical connection to the control unit (consult the relative
instruction manual).
Electrical disconnection from the control unit (consult the
relative instruction manual).
Connection of the air to the valve.
Disconnection of the air from the valve
Use FOODLUBE HI-TEMP 2 15254 grease only
2
APPLICATION
OF FOODSAFE
GREASE
APPLICATION OF
MULTIPURPOSE
GREASE
THREADLOCK
APPLICATION
OPTIONAL
Use FOODLUBE Multi-paste 15756 grease only
Use AGIP GREASE MU EP 2 SE 463754 only
Use SPEED BOND M500 threadlock only
EN-IST-BBZP-0418
7
Instruction, Use and Maintenance Manual
2 General safety warnings
Intended use
Bardiani valves have been exclusively for moving fluids.
Prohibited use
The valve must not be used:
• for any operations different to those described under the heading “Intended Use”,
• for handling fluids different to the type specified by the manufacturer;
• for moving fluids at different pressures to those envisaged by the manufacturer and indicated in the
valve's technical data.
Limitations on valve use
It is forbidden to:
• use the valve in a construction configuration different to the one envisaged by the manufacturer.
• use the valve where there is a risk of explosion and/or fire, unless envisaged by the manufacturer (if
the valves are certified in accordance with Directive 2014/34/EU, please refer to the ATEX Manual)-;
• integrate other systems and/or equipment which were not considered by the manufacturer during the
executive design phase,
• use the valve for purposes other than those specifically envisaged by the manufacturer.
WARNING
The machine may not he used inside premises where there is a potentially explosive atmosphere or
with Directive 2014/34/EU please refer to the ATEX Manual).
BARDIANI VALVOLE S.p.A. declines all liability
for installation, use or maintenance which fails to comply with
the indications provided in this manual!
8
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
3 Technical data
VALVE DATA
Maximum pressurePN10
Maximum seal pressureSee catalogue
Storage temperaturefrom -10°C to 25°C
Material in contact with the productAISI 316L (1.4404). Check the resistance to corrosion in
relation to products and detergents
Gasket material in contact with the
product
Surface finish in contact with the
product
Connectors1/8” BSP
Steam maximum temperature130°C (266°F)
Gaskets materialFKM
EPDM, FKM, HNBR and other gaskets on request. Check
compatibility with products and detergents
Ra 0.8 µm. Other finishes available on request
VAPOUR BARRIER DATA
PNEUMATIC ACTUATOR DATA
Connectors1/8” BSP
Pipe dimensions6 mm external diameter, 4 mm internal diameter
Air pressurefrom 6 bar (87 psi) to 8 bar (116 psi)
Air qualityClass 2, 4, 3 ISO8573-1
External materialAISI 304L (1.4307)
SealsNBR
Noise levels76 dB
Electrical supplySee Giotto Top
GASKET MATERIALS COMPATIBILITY
ProductEPDMFKMHNBRMVQ
Temperature (applications with air)-10 to +140°C-10 to +200°C-10 to +130°C-70 to +230°C
Caustic soda 2%60°C30°CTo be checkedUnsuitable
Nitric Acid 2%60°C80°CTo be checkedUnsuitable
Saturated steam 125°CSuitableTo be checkedSuitableUnsuitable
GreasesUnsuitableSuitableSuitableUnsuitable
AlcoholsSuitableUnsuitableSuitableSuitable
The valve is complies to PED
2014/68/EU directive, with special reference to Annex III, Module A,
concerning internal manufacturing checks as indicated in the Conformity Assessment Procedures.
The DN15--25 valves are included in compliance with Article 4, paragraph 3:
Valves designed for use with gas, liquid gas, gases dissolved under pressure, steam and those liquids
with a vapour pressure at maximum admissible temperature exceeding 0.5 bar at normal atmospheric
pressure (1.013 mbar) within the following limits:
- For group 1 fluids when DN is from 25 to 100.
- For group 2 fluids when DN is 125 and over.
In the event of any doubt, please contact Bardiani Valvole S.p.A.
EN-IST-BBZP-0418
9
Instruction, Use and Maintenance Manual
4 Checking / Unpacking / Lifting
1. CHECK:
- Check the valve show no signs of damage caused during transport
and that it corresponds with the order;
- Check the inside of the valve.
2. UNPACKING:
The valve packaging is made up of cardboard, wood and plastic.
The valve is mainly made up of metal materials. The gaskets are
usually made from elastomers. Disposal must be in compliance with
local legislation.
10
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
3. VALVE LIFTING:
Take care as to the type of valve you are handling. Based on the size
there are two different lifting procedures.
CAUTION!
Before lifting the valve, make sure there are no disassembled or
separate valve parts which could fall off causing injury to persons
and damage to the valve.
A
BBZP
Size
DN
10-65A
80-100B
125-150C
Weight
Kg
DN10 and DN65
Weight lower to 25 kg
C
B
DN80 and DN100
Weight between 25 kg and 50 kg
CAUTION!
The figures above are used purely to represent the methods and procedures for hoisting the valves.
Bardiani Valvole S.p.A. declines all liability for any damage to things and/or injuries to persons caused
by improper and/or incorrect hoisting of the valve.
EN-IST-BBZP-0418
DN125 and DN150
Weight over 50 Kg
11
Instruction, Use and Maintenance Manual
5 Installation
1. ELECTRICAL AND PNEUMATIC ENERGY SUPPLY
- Use expert personnel for installation/uninstallation operations;
- Check that the air pressure and quality are correct (see "Technical
Data");
- Check the power supply to the control unit is correct (consult the
relative instruction manual).
A = Upward movement of the valve member
B = Downward movement of the valve member
In single acting valves there is only one of the aforementioned
commands.
2. REDUCING THE STRESS TO WHICH THE VALVE IS SUBJECTED:
- Vibrations;
- Thermal expansion of the piping;
- Excessive welding;
- Overload.
B
A
CAUTION!
The seal seats may become deformed or cause valve malfunctioning.
12
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
3. CORRECT DIRECTION OF FLOW:
Flow in the opposite direction to valve closure minimizes water
hammer
.
Valve 1L
4. VALVE CONNECTIONS/CONNECTORS:
If the valve is fitted with connectors, you may proceed with installation.
Correctly insert the gaskets and tighten the connectors
Valve 3LL
Valve P7-LL
Valve M8-LL
.
Valve M8-LLL
Valve M9-LLL
CAUTION!
Bardiani Valvole S.p.A. declines all liability for any damage to things
and/or injuries to persons caused by any failure to correctly follow the
installation procedures.
EN-IST-BBZP-0418
13
Instruction, Use and Maintenance Manual
5. WELDING THE VALVE BODY ONTO PIPING:
Remove the body from the rest of the valve before proceeding with
welding operations. Please refer to the following pages in this manual.
CAUTION!
Hand crushing hazard. During operation there is a risk of crushing
inside the valve body in the area between the actuator and the valve
body.
A
6. MINIMUM MAINTENANCE CLEARANCES:
Make sure there is enough room around the valve for it to be
disassembled (with the control unit installed).
Bardiani Valvole S.p.A. declines all liability for any damage to things
and/or injuries to persons caused by any failure to correctly follow the
installation procedures.
14
C
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
6 Operation
1. VALVE INSPECTION BEFORE OPERATION:
- Supply air to the actuator:
- Power the valve (via the control unit);
- Open and close the valve several times;
- Check that the valve works correctly and accurately.
A = Upward movement of the valve member
B = Downward movement of the valve member
In single acting valves there is only one of the aforementioned
commands.
B
A
CAUTION!
Hand crushing hazard. During operation there is a risk of crushing
inside the valve body in the area between the actuator and the valve
body.
2. DUAL FUNCTION OF THE VALVE CYLINDER:
Depending on how the valve cylinder is turned and installed, operation
will be in normally open or normally closed mode.
Normally closedNormally open
EN-IST-BBZP-0418
15
Instruction, Use and Maintenance Manual
7 Troubleshooting
PROBLEMPOSSIBLE CAUSEPOSSIBLE SOLUTION
External leak
Leaks inside the closed valve
caused by normal wear
External leak
Premature leaks inside the
closed valve
Difficulty opening and closing
Worn gasketReplace the seal
Excessive pressure
Excessive temperature
Aggressive fluids
Too many commands active
Difficulty opening and closing
Incorrect type of elastomer used
for the gaskets
Incorrect positioning of the
actuator
Incorrect operation of the
actuator
Impurities in the actuator
Incorrect valve body positioning
Replace with a gasket of a
different type of elastomer
Modify the operating conditions
Replace with a gasket of a
different type of elastomer
Install the actuator correctly
Change from normally open
(NO) to normally closed (NC) or
vice versa
Actuator inspection and
maintenance
Disassemble and correctly
reposition the valve body
16
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
8 Cleaning
1. VALVE CLEANING WITH DETERGENTS:
The system in which the valve is installed must be cleaned by expert
personnel in observance of the following:
- Abide by the indicated detergent concentration values;
- Observe the instructions provided by the detergent manufacturer.
- Always wear protective safety glasses and gloves.
Risk of
stainless steel
corrosion
IMPORTANT!
- Accurately dose detergents to avoid excessive concentration;
- Always rinse thoroughly with clean water after washing.
- Check compatibility of valve materials.
CAUTION!
Burns hazard. The valves and piping may be very hot. Wear protective
gloves
WARNING
After installing a new or serviced valve, perform an internal washing
cycle before using the piping for food liquids. If it there has been any
welding work, passivation treatment must be carried out.
Risk of damage
elastomers
EXAMPLE OF INTERNAL WASHING CYCLE (CIP)
PhasesTemperature °CWashing product
Initial rinseEnvironmentChlorine- and chloride-free
Washing70 °CCaustic soda (NaOH) at 1%
Intermediate rinseEnvironmentChlorine- and chloride-free
Washing70 °CNitric acid (HNO3) at 0.5%
End rinseEnvironmentChlorine- and chloride-free
Recommended washing product velocity = 2m/s
EN-IST-BBZP-0418
water
water
water
17
Instruction, Use and Maintenance Manual
9 General maintenance
1. MAINTENANCE PRECAUTIONS
Maintenance operations must be carried out by expert technicians
only.
CAUTION!
Maintenance operations must be carried out with the line stopped
and all utilities (electricity, compressed air) disconnected.
CAUTION!
Always discharge the fluid pressure in the valve and piping before
disassembling the valve.
CAUTION!
Burns hazard. The valves and piping may be very hot. Wear protective
gloves
18
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
2. CLEANING AWAY DEPOSITS:
- Thoroughly wash and clean all the valve parts before disassembly;
- Pay attention to any possible detergent or other aggressive fluid
deposits (see "Cleaning");
- Always use protective safety glasses and gloves when required.
CAUTION!
Hand crushing hazard. During operation there is a risk of crushing
inside the valve body in the area between the actuator and the valve
body.
9Cylinder
10Bush
14Sealing ring
17Bush
19Sealing ring
24Air connector
28Shutter nut
30Double shutter
33Clamp
34Screw
35Assembly
40Cap
42Upper body
45Steam barrier
47Sealing ring
50Gasket holder disc
51Lower shutter
57Sealing ring
92Intermediate body
94Sealing ring
108Sealing ring
120Bush
154Thickness
156Sealing ring
157Sealing ring
168Bush
212Shutter stem
213Sealing ring
274Sealing ring
275Sealing ring
276Sealing ring
277Sealing ring
50
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
24
40
10
276
17
277
275
274
(DN125-150)
7
19
9
(DN125-150)
6
(BBZR - BBYR)
(BBYP - BBYR)
120
50
50
157
156
A
33
7
42
157
156
CB
35
154
34 (DN10-100)
8 (DN125-150)
(BBYP - BBYR)
33
47
168
45
168
108
33
14
14
30
(P.T.F.E.)
212
14
30
14
28
EN-IST-BBZP-0418
47
57
1
51
Instruction, Use and Maintenance Manual
BBZP M8-LLL
2
14
33
B
51
33
94
213
33
42
108
BBZP M9-LLL
C
92
108
33
42
108
33
92
108
33
14
14
30
1
1
52
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
16
Disassembly of the BBZP - BBZR - BBZT- BBYP - BBYR BBYT Diverters
a
(BBZP - BBZR - BBZT - BBYP - BBYR - BBYT)
(54 - 58)
b
(BBZP M8-LLL)
EN-IST-BBZP-0418
(59 - 65)
53
Instruction, Use and Maintenance Manual
A
Disassembly of the BBZP - BBZR - BBZT- BBYP - BBYR BBYT Diverters
a
1
(Normally closed)
33
1
(Normally open or
double acting)
54
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
(BBZP M9-LLL)
c
1
c
2
92
33
1
c
3
92
108
33
(Normally closed)
(Normally open or
double acting)
EN-IST-BBZP-0418
55
Instruction, Use and Maintenance Manual
a
4
a
5
56
30
a
6
14
14
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
(P.T.F.E.)
e
5
30
e
6
14
28
e
7
212
EN-IST-BBZP-0418
14
57
Instruction, Use and Maintenance Manual
(BBYP - BBYR - BBYT)
a
8
d
8
42
50
33
a
9
50
33
42
42
58
108
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
B Disassembly of the BBZP M8-LLL Diverter
b
1
b
2
33
1
EN-IST-BBZP-0418
59
Instruction, Use and Maintenance Manual
b
3
213
b
4
51
94
b
5
b
6
92
108
60
33
92
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
b
7
(Normally closed)
(Normally open or
double acting)
42
33
EN-IST-BBZP-0418
61
Instruction, Use and Maintenance Manual
b
8
42
108
9
50
b
10
2
b
2
11
b
2
14
62
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
12
(BBYP - BBYR - BBYT)
d
12
50
156
13
13
120
50
157
d
50
156
15
d
14
50
157
45
d
16
45
57
d
33
47
47
45
17
d
168
45
168
EN-IST-BBZP-0418
63
Instruction, Use and Maintenance Manual
(DN125-150)
(BBZR - BBYR)
18
18
f
19
35
34
8
154
35
34
(BBZT - BBYT)
64
40
24
(82 - 94)
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
20
17
9
20
(DN 125-150)
i
7
21
22
10
275
10
274
276
17
21
7
i
19
9
6
EN-IST-BBZP-0418
277
65
Instruction, Use and Maintenance Manual
17
Assembly of the BB ZP - BBZR - BBZT- BBYP - BBYR BBYT Diverters
2
1
1
14
10
85°C
94
H O
2
66
abc
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
3
276
17
277
(DN 125-150)
i
3
19
9
4
5
275
10
274
6
i
4
7
9
EN-IST-BBZP-0418
7
67
Instruction, Use and Maintenance Manual
6
(BBZT - BBYT)
40
24
7
40
24
(BBZR - BBYR)
f
7
68
34
8
(DN125-150)
35
154
35
34
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
(BBYP - BBYR - BBYT)
d
8
168
45
168
d
11
d
9
47
45
47
d
12
10
d
45
57
1
2
1
45
33
EN-IST-BBZP-0418
69
Instruction, Use and Maintenance Manual
13
120
50
157
(BBYP - BBYR - BBYT)
d
13
14
14
15
1
50
156
1
d
15
1
d
70
157
50
50
1
156
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
a
(BBZP - BBZR - BBZT - BBYP - BBYR - BBYT)
(72 - 76)
b
EN-IST-BBZP-0418
(BBZP M8-LLL)
(77 - 81)
71
Instruction, Use and Maintenance Manual
A
Assembly of the BB ZP - BBZR - BBZT- BBYP - BBYR BBYT Diverters
(BBZP M9-LLL)
c
16
a
17
18
42
108
(BBYP - BBYR - BBYT)
d
a
18
92
108
42
50
2
33
50
42
2
33
72
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
(P.T.F.E.)
19
30
a
14
14
19
e
e
20
212
14
21
e
14
28
EN-IST-BBZP-0418
30
73
Instruction, Use and Maintenance Manual
22
a
23
a
74
(Normally closed)
(Normally open or
double acting)
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
24
a
25
a
2
33
1
92
(BBZP M9-LLL)
(Normally closed)
(Normally open or
double acting)
EN-IST-BBZP-0418
75
Instruction, Use and Maintenance Manual
(BBZP M9-LLL)
c
26
2
(BBZT - BBYT)
1
33
(82 - 94)
76
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
B Assembly of the BBZP M8-LLL Diverter
b
16
2
b
14
17
EN-IST-BBZP-0418
50
b
2
18
42
108
77
Instruction, Use and Maintenance Manual
b
19
20
b
2
42
33
(Normally closed)
(Normally open or
double acting)
78
21
b
92
108
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
22
b
23
b
213
51
94
2
b
24
33
92
(Normally closed)
EN-IST-BBZP-0418
(Normally open or
double acting)
79
Instruction, Use and Maintenance Manual
b
26
2
33
80
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
18 Pneumatic Valves BBZT - BBYT
NO.DESCRIPTION
23Upper pin
24Air connector
66Piston
88Grub screw
99Cylinder
129Pin
169Sealing ring
170Screw
171Sealing ring
172Sealing ring
173Buffer
175Bush
177Elastic wire
204Bush
EN-IST-BBZP-0418
81
Instruction, Use and Maintenance Manual
175
173
88
172
66
99
129
171
204
171
23
170
177
82
24
169
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
19 Disassembly of the BBZT - BBYT
12
34
177
EN-IST-BBZP-0418
83
Instruction, Use and Maintenance Manual
56
175
173
88
7
8
129
84
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
910
111213
66
171
EN-IST-BBZP-0418
66
204
172
66
171
85
Instruction, Use and Maintenance Manual
24
14
16
15
170
170
99
169
99
17
23
(35)
86
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
20 Assembly of the BBZT - BBYT
12
23
34
9999
169
EN-IST-BBZP-0418
87
Instruction, Use and Maintenance Manual
5
170
99
24
6
88
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
7
171
172
66
8
66
204
9
66
171
10
EN-IST-BBZP-0418
89
Instruction, Use and Maintenance Manual
11
12
13
129
90
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
14
88
1516
175
173
17
EN-IST-BBZP-0418
91
Instruction, Use and Maintenance Manual
1819
177
2021
92
EN-IST-BBZP-0418
Instruction, Use and Maintenance Manual
22
23
EN-IST-BBZP-0418
93
Instruction, Use and Maintenance Manual
FACSIMILE
21 Annexes
EC DECLARATION OF CONFORMITY
OF THE MACHINERY
(EC) 2006/42, Annex. II, p. 1 A
BARDIANI VALVOLE S.p.A.
Via G. di Vittorio 50/52 – 43045 Fornovo di Taro (Pr) – Italy
Declares
under its own responsibility that the machine:
GB - EC Declaration of
conformity - A3-P-PRG-GB
Type:
Model:
Serial number:
Function:
Year of construction:
Reference
complies with all relevant provisions of the following EC directives:
(EC) 2006/42 MACHINERY
and also comply with the following EC Directives and Regulations: