E2 Single Phase
VFD for Shaded Pole or Permanent Split Capacitor Motors up to 1.5HP
CONCEPT VERSATILE
IP20 or NEMA 12
Basic or smart drive
Solo or networked
Bardac
drive technology
THE NEW E2 SP Expandable Easy Economical Enduring
Efcient
OPTIDRIVE E2 SP
Single Phase Motor Controller
A unique VFD for variable torque, fan and pump type applications
The innovative E2 SP, Single Phase motor controller, uses a unique control algorithm that ensures reliable starting and control of either single or mulitple motors in low starting torque applications.
These drives are designed only for use on Shaded Pole (SP) or
Permanent Split Capacitor (PSC) type motors in variable torque, fan and centrigugal pump applications.
They use high frequency switching to provide near silent running which is most desireable in applications such as:
• Commercial and residential HVAC
• Fume extraction
• Laboratories
• Quiet locations.
THE BASICS Compact packaging Simple mechanical and electrical installation 50°C ambient rating 150% rating for 60 seconds, 175% for 2 seconds Simple basic set up Integral brake transistor (size 2, 100% rated) ModbusRTU serial port Remote keypad and display option OPTISTICK plug in unit for fast up/down load of parameters
Like the other E2 products the SP is expandable, versatile and economical in all its forms:
Basic or NEMA12 versions
Basic or full featured systems drive Basic or peer-to-peer networking over Ethernet
SPECIFICATION Output Frequency 0 to 500Hz Supply options Frequency 48 - 62 Hz Volts/Phases 100 - 132 volts max, single phase (0.5 - 1.0HP) 180 - 264 volts max, 1-phase (0.5 - 1.5HP) Environment Temperature Operating, -10 to 50°C max, storage, -40 to 60°C Altitude 0-2000M, derate 1% per 100M above 1000M Humidity up to 95%, non condensing Ingress Basic IP20, Optional IP55 (NEMA12) Control Mode V/F PWM Hz 4 to 32KHz (effective) V/Hz ratio Linear Boost Automatic boost phase operation Stop modes Coast / ramp / DC brake Setpoint ref 0-10VDC, 4-20mA, 0-20mA, Keypad, Modbus Presets 8 preset speeds PI control Direct & analog input trim Spin start Starts safely into rotating motor Accel/Decel 0 - 600 secs + Ramp stop decel 0 - 600 secs Congurable i/o Input 1 Programmable digital input Input/output 2 Selectable digital input / output Input 3 Congurable analog or digital input Input 4 Congurable analog or digital input Output 1 Congurable analog or digital output Relay 1 Normally open relay contact 30VDC 5A, 250VAC 6A Protection Drive trip Over/under volts, over current, external trip, Motor Overload, over temp, short circuit, ground fault Trip memory Last 4 trips stored