Bardac SL Series, SLE Seriesv Data Sheet

powerSL Series
Analog DC drives - up to 75 hp
The powerSL Series of dc drives incorporate the well proven SLX, SL & SLE 3-phase basic OEM chassis drives into a compact package, complete with high speed 3-phase power fuses, armature fuses (SLX & SL models only), control power fuses, contactor, and other features.
Easy access to all internal power components and terminals is achieved in a compact, elegant package which, at 75hp is as small as a 81/2” x 11” note pad and is less than 101/2” deep!
powerSLX Series … 4-Q regenerative, reversing DC systems drive with field controller powerSL Series … Non-reversing DC systems drive with field controller powerSLE Series … Non-reversing DC OEM drive.
Standard Features
SL SLX SLE
• • Field controller with automatic field weakening
• Configurable field bridge
• • • Heat sink thermostat protection
• • Diagnostic test socket
• • • 50/60Hz autoranging
• • • Power supply range: 208-240 or 380-480 volts +/-10%
• • • Auxiliary control power input: 115 volts 50/60Hz.
• • • Phase rotation insensitivity
• • • Linear torque control
• • • Armature voltage or tach feedback
• • • Calibration range switches (no component change)
• • • Speed reference +/-10V or 4-20mA
• • • Speed trim input
• • • Maximum and minimum speed settings
• • • Adjustable up & down ramps
• • • Adjustable current limit
• • • Current range selectable for multiple horsepower’s
• • • Torque control
• • • 150% overload capacity with 30 second stall timer
• • • Relay outputs: Stall, Zero speed, Overload
• • Regen stop (SLX 4-quad. regen drive)
• • • Setpoint ramp reset
• • • Start inhibit after power loss
LED indicators:
• • • Stall Stall Timer
• • +/- Current Field Loss
• • Tach Loss Peak Amps
• • • Ext. Trip Power On
• • 25%, 50%, 95% Field Volts
• • • Speed signal output
• • • Current signal output
• • • Ramp & Total demand signal outputs
• • • Shunt wound or permanent magnet motors
• • • Stability adjustment
• • Current reduction for low power test
Protection & Control
• • • Control fuses
• • • 3-Phase high speed semiconductor fuses
• • • Armature high speed semiconductor fuse
• • • Main AC line contactor
SLE44/106, 60hp DC Drive
SL Series Non-Regen DC Drives & SLX Series 4Q Regen DC Drives
powerDRIVE basicDRIVE 500VDC 240VDC Armature Line reactor Drive Isolation Model Model Arm Arm Current Transformer
powerSL & SLX15 SL & SLX15 20hp 10hp 36 amps LM37 DIT27** powerSL & SLX20 SL & SLX20 30hp 13hp 51 amps LM52 DIT40** powerSL & SLX40 SL & SLX40 60hp 25hp 99 amps LM120 DIT75** powerSL & SLX50 SL & SLX50 75hp 35hp 122 amps LM120 DIT93**
Field current controlled up to 5 amps Dimensions: basicDRIVE 9.8” high x 8” wide x 5.6” deep (248mm x 203mm x 143mm) Dimensions: powerDRIVE 11” high x 8” wide x 10.4” deep (280mm x 203mm x 265mm)
SLE Series … Non-reversing OEM drive
powerDRIVE basicDRIVE 500VDC 240VDC Armature Line reactor Drive Isolation Model Model Arm Arm Current Transformer
powerSLE14 SLE14 20hp 10hp 34 amps LM37 DIT27** powerSLE24 SLE24 30hp 15hp 58 amps LM52 DIT40** powerSLE34 SLE34 50hp 20hp 82 amps LM82 DIT63** powerSLE44 SLE34 60hp 30hp 106 amps LM120 DIT75**
Field current up to 2.5 amps Dimensions: basicDRIVE 11.5” high x 8.5” wide x 6.1” deep (290mm x 215mm x 155mm) Dimensions: powerDRIVE 11.5” high x 8.5” wide x 9.4” deep (290mm x 215mm x 240mm)
powerSLX50/122, 75hp regen DC Drive
Power Quality For DC Drives
Drive Isolation Transformers
Standard specification:
NEMA 1 enclosed for indoor use K-factor 4 Windings: Delta Primary, Wye Secondary Aluminum or Copper windings as indicated Taps at ± 5% Approvals: UL, C-UL
Options
Outdoor enclosures Frequencies other than 60Hz Voltages other than 230/460/575 pri, 230/460 sec Special Taps Fungus Proofing 80°C & 115°C Rise Copper Windings Electrostatic Shield K-13, K-20, K-30
Discount Schedule SX-1
Model Specification
DIT3** 3KVA - Cu (2hp) DIT6** 6KVA - Cu (5hp) DIT11** 11KVA - Al (7.5hp) DIT14** 14KVA - Al (10hp) DIT20** 20KVA - Al (15hp) DIT27** 27KVA - Al (20hp) DIT34** 34KVA - Al (25hp) DIT40** 40KVA - Al (30hp) DIT51** 51KVA - Al (40hp) DIT63** 63KVA - Al (50hp) DIT75** 75KVA - Al (60hp) DIT93** 93KVA - Al (75hp) DIT118** 118KVA - Al (100hp) DIT145** 145KVA - Al (125hp) DIT175** 175KVA - Al (150hp) DIT220** 220KVA - Al (200hp DIT275** 275KVA - Al (250hp) DIT330** 330KVA - Al (300hp) DIT440** 440KVA - Al (400hp) DIT550** 550KVA - Al (500hp) DIT660** 660KVA - Al (600hp)
Line Reactors For 3-Phase DC Drives
Model hp. at hp. at Arm Dimensions Mount Holes Weight Number 230V 460V Amps W x D x H H x W LBS
LM18 5 10 20 6.0”x4.8”x3.1” 2.1”x2.0” 9 LM37 10 20 41 7.2”x5.6”x3.4” 2.3”x3.0” 11 LM52 15 30 58 7.2”x5.6”x3.8” 2.6”x3.0” 14 LM67 20 40 75 9.0”x7.0”x4.8” 3.2”x3.0” 23 LM82 25 50 91 9.0”x7.0”x4.8” 3.2”x3.0” 24 LM120 35 75 133 10.8”x8.2”x5.6” 3.5”x3.6” 43 LM150 40 100 166 10.8”x8.3”x5.6” 3.5”x3.6” 47 LM195 60 125 216 9.0”x7.1”x4.9” 3.2”x3.0” 29 LM240 75 150 266 10.8”x8.4”x5.8” 3.2”x3.6” 40 LM300 200 333 10.8”x8.4”x6.0” 4.2”x3.6” 48 LM375 100 250 416 10.8”x8.2”x7.3” 4.2”x3.6” 68 LM480 150 300 533 14.8”x14.0”x10.2” 5.9”x4.6” 125 LM600 400 666 15.5”x14.0”x11.5” 6.8”x4.6” 155 LM750 200 500 833 15.5”x14.0”x13.0” 6.8”x4.6” 180 LM900 600 1000 15.5”x14.0”x15.5” 9.3”x4.6” 290 LM1125 750 1250 22.0”x20.0”x14.8” 9.5”x7.2” 400
Line Filter
LF3 Line Filter
LF3-FK Line Filter Fuse Kit