INSTALLATION INSTRUCTIONS
COMMERCIAL ROOM VENTILATORS
WITH EXHAUST
MODELS
CRVS-3
CRVP-3
CRVP-3L
For Use with Bard 1-1/2 through 3 Ton
Wall Mount Air Conditioners
and Heat Pumps
Bard Manufacturing Company, Inc.
Bryan, Ohio 43506
Since 1914...Moving ahead just as planned.
Manual : 2100-448E
Supersedes: 2100-448D
File: Volume III Tab 19
Date: 03-09-10
Manual 2100-448E
Page 1 of 13

CONTENTS
General
General Information........................................... 3
Unpacking.......................................................... 3
Description......................................................... 3
Installation
Basic Installation.............................................4-8
Blade Adjustment for Desired Ventilation Air..... 9
Commercial Room Ventilator –
W**A, W**H & W**L Series.............................. 12
Figures
Figure 1 Removal of Exterior Panels ............... 4
Figure 2 Removal of Exhaust Cover Plate ....... 5
Figure 3 Re-Routing Wires Left Hand Units..... 6
Figure 4 Inserting Ventilator Into Unit............... 7
Figure 5 CRV Wiring Diagram.......................... 9
Figure 6 Call for Blower Operation................. 12
Figure 7 Call for Cooling Operation................ 13
Tables
Table 1 ........................................................... 4
Graphs
S26H1 & S31H1 High Speed .......................... 10
S26H1 & S31H1 Low Speed ........................... 10
W30A/H/L & W36A/H/L High Speed................ 11
W30A/H/L & W36A/H/L Low Speed................. 11
BARD MANUFACTURING COMPANY, INC.
Manual 2100-448E
Page 2 of 13
BRYAN, OHIO USA 43506

GENERAL
GENERAL INFORMATION
The ventilator should only be installed by a trained
heating and air conditioning technician. These
instructions serve as a guide to the technician installing
the ventilator package. They are not intended as a step
by step procedure with which the mechanically inclined
owner can install the package.
The ventilator housing is shipped in one carton which
contains the electrical harness, miscellaneous hardware
and installation instructions.
UNPACKING
Upon receipt of the equipment be sure to compare the
model number found on the shipping label with the
accessory identification information on the ordering and
shipping document to verify that the correct accessory
has been shipped.
Inspect the carton housing of each ventilator as it is
received, and before signing the freight bill, verify that
all items have been received and that there is no visible
damage. Note any shortages or damage on all copies of
the freight bill. The receiving party must contact the
last carrier immediately, preferably in writing,
requesting inspection by the carrier’s agent. Concealed
damage not discovered until after loading must be
reported to the carrier within 15 days of its receipt.
DESCRIPTION
The CRVS-3, CRVP-3 and CRVP-3L ventilators are
designed to be used with Bard 1½ through 3 ton wall
mount series heat pumps and air conditioners. They are
electromechanical vent systems designed to provide
fresh air to meet indoor air quality standards.
MODELS:
When installed in the above listed models, the CRV
provides built in exhaust provisions. When the damper
blade opens to bring fresh air in, the damper also opens
an exhaust relief. The exhaust air will flow into the
condenser section of the unit. The condenser fan will
help draw exhaust air out.
Manual 2100-448E
Page 3 of 13

INSTALLATION
BASIC INSTALLATION
1. Unpack the ventilator assembly which includes the
integral ventilator with attached electrical harness
and miscellaneous hardware.
WARNING
Open and lock unit disconnect switch before
installing this accessory to prevent injury or
death due to electrical shock or contact with
moving parts. Turn thermostat to off.
REMOVAL OF EXTERIOR PANELS
FIGURE 1
TABLE 1
HTIWESUROF
LEDOM
H03W
SVRC3PVRC3-
L3-PVRC
2. Remove and save the existing exterior blower
access and service access panels on the Bard wall
mount unit. (See Figure 1.)
A03W
A63W
H63W
H62S
H13S
STINUGNIWOLLOF
L03W
L63W
Manual 2100-448E
Page 4 of 13