Barco nv
Noordlaan 5, B-8520 Kuurne
Phone: +32 56.36.82.11
Fax: +32 56.36.883.86
Support: www.barco.com/en/support
Visit us at the web: www.esterline.com
Printed in Belgium
Page 3
Changes
Barco provides this manual ’as is’ without warranty of any kind, either expressed or implied, including but not limited to the implied warranties or m erchantability and fitness for a particular purpose. Barco may make improvements and/or changes to the product(s) and/or the
program(s) described in this publication at any time without notice.
This publication could contain technical inaccuracies or typographical errors. Changes are periodically made to the information in this
publication; these changes are incorporated in new editions of this publication.
The latest edition of Barco manuals can be downloaded from the Barco web site w
All rights reserved. No part of this document may be copied, reproduced or translated. It shall not otherwise be recorded, transmitted or
stored in a retrieval system without the prior written consent of Barco.
EN55022/CISPR22 Class A ITE (Information Technology Equipment)
Class A ITE is a category of all other ITE which satisfies the class A ITE limits but not the class B ITE limits. Such equipment should not
be restricted in its sale but the following warning s hall be included in the instructions for use:
Warning : This is a class A product. In a dom estic environment this product may cause radio interference in which case the use r may be
required to take adequate measures. Contact the installer.
Federal Communications Commission (FCC Statement)
This equipment has been tested and found to c omply with the limits for a class A digital device, pur
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a comm ercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may c ause harmful interference to radio co
cause harmful interference, in which case the user will be responsible for correcting any interference. Contact the installer.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to ope rate the
equipment
mmunications. Operation of this equipment in a residential area may
suant to Part 15 of the FCC rules.
Guarantee and Compensation
Barco provides a guarantee relating to perfect manufacturing as part of the legally stipulated terms of guar antee. On re ceipt, the purchaser
must im mediately inspect all delivered goods for damage incurred during transport, as well as for material and manufacturing faults Barco
must be informed immediately in writing of any complaints.
The pe riod of guarantee begins on the date of transfer of risks, in the c ase of special systems and software on the date of commissioning,
at latest 30 days after the transfer of risks. In the event of justified notice of com plaint, Barco can repair the fault or provide a replacement
at its own discretion within an appropriate period. If this measure proves to be impossible or unsuccessful, the purchaser can demand a
reduction in the purchase pr ice or cancellation of the contract. All other claims, in par ticular those relating to compensation for direct or
indirect damage, and also damage attributed to the operation of software as well as to other services provided by Barco, being a component
of the system or independent service, will be deemed invalid provided the damage is not proven to be attributed to the absence of properties
guaranteed in writing or due to the intent or gross negligence or part of Barco.
If the purchaser or a third party carries ou
in particular if the systems are operated incorrectly or if, after the transfer of risks, the goods are subject to influences not agreed upon in
the contract, all guarantee claims of the purchaser will be rendered invalid. Not included in the guarantee coverage are system failures
which are attributed to programs or spe
maintenance are not subject to the guarantee provided by Barco either.
The environmental conditions as well as the servicing and maintenance regulations specified in this manual must be com p lied with by the
customer.
t modifications or repairs on goods delivered by Barco, or if the goods are ha ndled inc orrectly,
cial electronic circuitry provided by the purchaser, e.g. interfaces. Normal wear as well a s normal
Software License Agreement
You should carefully read the following terms and conditions before using this software. Your use of t his software indicates your acceptance
of this license agreement and warranty.
Terms and Conditions:
1.No redistribution of the software is allowed.
2.Reverse-Engineering. You may not reverse engineer, decompile, disassemble or alter this software product.
Disclaimer of Warranty:
This software and the accompanying files are sold “as is” and without warranties as to performance or merchantability or any other warranties whether expressed or implied. In no event shall Barco be liable for damage of any kind, loss of data, loss of profits, business
Page 4
interruption or other pecuniary loss arising directly or indirectly. Any liability of the seller will be exclusively limited to replacement of the
product or refund of purchase price.
GNU-GPL code
If you would like a copy of the GPL source code contained in this product shipped to you on CD, please contact B arco. The cost of pre paring
and mailing a CD will be charged.
Trademarks
Brand and product names mentioned in this manual may be trademarks, registered trademarks or copyrights of their respective holders.
All brand and product names mentioned in this manual serve as commen ts or examples and are not to be understood as advertising for
the products or their manufacturers.
Read this ch apter attentively. It contains important information to prevent personal injury while installing and using your Prometheus.
Furthermore, it includes several cautions to prevent damage to your P rometheus. Ensure that you understand and follow all safety
guidelines, safety instructions and warnings mentioned in this chapter before installing and using the Prometheus.
Clarification of the term “Prometheus series” used in this document
When referring in this document to the term “Prometheus series” means that the content is applicable for following Barco products:
•Prometheus I
•Prometheus II
1. Safety
Barco provides a guarantee relating to perfect manufacturing as part of the legally stipulated terms of guarantee. Observing the specification mentioned in this chapter is critical for projector perform
this can result in loss of warranty.
Model certification name
Model certification name:
•Prometheus I: DP4K-23B
•Prometheus II: DP4K-32B
Overview
•General considerations
•Safety training to be provided by the installer
•Important safety instructions
•Light beam Hazard Distance (HD)
•HD in function of the lens Throw Ratio (TR)
ance. Neglecting
R5905963 PROMETHEUS SERIES 09/03/2015
3
Page 8
1. Safety
1.1General considerations
WARNING: E nsure you understand and follow all the safety guidelines, safety in structions, warnings and
cautions mentioned in this manual.
WARNING: Be aware of suspended loads.
WARNING: Wear a hard hat to reduce the risk of personal injury.
WARNING: Be careful while working with heavy loads.
WARNING: Mind your fingers while working with heavy loads.
CAUTION: High p ressure lamp may explode if improperly handled.
General safety instructions
•Before operating this equipment please read this manual thoroughly and retain it for future reference.
•Installation and preliminary adjustments shall be performed by qualified B arc o per sonnel or by authorized Barco service dealers.
•All warnings on the projector and in the doc umentation manuals should be adhered to.
•All instructions for oper ating and use of th is equipment must be fo llowed precisely.
•All local installation codes should be adhered to.
Notice on safety
This equipment is built in accordance with the requirements
UL60950-1 and CAN/CSA C22.2 No.60950-1, w hich are the safety standards of information technology equipment including
electrical business equipmen t. These s afety standards impose important requirements on the use of safety critical components,
materials and insulation, in order to protect the user or
to live parts. Safety standards also impose limits to the internal and external temperature rises, radiation levels, mec hanical stability
and strength, enclosure construction and protection against the risk of fire. Simulated single fault condition testing ensures the
safety of the equipment to the user even when the equi
operator against risk o f electric s hock and energy hazard and having access
pment’s normal operation fails.
of the international safety standards IEC60950-1, EN60950-1,
Owner’s record
The part number and serial number are printed on a label which is stuck on the respective part. Record these numbers in the spaces
provided below. Refer to them whenever you call upon your Barco dealer regarding this product.
Product article number
Product serial number
Dealer
4R5905963 PROMETHEUS SERIES 09/03/2015
Page 9
1.2Safety training to be provided by the installer
WARNING: The installer is responsible that the user is instructed. The user will sign a document to confi rm
that the instructions have been received and understood.
Users definition
The Prometheus is intended for persons who have been instructed and trained by a skilled person (installer or service pers onnel)
to identify energy sources that may cause injury and to take precautions to avoid unintentional contact with or exposure to those
energy sources.
The skilled person must instruct the user about:
•High intensity light beam. The user must respect the exclusion zone, based on the light beam Hazard Distance (HD).
•Dangerous energy sources inside the projector. The user is not allowed to remove any cover from the projector.
•Small glass parts can leave the projector in the event of lamp explosion. Keep 1 m (40 in.) distance from the air outlet side of
the projector during operation.
•The installation, maintenance or service is for skilled persons only.
•The requirements for a restricted access location and an exclusion zone.
Restricted access location
To protect untrained persons and children, the projector must be installed in a restricted access location. The definition of a
restricted access location is a location for equipment where both of the following paragraphs app ly:
•Access can only be gained by skilled persons (installer or service personnel) or persons who have been instructed and trained
by a skilled person. The persons m ust have been ins tructed about the reasons for the restriction applied to the location and
about the precautions that shall be taken.
•Access is only possible through the use of the tool or lock and key, or other means of s ecurity, and is controlled by the authority
responsible for the location.
1. Safety
Exclusion zone
The projector radiates heat on its external surfaces and from ventilation ducts during normal operation. Exposing flammable or
combustible materials into close proximity of this projector could result in the spontaneous ignition of that material, resulting in a
fire. For this r eason, it is absolutely necessary to leave an exclusion zone around all external s urfaces of the projector whereby no
flammable or combus tible m aterials are present:
•The exclusion zone must not be less than 40 cm (16 in.).
•Loose papers or other objects may not be nearer to the projector than 10 cm (4 in.) on any side.
•Never look into the exhaust output on top of the p rojector. High luminance, UV radiation and glass particles in the event of a
lamp explosion could result in damage to the eye. The installation of an exhaust system on top of the pr ojector is mandatory
before operating the projector.
To protect untrained users and children against high intensity light beams, the light beam Hazard Distance (HD) shall be taken into
account. See "Light beam Hazard Distance (HD)", page 10.
R5905963 PROMETHEUS SERIES 09/03/2015
5
Page 10
1. Safety
1.3Important safety instructions
To prevent the risk of electrical shock
•This projector should be operated from an AC power source. Ensure that the mains voltage and capacity matches the projector
electrical ratings. If you are unable to install the AC requirements, contact your electrician.
•Installation acc ording to the local electrical code and regulations by qualified service personnel only.
•This p roduct is equipped with a barrier strip for the connection of a power line. The configuration depends on the projector:
- Prometheus I: three-terminal barrier strip for the connection of a mono phase power line with a separate earth ground PE.
- Prometheus II: fi ve-terminal barrier strip for the c onnection of a 3W+N+PE or 3W+PE power system.
If you are unable to install the AC Requirements, contact your electrician. D o not defeat the purpose of the grou
•The cross-sectional area of the conductors in the p ower supply cord shall not be less than 4 mm
The cross-sectional area of the UPS inlet cord and external fan pow er cord shall be not less than 0.75 mm² or AWG 18.
•The electronics of the projector (UPS INLET) must be powered either from a suitable UPS unit or from the power outlet socket
(UPS OUTLET) provided on the projector. An adapted short power cord (2-pole 3-wire grounding) is added to the projector
accessories to loop through the power from UPS OUTLET to UPS INLET.
•The provided power output socket (UP S OUTLET) on the projector m ay o nly be used to provide power to the projector electronics. Never connec t other devices to this power output socket.
•The exhaust fan outlet may only be used to power an external blower, maximum 3A.
•The building installation has to be provided with a circuit breaker of max. 40A to protect the complete unit.
•A readily accessible disconnect device must be incorporated externally to the equipment for remo val of the power to the projector mains terminals.
•Disconnect the power to the projector m ains terminals and unplug the power cord at UPS INLET for removal of all power from
the projector.
•High leakage current. Earth connection essential before connecting supply.
•Do not allow anything to rest on the power cord. Do not locate this product where persons will walk on the cord. To disconnect
the cord, pull it out by the plug. Never pull the cord itself.
•Do not operate the projector with a damaged cord. Replace the cord.
Do no t operate the projector if the projector has been dropped or damaged - until it has been examined and approved for
operation by qualified service personnel.
•Position the cord so that it will not be tripped over, pulled, or contact hot surfaces.
•If an extension cord is necessary, a cord with a current rating at least equal to that of the proj
for less amperage than the projector may overheat.
•Never push objects of a ny kind into this product through cabinet slots as they may touch dangerous voltage points or short out
parts that could result in a risk of fi re or electrical shock.
•Do not expose this projector to rain or moisture.
•Do not immerse or expose this projector in water or other liquids.
•Do not spill liquid of any kind on this projector.
•Should any liquid or solid object fall into the cabinet, unp lug the set and have it checked b y qualified service personnel before
resuming operations.
•Do not dis assemb le this projector, always take it to qualifi ed s ervice personnel when service or repair work is required.
•Do not use an accessory attachment which is not recommended by the manufacturer.
•Lightning - For added protection for this v ideo product during a lightning storm, or when it is left unattended and unused for long
periods of time, remove all power from the projector. This will prevent damage t
surges.
o the device due to lightning and AC power-line
2
or AWG 10.
ector should be used. A cord rated
nding.
6
R5905963 PROMETHEUS SERIES 09/03/2015
Page 11
1. Safety
To prevent personal injury
•Leave an ex clusion zone around a ll external surfaces of the projector. See "Safety training to be provided by the installer", page
5.
•Isolate electrically before replacing the lamp or lamp house. Caution: hot lamp (house).
•Caution: high pressure lamp may explode if improperly handled. Refer s ervicing to qualified service personnel.
•To prevent injury and physical damage, always read this manual and all labels on the system before inserting the lamp casing,
connecting to the wall outlet or adjusting the projector.
•To pre vent injury, take note of the weight of the projector. Minimum 4 adult persons are needed to carry the projector.
•To prevent injury, ensure that the lens and all covers are correctly installed. See installation procedures.
•Warning: high intensity light beam. NEVER look into the lens! High luminance could result in dam age to the eye.
•Warning: extremely high brightness lamps: t his projector uses extremely high brightness lamp s. Never attempt to look
directly into the lens or at the lamp. Avoid close range reflection of the projected image on any reflecting surface (such as glass,
metal, …). Take into account the light beam Hazard Distance (HD) and never enter the Restriction Zone (RZ), as d e fi ned in
chapter "Light beam Hazard Distance (HD)", page 10).
•Before attempting to remove any of the projector’s covers, disconnect the projector mains terminals for removal of all power
from the projector.
•When req uired to remov e all power from the projector, to access parts inside, always disconnect the projector ma
•Do not place this equipment on an unstable cart, stand, or table. T he product may fall, causing serious damage to it and
possible injury to the user.
•It is hazardous to operate without lens or shield. Lenses , shields or ultra violet screens shall be changed if they have become
visibly da maged to such an extent that their effectiveness is impaired. For example by cracks or deep scratches.
•Warning: protection from ultraviolet radiation: do not look directly in the light beam. The lamp contained in this product is
an intense source of light and heat. One component of the light emitted from this lamp is ultraviolet light. Potential eye and s kin
hazards are present when the lamp is energized due to ultraviolet radiation. Avoid unnecessary e xposure. Protect yourself and
your employees by making them a w are of the hazards and how to protect themselves. Protecting the skin can be accomplished
by wearing tightly woven garments and gloves. Protecting the eyes from UV can be accomp lished by wearing safety glasses
that are designed to provide UV pr otection. In addition to the UV, the visible light from the lamp is intense and should also be
considered when choosing protective eye wear.
•Exposure to UV radiation: some medications are known to make individuals ext
Conference of Governmen tal Industrial Hygienists (ACGIH) recommends occupational UV exposure for an-8 hour day to be
less than 0,1 micro-watts per square centimeters of effective UV radiation. An evaluation of the workplace is advised to assure
employees are not expo sed to cumulative radiation levels exceeding the
radiation is allowed for only 1 hour per day for maintenance and service personnel.
se government guidelines. The exposer of this UV
ra sensitive to UV radiation. The American
ins terminals.
WARNING: Never look into the exhaust output on the top of the projector. High luminance and UV radiation
could result in damage to the eye. The installation of an exhaust system on top of t he projector is m and atory
before operating the projecto r.
To prevent fire hazard
•Leave an ex clusion zone around a ll external surfaces of the projector. See "Safety training to be provided by the installer", page
5.
•Do not cover the projector or the lens with any material while the projector is in operation.
•Keepflammable and combustible materials away from the projector at all times.
•Mount the projector in a well ventilated area away from sources of ignition and out of direct sun light.
•In the event of fire use sand, CO
•Heat sensitive materials should not be placed in the path o
•Slots and openings in this equipment are provided for ventilation. To ensure reliable operation of the projector and to protect
it from overheating, these openings must not be blocked or covered. The openings should never be blocked by placing the
projector too close to walls, or other similar surface. This projector should ne ver be placed near or over a radiator or heat
register. This projector should not be placed in a built-in installation or enclosure unless proper ventilation is provided.
•Projection rooms must be well ventilated or cooled in order to avoid build up of heat. It is necessary to vent hot exhaust air from
console to the outside of the building. T he mandatory exhaust system must include a blower that m aintain at least 10m
(350 CFM) when measured at the projector exhaust opening.
•Let the projec tor cool down completely before storing. Remove cord from the projector when storing.
•Heat sensitive materials should not be placed i
or dry pow der fire extinguishers. Never use water on an electrical fire.
2
f the ex hausted air or on the lamp house.
n the path of the exhausted air or on the lamp house.
3
/min
R5905963 PROMETHEUS SERIES 09/03/2015
7
Page 12
1. Safety
To prevent projector damage
•Leave an ex clusion zone around a ll external surfaces of the projector. See "Safety training to be provided by the installer", page
5.
•This projector has been designed for use with a specific lamp (house) type. See installation instructions for its correct type.
•The air filters of the projector mu st be cleaned or replaced on regular base. Neglecting this could result in disrupting the air flow
inside the projector, causing over heating. Overheating may lead to the projector shutting down during operation.
•The projector m ust always be installed in a m anner which ensures free flow of air into its air inlets and the mandatory exhausted
system must be capable of removing minimum 10m
•In or der to ensure that correct airfl ow is maintained, and that the p rojector complies with Electromagnetic Compatibility (EMC)
requirements, it should always be operated with all of it’s covers in place.
•Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product a
overheating, these openings must not be blocked or covered. The openings should never be blocked by placing the product
on a bed, sofa, rug, or other similar surface. This product should never be placed near or over a radiator or heat register. The
device should not be placed in a built-in installation or enclosure unless pro per ventilation is prov
•Ensure that nothing can be spilled on, or dropped inside the projector. If this does happ en, switch off and unplug the mains
supply immediately. Do not operate the projector again until it has been checked by qualified service personnel.
•Do not block the projector cooling fans or free air movement around the projector.
•Do not use this equipment near water.
•Proper operation of the projector can only be guaranteed in table mounting. It is not permitted to use the projector in another
position. S ee installation procedure for correct installation.
•Special care for Laser B eam s: special care should be used when DLP projectors are used in the same room as high power
laser equipment. D irect or indirect hitting of a laser beam on to the lens can severely damage the Digital Mirror De vices
which case there is a loss of warranty.
•Never place the projector in direct sun light. S un light on the lens can severely damage the Digital Mirror Devices
case there is a loss of warranty.
•Save the original shipping carton and packing material. They will come in handy if you ever have to ship your equipment. For
maximum protection, repack your set as it was originally packed at the factory.
•Disconnect the power to the projectors mains terminals before cleaning. Do not use liquid cleaners or aerosol cleaners. Use
a damp cloth for cleaning. Never use strong solvents, such as thinner or benzi
will dam age the cabinet. Stubborn stains may be rem oved with a cloth lightly dampened with mild detergent solution.
•To ensure the highest optical performance and resolution, the projection lenses are specially treated with an anti-reflective
coating, therefore, avoid touching the lens. To remove dust on the lens, use a soft dry c loth. Do not use a damp cloth, detergent
solution, or thinner.
•Rated maximum ambient temperature, t
= 35°C (95°F).
a
•The lamp house shall be replaced if it has become damaged or thermally deformed.
3
/min (350 CFM) measured at the projector’s exhaust opening.
nd to protect it from
ided.
ne, or, patrol, or abrasive cleaners, since these
TM
in which
TM
in
On servicing
•Refer all servicing to qualified s ervice personnel.
•Attempts to alter the factory-set internal controls or to change other control settings not specially discussed in this manual can
lead to permanent damage to the projector and cancellation of the warranty.
•Remove all p ower from the projector and refer servicing to qualified service pers onnel under the following conditions:
- When the power cord or plug is damaged or frayed.
- If liquid has been spilled into the equipment.
- If the product has been exposed to rain or water.
- If the product does not operate normally when the operating instructions are followed. Adjust only those controls that are
covered by the operating instructions since improper adjustment of the other controls may result in damage and will often
require extensive work by qualified service personnel to restore the product to normal operation.
- If the product has been dropped or the cabinet has b een dam aged.
- If the product exhibits a distinct chang e in performance, indicating a need for service.
•When replacement parts are required, be sure the service personnel has used original Barco replacement parts or authorized
replacement parts which have the same characteristics as the Barco original part. Unauthorized substitutions may result in
degraded performance and reliability, fire, electric shock or other hazards. Unauthorized substitutions may void warranty.
•Upon completion of any service or repairs to this projector, ask the service personnel to perform safety checks to determine
that the product is in proper operating condition.
•Possible explosion hazard: always keep in mind the caution below:
WARNING: The user is not permitted to perform or attempt any phase of xenon lamp hand ling or s ervice.
Only trained and qualified technical service personnel are allowed to handle the xenon lamp.
8R5905963 PROMETHEUS SERIES 09/03/2015
Page 13
CAUTION: Xenon compact arc lamps are highly pressurized. When ignited, the normal operating temperature
of the bulb increases the pressure to a level at which the bulb may explode if not handled in strict accordance
to the manufacturer’s instructions. The bulb is stable at room temperature, but may still explode if dropped or
otherwise mishandled. Wh enever the lamp house, containing a xenon lamp, has to be dismantled or whenever
the protective container or cloth has to be removed from the xenon lamp , authorized protective clothing MUST
be wo r n!
Authorized protective clothing for xenon lamp handling
WARNING: Always we ar face protection (full face shield) when handling xen on lamp s.
WARNING: Always wear protective clothing (welder’s jacket) w hen handling xenon lamps.
WARNING: Always wear clean leather gloves with w rist protectors when handling xenon lamps.
1. Safety
To prevent battery explosion
•Danger of explosion if battery is incorrectly installed.
•Replace only with the same or equivalent type recommended by the manufacturer.
•For disposal of used batteries, always consult federal, state, local a nd provincial hazardous was te dispos al rules and regulations
to ensure proper disposal.
R5905963 PROMETHEUS SERIES 09/03/20159
Page 14
1. Safety
1.4Light beam Hazard D istance (HD)
HD
Light beam Hazard Distance ( HD) is the distance from the source at which the intensity or the energy per surface unit
becomes lower than the applicable safety limit. The light beam can thus be considered as dangerous if the operator
is closer from the source than the HD.
Restriction Zone (RZ) based on the HD
The HD is defined from the projection lens surface towards the position of the lowest projected beam where the irradiance eq uals
the applicable safety limit. The HD depends on the amount of lumens produced by the projector and the type of lens installed. See
next chapter HD in function of the lens Throw Ratio (TR).
To protect untrained users the installation shall comply with the following installation req uirements: light output levels in excess of the
limits shall not be permitted at any point less than 2.0 meters (SH image 1-1) above any surface upon which persons are assumed
to stand or 1 meter (SW image 1-1) below or in lateral separation from any place where such persons are assumed to be. See
image 1-1.
RATH
HD
RA
SH
RZ
SH
Image 1-1
ASideview.
BTop view.
RA Restricted Access location (booth area of projector).
PR Projector.
TH Theater.
RZ Restriction Zone in the theater.
SH Separation H eight. Must be minimum 2 meter.
SW Separation Width. Must be minimum 1 meter.
Based on national requirements, no person is allowed to enter the projected beam within the zone between the projection lens and
the r elated hazard distance (HD). This shall b e physically impossible by creating sufficient separation height or by placing barriers.
The minimum separation height takes into account the surface upon which persons are as sumed to stand.
On image 1-1 a typical setup is displayed. It must be verified by the installer if t hese minimum r equirements are met. If required a
restricted zone (RZ ) in the theater must be established. This can be done by using physical barrier, like a red rope as illustrated in
image 1-2.
Image 1-4
HD in meter for the Prometheus II equipped with ’HD HB’ or ’HD HC’ type lens
TR
12R5905963 PROMETHEUS SERIES 09/03/2015
Page 17
2. GENERAL
About this chapter
Read this chapter before ins talling your Prometheus. It contains important information concerning installation requirements for the
Prometheus, such as minimum and maximum allowed am bient temperature, humidity conditions, required safety area around the
installed projector, required power net, etc.
Furthermore, careful consideration of things such as ima ge size, ambient light level, projector placement and type of screen to use
are critical to the optimum use of the projection system.
Barco provides a guarantee relating to perfect manufacturing as part of the legally stipulated terms of guarantee. Observing the specification mentioned in this chapter is critical for projector performance. Neglecting
this can result in loss of warranty.
Overview
•Safety training to be provided by the installer
•Installation requirements
•Unpacking the projector
•Initial inspection
•Installation process overview
2. General
R5905963 PROMETHEUS SERIES 09/03/2015
13
Page 18
2. General
2.1Safety training to be provided by the installer
WARNING: The installer is responsible that the user is instructed. The user will sign a document to confi rm
that the instructions have been received and understood.
Users definition
The Prometheus is intended for persons who have been instructed and trained by a skilled person (installer or service pers onnel)
to identify energy sources that may cause injury and to take precautions to avoid unintentional contact with or exposure to those
energy sources.
The skilled person must instruct the user about:
•High intensity light beam. The user must respect the exclusion zone, based on the light beam Hazard Distance (HD).
•Dangerous energy sources inside the projector. The user is not allowed to remove any cover from the projector.
•Small glass parts can leave the projector in the event of lamp explosion. Keep 1 m (40 in.) distance from the air outlet side of
the projector during operation.
•The installation, maintenance or service is for skilled persons only.
•The requirements for a restricted access location and an exclusion zone.
Restricted access location
To protect untrained persons and children, the projector must be installed in a restricted access location. The definition of a
restricted access location is a location for equipment where both of the following paragraphs app ly:
•Access can only be gained by skilled persons (installer or service personnel) or persons who have been instructed and trained
by a skilled person. The persons m ust have been ins tructed about the reasons for the restriction applied to the location and
about the precautions that shall be taken.
•Access is only possible through the use of the tool or lock and key, or other means of s ecurity, and is controlled by the authority
responsible for the location.
Exclusion zone
The projector radiates heat on its external surfaces and from ventilation ducts during normal operation. Exposing flammable or
combustible materials into close proximity of this projector could result in the spontaneous ignition of that material, resulting in a
fire. For this r eason, it is absolutely necessary to leave an exclusion zone around all external s urfaces of the projector whereby no
flammable or combus tible m aterials are present:
•The exclusion zone must not be less than 40 cm (16 in.).
•Loose papers or other objects may not be nearer to the projector than 10 cm (4 in.) on any side.
•Never look into the exhaust output on top of the p rojector. High luminance, UV radiation and glass particles in the event of a
lamp explosion could result in damage to the eye. The installation of an exhaust system on top of the pr ojector is mandatory
before operating the projector.
To protect untrained users and children against high intensity light beams, the light beam Hazard Distance (HD) shall be taken into
account. See "Light beam Hazard Distance (HD)", page 10.
14
R5905963 PROMETHEUS SERIES 09/03/2015
Page 19
2.2Installation requirements
Environment conditions
Table below sum marizes the physical environment in which the Prometheus may be safely operated or stored.
EnvironmentOperatingNon-Operating
Ambient Temperature10°C (50°F) to 35°C (95°F)-15°C (5°F) to 60°C (140°F)
Air cleanlinessClean office environment (equivalent with cleanroom
Humidity
Altitude
Let the projector ac climatize after unpacking. Neglecting this may result in a startup failure of t he Light Processor Unit.
standard ISO 14644-1 ISO Class 9)
5% to 85% RH Non-condensed5% to 95% RH Non-Condensed
-60 (-197Ft) to 3000m (9843Ft)-60 (-197Ft) to 10000m (32810Ft)
Cooling requirements
The projector is fan cooled and must be installed with sufficient space around the projector head, minimum 20 cm (8 inch) to ensure
sufficient air flow. It should be used in a n area where the am bient temperature, as measured at the projector air inlet , does not
exceed +35°C (+95°F).
The installation of an exhaust system is MANDATORY. The installed exhaust blower must remove an air volume of minimum
3
10m
/min (350 CFM) measured at the exhaust output of the projector.
n.a.
2. General
Main Power requirements
ProjectorPower requirements
Prometheus I200-240 VAC, 50-60Hz, 30A at 200 VAC (mono phase)
The power cord required to connect the projector with the power net is not delivered with the projector. It is the responsibility of the
customer to provide the correct type of power cord. The cross-sectional area of the conductors in the power supply cord shall not
be less than 4 mm² or 10 AWG, minimu m 300V.
To protect operating personnel, the N ational Electrical Manufacturers Association (NEMA) recomm ends that the instrument panel
and cabinet be grounded. In no event shall this projector be operated without an adequa te cabinet ground connection.
The AC supply must be installed by a qualified electri
must comply with local codes.
A r eadily accessible disconnect de vice shall be incorporated externally to the equipment for removal of the power to the equipment
mains terminals.
The building installation must be provided with a circuit breaker of max. 40A to protect the complete unit.
WARNING: Disconnect the power to the unit mains ter
of all power from the unit
cian in conformance to local codes. Hardware, wire sizes and conduit types
minals and unplug power cord at UPS inlet for removal
UPS requirements
The Uninterruptible Power Supply (U PS), also known as a Continuou s Power Su pply (CPS), must have an output voltage of 200-240V
at 50-60Hz and must be capable of deliver
and not for the lamp.
The connection between the UPS unit and the UPS inlet of the projector must be done with a certified AC power supply cord of
minimum 0,75 mm² or 18 AWG and minimum 300V.
ing an output current of 5,5 amperes. This UPS provides only power for the electronics
CAUTION: The 200–240V power outlet (UPS OUTLET) of the projector may not be used to provide the UPS
unit with power! The UPS OUTLET of the projector may only be used for connection to the UPS INLET of the
projector.
The Prometheus does not have a built in UPS unit.
R5905963 PROMETHEUS SERIES 09/03/201515
Page 20
2. General
Exhaust outlet for external fan
The exhaust outlet has an output voltage of 200–2 40V at 50–60 Hz; switched and maximum 3 amperes is allowed.
The connection between the exhaust outlet and the external blower must be done with a certified AC power supply cord of minimum
0,75 mm² or 18 AWG and minimum 300V.
CAUTION: The 200–240V power outlet (exhaust outlet) of the p rojector may not be used to provide power to
any other device than an external exhaust fan. Maximum allowed current : 3A.
Projector weight
Do not underestimate the weight of the Prometheus. The projector weights about ±133 kg (±293 lb.) without lens. Be sure that the
pedestal on which the projector has to be installed is capable of handling five (5) times the complete load of the system.
Measures to resolve radio interference
Operation of this equipment in a residential area may cause radio interference. Possible interference s
following non limitative product installation measures:
•Create more separation distance between projector and interfered device.
•Change direction of the interfered device.
•Electromagnetic shielding of the projection booth.
No interference to radio communication in neighbor buildings possible if a separation distance of 30 m (32.8
yards) is provided.
hall be s olved by one of the
Barco o ffers a pedestal for the Prometheus. This universal pedestal allows a solid and easy setup of the
projector. The universal pedestal has a separate co mp artment to install the UPS unit for the Prometheus.
Futhermore, the universal pedestal contains a standard 19” rack to build in the projector peripherals such as
alternative content switchers (e.g. ACS-2048)
16R5905963 PROMETHEUS SERIES 09/03/2015
Page 21
2.3Unpacking the projector
What has to be done ?
Upon delivery, the p rojector is packed in a carton box upon a wooden pallet and secured with banding and fastening clips. Furthermore, to provide protection during transportation, the projector is surrounded with foam. Once the projector has arrived at the
installation site, it needs to be removed from the carton box and wooden pallet in a safe manner without damaging the projector.
After unpacking let the projector acclimatises t o a room te mperature higher then 10°C (50°F) and lower then
35°C (95°F). Neg lecting this may result in a start up failure of the Light Processor Unit.
How to unpack
1. L oosen the banding by pulling the free end of the banding loop in the clip.
Take off the box cover.
2. General
Image 2-1
Open banding
2. O pen the box.
Take out the small box between the outer and inner box containing the manuals.
Remove the outer carton box
R5905963 PROMETHEUS SERIES 09/03/2015
17
Page 22
2. General
Image 2-2
Remove o uter carton
3. R emov e the inner carton box.
Image 2-3
Remove inner carton
4. L oosen the banding by pulling the free end of the banding loop in the clip.
Take off the upper ca rton plate (1)
Remove from the wooden pallet (2)
18
R5905963 PROMETHEUS SERIES 09/03/2015
Page 23
2. General
1
2
Image 2-4
Remove wooden pallet
5. Take the projector from the wooden boa rd by gripping the bottom of the projector and place the projector on the pedestal.
Image 2-5
Remove projector
R5905963 PROMETHEUS SERIES 09/03/201519
Page 24
2. General
2.4Initial inspection
General
Before shipment, the projector was inspected and found to be free of mechanical and electrical defects. A s soon as the projector is
unpacked, inspect for any damage that may have occurred in transit. Save all packing m aterial until the inspection is completed. If
damage is found, file claim with carrier immediately. The Barco S ales and Service office should be notifi ed as soon as possible.
The packaging of the Prometheus is provided with a shock-watch label. If this shock-watch label was triggered (red colored at arrival) during transport, indicates that the package was p o ssibly roughly h
the transport company. In this case, the instructions mentioned on the label, should be followed, which are:
adding a no te on the “bill of lading” and informing the transport company and the Barco sales and service
office as soon as po ssible.
andled by
Box content
After unpacking the projector it is recommen ded to check if all following items where include
•One short power link cable (mono phase) (in c ase no UPS is used) - Installed on projector.
•This manual (installation m anual).
•Safety manual
The projector lens and xenon lamp are not included in the package of the projector.
d:
Mechanical check
This check should confirm that there are no broken knobs or connectors, that the cabinet and panel surfaces are free of dents and
scratches, and that the operating panel is not scratched or cracked. The Barco Sales and Service office should be notified as soon
as possible if this is not the case.
Tamper labels
During ins tallation please inspect the tamper labels, if they are damaged please contact Barco tech support.
The tamper labels are requ ired by DCI to provide easy visual indication if the equipment was tampered with. The projectors are
tested and labeled for shipping to ensure that the system was not co
These tamper labels can be found behind the input cover. S ee "Remo val of the input cover", page 135.
mpromised before reaching the customers final destination.
20
R5905963 PROMETHEUS SERIES 09/03/2015
Page 25
2.5Installation process overview
Let the projector acclimate to the a mb ient temperature after unpacking. Neglecting this m ay result in a startup
failure of the light processo r unit.
Set up from A to Z
After you have unpacked and checked the projector, you can start with the installation process of your Prom etheus. This c hapter
gives you an overview of all the different stages in the installation process which you have to follow to set your Prometheus up and
running. Each stage is briefly described and refers to more detailed s tep by step procedures in this ma nual. Use this overview as a
checklist to e nsure that you have followed all stages in the setup process of your Prometheus.
Set up from A to Z
1. C heck if all installation req uirements are fulfilled such as the environment conditions of the installation area, capacity of the
exhaust system, electrical facilities, etc. Note that a solid pedestal is required to s upport the projector head. For more info see
topic "Installation requirements", page 15 .
2. P h ysical installation of the projector upon its pedestal and connecting the air outlet of the projector with the exhaust system.
Note that the exhaust system is MA NDATORY. See chapters "Positioning the Prometheus at por t window", page 24, and "Installation of the exhaust system", page 27.
3. E lectrical connection with the power net. See chapter "Connecting the Prometheus I projector with the power net", page 32 or
"Connecting the Prometheus II projector with the power net", page 33. For the Power input set up chapter (only for Prometheus
II), see "Power input setup (only for Prometheus II)", page 30.
4. Installation of a suitable UPS unit or bypass the power in and outlet for the projector elec tronics. See chapters "Power loop
through to the projector electronics", page 35 or "Connecting a UPS to the projector electronics", page 36 .
5. In stallation of the xenon lamp in ca se the xe non lamp is not installed in the lamp house yet. To install the xenon lamp the lamp
house has to be removed from the projector. To install the xenon lamp correctly and in a safe manner, see the detailed step by
step procedures in the chapter "Installation of the xenon lam
6. In stallation of the lens. First select an appropriate lens which t hrow ratio covers the screen size and the projector - screen
distance. Then install the lens in the lens holder of the projector. For more information about available lenses, lens selection and
lens installation see chapter "Lens installation", page 73.
7. In stallation of the Communicator Touch Panel. See chapter "Communicator Touch Panel", page 121.
8. F ence off the exclusion zone if needed. See chapter "Safety training to be provided by the installer", page 14, exclusion zone.
9. A lignment of the projected image o n the screen. The projector can now be switched on to project its first image (test pattern)
on the screen. Then the image can be a ligned with the screen size of the application. Follow the next steps to achieve that:
a) Place the ON/OFF switch of the projector in the ”I” position. As a result the pr ojector starts to initialize. The status lights of
the projector lights up GREEN onc e the projector is initialized.
b) Press the STANDBY button on the local keypad to activate the lamp.
c) Press the DOWSER button on the local keypad to open the dowser of the projector. The dowser is open if the color of the
DOWSER button is GREEN.
d) Press the TEST PATTERN button on the local keypad to project one of the internal test patterns of the projector on the screen.
e) Use the lens ZOOM, SHIFT and FO CUS buttons on the local keypad the match the projected image with the screen. Tilt the
projector in case you can not SHIFT the image completely upon the screen. See "Lens shift, zoom & focus", page 77.
10.Resetting the lamp parameters. Th e “LAMP INFO” parameters which are stored on the controller board of the projector MU ST
be updated after each installation of an xenon lam p inside the lamp house. Neglecting this update will result in poor performance
and short life time of the xenon lamp . See chapter "Resetting the lamp parameters", page 66.
11. Realignment of the xenon lamp in its reflector. For optimal performance of the xenon lamp it is required to realign the lamp
after installation in the lamp h ouse. See "Realignment of the lamp in its reflector (manual Lamp House)", page 67 for mo re
information.
12.Adjusting the light path. Normally the lens holder and the converg ence of the projector is perfectly adjusted at the factory.
Nevertheless, some applications req
adjustment", pag e 82, to adjust the Scheimpflug and see "Convergence", page 157 to adjust the convergence of the light path.
13.Registration of the projector. The Prometheus is DCI compliant and should be registered by Barco. Therefore, the digital
certificate inside the pr ojector will be used to secure encryption key comm unication between the projector and the rest of the
theatre system (server and theatre management system).
14.Provide safety instructions to the user and explain about the light beam Hazard Distance (HD).
provided by the installer", page 14.
Warning: The installer is responsible that the user is instructed. The user will sign a document to confirm that the instructions
have been received and understood.
uire a readjustment of the lens holder, convergence or both. See procedure "Scheimpflug
p in manual S/M Lamp House", page 53.
See "Safety training to be
2. General
R5905963 PROMETHEUS SERIES 09/03/2015
21
Page 26
2. General
15.Projection of a digital cinema movie.
In ca se the projector is equipped with an ICMP, download the ICMP device certificate, request KDM and DCP from your content
supplier, ingest KDM and DCP, and play out the movie. for detailed instructions see chapter "ICMP", page 105, and user guide
of the Communicator and /or (Web) Commander.
In case the projector is equipped with a HD-SDI input module apply a single or dual channel SMPTE (HD-SDI) source to the
input ports of the HD-S DI input module and s tart up the projector. See chapter "Input & communication", page 89. Use the
Communicator (Touch Panel) to config ure the applied source. See the user guide of the Communicator (Touch Panel) for more
detailed information.
In case the projector is equipped with an Integrated Media Block (IMB) or Integrated Media Server (IMS) see user guide of the
IMB or IMS for detailed instructions.
22
R5905963 PROMETHEUS SERIES 09/03/2015
Page 27
3. PHYSICAL INSTALLATION
About this chapter
This chapter describes ho w the mec hanical and electrical set up of the projector has to be done.
Overview
•Positioning the Prometheus at port window
•Installation of the exhaust sy stem
•Access to the power connection
•Power input setup (only for Prometheus II)
•Connecting the Prometheus I projector with the pow er net
•Connecting the Prometheus II projector with the power net
•Power loop through to the projector electronics
•Connecting a UPS to the projector electronics
3. Physical installation
R5905963 PROMETHEUS SERIES 09/03/2015
23
Page 28
3. Physical installation
3.1Positioning the Prometheus at port window
WARNING: The installation of the Prometheus requires at least 4 adult persons.
General guide lines
•Use a solid pedes tal to put the Prometheus on. Ensure that the pedestal can handle the weight of the pro
of the projector are captured.
•The pedestal should be placed in front of the port window wall in a manner that the projector front c over is at a minimum distance
of 20 centimeters from the port window.
20 cm
Image 3-1
Positioning at port window
Barco o ffers a pedestal for the Prometheus. This universal pedestal allows a solid and easy setup of the
projector. The universal pedestal has a separate compartment to install the UPS unit (if available) for the
Prometheus. Futhermore, the universal pedestal contains a standard 19” rack to build in the projector peripherals like alternative content switchers (e.g. ACS-2048).
jector and that all feet
Necessary tools
•14 mm wrench
•17 mm wrench
Projector centering
1. If the projector is standalone in front of the port window, center the projector with the theatre screen (see ref A image 3-2).
2. If a film projector is already present (proj
Note: Unlike film projectors, it is best to keep the projector lens surface as parallel to the screen as possible, even if it is
significantly above the screen center.
The off-center position slightly increases side keystone, but will minimize hor izontal lens offset required.
ector will be off-center), try to optimize aim (s ee ref B image 3-2).
24
R5905963 PROMETHEUS SERIES 09/03/2015
Page 29
3. Physical installation
AB
Image 3-2
Projector centering
3. P roceed to level the pr ojector by adjusting the feet of the projector as follows:
- Loosen the nuts (A), using a wrench o f 24 m m, on the threaded rod.
- Adjust the height of the 4 legs (B) to level the projector, using a 17 mm wrench.
- Secure the leg height by tightening the nuts (A).
Note: There must be at least 5 c m between the bottom side of the projector and the pedestal.
SCREEN CENTERSCREEN CENTER
OFF-CENTER
A
B
Image 3-3
Projector level ing
4. L ater, when the projector is up-and-running, adjust precise im age geome try and placement.
Projector tilting
In an ideal installation, the Prometheus lens surface is centered with and parallel to the screen. This orientation helps to ensure
optimized lens performances with minim al offset. If this position is not possible (such as when the projector is significantly higher
than the center of the screen), it is better to rely o n o ffset rather than extra tilt.
1. B efore adjusting tilt, make sure the projector is as well-centered with the theatre screen as possible for your installation area.
2. C heck with theatre personnel for th
3. Tilt the projector to closely m atch this sc reen tilt angle as follows:
- Loosen the nuts (A), using a wrench o f 24 m m, on the threaded rod.
- Adjust the height of the legs until the projected im age matches the projection port window and the s creen tilt.
- Secure the leg height by tightening the nuts (A).
e degree of screen tilt, or measure this incline with a protractor at the screen.
R5905963 PROMETHEUS SERIES 09/03/2015
25
Page 30
3. Physical installation
Image 3-4
Projector tilting
Barco o ffers a pedestal for the P ro metheus. This universal pedestal allows you to easily tilt the projector
forwardupto6°.
90°
Inclined screen
26R5905963 PROMETHEUS SERIES 09/03/2015
Page 31
3.2Installation of the exhaust system
WARNING: THE USE OF AN EXHAUST SYSTEM IS MANDATORY !
WARNING: Never look into the exhaust output. High luminance and UV radiation could result in damage to
the eye. The installation of an exhaust system is mandatory before operating the projector.
3. Physical installation
CAUTION: The exhaust system must be capable of removing minimum 10 m
projector’s exhaust opening.
3
/min (350 CFM), measu red at the
About Exhaust
The exhaust stack of the projector head is designed to fit a 201 mm (7.91 inch) diameter duct. This size must be used throughout
the entire system and installed to eliminate any possibility of downdraft or rain dripping into the lamp house.
The exhaust fan must be capable of removing minimum 10m
A built-in vane switch detects if the airflow in the exhaust opening is high enough. When something goes wrong one of the following
error codes can be displayed : 6090 or 6091 (insufficient air flow in ex haust of projector check exhaust fan and/or exhaust air outlet
system).
Check the functioning of this vane switch regularly. Replace if necessary.
3
/min (350 CFM ), measured at the projector’s exhaust opening.
How to install the Exhaust stack
See illustration below:
Image 3-5
Exhaust system
R5905963 PROMETHEUS SERIES 09/03/201527
Page 32
3. Physical installation
Ensure good condition of the lamp house blower. Keep the blower inlet clean for unrestricted air flow.
To ensure maximum lamp life, operate the lamp house blower an d the exhaust system for at least ten m inutes
after extinguishing the lamp.
Optional electrical connection of the fan to t he projector
The exhaust fan may electrically be connected w ith the projector. W hen that is done, the blower starts working when the lamp is
switched on and stops working after the cool period is c ompleted.
The power socket is located next to ex haust output and may only b e used to connect the external exhaus
other devices is allowed.
The exhaust outlet delivers maximum 3A, 200-240V at 50-60Hz.
The external fan power cord shall be not less than 0.75 mm ² or AWG 18.
t fan. No connection with
Image 3-6
Fan power connection
28R5905963 PROMETHEUS SERIES 09/03/2015
Page 33
3.3Access to the po wer connection
Necessary tools
Flat screw driver 6 mm
How to access
1. R emov e the back cover.
2. L oosen both captive screws (1).
3. Physical installation
1
Image 3-7
Power connection cover, captive screws
3. S lide off the power connection c over.
Image 3-8
Power connection cover, captive screws
1
Image 3-9
Terminal strip accessible
The terminal strip and connection plate is accessible.
R5905963 PROMETHEUS SERIES 09/03/2015
29
Page 34
3. Physical installation
3.4Power input setup (only for Prometheus II)
About the power input
The projector power input can be configured for a power supply of 230/400V 3W+N+PE 16A 50-60Hz (Y connection) or 208V 3W+PE
27A 50-60Hz (Δ connection). Before operating the projector, place the links in the correct position depending on the local power
supply.
For a 3W +N+PE system, 400V is measured between the lines, 230V is measured between the lines and the neutral.
For a 3W+PE system, 208V is measured between the lines.
AB
Image 3-10
Υ-Δ connection
AΥ connection
BΔ connection
Necessary tools
•Flat screw driv er
•Wrench10mm
•Torque wrench 10 mm
HowtoswitchfromaΥ-connection to Δ-connection
1. L oosen the 6 top nuts on the Υ/Δ configuration block. (1 to 6)
YΔ
Image 3-11
Υ to Δ connection
2. Take off the mounted lins (A, B and C). Two links abov e each other or mounted between the upper and middle pin (A, B) and one
link between the middle pin and lower pin (C).
3. M ount the links horizontally on the pins.
4. Turn a nut on eac h pin and secure with a torque wrench set to 7.5 Nm.
1
2
3
A
B
C
4
5
6
HowtoswitchfromaΔ-connection to Υ-connection
1. L oosen the top nuts on the Υ/Δ configuration block (1 to 6).
30
R5905963 PROMETHEUS SERIES 09/03/2015
Page 35
3. Physical installation
Δ
Image 3-12
Δ to Υ connection
2. Take off the mounted links (A, B and C).
3. Connect the right pins together. Place 2 links between the upper pin and the middle pin (A, B)and 1 link between the middle pin
and the lower pin (C).
1
2
3
A
B
C
4
5
6
Y
R5905963 PROMETHEUS SERIES 09/03/2015
31
Page 36
3. Physical installation
3.5Connecting the Prometheus I projector with the power net
WARNING: T he total electrical installation should be protected by an appropriate rated and readily accessi-
ble disconnect switch, circuit breakers and ground fault current interrupters. The installation shall be done
according to the local electrical installation codes.
WARNING: Make sure that the voltage range of projector matches with the vo ltage of the local power net.
CAUTION: The cross-sectional area of the conductors in the Power Supply Cord s hall be not less than 4 mm
or AWG 10
Necessary tools
•Flat torque screw driver
•Adjustable wrench
Necessary parts
•Certified power supply cord 4.0 mm², 10AWG, min. 300V, diameter between 11 mm and 21 mm
•Circuit breaker maximum 40A
How to connect
1. R emov e the back cover.
2. R emov e the power input cover.
3. L oosen the cable gland fixation ring (1).
Note: The cable gland (1) is specified for cab les with a diameter between 11mm and 21mm.
1
2
Image 3-13
Power cable connection
4. P ush the stripped power supply cable through the cab
end is provided with an end sleeve.
Fix the cable in the cable gland by securing ring 1 with an adjustable wrench.
5. C onnect the power cord with the terminal barrier s trip. Use a flat torque screw driver set to 2Nm.
Always connect the ground wire (PE) with the connector indicated with PE on the terminal barrier strip.
Warning: Always connect first the PE wire.
6. Reinstall the power connection cover and the back cover.
32
le gland. W he n using a flexible power c ord, make sure that each conductor
R5905963 PROMETHEUS SERIES 09/03/2015
Page 37
3.6Connecting the Prometheus II projector with the power net
WARNING: T he total electrical installation should be protected by an appropriate rated and readily accessi-
ble disconnect switch, circuit breakers and ground fault current interrupters. The installation shall be done
according to the local electrical installation codes.
WARNING: Make sure that the voltage range of projector matches with the vo ltage of the local power net.
3. Physical installation
CAUTION: The cross-sectional area of the conductors in the Power Supply Cord shall not be less than 4 mm
or AWG 10.
Necessary tools
•Flat torque screw driver 4 mm
•Adjustable wrench
Necessary parts
•(for 3W+N+PE, 230/400V) Certified power cable, minimum 4 mm² or AWG 10, 500V rated, cable diameter between 11 mm and
21 mm or
•(for 3W+PE, 208V) Certified power cable, minimum 4 mm² or AWG 10, 300V rated, cable diameter between 11 mm and 21 mm
•Circuit breaker maximum 40A
How to connect
1. R emov e the back cover.
2. R emov e the power input cover.
3. L oosen the cable gland fixation ring (1).
Note: The cable gland (1) is specified for cab les with a diameter between 11mm and 21mm.
2
1
Image 3-14
Power cable connection
4. P ush the stripped power supply cable through the cable gland. W he n using a flexible power cord, make sure that each con ductor
end is provided with an end sleeve.
Fix the cable in the cable gland by securing ring 1 with an adjustable wrench.
5. C onnect the power cord with the terminal barrier strip. Use a flat torque screw driver set to 1.4 Nm.
R5905963 PROMETHEUS SERIES 09/03/2015
33
Page 38
3. Physical installation
Always connect the ground wire (PE) with the connector indicated with PE on the terminal barrier strip.
If a neutral conductor is available, connect always to the connector indicated with N on the terminal barrier strip
Warning: Always connect first the PE wire.
L1
L2
L3
PE
3W + PE
Image 3-15
Terminal connections
6. Reinstall the power connection cover.
L1
L2
L3
N
PE
3W+N+PE
34
R5905963 PROMETHEUS SERIES 09/03/2015
Page 39
3.7Power loop throu gh to the projector electronics
This procedure explains how to provide the projector electronics with pow er in case no UPS unit is used.
Note that the projector is by default configured for use without UPS. So, the short power link cable is already
installed.
Necessary tools
No tools.
Necessary parts
Short power link cable w ith plug type C13/C14
How to loop through the power
1. P lug in the short power cable (1) which was delivered with the projector.
Warning: Always use the Barco short power cable which is delivered with the projector.
3. Physical installation
3
2
1
Image 3-16
Power loop through connection
2. S ecure both plugs of the short cable with
- Squeeze the fixation spring together.
-Slidethefixation sp ring on the fi xation pins (3) while squeezing together and push it against the power plug.
- Release the fixation spring.
a fixation spring (2). Handle as follow:
3
R5905963 PROMETHEUS SERIES 09/03/2015
35
Page 40
3. Physical installation
3.8Connecting a UPS to the projector electronics
WARNING: Only use UPS units which are suitable for the Prometheus. See chapter ”General”, “Installation
requirements” for more information about the requirements of the UPS.
How to connect the UPS
1. Install the UPS according to the instructions of the manufacturer and the local regulations.
2. C onnect the power output cord from the UPS unit to the UPS inlet socket of the projector (right socket).
Connect directly (A) or drag the c able behind the front cover so that the front cover can be removed without
INLET cable (B).
removing the UPS
A
2
Image 3-17
UPS connection
3. Secure the UPS inlet socket with a fixation spring. Handle as follow:
- Squeeze the fixation spring together.
-Slidethefixation spring on the fixation pins while s queezing together and push it against the power plug.
- Release the fixation spring.
4. Install on the power outlet the second fixation spring to prevent losing it (2).
1
B
CAUTION: The electrical co nn ection with the UPS INLET socket of the projector must be done with a certified
AC power supply cord (minimum 0,75 mm² or 18 AWG and minimum 300V)
CAUTION: Do not use the power OUTLET socket of the projector to provide power to other equipment!
36R5905963 PROMETHEUS SERIES 09/03/2015
Page 41
4. Lamp & Lamp House
4. LAMP & LAMP HOUSE
About this chapter
This chapter describes how to insert a lamp house in the projector and how to r eplace a lamp inside the lamp house.
WARNING: DO NOT PERMIT UNAUTHO RIZED PERSONNEL TO PERFORM OR ATTEMPT ANY PHASE O F
XENON LAMP HANDLING OR SERVICE. ONLY TRAINED AND QUALIFIED TECHNICAL SERVICE PERSONNEL
ARE ALLOWED TO HANDLE THE X ENON LAMP.
CAUTION: Xenon compact arc lamps are highly pressurized. When ignited, the normal operating temperature
of the bulb increases the pressure to a level at which the bulb may explode if not handled in strict accordance
to the manufacturer’s instructions. The bulb is stable at room temperature, but may still explode if dropped or
otherwise mishandled. Wh enever the lamp house, containing a xenon lamp, has to be dismantled or whenever
the protective container or cloth has to be removed from the xenon lamp , authorized protective clothing MUST
be wo r n!
WARNING: Always we ar face protection (full face shield) when handling xen on lamp s.
WARNING: Always wear protective clothing (welder’s jacket) w hen handling xenon lamps.
WARNING: Always wear clean leather gloves with w rist protectors when handling xenon lamps.
Overview
•Introduction
•Supported xenon lamps for t he S/M Lamp House
•Supported xenon lamps for the XL Lamp House
•Removal of the Lamp House
•Removal of the xenon lamp from m anual S/M Lamp House
•Removal of the xenon lamp from manual XL Lamp House
•Installation of the xenon lamp in manu al S /M Lamp House
•Installation of the xenon lamp in manual XL Lamp House
•Check if anode support must be provided with a plain washer
•Installation of the Lamp House
•Resetting the lamp param eters
•Realignment of the lamp in its reflector (manual Lamp House)
R5905963 PROMETHEUS SERIES 09/03/2015
37
Page 42
4. Lamp & Lamp House
4.1Introduction
Lamp and Lamp House
The Prometheus I projector is delivered with a manual or motorized S/M Lamp House without lamp, the Prometheus II projector is
delivered with a manual or motorized XL Lamp House without lamp.
The xenon bulb lamp is delivered separately and has to be installed on site by a qualified service technician.
The xenon bulb lamp is packed in a protective container or wrapped in a protective cloth. Never remove this protective container or
protective cloth without wearing adequate protective clothing (face shield, clean cotton gloves, weld
Image 4-1
Left: Xenon lamp in protective container. Right: Xenon lamp wrapped in protective cloth.
CAUTION: Xenon compact arc lamps are highly pressurized. When ignited, the normal operating temperature
of the bulb increases the pressure to a level at which the bulb may explode if not handled in strict accordance
to the manufacturer’s instructions. The bulb is stable at room te
otherwise mishandled. Wh enever the lamp house, containing a xenon lamp, has to be dismantled or whenever
the protective container or cloth has to be removed from the xenon lamp , authorized protective clothing MUST
be wo r n!
mperature, but may still explode if dropped or
er’s jacket).
Lamp strike policy and lamp warning/error policy versus the lamp runtime
•The projector issues a lamp run time notifica tion message (end have blue status LEDs) approximately 30 hours before the
maximum lamp runtime occurs.
•The projector issues a lamp run time notification message (end have blue status LED s) when the maximu m lamp runtime
occurs.
•The projector will always try to strike the lam p, independent of the lamp runtim e.
Parts identification xenon lamp
1234
Image 4-2
1Cathode of the xenon lamp.
2Envelope (bulb) of the xenon lamp.
3Anode of the xenon lamp.
4Anode wire of the xenon lamp.
38R5905963 PROMETHEUS SERIES 09/03/2015
Page 43
Parts identification manual Lamp House
10
4. Lamp & Lamp House
1
2
3
456
Image 4-3
1Air inlet cathode cooling.
2Adjustment screw horizontal lamp alignment.
3Positioning pin.
4Connection Lamp Info module.
5Positioning pin.
6UV blocker.
7Cathode connection with SPG.
8Anode connection with SPG.
9Removable front cover.
10 Air out let.
11 Removablesidecover.
12 Lamp Info module.
13 Lamp House fixation screw.
14 Adjustment screw horizontal lamp alignment.
15 Lamp cathode fixation screw.
16 Adjustment screw for lamp Z-alignment.
17 Adjustment screw vertical lamp alignment.
9
8
11
17
16
15
14
7
12
13
R5905963 PROMETHEUS SERIES 09/03/201539
Page 44
4. Lamp & Lamp House
4.2Supported xenon lamps for the S/M Lamp House
Cathode adaptor
A cathode adaptor is required to mount the xenon lamp in the Lamp House. The cathode adapter has to be mounted on the cathode
side of the xenon lamp prior to mounting the lamp in to the Lamp H ouse. The purpose of the cathode adapter is to position the arc
of the xenon lamp in the middle of the reflector inside the Lamp House.
Image 4-4
1Cathode adapter manual Lamp House (R865555K)
All lamps and adapters in the table below must be used with the S/M Lamp House (either manual or motorized).
Note that the m aximum lam p power the projector delivers depends on the type of projector and the installed
lamp. Prior to install the lam p it’s important to check with the Communicator software if the lamp is listed in
the list of supported lamps for this projector.
Supported lamp types and their respective anode/cathode adapters for the S/M Lamp House:
Lamp type
Supplier
4kW DHP OSRAM XBO
3kW DHP OSRAM XBO
2kW DHP OSRAM XBO
1200W DHP OSRAM XBO
Cathode adapter S/M Lamp HouseBarco Order No.
R865555KR9855937
R865555KR9855938
R865555KR9855956
R865555KR9855959
DXL40BAF USHIO
DXL30BAF USHIO
DXL20BAF USHIO
DXL12BAF USHIO
XDC-4000B PHILIPS
WARNING: Always use the correct Cathode adapter for the xenon lamp in the Lamp House. Neglecting this
may result in poor performance of the lamp and damage to the xenon lamp and Lamp House. Some adapters
looks the same, therefore check the engraved item number upon the adapter to ensure you use the right
adapter.
R865555KR9855939
R865555KR9855940
R865555KR9855955
R865555KR9855961
R865555KR9856370
40R5905963 PROMETHEUS SERIES 09/03/2015
Page 45
4.3Supported xenon lamps for the XL Lamp House
Anode and cathode lamp adapters are used to position the arc of the xenon lamp in the m iddle of the reflector
inside the lamp house. The size of the xenon lamp vary from type to type. Because of that d ifferent lamp
adapters are required. Futhermore, some lamp types require an anode adaptation bushing to fit precisely into
the anode support assembly. The table below shows for each supported xenon lamp which anode/cathode
adapters have to be used and if an anode adaptation bushing is required.
4. Lamp & Lamp House
All lamps and adapters in the table below must be used with the XL Lamp House (either m anual or motori
Note that the m aximum lam p power the projector delivers depends on the type of projector and the installed
lamp. Prior to install the lam p it’s important to check with the Communicator software if the lamp is listed in
the list of supported lamps for this projector.
Supported lamp t ypes and their respective anode/cathode adapters for the XL Lamp House:
Lamp type /
Supplier
3000W DHS OFR
OSRAM XBO
4500W DHP-OFR
OSRAM XBO
6000W DHP-OFR
OSRAM XBO
6500W DHP-OFR
OSRAM XBO
DXL-30BA
USHIO
DXL-45BA
USHIO
DXL-60BA2
USHIO
DXL-65BA
USHIO
DXL-65BA2
USHIO
DXL-70BA
USHIO
Cathode adapterAnode adapterAnode adaptation
R8436061KR859987K
R8436081KR859986K
R8436081K
R8436081K
R859984KR859985K
R8436111K
R8436111K
R8436111K
R8436111K
R8436111K
-
-
--
--
--
--
--
bushing
-
-
R864132KR98064901
R864132KR9806860
-
Barco Order No.
R9855950
R9855949
R9855953
R9855952
R9806520
R9855951
R9855962
R9855966
zed).
XDC6500B
PHILIPS
R8436081K
-
R864132KR9856380
WARNING: Always use the right adapter(s) for the xenon lamp. Neglecting this may result in poor perfor-
mance of the lamp and damage to the xen on lamp and Lamp Ho use. Some adapters looks the same, therefore
check the engraved item number upon the ad apter to ensure you uses the right adapter.
R5905963 PROMETHEUS SERIES 09/03/201541
Page 46
4. Lamp & Lamp House
K
Anode adapters a n d adaptation bushing
Image 4-5
R859985KR859986KR859987KR864132
Cathode a dapters for manual Lamp House
Image 4-6
The shortest cathode adapter R8436101K is no longer need ed for xenon lamps supported by Barco. For that this adapter has
become obsolete.
R8436081KR8436101KR8436111KR859984KR8436061K
42
R5905963 PROMETHEUS SERIES 09/03/2015
Page 47
4. Lamp & Lamp House
4.4Removal of the Lamp House
WARNING: This procedure may only be performed by qualified technical service personnel.
WARNING: The Lamp H ouse is very hot after operation. To avoid burns, let the projector cool down for at
least 15 minutes before proceeding to remove the Lamp House.
CAUTION: Du e to its high internal pressure, the lamp m ay explode in either hot or cold states if improperly
handled.
Necessary tools
10mm nut driver or flat screw driver.
How to remove the Lamp House from the projector?
1. M ake sure the projector is switched off and cooled down.
2. R emov e the cover of the Lamp House compartment.
3. R elease the two retaining screws (reference 1 image 4-7) at the base of the Lamp H ouse. Use a 10m m nut driver or a flat screw
driver.
4. Remove the Lamp House as follows:
a) Grip the Lamp House by the bottom handle and partially slide it out of the lamp compartment
b) Grip the Lamp House by both handles and remov e it completely from the projector.
c) Place the Lamp House on a stable support.
Caution:Be aware of the weight of the lamp assembly. Take the necessary precautions to avoid perso nal injury.
1
Image 4-7
This procedure is illustrated with a Motorized Lamp House. Nevertheless, the instructions are also applicable
for the manual Lamp House.
R5905963 PROMETHEUS SERIES 09/03/201543
Page 48
4. Lamp & Lamp House
4.5Removal of the xenon lamp from manual S/M Lamp House
WARNING: DO NOT PERMIT UNAUTHO RIZED PERSONNEL TO PERFORM OR ATTEMPT ANY PHASE O F
XENON LAMP HANDLING OR SERVICE. ONLY TRAINED AND QUALIFIED TECHNICAL SERVICE PERSONNEL
ARE ALLOWED TO HANDLE THE X ENON LAMP.
WARNING: This procedure may only be performed by qualified technical service personnel.
CAUTION: Xenon compact arc lamps are highly pressurized. When ignited, the normal operating temperature
of the bulb increases the pressure to a level at which the bulb may explode if not handled in strict accordance
to the manufacturer’s instructions. The bulb is stable at room temperature, but may still explode if dropped or
otherwise mishandled. Wh enever the lamp house, containing a xenon lamp, has to be dismantled or whenever
the protective container or cloth has to be removed from the xenon lamp , authorized protective clothing MUST
be wo r n!
WARNING: Always we ar face protection (full face shield) when handling xen on lamp s.
WARNING: Always wear protective clothing (welder’s jacket) w hen handling xenon lamps.
WARNING: Always wear clean leather gloves with w rist protectors when handling xenon lamps.
Necessary tools
•5mm Allen wrench.
•Lamp protective container or protective cloth with two binders.
•Flat blade screw driver.
•2.5mm Allen wrench.
How to remove the xenon lamp out of the manual S/M Lamp House?
1. R emov e the hexagon socket head cap screw (reference 1 i
Allen wrench. D o not release the cathode wire lug. The screw contains a spring washer and a plain washer (reference 2 & 3
image 4-8).
Note: The cathode wire remains in its position after the sc
mage 4-8) which fasten the cathode of the xenon lamp. Use a 5 mm
rew and two washers are removed.
3
2
1
Image 4-8
2. Remove the side cover of the Lamp House by releasing the three quarter turn screws (reference 4 image 4-9) of the side cover
as illustrated.
Caution:Ensure that you wear protective clothing, a full face shield and protective gloves.
44
R5905963 PROMETHEUS SERIES 09/03/2015
Page 49
4. Lamp & Lamp House
4
Image 4-9
3. Release the four quarter turn screws (reference 5 image 4-10) of the UV blocker assembly as illustrated. M ake sure that the
anode support remains in its position while releasing t he screws.
5
Image 4-10
4. S upport the xenon lamp inside the Lamp House with one h and while removing the UV blocker assembly from the lamp house.
Warning: Supporting the xenon lamp with one hand prevents the xenon lamp from dropping and colliding with the chassis of
the Lamp H ouse.
Image 4-11
5. S lide out the anode connector f rom the Lamp House. The anode connector remains attached with the lamp anode wire.
Image 4-12
R5905963 PROMETHEUS SERIES 09/03/201545
Page 50
4. Lamp & Lamp House
6. G ently remove the xenon lamp together with the anode socket out of the Lamp House. Do not use excessive force upon the
xenon lamp. Normally the xenon lamp will easily slide ou t the cathode socket of the Lamp House.
Warning: Supporting the xenon lamp with one hand while pulling it out with other hand prevents it from bumping against the
Image 4-13
7. P lace the xenon lamp in its protective container or wrap the xenon lamp in a protective cloth and secure with two binders.
chassis of the Lamp House.
Image 4-14
Left: Xenon lamp wrapped in a protective cloth. Right: Xenon lamp captured in a protective container.
8. Remove the anode wire lug (reference 6 imag e 4-15) from the anode socket as illustrated. Use a 8mm Allen wrench.
Tip:Place the flat washer and bolt (reference 7 & 8 image 4-15) back on its place after the lug is removed.
6
7
8
Image 4-15
46R5905963 PROMETHEUS SERIES 09/03/2015
Page 51
4. Lamp & Lamp House
9. Remove the cathode adap ter from the xenon lamp by releasing the hexagon socket head cap screw (reference 9 image 4-16) of
the adapter as illustrated. Use a 5mm Allen w rench.
Note: Some xenon lamps have a cathode pin with screw threat (reference 10 image 4-16).
109
Image 4-16
Reinstall the UV blocker assembly and the side cover in case you do not intend to install another xenon lamp
immediately in the Lamp House.
CAUTION: Expired xenon lamps.
Dispose of expired bulbs that are beyon d w arranty in the following manner: wrap the bulb tightly in several
layers of canvas or heavy cloth. Place it on hard surface and shatter the envelope w ith a sharp hammer blow.
DO NOT place a non shattered bulb in any ordinary refuse container.
CAUTION: Small amounts of radioactive material (< 1000 Bq per lamp) are deliberately added to Xenon lamps
for functional reas ons. These lamps are manufactured under reg ulatory control as consumer product according to IAEA basic safety standard BS S 115. Disposal according to national regulations is required e.g. in
Europe covered by W EEE regulation. See also related user manual of the lamp supplier for more guidance.
When returning a xenon lamp for warranty adjustment, pack it in its original shipping container. Complete
and return all required warranty information.
R5905963 PROMETHEUS SERIES 09/03/201547
Page 52
4. Lamp & Lamp House
4.6Removal of the xenon lamp from manual XL Lamp House
WARNING: DO NOT PERMIT UNAUTHO RIZED PERSONNEL TO PERFORM OR ATTEMPT ANY PHASE O F
XENON LAMP HANDLING OR SERVICE. ONLY TRAINED AND QUALIFIED TECHNICAL SERVICE PERSONNEL
ARE ALLOWED TO HANDLE THE X ENON LAMP.
WARNING: This procedure may only be performed by qualified technical service personnel.
CAUTION: Xenon compact arc lamps are highly pressurized. When ignited, the normal operating temperature
of the bulb increases the pressure to a level at which the bulb may explode if not handled in strict accordance
to the manufacturer’s instructions. The bulb is stable at room temperature, but may still explode if dropped or
otherwise mishandled. Wh enever the lamp house, containing a xenon lamp, has to be dismantled or whenever
the protective container or cloth has to be removed from the xenon lamp , authorized protective clothing MUST
be wo r n!
WARNING: Always we ar face protection (full face shield) when handling xen on lamp s.
WARNING: Always wear protective clothing (welder’s jacket) w hen handling xenon lamps.
WARNING: Always wear clean leather gloves with w rist protectors when handling xenon lamps.
Necessary tools
•Two open-end wrenches of 22mm.
•5mm Allen wrench.
•Lamp protective container or protective cloth with two binders.
•Flat blade screw driver.
•2.5mm Allen wrench.
How to remove the xenon lamp out of the manual XL Lamp House?
1. Remove the hexagon socket head cap screw (reference 1 image 4-17) which fastens the cathode of the xenon lamp. Use a 5
mm Allen wrench. Do not release t he cathode wire lug. The screw contains a spring washer and a plain washer (reference 2 &
3 image 4-17).
Note: The cathode wire remains in its position after the screw and two washers are removed.
3
2
1
Image 4-17
2. Remove the side cover of the Lamp House by releas ing the three quarter turn screws (reference 4 image 4-18) of the s ide cover
as illustrated.
Caution:Ensure that you wear protective clothing, a full face shield and protective gloves.
48
R5905963 PROMETHEUS SERIES 09/03/2015
Page 53
4. Lamp & Lamp House
4
Image 4-18
3. Release the four quarter turn screws (reference 5 image 4-19) of the UV blocker assembly as illustrated. M ake sure that the
anode support remains in its position while releasing t he screws.
5
Image 4-19
4. S upport the xenon lamp inside the Lamp House with one h and while removing the UV blocker assembly from the lamp house.
Warning: Supporting the xenon lamp with one hand prevents the xenon lamp from dropping and colliding with the chassis of
the Lamp H ouse.
Image 4-20
5. S lide out the anode connector f rom the Lamp House. The anode connector remains attached with the lamp anode wire.
Image 4-21
R5905963 PROMETHEUS SERIES 09/03/201549
Page 54
4. Lamp & Lamp House
6. G ently remove the xenon lamp together with the anode socket out of the Lamp House. Do not use excessive force upon the
xenon lamp. Normally the xenon lamp will easily slide ou t the cathode socket of the Lamp House.
Warning: Supporting the xenon lamp with one hand while pulling it out with other hand prevents it from bumping against the
Image 4-22
7. P lace the xenon lamp in its protective container or wrap the xenon lamp in a protective cloth and secure with two binders.
chassis of the Lamp House.
Image 4-23
Left: Xenon lamp wrapped in a protective cloth. Right: Xenon lamp captured in a protective container.
8. R emov e the anode wire lug (reference 7 ima ge 4-24) from the anode socket. Use for that two open ended spanners of 22 mm.
Hold the first nut (reference 5) with one spanner while releasing the second nut (reference 9 image 4-24) with the other spanner.
Tip:Place the flat washer and the nut back on the rod after the lug is removed.
50R5905963 PROMETHEUS SERIES 09/03/2015
Page 55
4. Lamp & Lamp House
56789
Image 4-24
9. Remove the cathode adapter from the xenon lamp by releasing the hexagon socket head set screw (reference 9 image 4-25) of
the adapter as illustrated. Use a 2.5mm Allen wrench.
Note: Some xenon lamps have a cathode pin with screw threat (reference 10 image 4-25.
10
9
Image 4-25
10.Remove the anode adapter from the xenon lamp by releasing the hexagon socket head set screw (reference 13 image 4-26) of
the lamp adapter as illustrated. Use for that a 2.5mm Allen wrench.
13
Image 4-26
R5905963 PROMETHEUS SERIES 09/03/201551
Page 56
4. Lamp & Lamp House
Reinstall the UV blocker assembly and the side cover in case you do not intend to install another xenon lamp
immediately in the Lamp House.
CAUTION: Expired xenon lamps.
Dispose of expired bulbs that are beyon d w arranty in the following manner: wrap the bulb tightly in several
layers of canvas or heavy cloth. Place it on hard surface and shatter the envelope w ith a sharp hammer blow.
DO NOT place a non shattered bulb in any ordinary refuse container.
CAUTION: Small amounts of radioactive material (< 1000 Bq per lamp) are deliberately added to Xenon lamps
for functional reas ons. These lamps are manufactured under reg ulatory control as consumer product according to IAEA basic safety standard BS S 115. Disposal according to national regulations is required e.g. in
Europe covered by W EEE regulation. See also related user manual of the lamp supplier for more guidance.
When returning a xenon lamp for warranty adjustment, pack it in its original shipping container. Complete
and return all required warranty information.
52R5905963 PROMETHEUS SERIES 09/03/2015
Page 57
4.7Installation of the xenon lamp in manual S/M Lamp House
WARNING: DO NOT PERMIT UNAUTHO RIZED PERSONNEL TO PERFORM OR ATTEMPT ANY PHASE O F
XENON LAMP HANDLING OR SERVICE. ONLY TRAINED AND QUALIFIED TECHNICAL SERVICE PERSONNEL
ARE ALLOWED TO HANDLE THE X ENON LAMP.
WARNING: This procedure may only be performed by qualified technical service personnel.
CAUTION: Xenon compact arc lamps are highly pressurized. When ignited, the normal operating temperature
of the bulb increases the pressure to a level at which the bulb may explode if not handled in strict accordance
to the manufacturer’s instructions. The bulb is stable at room temperature, but may still explode if dropped or
otherwise mishandled. Wh enever the lamp house, containing a xenon lamp, has to be dismantled or whenever
the protective container or cloth has to be removed from the xenon lamp , authorized protective clothing MUST
be wo r n!
WARNING: Always we ar face protection (full face shield) when handling xen on lamp s.
4. Lamp & Lamp House
WARNING: Always wear protective clothing (welder’s jacket) w hen handling xenon lamps.
WARNING: Always wear clean leather gloves with w rist protectors when handling xenon lamps.
This procedure assumes that the anode support assembly and the side cover are already removed from the
Lamp House due to the removal of the xenon lamp.
Necessary tools
•Torque wrench with a 2 ,5 mm Allen socket.
•Torque Allen key
•1,5 mm A llen wrench.
•22 mm open-end wrench.
•Torque wrench with a 22 mm hexagon socket.
•Torque wrench with a 5 mm Allen socket.
How to install the xenon lamp in the manual S/M Lamp House?
1. Install the lamp c athode adapter on the cathode of the xenon lamp. Note that some xenon lamps have a cathode pin with screw
threat (reference 10 image 4-27). Screw the adaptor on the anode pin as far as possible. Make sure that there is full contact
between the adapter flat surface and the lamp base. Fasten the set screw (reference 9 image 4-27) of the cathode adapter with
a torque of 2.5Nm (1.84 lbf*ft). Use a torque wrench with a 5mm Allen socket.
Caution:Ensure that the adaptor is clean. Periodically clean the adapter. Remove o xide from silver plated adaptor with
Warning: Install the cathode adapter prior to removing the protective container or protective cloth from the xenon lam p.
standard household metal polish (E.g. Brasso).
R5905963 PROMETHEUS SERIES 09/03/2015
53
Page 58
4. Lamp & Lamp House
9
10
2.5Nm
Image 4-27
2. Install the anode wire lug (reference 6 image 4- 28) upon the anode socket as illustrated. Use an 8mm Allen torque key set to
9Nm (6.64lbf*ft) to s ecure the bolt (reference 8 image 4-28). P lace a flat washer (reference 7 image 4-28) between the bolt and
thewirelug.
Warning: Make sure that there is no tension on the anode wire of the xenon lamp.
6
7
8
9Nm
Image 4-28
Tip:Write down the serial num ber of the xenon lamp. You will need this w hile updating the lamp parameters after installation
of the xenon lamp. T he serial numb
3. C heck the c athode connection inside the lamp house. Use an 22 mm open-end wrench to hold the first nut while fastening the
second nut on the rod with a torque of 25Nm (18.4 lbf*ft) using a torque wrench with 22 mm hexagon socket. Ensure that there
is a flat washer at both s ides of the wire lug. It’s safer to do this check be fore the xenon lamp is installed to avoid accidental
bumping against the xenon lamp.
Tip:The cathode socket can easily pulled ou t from the Lamp House as a whole to perform this check.
Caution:These cathode connections must be checked with every lamp change!
er of the xenon lamp is engraved in the neck of the x enon lamp.
25 Nm
Image 4-29
54R5905963 PROMETHEUS SERIES 09/03/2015
Page 59
4. Lamp & Lamp House
4. R emov e the protective packing from the xenon lamp and gently insert the xenon lamp into the Lamp House as illustrated. Lamp
cathode first, Make sure that the wire of the lamp anode is upwards oriented. W hile inserting the lam p, rotate it slightly, engagingthe pins (reference 11 image 4-30) of the cathode adapter in the foreseen slots. This is to ensure the lamp cathode is completely
inserted. Keep supporting the anode of the lam p with one hand once the xenon lamp is in position.
Caution:Ensure that you wear protective clothing, a full face shield and protective gloves.
11
Image 4-30
5. S lide t he anode connector in its position on the Lamp House as illustrated.
Caution:Avoid any tension on the anode wire, ensuring there is no mechanical stress on the lamp.
Image 4-31
6. Install the UV blocker assembly as illustrated. Use the opening at the side of the Lamp House to guide the anode pin of the
xenon lamp into the anode supporting mechanism of the UV blocker.
Image 4-32
7. S e cure the UV blocker by fastening the four quarter turn screws (reference 5 image 4-33) as illustrated.
Note: Ensure that the qua
rter turn screws turning wires are flush with the cover or interference will occur while inserting the
Lamp House into the projector.
R5905963 PROMETHEUS SERIES 09/03/2015
55
Page 60
4. Lamp & Lamp House
5
Image 4-33
8. Install the side cover of the Lamp House and fasten the three quarter turn screws (reference 4 image 4-34) of the cover.
Note: Please ensure that the quarter turn screws turning wires are flush with the cover or interferenc
the Lamp House into the projector.
e w ill occur while inserting
4
Image 4-34
9. S ecure the xenon lamp cathode with the hexagon socket head cap screw (reference 1 image 4-35), spring washer (reference 2
image 4-35) and plain wa sher (reference 3 image 4-35). F asten the screw with a torque of 5Nm(3,7 lbf*ft). Use a torque wrench
with a 5 mm Allen socket.
Caution:Make sure that both pins (reference 11 image 4-35) of the cathode adapter remain engaged in the foreseen slots.
3
2
1
5 Nm
11
Image 4-35
CAUTION: The “LAMP INFO” parameters which are stored on a ch ip inside the Lamp House MUST be updated
after each installation of an xenon lamp inside the Lamp House. Neglecting this update will result in poor
performance and short life time of the xenon lamp .
56R5905963 PROMETHEUS SERIES 09/03/2015
Page 61
4. Lamp & Lamp House
A realignment of the xenon lamp in its reflector is req uired after the installation of the xenon lamp in the Lamp
House.
R5905963 PROMETHEUS SERIES 09/03/201557
Page 62
4. Lamp & Lamp House
4.8Installation of the xenon lamp in manual XL Lamp House
WARNING: DO NOT PERMIT UNAUTHO RIZED PERSONNEL TO PERFORM OR ATTEMPT ANY PHASE O F
XENON LAMP HANDLING OR SERVICE. ONLY TRAINED AND QUALIFIED TECHNICAL SERVICE PERSONNEL
ARE ALLOWED TO HANDLE THE X ENON LAMP.
WARNING: This procedure may only be performed by qualified technical service personnel.
CAUTION: Xenon compact arc lamps are highly pressurized. When ignited, the normal operating temperature
of the bulb increases the pressure to a level at which the bulb may explode if not handled in strict accordance
to the manufacturer’s instructions. The bulb is stable at room temperature, but may still explode if dropped or
otherwise mishandled. Wh enever the lamp house, containing a xenon lamp, has to be dismantled or whenever
the protective container or cloth has to be removed from the xenon lamp , authorized protective clothing MUST
be wo r n!
WARNING: Always we ar face protection (full face shield) when handling xen on lamp s.
WARNING: Always wear protective clothing (welder’s jacket) w hen handling xenon lamps.
WARNING: Always wear clean leather gloves with w rist protectors when handling xenon lamps.
This procedure assumes that the anode support assembly and the side cover are already removed from the
Lamp House due to the removal of the xenon lamp.
Necessary tools
•Torque wrench with a 2.5mm Allen socket.
•1.5mm Allen wrench.
•22mm open-end wr ench.
•Torque wrench with a 22m m hexagon socket.
•Torque wrench with a 5mm Allen s ocket.
How to install the xenon lamp in the manual XL Lamp House?
1. Install the appropriate lamp cathode adapter on the cathode of the xenon lamp. N o te that some xenon lam ps have a cathode
pin with screw threat (reference 10 image 4-36). Screw the adaptor on the anode pin as far as possible. Make sure that there is
full contact between the adapter flat surface and the lamp base. Fasten the set screw (reference 9 image 4-36) of the cathode
adapter with a torque of 2.5Nm (1.84 lbf*ft). Use a torque wrench with a 2.5mm Allen socket.
Tip:See s upported xenon bulb lamps to know which cathode adapter your lamp requires.
Caution:Ensure that the adaptor is clean. Periodically clean the adapter. Remove o xide from silver plated adaptor with
Warning: Install the cathode adapter prior to remov
standard household metal polish (E.g. Brasso).
ing the protective container or protective cloth from the xenon lamp.
58
R5905963 PROMETHEUS SERIES 09/03/2015
Page 63
4. Lamp & Lamp House
10
9
2.5Nm
Image 4-36
2. Requires the xenon lamp an anode adapter?
Tip:See supported xenon bulb lamps to know if your lamp requires an anode adapter.
If yes, install the appropriate lamp anode adapter on the anode of the xenon lamp. Fasten the set screw (reference 13 image 4-3 7)
of the anode adapter with a torque of 2.5Nm (1.84 lbf*ft). Use a torque wrench with a 2.5mm Allen socket. Make sure that there
is full contact between the adapter flat surface and the lamp base.
2.5Nm
13
Image 4-37
If no, make sure that there is no anode adapter installed on the anode of the xenon lamp.
3. Install the anode wire lug (reference 7 image 4-38) on the anode socket of the Lamp House as illustrated. Use an open-end
wrench of 22 mm t o hold the first nut (reference 5 image 4-38) while fastening the second nut (reference 9 image 4-38) with a
torque of 25Nm (18.4 lbf*ft) using a torque wrench. Ensure that there is a fl at washer (reference 6 & 8 im age 4-38) at both sides
of the wire lug (reference 7 image 4-38).
Warning: A torque of 25Nm (18.4 lbf*ft) must be applied to fasten the nuts. Make sure that there is no tension on the anode
Note: Alter tightening the two nuts, the co
wire of the xenon lamp.
nnector should still be “floating”.
R5905963 PROMETHEUS SERIES 09/03/2015
59
Page 64
4. Lamp & Lamp House
56789
Image 4-38
Tip:Write down the serial num ber of the xenon lamp. You will need this w hile updating the lamp parameters after installation
of the xenon lamp. T he serial number of the xenon lamp is engraved in the neck of the xenon lamp.
4. C heck the c athode connection inside the lamp house. Use an
second nut on the rod with a torque of 25Nm (18.4 lbf*ft) using a torque wrench with 22 mm hexagon socket. Ensure that there
is a flat washer at both s ides of the wire lug. It’s safer to do this check be fore the xenon lamp is installed to avoid accidental
bumping against the xenon lamp.
Tip:The cathode socket can easily pulled ou t from the Lamp House as a whole to perform this check.
Caution:These cathode connections must be checked with every lamp change!
25 Nm
22 mm open-end wrench to hold the first nut while fastening the
25 Nm
Image 4-39
5. C heck the c athode connection inside the lamp house. Use an 22 mm open-end wrench to hold the first nut while fastening the
second nut on the rod with a torque of 25Nm (18.4 lbf*ft) using a torque wrench with 22 mm hexagon socket. Ensure that there
is a flat washer at both sides of the wire lug.
Caution:These cathode connections must be checked with every lamp change!
6. Requires the lamp an anode adaptation bushing inside the anode support?
Tip:See supported xenon bulb lamps to know if your lamp requires an anode adaptation bushing.
60
R5905963 PROMETHEUS SERIES 09/03/2015
Page 65
4. Lamp & Lamp House
If yes, insert the anode adaptation bushing (reference 12 image 4-40 and image 4-43) into the integrated anode support of the
UV blocker.
If no, make sure that there is no anod e adaptation bushing inserted into the anode support.
12
Image 4-40
7. R emov e the protective packing from the xenon lamp and gently insert the xenon lamp into the Lamp House as illustrated. Lamp
cathode first, Make sure that the wire of the lamp anode is upwards oriented. W hile inserting the lam p, rotate it slightly, engagingthe pins (reference 11 image 4-41) of the cathode adapter in the foreseen slots. This is to ensure the lamp cathode is completely
inserted. Keep supporting the anode of the lam p with one hand once the xenon lamp is in position.
Caution:Ensure that you wear protective clothing, a full face shield and protective gloves.
Tip:Write down the serial num ber of the xenon lamp. You will need this w hile updating the lamp parameters after installation
of the xenon lamp. T he serial number of the xenon lamp is engraved in the neck of the xenon lamp.
Image 4-41
8. S lide t he anode connector in its position on the Lamp House as illustrated.
Caution:Avoid any tension on the anode wire, ensuring there is no mechanical stress on the lamp.
11
Image 4-42
9. Install the UV blocker assembly as illustrated. Use the opening at the side of the Lamp House to guide the anode pin of the
xenon lamp into the anode supporting mechanism of the UV blocker.
R5905963 PROMETHEUS SERIES 09/03/2015
61
Page 66
4. Lamp & Lamp House
12
Image 4-43
10.Secure the UV blocker by fastening the four quarter turn screws (reference 5 image 4-44) as
Note: Ensure that the quarter turn screws turning wires are flush with the cover or interference will occur while inserting the
Lamp House into the projector.
illustrated.
5
Image 4-44
11.Install the side cover of the Lamp House and fasten the three quarter turn screws (reference 4 image 4-45) of the cover.
Note: Please ensure that the quarter turn screws turning wires are flush with the cover or interference will occur while inserting
the Lamp House into the projector.
4
Image 4-45
12.Secure the xenon lam p cathode with the hexagon s ock et head cap screw (reference 1 image 4-46), spring washer (reference 2
image 4-46) and plain wa sher (reference 3 image 4-46). F asten the screw with a torque of 5Nm(3,7 lbf*ft). Use a torque wrench
with a 5 mm Allen socket.
Caution:Make sure that both pins (reference 11 image 4-46) of the cathode adapter remain engaged in the foreseen slots.
62
R5905963 PROMETHEUS SERIES 09/03/2015
Page 67
Image 4-46
4. Lamp & Lamp House
3
2
1
5 Nm
11
CAUTION: The “LAMP INFO” parameters which are stored on a ch ip inside the Lamp House MUST be updated
after each installation of an xenon lamp inside the Lamp House. Neglecting this update will result in poor
performance and short life time of the xenon lamp .
A realignment of the xenon lamp in its reflector is req uired after the installation of the xenon lamp in the Lamp
House.
R5905963 PROMETHEUS SERIES 09/03/201563
Page 68
4. Lamp & Lamp House
4.9Check if anode support must be provided with a plain washer
Necessary tools
•2.5mm Allen wrench.
•19mm open-end wr ench.
Necessary parts
Plain washer, stainless steel, ØD = 18m m, Ø d = 6.4mm , thickness = 1.6mm. (V3673807).
How to check if the anode support must be provided w ith a plain washer?
1. Turn the thumbscrew of the Z direction counterclockwise as for as possible (minimum Z position of the xeno n lamp).
2. Check if the anode pin of the xenon lamp remains supported by the anode support.
Image 4-47
3. In case the anode pin drops out the anode support place a plain washer (reference 3) between the UV blocker and anode support
(reference 4). Use a 2.5mm Allen wrench to loosen/fasten the screw (reference 1) of the anode support. Use a 19mm open-end
wrench to capture the anode support.
1
2
3
4
Image 4-48
64R5905963 PROMETHEUS SERIES 09/03/2015
Page 69
4. Lamp & Lamp House
4.10 Installation of the Lamp House
WARNING: This procedure may only be performed by qualified technical service personnel.
CAUTION: Du e to its high internal pressure, the lamp m ay explode in either hot or cold states if improperly
handled.
Necessary tools
10mm nut driver or flat screw driver.
How to install the Lamp House in the projector?
1. C heck if the six quarter turn screws turning wires (reference 1image 4-49) are flush w ith the cover or interference will occur while
inserting the Lamp H ouse into the projector.
1
Image 4-49
2. G rip the Lamp House by both handles and place the front of the Lamp House on the base plate inside the lamp compartment of
4. S ecure the Lamp House by fastening the two retaining screws (reference 1 image 4-50) at the bas e of the Lamp House.
5. Reinstall the cover of the Lamp Hous e compartment.
1
Image 4-50
R5905963 PROMETHEUS SERIES 09/03/201565
Page 70
4. Lamp & Lamp House
4.11 Resetting the lamp parameters
CAUTION: The “LAMP INFO” parameters MUST be u pdated after each installation of a xenon lamp inside the
Lamp House. Neglecting this update will result in poor performance and short life time of the xenon lamp.
For a new lamp, how to reset the values
1. While the Lamp information window is displayed, click on Change lamp (1).
A Reset lamp parameters selection window opens (2).
2. To get new lamps, click on From new list (3).
The lamp article and serial number opens (4).
3. F ill out the article number of the new lamp (5a)
Or,
click on Select (5b) to display a list of possible article numbers (6). Select a article number (7) and click OK (8).
The software will check if the entered article number is a valid number (9).
4. F ill out the serial number of the lamp (10).
5. Click Reset lamp (11).
For a used lamp, how to set back the original values
1. While the Lamp information window is displayed, click on Change lamp (1).
A Reset lamp parameters window opens (2).
2. To get history of the used lamps, click from history (3 ).
The Reset lamp history selection window opens (4).
3. Click on Select (5) to display a list of possible lamps (6).
4. S elect the desired lamp (7) and click OK (8 ).
The article number and serial number of the selected lamp is added to the Reset lamp parameters window (10). The lamp run
time and number of strikes of this lamp are added in Lamp parameter preview (12).
5. T he lamp parameters can be edited by the user under personnel maintenance and responsibility. If you want to change these
parameters, check the check box in front of Edit lamp parameters (11).
The current parameter fields become active (12).
6. Click in an input field and change to the desired value.
7. Click Reset lamp (13).
66
R5905963 PROMETHEUS SERIES 09/03/2015
Page 71
4. Lamp & Lamp House
4.12 Realignment of the lamp in its reflector (manual Lamp House)
Each xenon lamp installation requires a realignment of the lamp in its reflector for optimal performance of the
xenon lamp in the Prometheus. Furthermore, it is reco mmended t o realign the lamp after the first run time of
100 and 200 hours. Especially the Z-axis of the lamp.
How to realign
1. Remove the lam p cover to get access to the X-, Y- and Z-axis adjus tment thumbscrews of the lamp.
2. S om e lamp houses may have lock nuts on the X and Y adjustment screws which are locked. Before starting the adjustment, fully
turn these lock nuts against the thumbscrew.
Image 4-51
Lock nuts
3. S w itch on the projector and start up the lamp.
4. G o via the Communicator touch panel to the menu “Installati on” > “Lamp” > “Light output”.
5. S et the “Light output mode”innormal mode and the “Lamp Dimming” on maximum (255).
Note: This window on the Communicator touch panel shows in the upper left corner the measured value of the built-in light
sensor of the projector.
Image 4-52
Light mode selectio n
R5905963 PROMETHEUS SERIES 09/03/201567
Page 72
4. Lamp & Lamp House
6. A djust the X-axis (ref X image 4-53), the Y-axis (ref Y image 4-53) and the Z-axis (ref Z image 4-53) for maximum current light
output (Footlambert Measur ed). Carefully turn the thumbscrew for maxim um light output. Once over the maximum, t urn slightly
in opposite direction to reach the maxim um light output again. Do this for each dire ction and repeat this ad justment cycle twice.
Y
Z
X
Image 4-53
Realignment points
7. If lock nuts are available, these nuts can be locked again.
8. S w itch of the projector.
9. Reinstall the lamp cover.
68
R5905963 PROMETHEUS SERIES 09/03/2015
Page 73
5. Lenses & lens holder
5. LENSES & LENS HOLDER
About this chapter
This chapter gives an overview of available lenses for the Prometheus and e xplains how you can select the best suited lens for your
specific situation using the lens calculator. Also, it is explained how to install and remove a lens from the projector lens holder and
how you can shift, zoom and focus the lens. Furthermore, it is described how you can perform the Scheimpfl ug ad justment.
CAUTION: Never transport the projector with a Lens mounted in the Lens Holder. Always remove the Le
before transporting the p rojector. Neglecting this can damage the Lens Holder and Prism.
Each time a lens is manipulated (e.g. removed an d installed in a p rojector), it needs to be homed and returned.
Overview
•Available lenses
•Lens selection
•Lens installation
•Lens removal
•Lens shift, zoom & focus
•Back Focal Length adjustment
•Scheimpflug adjustment
•Fixation of the Lens Holder front plate
ns
R5905963 PROMETHEUS SERIES 09/03/2015
69
Page 74
5. Lenses & lens holder
5.1Available lenses
Which lenses are available for my projector?
The table below is subject to changes and was last u pda ted on 15/04/2013. Consult Barco ’s w eb site and click
on myBarco for the most recent information about available lenses.
Product Number2K zoom range4K zoom rangeImage
R98559581,25 – 1,451,13 – 1,31image 5-1
R98559421,45 – 2,051,32 – 1,86image 5-2
R9856294
R98559431,6 – 2,351,45 – 2,13image 5-4
R9856297
R98559631,6 – 2,351,45 – 2,13image 5-6
R98559451,8 – 2,81,63 – 2,53image 5-7
R98559641,8 – 2,81,63 – 2,53image 5-8
R9856300
R98559462,15 – 3,61,95 – 3,26image 5-10
R98559472,8 – 5,52,53 – 4,98image 5-11
R98562941,49 – 2,051,35 – 1,86image 5-12
R98562971,61 – 2,311,46 – 2,10image 5-13
R98563001,82 – 2,861,65 – 2,60image 5-14
1
1
1
1,49 – 2,051,35 – 1,86image 5-3
1,6 – 2,311,46 – 2,10image 5-5
1,82 – 2,861,65 – 2,60image 5-9
Image 5-1
R9855958
Image 5-4
R9855943
1. Typical 4K lenses with focus adjustment on the lens and not on the lens holder
Image 5-2
R9855942
Image 5-5
R9856297
Image 5-3
R9856294
Image 5-6
R9855963
70R5905963 PROMETHEUS SERIES 09/03/2015
Page 75
5. Lenses & lens holder
Image 5-7
R9855945
Image 5-10
R9855946
Image 5-8
R9855964
Image 5-11
R9855947
Image 5-9
R9856300
Image 5-12
R9856294
Image 5-13
R9856297
Image 5-14
R9856300
R5905963 PROMETHEUS SERIES 09/03/201571
Page 76
5. Lenses & lens holder
5.2Lens selection
WhichlensdoIneed?
1. G o to Barco’s website on www.barco.com and click on myBarco
2. L ogin on.
If yo u are not yet registered create a login a nd password. With the created login and password, it is possible to enter myBarco.
When your login is correct, the start page is displayed.
3. Click the Support tab, then Digital cinema calculator (on the left of the screen) and select the appropriate lens calculator.
The lens calculator (see screenshot, image 5-15) will be displayed.
The lens calculator allows you to have an overview of which lenses are suitable for your specific projector setup. Jus t make your
selection of parameters and all possible configurations are displayed.
Image 5-15
Digital cinema lens calculator
Take into account that w hen the projector is tilted the Screen Width you have to fill in should be larger than
the physical screen width due to the keystone distortion of the projected image. How much larger depends
ontheamountoftilt.
Due to production tolerances the real distances can differ by 2% from the calculated values.
For critical situations ( fixed installs that use the lens at one of its extreme zoom positions) this should be
taken into account.
72R5905963 PROMETHEUS SERIES 09/03/2015
Page 77
5.3Lens installation
How to install a lens?
1. Remove the plastic lens holder cover.
a) Put the lock (1) into the unlock position.
b) Take ou t the plastic cover.
5. Lenses & lens holder
12
Image 5-16
2. Take the lens assembly out of its packing material and remove the lens caps on both sides.
3. P lace the lens holder in the “unlocked” position by moving the lens lock handle (1) towards the lens power supply socket (2).
3
2
1
12
Image 5-17
Unlock lens holder
4. E nsur e that the lens holder stands in the On-Axis position (horizontal and vertical mid position).
Note: The lens holder is placed default in the On-Axis position at factory.
5. G ently insert the lens in such a way that the lens connector matches the socket.
R5905963 PROMETHEUS SERIES 09/03/2015
73
Page 78
5. Lenses & lens holder
Image 5-18
Mount lens
6. Insert the lens until the connector seats into the s ocket.
- the pin (3) on the lens holder matches with the sleeve in the lens.
- the connector seats into the socket (2)
Warning: Do not release the Lens yet, as the Lens may fall out of the Lens Holder.
7. S ecur e the lens in the lens holder by sliding the lens lock handle into t he “locked” position, which is away from the lens power
supply socket. Ensur e the lens touches the front plate of the lens holder.
Image 5-19
Fix lens
8. A ctivate the corresponding lens parameters for the installed lens. (See user guide of the Com munic ator chapter Installation >
Advanced > Lens parameters)
Caution:Not using the correct lens parameters could result in lens dam age.
Image 5-20
74R5905963 PROMETHEUS SERIES 09/03/2015
Page 79
5. Lenses & lens holder
9. P erform a lens H OME & RETURN operation. (See user guide of the Communicator chapter Installation > Advanced > Lens
parameters)
Note: The HOME & RETURN operation enables the projector to determine the reference positions of the motorized ZOOM and
FOCUS of the installed lens.
For the lenses with a focus adjustm ent mounted on the lens (4K lenses) , the lens holder goes to a normal (fixed) focus
position. For these lenses, do not mechanically adjust the focus position of the lens holder, otherwise the normal pos ition
will be lost.
CAUTION: Never transport the projector with a Lens mounted in the Lens Holder. Always remove the Lens
before transporting the p rojector. Neglecting this can damage the Lens Holder and Prism.
R5905963 PROMETHEUS SERIES 09/03/201575
Page 80
5. Lenses & lens holder
5.4Lens removal
How to remove a lens?
1. S upport the lens with one hand while you unlock the lens holder by sliding the lock handle towards the “unlocked” position as
illustrated.
Image 5-21
Unlock lens
2. G ently pull the lens out of the lens holder.
Image 5-22
Remove lens
It’s recommended to place the Lens caps of the original Lens packaging, back on both sides o f the removed
Lens to protect the optics of the Lens.
It’s recommended to place the foam rubber of the original projector packaging, back into the Lens opening to
prevent intrusion of dust. Note that this foam rubber is packed in a plastic bag to p revent the dust, emitted by
the foam , from e ntering the projector.
76R5905963 PROMETHEUS SERIES 09/03/2015
Page 81
5. Lenses & lens holder
5.5Lens shift, zoom & focus
Motorized lens adjustment
The Prometheus is equipped with a motorized lens shift functionality and a motorized zoom & focus functionality.
Maximum shift range
The lens can be sh ifted with respect to the DMD which result in a shifted image on the screen (Off-Axis). A 100% shift means that
the centre point of the projected image is shifted by half the screen size. In other words, the centre point of the projected image falls
together with the outline of the image in an On-Axis projec tion. Due to mechanical an optical limitations the shift range is limited as
well.
All DP2K lenses ha ve a shift range of 50% up/down and 30% left/right. This range is valid for all throw ratios.
How to shift the lens of the Prometheus?
1. U se the up and down arrow keys on the local keypad to shift the lens vertically and use the left and right arrow keys on the
local keypad to shift the lens horizontally.
Image 5-23
How to zoom in or out?
1. Is the zoom lens equipped with a motorized zoom?
If yes, use the “+” and “-” zoom keys on the local keypad to zoom in or out.
Image 5-24
If no, use the zoom barrel on the lens to zoom in or out.
How to focus?
1. U se the “+” and “-” focus keys on the local keypad to focus the image on the screen.
Image 5-25
Take into account that the lens focus may slightly drift while the lens is warming up from cold to operation
temperature. This is a typical phenomen on for projection lenses used with high brightness projectors. The
operation tem pe rature of the lens is reached after approximately 30 minutes p rojection of average video.
R5905963 PROMETHEUS SERIES 09/03/201577
Page 82
5. Lenses & lens holder
2
5.6Back Focal Length adjustment
When to adjust the Back Focal Length?
If a lens is used with a throw ratio suited for the application, (lens selection depends on projection distance and screen size) typically
one would NEVER need to adjust the Back Focal Length of the projector.
A Back Focal Length adjustment is only required in case the F ocus range of the installed lens does not capture the projection
screen either for FLAT and/or for S COPE. In other words, when it is impossible to focus the image on the screen for FLAT and/or
for SCOPE. Note that the lenses for the Prometheus are varifocal. S o, switching between FLAT and SCOPE (z oom action) requires
a readjustment of the focus.
What is Back Focal Length adjustment?
Back Focal Length adjustment means moving the lens plane (Lp), thus the Lens Holder front plate, closer to or further from the DMD
plane. The closer the lens plane to the DM D plane the further the focus range (Fr) of the lens will b
e.
Lp1
Lp2
DMD
Image 5-26
Do not abuse the Back Focal Length adjustment of the Lens Holder. Neglecting this will result in loss of image
quality because of the lens design. Cas es requiring Back Focal Length adjustment normally indicate incorrect
lens choice (throw ratio).
Fr1
Fr
SCREEN
Necessary tools
•Nut driver 10mm.
•Allen wrench 3mm.
•Nut driver 13mm.
How to check the Back Focal Length
1. E nsure that the throw ratio of the installed lens matches with the requirements of the application (projection distance and screen
size).
2. E nsure that the correct lens parameters are activated. (See user guide of the Communicator chapter Installation > Advanced >
Lens parameters)
Caution:Not using the correct lens parameters could result in lens dam age.
3. P erform a lens H OME & RETURN operation. (See user guide of the Communicator chapter Installation > Advanced > Lens
parameters)
4. P roject the green focus test pattern. (screen fi
le “no masking” or “no “crop”)
Image 5-27
5. Z oom the lens for maximum image on the screen (WIDE).
6. Is it possible to focus the center of the projected image?
If yes, the Bac k Focal Length is OK .
If no, the Back Focal Length needs realignment. Proceed with the next procedure.
78
R5905963 PROMETHEUS SERIES 09/03/2015
Page 83
5. Lenses & lens holder
How to adjust the Back Focal Length?
1. Unlock and loosen the 4 set s crews (reference 11 image 5-28) of the Lens Holder by 1 centimeter. Use a 10mm nut driver for
the lock nuts (reference 21 im age 5-28) and use a 3mm Allen wrench for the set screws.
11
1121
Image 5-28
2. F ully loosen the Scheimpflug nut at the lower left of the Lens Holder (reference 4 image 5-29). Use a 13mm nut driver.
4
4
Image 5-29
3. Turn the three S cheimp flug adjustment n
is equally aligned with the front of the threaded rod (reference 6 im age 5-30). U s e a 13mm nut driver.
Note: This is the nominal pos ition of the Lens Holder.
1
4
uts, reference 1, 2 and 3 image 5-30, until the front of the nut (reference 5 image 5-3 0)
2
1
2 3
3
3 x
x
5
6
Image 5-30
4. Z oom the lens for maximum image on the screen (WIDE) and focus the center of the projected image using the motorized focus
control (Local Keypad).
R5905963 PROMETHEUS SERIES 09/03/2015
79
Page 84
5. Lenses & lens holder
F
FOCUS
Image 5-31
5. Is it possible to focus the center of the projected image using the motorized focus control (Local Keypad) ? Ensure that the lens
is zoomed for maximum image on the sc reen (WIDE).
If yes, nominal po sition is good for sharp focus in the middle of the projected image. Proceed wi
If no, obtain the best possible focus in the center of the projected imag e using the motorized focus control and then turn the
three Scheimpflug adjustment nuts, reference 1, 2 and 3 image 5-32, equally in o r out until the center of the projected image is
sharp. Attention: Keep in mind the turning direction of the Scheimpflug adjustment nuts for
this procedure.
1
2
3
F
th step 6 .
further adjustment instructions in
Image 5-32
6. Z oom the lens for minimum image on the screen (TELE) and focus the center of the projected image using the motorized focus
control (Local Keypad).
F
FOCUS
Image 5-33
7. Is it possible to focus the center of the projected image using the motorized focus control (Local Keypad) ? Ensure that the lens
is zoomed for minimum image on the screen (TELE).
If yes, no further adjustment actions required. Proceed with step 8.
If no, obtain the best possible focus in the center of the projected image using the motorized focus control and then turn the three
Scheimpflug adjustment nuts, reference 1, 2 an d 3 image 5-34, equally in or out until the center o f the projected image is sharp.
Note: the same turning direction as in step 5 is applicable.
1
2
3
F
Image 5-34
8. Check if it is poss ible to focus the center of the projected image using the m otorized focus control (Local Keypad) for WIDE and
for TELE.
80
R5905963 PROMETHEUS SERIES 09/03/2015
Page 85
5. Lenses & lens holder
If yes, the Back Focal Length is correctly adjusted.
If no, repeat with step 4.
9. Is the projected image in the corners as sharp as in the middle?
If yes, proceed with the procedure "Fixation of the Le ns Holder front plate", page 86.
If no, Scheimpflug adjustment is required. See procedure "Scheimpflug adjustm ent", page 82, prior to fixate the Lens Holder
front plate. CAUTION: Skip the action, in the Scheimpflug adjustment procedure, to turn the three Scheimpflug adjustment nuts
until the front of the nut is equally aligned with the front of the threaded rod!
R5905963 PROMETHEUS SERIES 09/03/2015
81
Page 86
5. Lenses & lens holder
5.7Scheimpflug adjustment
What has to be done ?
The lens holder has to be adjusted so that the “sharp focus plane” of the projected image falls together with the plane of the screen
(Fp1→Fp2). This is achieved by changing the distance between the DMD plane and the lens plane (Lp1→Lp2). The closer the lens
plane comes to the DMD plane the further the sharp focus plane will be. It can sometimes happen that you won’t be able to get a
complete focused image on the screen due to a tilt (or swing) of the lens plane with respect to the DMD plane. This is also known
as Sheimpflug’s law. To solve this the lens plane must be placed parallel with the DMD plane. This can be achieved by turning the
lens holder to remove the tilt (or swing) between lens plane and DM D plane (Lp3→Lp4).
Lp1
Lp2
DMD
Image 5-35
Scheimpflug principle
Scheimpflug principle
The "plane of sharp focus" can be changed so that any plane can be brought into sharp focus. When the DMD plane
and lens plane are parallel, the plane of sharp focus will also be par allel to these two planes. If, however, the lens
plane is tilted with respect to the D MD plane, the plane of sharp focus will also be tilted according to geom etrical and
optical properties. The DMD plane, the principal lens plane and the sharp focus plane will intersect in a line below the
projector for downward lens tilt.
Scheimpflug adjustment points
A
a
B
1
Fp1
SCREEN
Fp2
DMD
Lp3
Lp4
(Scheimpflug)
Fp4
Fp3
SCREEN
b
2
Image 5-36
Scheimpflug adjustments
4
C
d
D
3
c
Indication on drawingFunction
4Locking nut
1, 2 and 3
Scheimpflug adjustment nuts
A, B, C and DSet screws
a, b, c and dlock nuts
1, 2 and 3 are adjustment points.
4 is a locking point and NOT us ed during Scheimpflug adjustment.
82
R5905963 PROMETHEUS SERIES 09/03/2015
Page 87
5. Lenses & lens holder
Necessary tools
•Allenkey3mm
•Nut driver 13 mm
•Nut driver 10 mm
How to adjust
1. P roject a green focus pattern. For a 4K projector, use the 4K test pattern. Otherwise, use the 2K test pa ttern.
Image 5-37
2. L oosen the lock nuts (a, b, c and d). See image 5-36.
3. L oosen the 4 set screws (A, B, C and D) by 1 cm. See image 5-36.
4. F ully loosen lock nut 4 . See im age 5-36.
5. O ptimize the focus of the projected image as follows:
a) Turn the Scheimpflug adjustment nuts 1, 2 and 3 until the front of the nut is equally aligned with the front of the threaded rod.
b) Adjust the focus in the center of the screen (F) using the motorized focus control.
1
Image 5-38
Center focusing
6. S harpen bottom left corner of the screen by adjusting nu t 1.
F
2
3
R5905963 PROMETHEUS SERIES 09/03/2015
83
Page 88
5. Lenses & lens holder
Image 5-39
Left bottom focusing
7. S harpen bottom right corner of the screen by adjusting nut 2.
F
1
Image 5-40
Right bottom focusing
8. S harpen top right corner of the screen by adjusting nut 3
F
2
84
R5905963 PROMETHEUS SERIES 09/03/2015
Page 89
5. Lenses & lens holder
F
3
Image 5-41
Corner focusing
9. Repeat from step 6 until the projected focus pattern is as sharp as possible in the center, left, right, top and bottom of the screen.
10.Continue with the Fixation of the lens holder front plate procedure.
R5905963 PROMETHEUS SERIES 09/03/2015
85
Page 90
5. Lenses & lens holder
5.8Fixation of the Lens Holder front plate
When fixing the Lens Holder front plate
After performing the procedure for S cheimp flug adjustment or Back Focal Length adjustment the Lens Holder front plate must be
secured in such a way that it doesn’t disturb the result of the adjustment.
Necessary tools
•10mm nut driver.
•3mm Allen wrench.
•13mm nut driver.
How to fix the Lens Holder front plate
Start the fixation as follows (steps mu st be followed strictly) :
1. P roject t he framing test pattern for FLAT & SCOPE.
2. Z oom the projected image until the edges of the projected test pattern matches with the edges of the projection sc
FLAT
SCOPE
reen.
Image 5-42
3. Turn in the three set screws indicated with reference 11 image 5-43 without disturbing the projected image. Tighten lightly . Do
not turn in the set screw at the lowe r left of the Lens Holder!
Note: Ensure that the edges of the projected test pattern r emain in place on the screen. Any movement of the image will affect
the Scheimpflug adjustment.
4. F asten the lock nut (reference 21 image 5-43) of the three set screws. Use a 10mm nut dr iver. Ensure the image doesn’t move.
11
1121
Image 5-43
5. G ently turn (by hand) the Scheimpflug adjustment nut at the lower left of the Lens Holder (reference 4 image 5-44) against the
Lens Holder front plate without disturbing the projected im age.
6. Turn in the set screw at the lower left of the Lens Holder ( reference 14 image 5-44) without disturbing the projected image. Use
a 3mm Allen wrench.
Note: Ensure that the edges of the proje
the Scheimpflug adjustment.
Tip:Fasten the set screw and the Scheimpflug nut alternately, without disturbing the projected image, until the Scheimpflug
nut and set screw are completely tightened.
86
cted test pattern remain in place on the screen. Any movem ent of the image will affect
R5905963 PROMETHEUS SERIES 09/03/2015
Page 91
24
5. Lenses & lens holder
4
Image 5-44
7. F asten the lock nut at the lower left of the Le ns Holder. Use a 10mm nut driver.
14
R5905963 PROMETHEUS SERIES 09/03/2015
87
Page 92
5. Lenses & lens holder
88R5905963 PROMETHEUS SERIES 09/03/2015
Page 93
6. INPUT & COMMUNICATION
Overview
•Introduction
•Local keypad of the Prometheus
•Integrated Cinema Processor (ICP)
•HD-SDI Input Module (optional)
•Quad 3G-SDI Input Module (optional)
•Integrated Media Block/Server (optional)
•Cinema Controller of the Prometheus
6. Input & communication
R5905963 PROMETHEUS SERIES 09/03/2015
89
Page 94
6. Input & communication
6.1Introduction
General
The Input & Communication side of the Prometheus consists of a Local Keypad and a card cage with four slots. The rear side of
the projector is equipped with a tail light which reflects the status of the projector.
Depending on the projector configuration the projector card cage is equipped with an ICP or ICMP. See illustration below. In cas e
an ICP is installed then an IMB, IMS , or HDSDI input module can be optionally inserted into the slot below the IC P. Note that all
information about the ICMP is gathered into one separated chapter called ICMP.
Image 6-1
1Fan Control Board (FCB).
2Integrated Cinema Processor (ICP).
3Optional slot for either IMB, IMS or HD-SDI input module.
4Barco Cinema Controller.
5Barco ICMP (inserted in ICP slot and optional slot).
CAUTION: A unit may only be removed from the card cage by quali fied service personnel. Removing one of
the boards (except for the Cinema Controller) will result in an authorization request upon starting.
1
1
2
5
3
4
4
90R5905963 PROMETHEUS SERIES 09/03/2015
Page 95
6.2Local keypad of the Prometheus
Identification of the keys
6. Input & communication
1
Image 6-2
Local keypad
1Marker area for macr o name
2Numeric keyboard
3Standby key
4Dowser open/close switch
5
Test pattern toggle switch
6Lens shift up/down, left/right
7
Lens focus
8Lens zoom
2
3
4
5
1
2
3
6
4
5
6
7
8
Numeric keys
All the numeric keys (2) of the local keypad have a blue backlight during normal operation. When the au thorization process is
activated with the secu rity key, the backlight color of the numeric keys 1 to 6 changes to orange. Each key can be linked to a mac ro
which allows you to setup the projector to your requirements with one push of a button. Note that each numeric key has a mark er
area (1) where you can write down the name of the macro.
Standby key
Standby k ey (3) switches O N or OFF the lamp and lamp electronics. The lamp cooling fans remain active for a bout 5 minutes. The
speed of the other fans is reduced. The backlight color of the standby key remains red in standby mode and changes to green in
operation mode.
Dowser key
The dowser key (4) opens or closes the dowser. The backlight color of the dowser key is green when the dowser is open and red
when the dowser is closed.
Test pattern key
The test pattern k ey (5) gives you direct access to the internal test patterns of the projector.
Shift keys
The shift keys (6) allow you to shift the lens up/down or left/right.
Focus keys
The focus keys (7) allow you t
o focus the projected image on the screen.
Zoom keys
The zoom keys (8) allow you to zoom in or out the projected image on the screen.
R5905963 PROMETHEUS SERIES 09/03/2015
91
Page 96
6. Input & communication
6.3Integrated Cinema Processor (ICP)
In case the projector is equipped with a B arco ICMP no ICP b oard is inserted. All ICP functionality is integrated
in the Barco ICMP.
.
LEDs and ports on the Integrated Cinema Processor
12
ICP
POWER
Image 6-3
1ICP is powered.
2ICP software state, normal operation is green blinking.
3ICP operating system state, normally full green .
4ICPFMTconfiguration state, normally full green.
5ICPMAINconfiguration state, normally full green.
6CINEMA port selected. When on, LED 7 will be out.
7ALTERNATIVE port selection. When on, LED 6 will be out. (note that this function is disabled. Led never lights up)
8USB, for future use.
9USB, for future use.
3
SW
STATOSSTAT
4
5
FMT
STAT
6789
ICP
STATCINEMA
CONT
USB
ALT
OUT
LED diagnostic
State description
Software state (LED reference 2)flashing green
Operating System s tate (LED reference 3)
FMT FPGA stat e (LED reference 4)
ICP FPGA state (L ED reference 5)
Normal operationError state
red or orange
green
green
off, red or yellow
red : unable to configure the FPGA
yellow : FPGA is loaded with the Boot
green
application
red : unable to configure the FPGA
yellow : FPGA is loaded with the Boot
application
USB
IN
ICP functions:
•Stores all projector files. When bo
•Stores and generates test patterns.
•Scaling to native resolution, re-sizing, masking, line-insertion de-interlacing, subtitle overlay, color s pace conversion,
de-gamma, color correction
•Source Selection between alternative content and cinema content.
•Stores a C e rtificate and Private Key needed for Playback validation
•Contains a real time clock, which must be synchronized with the GMT/UTC time s tored in the link decryptor module or Integrated
Media Block (see Com municator software)
•Handles unpacking of special video formats
The ICP board spare part kit is not default programmed for a Prometheus projector. When using this board in
a Prometheus projector the soft
When installing a new ICP board in a Prometheus p rojector the Spatial Color Calibration file must be reloaded
and activated. See ch apter .
ard is replaced; clone package must be reloaded.
ware m ust be re-installed after installation of the board.
CAUTION: Make sure not to short circuit the battery on the board. That will destroy the board completely !
92R5905963 PROMETHEUS SERIES 09/03/2015
Page 97
6.4HD-SDI Input Module (optional)
Depending on the projector configuration the projector card cage is either equipped with an ICP or ICMP. In
case an ICP is installed then an IMB, IMS, or HDSDI input module can be optionally inserted into the slot below
the ICP. This is not the case if the ICMP is installed. For more information about the ICMP see chapter called
ICMP.
Location of the source input ports
6. Input & communication
12
SMPTE 292/424 IN
AB
SEL
SEL
Image 6-4
1SMPTE 292/424 input, port A (maximum cable length of 30 m allowed)
2SMPTE 292/424 input, port B (maximum cable length of 30 m allowed)
SMPTE
Society of Motion Picture and Television E ngineers - A global organization, based in the United States, that sets standards for b aseband visual communications. T his includes film as well as video standards.
HD-SDI settings
Source: 2K
General settingsAdvanced settings
PortP o rt ty peModeScan typeColor
AorB
HDSDI Single link 4:2:2 1 0
bits/color
Progressive
Progressive - field bit
normal
Progressive - field bit
inverted
Progressive SF - 2nd
field dominant
Progressive SF - 1st
field dominant
3GSDI link
ProgressiveYCbCr
bits/color
space
YCbCrHDSDI-Single linkSingle
SYNC OK
SYNC OK
Pixel mappingCalibration
3G-level A-Single link4:2:2 12
Single
3G-level B-Dual link
4:4:4 10
Progressive
RGB
3G-level A-Single link
bits/color
3G-level B-Dual link
4:4:4 12
Progressive
XYZ/RGB
3G-level A-Single link
bits/color
3G-level B-Dual link
R5905963 PROMETHEUS SERIES 09/03/201593
Page 98
6. Input & communication
PortPort typeMode
A+B
HDSDI D uallink
AB
General settings
Scan typeColor
4:4:4 10
bits/color
4:4:4 12
bits/color
Progressive
Progressive - field bit
normal
Progressive - field bit
inverted
Progressive SF - 2nd
field dominant
Progressive SF - 1st
field dominant
Progressive
Progressive - field bit
normal
Progressive - field bit
inverted
Progressive SF- 2nd
field dominant
Progressive SF - 1st
field dominant
Source: 2K
space
RGB
XYZ/RGB
Advanced settings
Pixel mapping
HDSDI-Dual linkSingle
Calibration
General settings
PortPort typeMode
AorB
A+B
3GSDI link - 3D
HDSDI 3D
3GSDI 3D
4:2:2 10
bits/color
4:2:2 10
bits/color
4:2:2 12
bits/color
4:4:4 10
bits/color
Source: 2K-3D
Scan typeColor
Progressive
field dominant
Progressive SF - 2nd
field dominant
Progressive
field dominant
Progressive SF - 2nd
field dominant
Progressive
ProgressiveRGB
space
YCbCr3G - Level B - Dual
YCbCr3G - Level B - Dual
YCbCr3G - Level B - Dual
YCbCrHDSDI - Interleaved
YCbCrHDSDI - Interleaved
YCbCrHDSDI - Interleaved
YCbCr
Advanced settings
Pixel mapping
stream
stream
stream
Interleaved
3G - Level B Interleaved
Interleaved
Calibration
Single
Dual (separate
left / right eye)
SingleProgressive SF - 1st
Dual (separate
left / right eye)
Single
Dual (separate
left / right eye)
Single
Dual (separate
left / right eye)
SingleProgressive SF - 1st
Dual (separate
left / right eye)
Single
Dual (separate
left / right eye)
Single3G - Level A -
Dual (separate
left / right eye)
Single
Dual (separate
left / right eye)
Single3G - Level A -
Dual (separate
left / right eye)
94
R5905963 PROMETHEUS SERIES 09/03/2015
Page 99
General settings
PortPort typeMode
4:4:4 12
bits/color
General settings
PortPort typeMode
AorB
A+B
3GSDI link - H F R
HDSDI HFR
3GSDI HFR
4:2:2 10
bits/color
4:2:2 10
bits/color
4:2:2 12
bits/color
4:4:4 10
bits/color
4:4:4 12
bits/color
Source: 2K-3D
Scan typeColor
ProgressiveXYR/RGB
Source: 2K-HFR
Scan typeColor
Progressive
Progressive
Progressive SF - 1st
field dominant
Progressive SF - 2nd
field dominant
Progressive
Progressive
Progressive
space
space
YCbCr
YCbCrHDSDI - InterleavedSingle
YCbCr
RGB
XYZ/RGB
6. Input & communication
Advanced settings
Pixel mapping
Interleaved
Interleaved
3G - Level B Interleaved
Advanced settings
Pixel mapping
3G - Level B - Dual
stream
3G - Level B - Single
link
3G - Level A Interleaved
3G - Level B Interleaved
3G - Level A Interleaved
3G - Level B Interleaved
3G - Level A Interleaved
3G - Level B Interleaved
Calibration
Single3G - Level B -
Dual (separate
left / right eye)
Single3G - Level A -
Dual (separate
left / right eye)
Single
Dual (separate
left / right eye)
Calibration
Single
Single
Single
Single
Source: 3D-HFR
General settings
PortPort typeMode
A+B
R5905963 PROMETHEUS SERIES 09/03/201595
3GSDI 3D HFR
4:2:2 10
bits/color
Scan typeColor
Progressive
field dominant
Progressive SF- 2nd
field dominant
space
YCbCr3G - Level A -
YCbCr3G - Level A -
YCbCr3G - Level A -
Advanced settings
Pixel mapping
Interleaved
Interleaved
Interleaved
Calibration
Single
Dual (separate
left / right eye)
SingleProgressive SF - 1st
Dual (separate
left / right eye)
Single
Dual (separate
left / right eye)
Page 100
6. Input & communication
6.5Quad 3G-SDI Input Module (optional)
Location and source input ports
QUAD 3G/SDI INPUT
ABCD
SEL
SEL
SEL
SEL
SYNC OK
Image 6-5
SYNC OK
SYNC OK
SYNC OK
The following input combinations are possible : A, B, A+B, A+B+C+D
When using all 4 four inputs to create the image connect the quadrants of the image to the inputs as indicated on the drawing.
AB
Image 6-6
Quadrant connection
To c o n figure the input, consult the Comm unicator manua l
DC
96R5905963 PROMETHEUS SERIES 09/03/2015