Bardiani B925, B925B, B925V, B925A Instruction, Use And Maintenance Manual

Instruction, Use and Maintenance Manual
MIXPROOF VALVE
Bardiani Valvole S.p.A.
via G. di Vittorio, 50/52 - 43045 Fornovo di Taro (PR) - Italy tel. +39 0525 - Fax 0525 3408 bardiani@bardiani.com - www.bardiani.com
EN-IST-B925-0218
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
MANUAL REVISION DATE
2
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
INDEX
1 Safety,Warning and Mandatory Signs 5 2 General safety warnings 8 3 Technical data 9 4 Checking / Unpacking / Lifting 10 5 Installation 11 6 Operation 14 7 Troubleshooting 15 8 Cleaning 16 9 General maintenance 17 10 Scheduled maintenance 19 11 Tools useful for Disassembly/Reassembly 20 12 Mixproof valve B925 - B925B - B925V - B925A 21 13 Disassembly of the B925 - B925B - B925V - B925A 24 14 Assembly of the B925 - B925B - B925V - B925A 39 15 Mixproof valve B925 - B925B Diverter 54 16 Disassembly of the B925 - B925B Diverter 56 17 Assembly of the B925 - B925B Diverter 69 18 Annexes 85 19 2D diagram B925 86 20 2D diagram B925B 87 21 2D diagram B925 Diverter 88 22 2D diagram B925B Diverter 89 23 2D diagram B925V 90 24 2D diagram B925A 91 25 Warranty 92 26 Recommendations 93
3
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
INTRODUCTION
This “Instruction, Use and Maintenance Manual” has been prepared to provide guidance and recommendations to assist qualified skilled technicians in the understanding, running and maintenance orf the Products supplied.
It forms an integral part of the Products supplied and must be read prior to any installation, operation and/or maintenance of all types of valves provided.
This manual must be saved for future reference and be kept readily available at the unit.
With regards to the use of valves compliant with EU Directive 2014/34/UE (ATEX), consultation

The essential characteristics of all types of valves described herein being consistent, the Manufacturer reserves the right to alter and or complement and or update at any time and with no obligation to notify so in writing, the data and or information relevant to the use of the valves described in this "Instruction, Use and Maintenance Manual".
A constantly updated version of this "Instruction, Use and Maintenance Manual" is available at the Manufacturer's website www.bardianivalvole.it.
Under no circumstance shall the Manufacturer be held liable for consequences resulting from failure and or improper use of the instructions contained in this Manual and relating to the installation, operating, maintenance and storage of the products.
All rights reserved.
Full or part reproduction, transfer and or recording of any part of this "Instruction, Use and Maintenance Manual" by all means, whether it be electronic, on hard copy, mechanical or any other means or recording or reuse is strictly prohibited without the prior written consent of the Manufacturer and for any use other than that of the Buyer.
(Translation of the Original Instructions in the italian Language)
4
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
1 Safety,Warning and Mandatory Signs
WARNING SIGNS
Pictogram Description Notes
WARNING General
This tells the person in question that the operation described involves (when not performed in accordance with the relative safety regulations) the risk of personal injury.
WARNING Hand crushing
Exercise caution in executing the procedure Hand crushing hazard
WARNING Heavy loads
Exercise caution in executing the procedure Heavy suspended loads.
WARNING Severe burns
Heat emission hazard Very hot surface, risk of severe burns
WARNING Risk of explosions
Take Care, risk of explosions
MANDATORY SIGNS (FOR THE OPERATOR IN CHARGE OF ASSEMBLY/DISASSEMBLY)
Pictogram Description Notes
OBLIGATION General
Special instructions must be followed to avoid injury to persons.
PROTECTIVE GLOVES
Safety gloves must be available for handling objects which could cause hand injuries.
HARD HAT
A hard hat must be worn during machine lifting operations to protect against hazards generated by suspended loads.
FOOTWEAR
Use safety footwear to protect against the risks of falling objects during operations to transport the machine.
SUITABLE CLOTHING
Suitable clothing such as overalls. It is strictly prohibited to wear clothes with large flapping sleeves and/or other loose items which could easily get caught up in machine parts.
5
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
MANDATORY SIGNS (FOR THE OPERATOR IN CHARGE OF MECHANICAL MAINTENANCE)
Pictogram Description Notes
OBLIGATION General
Special instructions must be followed to avoid injury to persons.
PROTECTIVE GLOVES
Protective gloves must be available for handling objects which could cause hand injuries or when there is the possibility of coming into contact with harmful substances..
HARD HAT
Hard hats must be available when lifting heavy parts.
FOOTWEAR
Use safety footwear to protect against injuries caused by falling objects during maintenance operations (particularly when dismantling parts).
SUITABLE CLOTHING
Suitable clothing such as overalls. It is strictly prohibited to wear clothes with large flapping sleeves and/or other loose items which could easily get caught up in machine parts.
SAFETY GLASSES
Protective glasses must be available when there is the possibility of contact which harmful substances which could cause eye injuries.
OPERATING SIGNS
Pictogram Description Notes
SKILLED PERSONNEL
Dismantling/Assembling and maintenance operations must be carried out by expert technicians only.
NOTE
Follow the indicated note with care
ENVIRONMENTAL NOTE
Follow the regulations in force in the country of used governing waste disposal.
CLAMP
Use of a clamp
CLAMP WITH SOFT JAWS
Use of a clamp with jaws made from soft material
6
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
OPERATING SIGNS
Pictogram Description Notes
PRESS
Use of a press
PRESS (release)
Use of a press Gradual release of the pressure force
ELECTRICAL CONNECTION
Electrical connection to the control unit (consult the relative instruction manual).
ELECTRICAL DISCONNECTION
Electrical disconnection from the control unit (consult the relative instruction manual).
PNEUMATIC CONNECTION
Connection of the air to the valve.
PNEUMATIC DISCONNECTION
Disconnection of the air from the valve
1
APPLICATION OF FOODSAFE GREASE
Use FOODLUBE HI-TEMP 2 15254 grease only
2
APPLICATION OF FOODSAFE GREASE
Use FOODLUBE Multi-paste 15756 grease only
APPLICATION OF MULTIPURPOSE GREASE
Use AGIP GREASE MU EP 2 SE 463754 only
THREADLOCK APPLICATION
Use SPEED BOND M500 threadlock only
OPTIONAL
7
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
2 General safety warnings
Intended use
Bardiani valves have been designed exclusively for moving fluids.
Prohibited use
The valve must not be used:
• for any operations different to those described under the heading “Intended Use”,
• for handling fluids different to the type specified by the manufacturer and indicated in the valve's technical data;
• for moving fluids at different pressures to those envisaged by the manufacturer and indicated in the valve's technical data.
Limitations on valve use
It is forbidden to:
• use the valve in a construction configuration different to the one envisaged by the manufacturer.
• use the valve where there is a risk of explosion and/or fire, unless envisaged by the manufacturer (if the valves are certified in accordance with Directive 2014/34/EU, please refer to the ATEX Manual)-;
• integrate other systems and/or equipment which were not considered by the manufacturer during the executive design phase,
• use the valve for purposes other than those specifically envisaged by the manufacturer.
WARNING The machine may not he used inside premises where there is a potentially explosive atmosphere or

with Directive 2014/34/EU please refer to the ATEX Manual).
BARDIANI VALVOLE S.p.A. declines all liability for installation, use or maintenance which fails to comply with the indications provided in this manual!
8
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
3 Technical data
VALVE DATA
Maximum pressure PN10 Maximum seal pressure 10 bar (145 psi) Minimum pressure Vacuum Storage temperature from -10°C to 25°C Material in contact with the product AISI 316L (1.4404). Check the resistance to corrosion in
relation to products and detergents
Gasket material in contact with the product
EPDM, FKM, HNBR and other gaskets on request. Check compatibility with products and detergents
Surface finish in contact with the product
Ra 0.8 µm. Other finishes available on request
Auxiliary washing circuit (B925B) connections
¼” BSP Male M14x1.5 Male for Ø8 pipe ½” Clamp
VAPOUR BARRIER DATA
Connectors 1/8” BSP Steam maximum temperature 130°C (266°F) Gaskets material FKM
PNEUMATIC ACTUATOR STRUCTURE DATA
Connectors 1/8” BSP Pipe dimensions 6 mm external diameter, 4 mm internal diameter Air pressure from 6 bar (87 psi) to 8 bar (116 psi) Air quality Class 2, 4, 3 ISO8573-1 External material AISI 304L (1.4307) Seals NBR Noise levels 76 dB Electrical supply See Giotto Top
GASKET MATERIALS COMPATIBILITY
Product EPDM FKM HNBR
Temperature (applications with air) -10 to +140°C -10 to +200°C -10 to +130°C Caustic soda 2% 60°C 30°C To be checked Nitric Acid 2% 60°C 80°C To be checked Saturated steam 125°C Suitable To be checked Suitable Greases Unsuitable Suitable Suitable Alcohols Suitable Unsuitable Suitable
The valve is conformed to PED 2014/68/EU directive, with special reference to Annex III, Module A, concerning internal manufacturing checks as indicated in the Conformity Assessment Procedures.
The DN15--25 valves are included in compliance with Article 4, paragraph 3: Valves designed for use with gas, liquid gas, gases dissolved under pressure, steam and those liquids with a vapour pressure at maximum admissible temperature exceeding 0.5 bar at normal atmospheric pressure (1.013 mbar) within the following limits:
- For group 1 fluids when DN is from 25 to 100.
- For group 2 fluids when DN is 125 and over.
In the event of any doubt, please contact Bardiani Valvole S.p.A.
9
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
Weight between 25 kg and
50 kg
Weight over 50 Kg
4 Checking / Unpacking / Lifting
1. CHECK:
- Check the valve show no signs of damage caused during transport and that it corresponds with the order;
- Check the inside of the valve.
2. UNPACKING:
The valve packaging is made up of cardboard, wood and plastic. The valve is mainly made up of metal materials. The gaskets are usually made from elastomers. Disposal must be in compliance with local legislation.
3. VALVE LIFTING:
Take care as to the type of valve you are handling. Based on the size there are two different lifting procedures.
CAUTION! Before lifting the valve, make sure there are no disassembled or separate valve parts which could fall off causing injury to persons and damage to the valve.
Size
DN
Weight
Kg
15--50 A 65--80 B
100--125 C
CAUTION!
The figures above are used purely to represent the methods and procedures for hoisting the valves. Bardiani Valvole S.p.A. declines all liability for any damage to things and/or injuries to persons caused by improper and/or incorrect hoisting of the valve.
Weight up to 25 kg
10
A B C
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
Valve
Mixproof
Diverter
Valve
Mixproof
5 Installation
1. ELECTRICAL AND PNEUMATIC ENERGY SUPPLY
- Use expert personnel for installation/uninstallation operations;
- Check that the air pressure and quality are correct (see "Technical Data");
- Check the power supply to the control unit is correct (consult the relative instruction manual).
1 = Opening 2 = Top lift 3 = Bottom lift
2. REDUCING THE STRESS TO WHICH THE VALVE IS SUBJECTED:
- Vibrations;
- Thermal expansion of the piping;
- Excessive welding;
- Overload.
CAUTION!
The seal seats may become deformed or cause valve malfunctioning.
3. CORRECT DIRECTION OF FLOW:
Flow in the opposite direction to valve closure minimizes water hammer.
CAUTION!
Bardiani Valvole S.p.A. declines all liability for any damage to things and/or injuries to persons caused by any failure to correctly follow the installation procedures.
11
3
1
2
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
4. VALVE CONNECTIONS/CONNECTORS:
If the valve is fitted with connectors, you may proceed with installation. Correctly insert the gaskets and tighten the connectors
.
5. WELDING THE VALVE BODY ONTO PIPING:
1. Insert air couplings in the central connector
2. Remove the body from the rest of the valve before proceeding with welding operations.
CAUTION!
Hand crushing hazard. During operation there is a crushing hazard caused by the washing pin or the guide pin (when present).
12
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
6. MINIMUM MAINTENANCE CLEARANCES:
Make sure there is enough room around the valve for it to be disassembled (with the control unit installed).
DN
15÷40
B925 B925 DIVERTER
A (mm) B (mm) C (mm)
15÷32 350 150 330
40 370 130 350 50 400 165 380 65 420 180 420
80 450 195 450 100 570 235 570 125 670 280 680 150 670 280 680
7. ORIENTATION OF THE DOUBLE BODY:
Pay attention to body orientation. On the double body and the bottom body (for valves with separate bodies) the UP arrow indicates the position of the valve actuator.
CAUTION!
Bardiani Valvole S.p.A. declines all liability for any damage to things and/or injuries to persons caused by any failure to correctly follow the installation procedures.
13
A
B
C
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
6 Operation
1. EXTERNAL CIP CONNECTION (B925B only)
A = CIP external inlet A = CIP external outlet
CAUTION!
Hand crushing hazard. During operation there is a crushing hazard caused by the washing pin or the guide pin (when present).
2. VALVE INSPECTION BEFORE OPERATION:
- Supply air to the actuator;
- Power the valve (via the control unit);
- Open and close the valve several times;
- Check that the valve works correctly and accurately.
1 = Opening 2 = Top lift 3 = Bottom lift
CAUTION!
Hand crushing hazard. During operation there is a crushing hazard caused by the washing pin or the guide pin (when present).
14
A
B
3
1
2
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
7 Troubleshooting
PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION
External leak
Worn gasket Replace the seal
Leaks inside the closed valve caused by normal wear
External leak
Excessive pressure
Replace with a gasket of a different type of elastomer
Excessive temperature
Premature leaks inside the closed valve
Aggressive fluids
Modify the operating conditions
Too many commands active
Difficulty opening and closing
Incorrect type of elastomer used for the gaskets
Replace with a gasket of a different type of elastomer
Incorrect positioning of the actuator
Install the actuator correctly
Impurities in the actuator
Actuator inspection and maintenance
Incorrect valve body positioning
Disassemble and correctly reposition the valve body
15
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
Risk of stainless steel corrosion
Risk of damage elastomers
8 Cleaning
1. VALVE CLEANING WITH DETERGENTS:
The system in which the valve is installed must be cleaned by expert personnel in observance of the following:
- Abide by the indicated detergent concentration values;
- Observe the instructions provided by the detergent manufacturer.
- Always wear protective safety glasses and gloves.
IMPORTANT!
- Accurately dose detergents to avoid excessive concentration;
- Always rinse thoroughly with clean water after washing.
- Check compatibility of valve materials.
CAUTION! Burns hazard. The valves and piping may be very hot. Wear protective gloves
WARNING After installing a new or serviced valve, perform an internal washing cycle before using the piping for food liquids. If it there has been any welding work, passivation treatment must be carried out.
EXAMPLE OF INTERNAL WASHING CYCLE (CIP)
Phases Temperature °C Washing product
Initial rinse Environment Chlorine- and chloride-free
water
Washing 70 °C Caustic soda (NaOH) at 1%
Intermediate rinse Environment Chlorine- and chloride-free
water
Washing 70 °C Nitric acid (HNO3) at 0.5%
End rinse Environment Chlorine- and chloride-free
water
Recommended washing product velocity = 2m/s
16
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
9 General maintenance
1. MAINTENANCE PRECAUTIONS
Maintenance operations must be carried out by expert technicians only.
CAUTION!
Maintenance operations must be carried out with the line stopped and all utilities (electricity, compressed air) disconnected.
CAUTION!
Always discharge the fluid pressure in the valve and piping before disassembling the valve.
CAUTION!
Burns hazard. The valves and piping may be very hot. Wear protective gloves
17
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
2. CLEANING AWAY DEPOSITS:
- Thoroughly wash and clean all the valve parts before disassembly;
- Pay attention to any possible detergent or other aggressive fluid deposits (see "Cleaning");
- Always use protective safety glasses and gloves when required.
CAUTION!
Hand crushing hazard. During operation there is a crushing hazard caused by the washing pin or the guide pin (when present). Never put hands in the valve openings.
3. REPLACEMENT OF WORN VALVE PARTS:
Always use original spare parts
18
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
10 Scheduled maintenance
SCHEDULED MAINTENANCE VALVE GASKETS ACTUATOR GASKETS
Preventive Replace after 12 months Replace after 24 months
In the event of leaks Replace at the end of the day Replace in the event of leaks
Periodical
Check correct operation and
that there are no leaks
Check correct operation and
that there are no leaks
Record the actions carried out Record the actions carried out
19
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
11 Tools useful for Disassembly/Reassembly
TOOLS
Soft
20
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
12 Mixproof valve B925 - B925B - B925V - B925A
NO. DESCRIPTION NO. DESCRIPTION
1 Bottom body/double body 2 Upper shutter 70 Sealing ring 4 Sealing ring 74 Air connector
9 Cylinder 75 Air connector 11 Pin 77 Nut 12 Sealing ring 78 Sealing ring 13 Central piston 81 Sealing ring 14 Sealing ring 82 Sealing ring 16 Sealing ring 83 Sealing ring 17 Bush 85 Secondary spring 18 Buffer 90 Sealing ring 19 Sealing ring 91 Sealing ring 24 Air connector 92 Intermediate body 31 Spring 93 Intermediate valve member 33 Clamp 94 Sealing ring 34 Screw 96 Sealing ring 35 Assembly 101 Screw 40 Cap 106 Bush 42 Upper body 108 Sealing ring 44 Sealing ring 120 Bush 45 Steam barrier 121 Sealing ring 47 Sealing ring 126 Sealing ring 50 Gasket holder disc 154 Thickness 51 Lower shutter 168 Bush 52 Cap 193 Bush 53 Lower piston 199 Clamp 55 Sealing ring 226 Sealing ring 58 Drive sleeve 240 Sealing ring 60 Sealing ring 242 Sealing ring 61 Sealing ring 245 Guide pin 62 Sealing ring 270 Sealing ring 63 Sealing ring 64 Bush 66 Upper piston 69 Sealing ring
Legend:
00* = component present only on the B925B valve. 00** = component present only on the B925 valve. 00*** = component present only on the DN25 - 40 and DN65 valve. = component present in the spring block (supplied assembled)
21
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
22
285
284
19 17
18
16
77
91
66
11
12
120
50
106
34
70
60
240*
2
14
62
121
90
31
154***
13
4
83
58
82
53
61
81
35
245**
245*
270*
40
85
9
24
24
101
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
23
47
197
52
64
197
69
126
199
33
42
108
33
1
1
94
193
78**
242*
51
64
69
126
52
45
168
47
226
33
(B925V)
(B925V)
55
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
13 Disassembly of the B925 - B925B - B925V - B925A
24
33
1
285
284
2
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
25
(B925V)
3
a
3
d
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
26
4
5
193
51
51
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
27
7
8
51
242
(B925B)
51
94
51
51
78
(B925)
6
a
6
b
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
28
9
10
24
24
245
270
(B925B)
(B925B)
11
a
12
a
11
b
245
(B925B)
245
(B925)
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
29
106
50
70
50
60
50
14
15
16
2
50
13
a
13
d
(B925V)
2
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
30
(B925V)
45
33
45
55
226
45
47
45
47
45
168
14
d
15
d
16
d
17
d
18
d
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
31
2
2
240
(B925B)
19
20
21
23
22
2
2
14
2
62
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
32
42
108
24 25
33
1
42
199
1
52
26
a
26
d
199
1
52
(B925V)
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
33
64
52
69
52
126
52
64
52
69
52
126
52
197
197
27
a
27
d
28
d
28
a
29
a
29
d
(B925V)
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
34
30
31
101
85
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
35
85
32
33
34
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
36
11
12
35 36 37
38 39
4
91
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
37
18
17
18
19
18
16
9
34
40 41 42
43 44
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
38
83
58
82
53
61
53
120
35
121
35
81
35
45
46
47 48 49
50 51 52
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
14 Assembly of the B925 - B925B - B925V - B925A
1
1
1
39
85°C
H O
2
2
1
a
b
c
14
62
94
51
2
10
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
40
51
242
(B925B)
51
78
(B925)
2
14
2
62
3
4
5
94
51
193
51
6
8
2
240
(B925B)
7
a
7
b
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
41
126
52
69
52
64
52
1
1
9
a
10
a
11
a
12
a
126
52
197
197
69
52
64
52
10
d
11
d
12
d
1
1
(B925V)
9
d
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
42
81
35
120
35
121
35
60
50
70
50
106
50
17
19
18
1
14
a
15
a
16
a
13
a
45
55
226
45
47
45
47
168
13
d
14
d
15
d
16
d
(B925V)
1
1
1
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
43
20
61
53
82
53
21 22 23
35
83
58
25 26
27
24
28
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
44
32
33
4
91
9
34
29 30
9
31
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
45
34
35
36
37
11
12
38
85
39
40
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
46
18
16
18
19
18
17
41
42 43
44
45
18
101
46
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
47
2
50
2
50
47
d
48
d
47
a
48
a
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
48
245
(B925)
245
(B925B)
245
270
(B925B)
(B925B)
49
a
50
a
49
b
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
49
24
40
24
51
52
1
51
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
50
199
1
52
33
33
199
53
56
2
2
2
54 55
42
108
1
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
51
33
1
42
57
58
1
199
1
52
57
d
(B925V)
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
52
33
60
59
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
53
285
284
61
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
15 Mixproof valve B925 - B925B Diverter
NO. DESCRIPTION NO. DESCRIPTION
1 Bottom body/double body 77 Nut 2 Upper shutter 78 Sealing ring 4 Sealing ring 81 Sealing ring
9 Cylinder 82 Sealing ring 11 Pin 83 Sealing ring 12 Sealing ring 85 Secondary spring 13 Central piston 90 Sealing ring 14 Sealing ring 91 Sealing ring 16 Sealing ring 92 Intermediate body 17 Bush 93 Intermediate valve member 18 Buffer 94 Sealing ring 19 Sealing ring 96 Sealing ring 24 Air connector 101 Screw 31 Spring 106 Bush 33 Clamp 108 Sealing ring 34 Screw 120 Bush 35 Assembly 121 Sealing ring 40 Cap 126 Sealing ring 42 Upper body 154 Thickness 44 Sealing ring 193 Bush 50 Gasket holder disc 199 Clamp 51 Lower shutter 240 Sealing ring 52 Cap 242 Sealing ring 53 Lower piston 245 Guide pin 58 Drive sleeve 270 Sealing ring 60 Sealing ring 61 Sealing ring 62 Sealing ring 63 Sealing ring 64 Bush 66 Upper piston 69 Sealing ring 70 Sealing ring 74 Air connector 75 Air connector
54
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
Legend:
00* = component present only on the B925B valve. 00** = component present only on the B925 valve. 00*** = component present only on the DN25 - 40 and DN65 valve.
= component present in the spring block (supplied assembled)
55
92
44
42
108
33
33
1
19 17
18
16
77
91
66
11
12
33
63
94
96
51
193
93
78**
242*
64
69
126
52
120
50
106
34
70
60
240*
2
14
62
121
90
31
154***
13
4
83
58
82
53
61
81
35
245**
245*
270*
40
85
9
24
74
75
101
199
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
16 Disassembly of the B925 - B925B Diverter
56
1
33
1
285
284
2
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
57
3
51
4
33
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
58
93
6
5
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
59
94
51
14
193
93
93
96
78
(B925)
93
(B925B)
242
93
87
12
13
9
10
11
51
93
63
93
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
60
15
16
75
24
74
245
270
(B925B)
(B925B)
16
a
17
a
16
b
245
(B925B)
245
(B925)
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
61
106
50
70
50
60
50
18
19
20
21
2
50
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
62
2
2
240
(B925B)
22
23
24
26
25
2
2
14
2
62
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
63
42
108
27 28
31 32 33
64
52
69
52
126
52
33
92
42
92
44
3029
52
33
1
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
64
34
35
101
85
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
65
85
36
37
38
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
66
11
12
39 40 41
42 43
4
91
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
67
18
17
18
19
18
16
9
34
44 45 46
47 48
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
68
83
58
82
53
61
53
120
35
121
35
81
35
49
50
51 52 53
54 55 56
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
17 Assembly of the B925 - B925B Diverter
69
a
b
c
1
1
1
1
2
1
14
62
94
63
51
2
85°C
H O
2
10
93
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
70
2
14
2
62
3 4
5
2
240
(B925B)
98
93
(B925B)
242
78
(B925)
93
193
93
6
63
93
96
10
94
51
7
a
7
b
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
71
81
35
120
35
121
35
60
50
70
50
106
50
15
16 17 18
19 2120
1
1
126
52
69
52
64
52
1
1
11 12
14
13
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
72
22
61
53
82
53
23 24 25
83
58
27
26
28
35
29
30
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
73
34
35
4
91
31
9
9
34
32
33
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
74
36
37
38
39
11
12
85
40 41
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
75
18
16
18
19
18
17
43
44
45
46
42
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
76
47
18
101
48
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
77
50
49
2
50
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
78
245
(B925)
245
(B925B)
245
270
(B925B)
(B925B)
51
a
52
a
51
b
75
40
74
24
53
54
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
79
33
33
33
199
5655
93
2
2
2
2
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
80
33
42
92
61
1
42
108
92
44
60
58
57
59
1
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
81
62
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
82
63
64
51
33
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
83
33
199
1
52
66
65
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
84
67
285
284
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
18 Annexes
BARDIANI VALVOLE S.p.A..
Via G. di Vittorio 50/52
43045 Fornovo di Taro (Pr)
GB - EC Declaration of conformity - A3-P-PRG-GB (2)
A3-P-PRG-GB Ed. 1. Rev. 0
EC DECLARATION OF CONFORMITY
OF THE MACHINERY
(EC) 2006/42, Annex. II, p. 1 A
BARDIANI VALVOLE S.p.A.
Via G. di Vittorio 50/52 – 43045 Fornovo di Taro (Pr) – Italy
Declares
under its own responsibility that the machine:
Type:
P
P
NNEEUUMMAATTIICCVVAALLVVEES
S
Model: Serial number: Function:
Fluid handling
Year of construction:
2016
Reference
complies with all relevant provisions of the following EC directives:
(EC) 2006/42 MACHINERY
and also comply with the following EC Directives and Regulations:
(EU) 2014/30 ELECTROMAGNETIC COMPATIBILITY DIRECTIVE (EMC)
and the following harmonized standards, rules and / or technical specifications applied:
EN ISO 12100:2010
REGULATION (EC) 1935/2004 and subsequent amendments and additions with regard to steel and elastomers in contact with the product
REGULATION (EC) 10/2011 and subsequent amendments and additions with regard to PTFE in contact with the product
Fornovo di Taro
28/04/2016 ______________________________
Emanuela Bardiani
Legal representative
FACSIMILE
85
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
19 2D diagram B925
86
Doppio corpo unico
Corpi orientabili
24
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
20 2D diagram B925B
87
Doppio corpo unico
Corpi orientabili
24
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
21 2D diagram B925 Diverter
88
54
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
22 2D diagram B925B Diverter
89
54
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
23 2D diagram B925V
90
24
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
24 2D diagram B925A
91
24
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
25 Warranty
1. VALIDITY
Bardiani Valvole‘s Products are manufactured in compliance with the technical specifications laid out in their “Instruction, Use and Maintenance Manual” and are fully compliant with the directives specifically mentioned in these manuals. Bardiani Valvole S.p.A. guarantees its own Products against any design and/or construction and/or material defects and/or faults for a period of 12 (twelve) months from the date of delivery. Notification of any Product defects and/or faults must be sent in writing to Bardiani Valvole S.p.A. within 8 (eight) days from their detection, providing adequate documentation of the defect/fault encountered as evidence. Services provided in the warranty period shall not result in an extension of the warranty beyond the stipulated 12 (twelve)-month period, as this warranty validity period is to be considered mandatory.
2. CONTENTS OF THE WARRANTY
Notwithstanding and without prejudice to the rights of the Buyer, which may be acknowledged by applicable law, this warranty it to be intended as limited, at the discretion of Bardiani Valvole S.p.A., to the repair and/or replacement of the Product and/or part of the Product and/or its components which is/are found to be defective due to design and/or manufacturing and/or material faults. In the event of repair and/or replacement of the Product and/or any one of its parts and/or components, any returned item/s shall become the property of Bardiani Valvole S.p.A. and the relative shipping costs shall charged to Bardiani Valvole S.p.A. Bardiani Valvole S.p.A., shall be under no obligation to compensate for any immaterial and/or indirect damages and shall in no way be held liable for consequential damages and/or losses, such as (by way of example only), damages due to loss of business, contracts, opportunities, time, production, profits, goodwill, image etc. No retailer or distributor or dealer or agent or representative or employee or person appointed by Bardiani Valvole S.p.A. is authorized to make any amendments and/or integrations and/or extensions to
this warranty.
3. WARRANTY EXCLUSIONS
- Elastomers and electrical components are expressly excluded from this warranty.
- This warranty does not cover design faults emerging whenever a Product is manufactured by Bardiani Valvole S.p.A. based on designs and/or technical specifications provided by the Buyer.
- Moreover this warranty excludes the following:
- faults and/or defects resulting from incorrect and/or unsuitable and/or inadequate transportation of the Product;
- faults and/or defects resulting from failure to comply with the indications laid out in the “Instruction, Use and Maintenance Manual” with regards to installation of the Product or in any event caused by incorrect and/or unsuitable and/or improper installation;
- faults and/or defects resulting from failure to comply with indications laid out in the “Instruction, Use and Maintenance Manual” with regards to use and/or maintenance operations and/or storage of the Product or in any event caused by incorrect and/or unsuitable and/or improper use and/or maintenance operations and/or storage;
- faults and/or defects due to normal wear and tear of the Product and/or its parts and/or its components;
- faults and/or defects in the Product and/or its parts and/or its components for work and/or repairs being carried out by unskilled staff or staff that has not been authorised by Bardiani Valvole S.p.A.;
- faults and/or defects in the Product and/or its parts and/or its components caused by its being dropped and/or banged and/or dented and/or misused and/or tampering and/or breakage and/or accidents and/or any other event caused by negligence and/or carelessness and/or neglect by the Buyer and in general for any causes not ascribable to design and/or manufacturing and/or material defects;
- faults and/or defects in the Product and/or its parts and/or its components caused by other events beyond the control of Bardiani Valvole S.p.A., such as force majeure or unforseeable circumstances.
92
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
26 Recommendations
1.Consultation of the "Instruction, Use and Maintenance Manual” is mandatory prior to the installation,
use and maintenance of the products of all Products. All the information, indications, specifications, technical details provided herein are based on test data which the Manufacturer Bardiani Valvole S.p.A. holds to be reliable nevertheless the above is not deemed to be assumed as fully exhaustive inasmuch as not every possible use has been envisaged.
2.All the illustrations and drawings provided are to be intended as indicative and therefore not binding,
the Products illustrations being for presentation purposes only.
3.It is the Buyer's duty to assess the suitability of the products for the use he intends to make of the
same prior to placing the order as he/she will take the risks and accept liability in case of incorrect choice and use of the Products.
4.The Manufacturer strongly recommends the Buyer to contact their sales team and request any
information that might be needed in relation to the specifications and uses of the Products.
5.The information provided in this manual refers to the standard products manufactured by Bardiani
Valvole S.p.A. and therefore cannot be assumed to apply to customized products as well.
6.Bardiani Valvole S.p.A. reserves the right to amend and/or integrate and/or update the data and/
or information and/or technical details relative to Products at any time and without prior notice. Please visit the website www.bardiani.com, where the latest updated of the "Instruction, Use and Maintenance Manual" can be found".
7.The content and validity of the warranty covering the Products of Bardiani Valvole S.p.A are dealt with
in the relevant section in the “Instruction, Use and Maintenance Manual” which constitutes an integral part of the Products themselves.
8.Bardiani Valvole S.p.A., shall not in any way be held liable for immaterial, indirect and consequential
damages, such as (by way of example only), damages or loss of business, contracts, opportunities, time, production, profits, goodwill, image etc..
93
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
NOTES
94
Instruction, Use and Maintenance Manual
EN-IST-B925-0218
NOTES
95
Bardiani Valvole S.p.A.
via G. di Vittorio, 50/52 - 43045 Fornovo di Taro (PR) - Italy
tel. +39 0525 400044 - fax +39 0525 3408
bardiani@bardiani.com - www.bardiani.com
Loading...