Bardac OPTIDRIVE E2 Sales Brochure

OPTIDRIVE E2
Industrial AC Drives up to 15HP IP20 and NEMA 12 Options Single & 3-phase motor versions
Bardac
drive technology
THE NEW E2 Expandable Easy Economical Enduring
Efcient
OPTIDRIVE E2
A general purpose drive with all purpose features
Basic or NEMA 12 (IP55)
Basic or full featured systems drive Basic or peer-to-peer networking over Ethernet
Basic or loaded, the new E2 is designed to give you the very best in value, performance and ease of use. The innovative design incorporates exibility, expandability and convenience that will work in many different applications throughout your plant.
The basic concept is simple and easy but you have all the options you will need to enhance the drive to a full featured, integrated systems drive.
THE BASICS
Compact packaging Simple mechanical and electrical installation 50°C ambient rating 150% rating for 60 seconds, 175% for 2 seconds Simple 14 parameter basic set up Integral RFI lter option Integral brake transistor, sizes 2 & 3 (100% continuous rated) ModbusRTU serial port Remote keypad and display option OPTISTICK plug in unit for fast up/down load of parameters
SPECIFICATION Output Frequency 0 to 500Hz Supply options Frequency 48 - 62 Hz Voltage/Phases 100 - 132 volts max, single phase (0.5 - 1.5HP) 180 - 264 volts max, 1-phase (0.5 - 3HP) 180 - 264 volts max, 3-phase (0.5 - 5HP) 342 - 528 volts max, 3-phase (1 - 15HP) Environment Temperature Operating, -10 to 50°C max, storage, -40 to 60°C Altitude 0-2000M, derate 1% per 100M above 1000M Humidity up to 95%, non condensing Ingress Protection Basic IP20, Optional IP55 (NEMA12) Control Mode Voltage vector PWM frequency 4 to 32KHz (effective) V/Hz ratio Linear Boost Yes Stop modes Coast / ramp / DC brake Skip frequency One point, adjustable frequency band Setpoint reference 0-10VDC, 4-20mA, 20-4mA, 0-20mA, Keypad, Modbus Preset speeds 8 PI control Direct & analog input trim Spin start Starts safely into rotating motor Accel/Decel 0 - 600 seconds + Ramp stop decel 0 - 600 seconds Congurable i/o Input 1 Programmable digital input Input 2 Programmable digital input Input 3 Congurable analog or digital input Input 4 Congurable analog or digital input Output 1 Congurable analog or digital output Output 2 Normally open relay contact 30VDC 5A, 250VAC 6A Protection Drive trip Over/under volts, over current, external trip, Motor Overload, over temperature, short circuit, ground fault Trip memory Last 4 trips stored