Bardiani BBZK, BBYK, BBWK, ZVF Instruction, Use And Maintenance Manual

Page 1
Instruction, Use and Maintenance Manual
MODULATING VALVE
Bardiani Valvole S.p.A.
via G. di Vittorio, 50/52 - 43045 Fornovo di Taro (PR) - Italy tel. +39 0525 - Fax 0525 3408 [email protected] - www.bardiani.com
EN-IST-BBZK-0418
Page 2
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
MANUAL REVISION DATE
2
Page 3
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
INDEX
1 Safety,Warning and Mandatory Signs 5 2 General safety warnings 8 3 Technical data 9 4 Checking / Unpacking / Lifting 10 5 Installation 11 6 Operation 13 7 Troubleshooting 14 8 Cleaning 15 9 General maintenance 16 10 Scheduled maintenance 18 11 Tools useful for Disassembly/Reassembly 19 12 Modulating valve BBZK - BBYK 20 13 Disassembly of the BBZK - BBYK 22 14 Assembly of the BBZK - BBYK 26 15 Modulating diaphragm valve BBWK 33 16 Disassembly of the BBWK 35 17 Assembly of the BBWK 38 18 Modulating valve BBZK - BBYK Diverter 44 19 Disassembly of the BBZK - BBYK Diverter 46 20 Assembly of the BBZK - BBYK Diverter 50 21 Annexes 57 22 2D diagram BBZK 58 23 2D diagram BBYK 59 24 2D diagram BBWK 60 25 2D diagram BBZK Diverter 61 26 2D diagram BBYK Diverter 62 27 Warranty 63 28 Recommendations 64
3
Page 4
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
INTRODUCTION
This “Instruction, Use and Maintenance Manual” has been prepared to provide guidance and recommendations to assist qualified skilled technicians in the understanding, running and maintenance orf the Products supplied.
It forms an integral part of the Products supplied and must be read prior to any installation, operation and/or maintenance of all types of valves provided.
This manual must be saved for future reference and be kept readily available at the unit.
With regards to the use of valves compliant with EU Directive 2014/34/UE (ATEX), consultation

The essential characteristics of all types of valves described herein being consistent, the Manufacturer reserves the right to alter and or complement and or update at any time and with no obligation to notify so in writing, the data and or information relevant to the use of the valves described in this "Instruction, Use and Maintenance Manual".
A constantly updated version of this "Instruction, Use and Maintenance Manual" is available at the Manufacturer's website www.bardianivalvole.it.
Under no circumstance shall the Manufacturer be held liable for consequences resulting from failure and or improper use of the instructions contained in this Manual and relating to the installation, operating, maintenance and storage of the products.
All rights reserved.
Full or part reproduction, transfer and or recording of any part of this "Instruction, Use and Maintenance Manual" by all means, whether it be electronic, on hard copy, mechanical or any other means or recording or reuse is strictly prohibited without the prior written consent of the Manufacturer and for any use other than that of the Buyer.
(Translation of the Original Instructions in the italian Language)
4
Page 5
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
1 Safety,Warning and Mandatory Signs
WARNING SIGNS
Pictogram Description Notes
WARNING General
This tells the person in question that the operation described involves (when not performed in accordance with the relative safety regulations) the risk of personal injury.
WARNING Hand crushing
Exercise caution in executing the procedure Hand crushing hazard
WARNING Heavy loads
Exercise caution in executing the procedure Heavy suspended loads.
WARNING Severe burns
Heat emission hazard Very hot surface, risk of severe burns
WARNING Risk of explosions
Take Care, risk of explosions
MANDATORY SIGNS (FOR THE OPERATOR IN CHARGE OF ASSEMBLY/DISASSEMBLY)
Pictogram Description Notes
OBLIGATION General
Special instructions must be followed to avoid injury to persons.
PROTECTIVE GLOVES
Safety gloves must be available for handling objects which could cause hand injuries.
HARD HAT
A hard hat must be worn during machine lifting operations to protect against hazards generated by suspended loads.
FOOTWEAR
Use safety footwear to protect against the risks of falling objects during operations to transport the machine.
SUITABLE CLOTHING
Suitable clothing such as overalls. It is strictly prohibited to wear clothes with large flapping sleeves and/or other loose items which could easily get caught up in machine parts.
5
Page 6
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
MANDATORY SIGNS (FOR THE OPERATOR IN CHARGE OF MECHANICAL MAINTENANCE)
Pictogram Description Notes
OBLIGATION General
Special instructions must be followed to avoid injury to persons.
PROTECTIVE GLOVES
Protective gloves must be available for handling objects which could cause hand injuries or when there is the possibility of coming into contact with harmful substances..
HARD HAT
Hard hats must be available when lifting heavy parts.
FOOTWEAR
Use safety footwear to protect against injuries caused by falling objects during maintenance operations (particularly when dismantling parts).
SUITABLE CLOTHING
Suitable clothing such as overalls. It is strictly prohibited to wear clothes with large flapping sleeves and/or other loose items which could easily get caught up in machine parts.
SAFETY GLASSES
Protective glasses must be available when there is the possibility of contact which harmful substances which could cause eye injuries.
OPERATING SIGNS
Pictogram Description Notes
SKILLED PERSONNEL
Dismantling/Assembling and maintenance operations must be carried out by expert technicians only.
NOTE
Follow the indicated note with care
ENVIRONMENTAL NOTE
Follow the regulations in force in the country of used governing waste disposal.
CLAMP
Use of a clamp
CLAMP WITH SOFT JAWS
Use of a clamp with jaws made from soft material
6
Page 7
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
OPERATING SIGNS
Pictogram Description Notes
PRESS
Use of a press
PRESS (release)
Use of a press Gradual release of the pressure force
ELECTRICAL CONNECTION
Electrical connection to the control unit (consult the relative instruction manual).
ELECTRICAL DISCONNECTION
Electrical disconnection from the control unit (consult the relative instruction manual).
PNEUMATIC CONNECTION
Connection of the air to the valve.
PNEUMATIC DISCONNECTION
Disconnection of the air from the valve
1
APPLICATION OF FOODSAFE GREASE
Use FOODLUBE HI-TEMP 2 15254 grease only
2
APPLICATION OF FOODSAFE GREASE
Use FOODLUBE Multi-paste 15756 grease only
APPLICATION OF MULTIPURPOSE GREASE
Use AGIP GREASE MU EP 2 SE 463754 only
THREADLOCK APPLICATION
Use SPEED BOND M500 threadlock only
OPTIONAL
7
Page 8
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
2 General safety warnings
Intended use
Bardiani valves have been designed exclusively for moving fluids.
Prohibited use
The valve must not be used:
• for any operations different to those described under the heading “Intended Use”,
• for handling fluids different to the type specified by the manufacturer;
• for moving fluids at different pressures to those envisaged by the manufacturer and indicated in the valve's technical data.
Limitations on valve use
It is forbidden to:
• use the valve in a construction configuration different to the one envisaged by the manufacturer.
• use the valve where there is a risk of explosion and/or fire, unless envisaged by the manufacturer (if the valves are certified in accordance with Directive 2014/34/EU, please refer to the ATEX Manual)-;
• integrate other systems and/or equipment which were not considered by the manufacturer during the executive design phase,
• use the valve for purposes other than those specifically envisaged by the manufacturer.
WARNING The machine may not he used inside premises where there is a potentially explosive atmosphere or

with Directive 2014/34/EU please refer to the ATEX Manual).
BARDIANI VALVOLE S.p.A. declines all liability for installation, use or maintenance which fails to comply with the indications provided in this manual!
8
Page 9
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
3 Technical data
VALVE DATA
Maximum pressure 10 bar Maximum seal pressure See catalogue
Servo-control pressure range
3 - 15 psi (0.21 - 1.05 bar) 6 - 18 psi (0.42 - 1.25 bar) 6 - 30 psi (0.42 - 2.07 bar) 9 - 32 psi (0.62 - 2.21 bar)
Material in contact with the product AISI 316L (1.4404). Check the resistance to corrosion in
relation to products and detergents
Gasket material in contact with the product
EPDM, FKM, HNBR, P.T.F.E. and other gaskets on request. Check compatibility with products and detergents
Surface finish in contact with the product
Ra 0.8 µm. Other finishes available on request
Pneumatic actuator stroke 15 - 20 mm
VAPOUR BARRIER DATA
Connectors 1/8” BSP Steam maximum temperature 130°C Gaskets FKM
GASKET MATERIALS COMPATIBILITY
Product EPDM FKM HNBR MVQ
Temperature (applications with air) -10 to
+140°C
-10 to +200°C -10 to +130°C -70 to +230°C
Caustic soda 2% 60°C 30°C To be checked Unsuitable Nitric Acid 2% 60°C 80°C To be checked Unsuitable Saturated steam 125°C Suitable To be
checked
Suitable Unsuitable
Greases Unsuitable Suitable Suitable Unsuitable Alcohols Suitable Unsuitable Suitable Suitable
The valve is complies with PED 2014/68/EU directive, with special reference to Annex III, Form A, concerning internal manufacturing checks as indicated in the Conformity Assessment Procedures.
The DN15--25 valves are included in compliance with Article 4, paragraph 3: Valves designed for use with gas, liquid gas, gases dissolved under pressure, steam and those liquids with a vapour pressure at maximum admissible temperature exceeding 0.5 bar at normal atmospheric pressure (1.013 mbar) within the following limits:
- For group 1 fluids when DN is from 25 to 100.
- For group 2 fluids when DN is 125 and over.
In the event of any doubt, please contact Bardiani Valvole S.p.A.
9
Page 10
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
4 Checking / Unpacking / Lifting
1. CHECK:
- Check the valve show no signs of damage caused during transport and that it corresponds with the order;
- Check the inside of the valve.
2. UNPACKING:
The valve packaging is made up of cardboard, wood and plastic. The valve is mainly made up of metal materials. The gaskets are usually made from elastomers. Disposal must be in compliance with local legislation.
3. VALVE LIFTING:
Take care as to the type of valve you are handling. Based on the size there are two different lifting procedures.
CAUTION!
Before lifting the valve, make sure there are no disassembled or separate valve parts which could fall off causing injury to persons and damage to the valve.
BBZK
Size
DN
Weight
Kg
10-25 A
40 A 50 A 65 A
80 B 100 B 125 B 150 B
Weight between 25 kg and
50 kg
Weight up to 25 kg
A
B
CAUTION!
The figures above are used purely to represent the methods and procedures for hoisting the valves. Bardiani Valvole S.p.A. declines all liability for any damage to things and/or injuries to persons caused by improper and/or incorrect hoisting of the valve.
10
Page 11
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
5 Installation
1. ELECTRICAL AND PNEUMATIC ENERGY SUPPLY
- Use expert personnel for installation/uninstallation operations;
- Check that the air pressure and quality are correct (see "Technical Data");
A = Pneumatic power supply
2. REDUCING THE STRESS TO WHICH THE VALVE IS SUBJECTED:
- Vibrations;
- Thermal expansion of the piping;
- Excessive welding;
- Overload.
CAUTION!
The seal seats may become deformed or cause valve malfunctioning.
3. CORRECT DIRECTION OF FLOW:
Flow in the opposite direction to valve closure minimizes water hammer.
CAUTION!
Bardiani Valvole S.p.A. declines all liability for any damage to things and/or injuries to persons caused by any failure to correctly follow the installation procedures.
11
A
Page 12
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
4. VALVE CONNECTIONS/CONNECTORS:
If the valve is fitted with connectors, you may proceed with installation. Correctly insert the gaskets and tighten the connectors
.
5. WELDING THE VALVE BODY ONTO PIPING:
Remove the body from the rest of the valve before proceeding with welding operations. Please refer to the following pages in this manual.
CAUTION!
Hand crushing hazard. During operation there is a risk of crushing inside the valve body in the area between the actuator and the valve body.
6. MINIMUM MAINTENANCE CLEARANCES:
Make sure there is enough room around the valve for it to be disassembled (with the control unit installed).
Valve dimension
(DN)
BBZK A
(mm)
BBYK A
(mm)
10-25 255 255
40 280 280 50 290 290 65 300 300 80 315 315
100 340 340
CAUTION!
Bardiani Valvole S.p.A. declines all liability for any damage to things and/or injuries to persons caused by any failure to correctly follow the installation procedures.
12
A
Page 13
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
6 Operation
1. VALVE INSPECTION BEFORE OPERATION:
- Supply air to the actuator;
- Open and close the valve several times;
- Check that the valve works correctly and accurately.
CAUTION!
Hand crushing hazard. During operation there is a risk of crushing inside the valve body in the area between the actuator and the valve body.
13
A
Page 14
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
7 Troubleshooting
PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION
External leak
Worn gasket Replace the seal
Leaks inside the closed valve caused by normal wear
External leak
Excessive pressure
Replace with a gasket of a different type of elastomer
Excessive temperature
Premature leaks inside the closed valve
Aggressive fluids
Modify the operating conditions
Too many commands active
Difficulty opening and closing
Incorrect type of elastomer used for the gaskets
Replace with a gasket of a different type of elastomer
Incorrect positioning of the actuator
Install the actuator correctly
Incorrect operation of the actuator
Switch from NC to NA or vice versa
Impurities in the actuator
Actuator inspection and maintenance
Incorrect valve body positioning
Disassemble and correctly reposition the valve body
14
Page 15
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
Risk of stainless steel corrosion
Risk of damage
elastomers
8 Cleaning
1. VALVE CLEANING WITH DETERGENTS:
The system in which the valve is installed must be cleaned by expert personnel in observance of the following:
- Abide by the indicated detergent concentration values;
- Observe the instructions provided by the detergent manufacturer.
- Always wear protective safety glasses and gloves.
IMPORTANT!
- Accurately dose detergents to avoid excessive concentration;
- Always rinse thoroughly with clean water after washing.
- Check compatibility of valve materials.
CAUTION!
Burns hazard. The valves and piping may be very hot. Wear protective gloves
WARNING
After installing a new or serviced valve, perform an internal washing cycle before using the piping for food liquids. If it there has been any welding work, passivation treatment must be carried out.
EXAMPLE OF INTERNAL WASHING CYCLE (CIP)
Phases Temperature °C Washing product
Initial rinse Environment Chlorine- and chloride-free
water
Washing 70 °C Caustic soda (NaOH) at 1%
Intermediate rinse Environment Chlorine- and chloride-free
water
Washing 70 °C Nitric acid (HNO3) at 0.5%
End rinse Environment Chlorine- and chloride-free
water
Recommended washing product velocity = 2m/s
15
Page 16
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
9 General maintenance
1. MAINTENANCE PRECAUTIONS
Maintenance operations must be carried out by expert technicians only.
CAUTION!
Maintenance operations must be carried out with the line stopped and all utilities (electricity, compressed air) disconnected.
CAUTION!
Always discharge the fluid pressure in the valve and piping before disassembling the valve.
CAUTION!
Burns hazard. The valves and piping may be very hot. Wear protective gloves
16
Page 17
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
2. CLEANING AWAY DEPOSITS:
- Thoroughly wash and clean all the valve parts before disassembly;
- Pay attention to any possible detergent or other aggressive fluid
deposits (see "Cleaning");
- Always use protective safety glasses and gloves when required.
CAUTION!
Hand crushing hazard. During operation there is a risk of crushing inside the valve body in the area between the actuator and the valve body.
3. REPLACEMENT OF WORN VALVE PARTS:
Always use original spare parts
17
Page 18
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
10 Scheduled maintenance
SCHEDULED MAINTENANCE VALVE GASKETS ACTUATOR GASKETS
Preventive Replace after 12 months Replace after 24 months
In the event of leaks Replace at the end of the day Replace in the event of leaks
Periodical
Check correct operation and
that there are no leaks
Check correct operation and
that there are no leaks
Record the actions carried out Record the actions carried out
18
Page 19
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
11 Tools useful for Disassembly/Reassembly
TOOLS
Soft
19
Page 20
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
12 Modulating valve BBZK - BBYK
NO. DESCRIPTION
1 Lower body
2 Shutter 14 Sealing ring 15 Yoke 24 Air connector 33 Clamp 45 Steam barrier 47 Sealing ring 50 Gasket holder disc 54 Ring nut 57 Sealing ring 77 Nut
120 Bush 122 Bush 127 Pneumatic actuator 156 Sealing ring 157 Sealing ring 168 Bush
20
Page 21
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
21
24
(BBYK)
127
54
122
15
120
157
156
50
157
156
50
77
2
14
33
1
47
168
45
168
47
57
33
(BBYK)
Page 22
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
13 Disassembly of the BBZK - BBYK
(Normally open)
(Normally closed)
22
1
33
1
Page 23
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
23
2
50
2
2
2
14
3
4
Page 24
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
24
168
45
168
47
45
47
45
57
(BBYK)
157
50
156
50
45
33
50
156
120
50
157
5 6
5
a
7
a
9
a
10
a
8
a
6
a
Page 25
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
25
1413
12
11
54
122
15
24
127
Page 26
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
14 Assembly of the BBZK - BBYK
26
85°C
H O
2
1
10
14
a b c
Page 27
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
27
1 2
3
122
15
54
5
4
2
127
Page 28
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
28
168
45
168
47
45
47
45
57
(BBYK)
45
33
6
a
7
a
8
a
9
a
10
a
1
1
2
Page 29
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
29
50
157
120
50
156
1
1
11 12 13
(BBYK)
157
50
156
50
11
a
12
a
13
a
1
1
Page 30
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
30
2
14
14
15
Page 31
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
(Normally open)
(Normally closed)
31
1
16
2
33
17
Page 32
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
32
0
5
10
15
20
18
Page 33
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
15 Modulating diaphragm valve BBWK
NO. DESCRIPTION
1 Lower body
2 Shutter 14 Sealing ring 15 Yoke 23 Pin 24 Air connector 33 Clamp 50 Gasket holder disc 54 Ring nut 77 Diaphragm ring nut
120 Bush 122 Bush 127 Pneumatic actuator 128 Diaphragm 205 Nut
33
Page 34
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
34
127
54
122
15
205
33
1
120
14
2
128
77
23
50
24
Page 35
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
16 Disassembly of the BBWK
(Normally open)
(Normally closed)
35
33
1
1
Page 36
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
36
2
23
77
128
2
3
50
120
4
2
2
14
5 6
Page 37
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
37
1413
12
11
54
122
15
24
127
Page 38
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
17 Assembly of the BBWK
38
85°C
H O
2
1
10
14
a b c
Page 39
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
39
1
2
3
122
15
54
5
4
2
127
Page 40
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
40
1
6
50
120
7 8
2
14
9
77
77
128
128
23
77
128
2
Page 41
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
41
10
Page 42
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
(Normally open)
(Normally closed)
42
11
1
33
2
12
Page 43
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
43
0
5
10
15
20
13
Page 44
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
18 Modulating valve BBZK - BBYK Diverter
NO. DESCRIPTION
1 Lower body 14 Sealing ring 15 Yoke 23 Pin 24 Air connector 30 Double shutter 33 Clamp 42 Upper body 45 Steam barrier 47 Sealing ring 50 Gasket holder disc 54 Ring nut 57 Sealing ring 77 Nut
108 Sealing ring 120 Bush 122 Bush 127 Pneumatic actuator 156 Sealing ring 157 Sealing ring 168 Bush
44
Page 45
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
45
(BBYK)
127
54
122
15
120
157
156
50
157
156
50
77
47
168
45
168
47
57
33
(BBYK)
42
33
108
30
14
33
1
24
Page 46
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
19 Disassembly of the BBZK - BBYK Diverter
(Normalmente aperta)
(Normalmente chiusa)
(Normally open)
(Normally closed)
46
1
1
33
Page 47
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
47
4
32
30
42
50
33
42
108
30
5
6
14
14
Page 48
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
48
50
156
120
50
157
5 6
168
45
168
47
45
47
45
57
(BBYK)
157
50
156
50
45
33
5
a
7
a
9
a
10
a
8
a
6
a
Page 49
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
49
1413
12
11
54
122
15
24
127
Page 50
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
20 Assembly of the BBZK - BBYK Diverter
50
85°C
H O
2
1
10
14
a b c
Page 51
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
51
1 2
3
122
15
54
5
4
2
127
Page 52
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
52
168
45
168
47
45
47
45
57
(BBYK)
45
33
6
a
7
a
8
a
9
a
10
a
1
1
2
Page 53
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
53
50
157
120
50
156
1
1
11 12 13
(BBYK)
157
50
156
50
11
a
12
a
13
a
1
1
Page 54
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
54
42
108
42
50
33
14 15
30
16 17
14
14
2
Page 55
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
(Normalmente aperta)
(Normalmente chiusa)
(Normally open)
(Normally closed)
55
18
1
19
33
2
Page 56
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
56
0
5
10
15
20
20
Page 57
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
21 Annexes
BARDIANI VALVOLE S.p.A..
Via G. di Vittorio 50/52
43045 Fornovo di Taro (Pr)
GB - EC Declaration of conformity - A3-P-PRG-GB
A3-P-PRG-GB Ed. 1. Rev. 0
EC DECLARATION OF CONFORMITY
OF THE MACHINERY
(EC) 2006/42, Annex. II, p. 1 A
BARDIANI VALVOLE S.p.A.
Via G. di Vittorio 50/52 – 43045 Fornovo di Taro (Pr) – Italy
Declares
under its own responsibility that the machine:
Type:
P
P
NNEEUUMMAATTIICCVVAALLVVEES
S
Model: Serial number: Function:
Fluid handling
Year of construction:
2016
Reference
complies with all relevant provisions of the following EC directives:
(EC) 2006/42 MACHINERY
and also comply with the following EC Directives and Regulations:
(EU) 2014/30 ELECTROMAGNETIC COMPATIBILITY DIRECTIVE (EMC)
and the following harmonized standards, rules and / or technical specifications applied:
EN ISO 12100:2010
REGULATION (EC) 1935/2004 and subsequent amendments and additions with regard to steel and elastomers in contact with the product
REGULATION (EC) 10/2011 and subsequent amendments and additions with regard to PTFE in contact with the product
Fornovo di Taro 10/10/2016 ______________________________
Emanuela Bardiani
Legal representative
FACSIMILE
57
Page 58
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
22 2D diagram BBZK
58
20
Page 59
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
23 2D diagram BBYK
59
20
Page 60
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
24 2D diagram BBWK
60
35
Page 61
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
25 2D diagram BBZK Diverter
61
48
Page 62
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
26 2D diagram BBYK Diverter
62
48
Page 63
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
27 Warranty
1. VALIDITY
Bardiani Valvole‘s Products are manufactured in compliance with the technical specifications laid out in their “Instruction, Use and Maintenance Manual” and are fully compliant with the directives specifically mentioned in these manuals. Bardiani Valvole S.p.A. guarantees its own Products against any design and/or construction and/or material defects and/or faults for a period of 12 (twelve) months from the date of delivery. Notification of any Product defects and/or faults must be sent in writing to Bardiani Valvole S.p.A. within 8 (eight) days from their detection, providing adequate documentation of the defect/fault encountered as evidence. Services provided in the warranty period shall not result in an extension of the warranty beyond the stipulated 12 (twelve)-month period, as this warranty validity period is to be considered mandatory.
2. CONTENTS OF THE WARRANTY
Notwithstanding and without prejudice to the rights of the Buyer, which may be acknowledged by applicable law, this warranty it to be intended as limited, at the discretion of Bardiani Valvole S.p.A., to the repair and/or replacement of the Product and/or part of the Product and/or its components which is/are found to be defective due to design and/or manufacturing and/or material faults. In the event of repair and/or replacement of the Product and/or any one of its parts and/or components, any returned item/s shall become the property of Bardiani Valvole S.p.A. and the relative shipping costs shall charged to Bardiani Valvole S.p.A. Bardiani Valvole S.p.A., shall be under no obligation to compensate for any immaterial and/or indirect damages and shall in no way be held liable for consequential damages and/or losses, such as (by way of example only), damages due to loss of business, contracts, opportunities, time, production, profits, goodwill, image etc. No retailer or distributor or dealer or agent or representative or employee or person appointed by Bardiani Valvole S.p.A. is authorized to make any amendments and/or integrations and/or extensions to
this warranty.
3. WARRANTY EXCLUSIONS
- Elastomers and electrical components are expressly excluded from this warranty.
- This warranty does not cover design faults emerging whenever a Product is manufactured by Bardiani Valvole S.p.A. based on designs and/or technical specifications provided by the Buyer.
- Moreover this warranty excludes the following:
- faults and/or defects resulting from incorrect and/or unsuitable and/or inadequate transportation of the Product;
- faults and/or defects resulting from failure to comply with the indications laid out in the “Instruction, Use and Maintenance Manual” with regards to installation of the Product or in any event caused by incorrect and/or unsuitable and/or improper installation;
- faults and/or defects resulting from failure to comply with indications laid out in the “Instruction, Use and Maintenance Manual” with regards to use and/or maintenance operations and/or storage of the Product or in any event caused by incorrect and/or unsuitable and/or improper use and/or maintenance operations and/or storage;
- faults and/or defects due to normal wear and tear of the Product and/or its parts and/or its components;
- faults and/or defects in the Product and/or its parts and/or its components for work and/or repairs being carried out by unskilled staff or staff that has not been authorised by Bardiani Valvole S.p.A.;
- faults and/or defects in the Product and/or its parts and/or its components due to it/them being dropped and/or banged and/or dented and/or misused and/or tampering and/or breakage and/or accidents or in any event due to negligence and/or carelessness and/or neglect by the Buyer and in general for any causes not attributable to design and/or manufacturing and/or material defects;
- faults and/or defects in the Product and/or its parts and/or its components caused by other events beyond the control of Bardiani Valvole S.p.A., such as force majeure or unforseeable circumstances.
63
Page 64
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
28 Recommendations
1.Consultation of the "Instruction, Use and Maintenance Manual” is mandatory prior to the installation,
use and maintenance of the products of all Products. All the information, indications, specifications, technical details provided herein are based on test data which the Manufacturer Bardiani Valvole S.p.A. holds to be reliable nevertheless the above is not deemed to be assumed as fully exhaustive inasmuch as not every possible use has been envisaged.
2.All the illustrations and drawings provided are to be intended as indicative and therefore not binding,
the illustrations being for presentation purposes only.
3.It is the Buyer's duty to assess the suitability of the products for the use he intends to make of the
same prior to placing the order as he/she will take the risks and accept liability in case of incorrect choice and use of the Products.
4.The Manufacturer strongly recommends the Buyer to contact their sales team and request any
information that might be needed in relation to the specifications and uses of the Products.
5.The information provided in this manual refers to the standard products manufactured by Bardiani
Valvole S.p.A. and therefore cannot be assumed to apply to customized products as well.
6.Bardiani Valvole S.p.A. reserves the right to amend and/or integrate and/or update the data and/
or information and/or technical details relative to Products at any time and without prior notice. Please visit the website www.bardiani.com, where the latest updated of the "Instruction, Use and Maintenance Manual" can be found".
7.The content and validity of the warranty covering the Products of Bardiani Valvole S.p.A are dealt with
in the relevant section in the “Instruction, Use and Maintenance Manual” which constitutes an integral part of the Products themselves.
8.Bardiani Valvole S.p.A., shall not in any way be held liable for immaterial, indirect and consequential
damages, such as (by way of example only), damages or loss of business, contracts, opportunities, time, production, profits, goodwill, image etc..
64
Page 65
Instruction, Use and Maintenance Manual
EN-IST-BBZK-0418
NOTES
65
Page 66
Bardiani Valvole S.p.A.
via G. di Vittorio, 50/52 - 43045 Fornovo di Taro (PR) - Italy
tel. +39 0525 400044 - fax +39 0525 3408
bardiani@bardiani.com - www.bardiani.com