MGD 521 M - MKII User's Guide3
MGD 521 M - MKII User's Guide4
SAFETY INSTRUCTIONS
Regulations
This apparatus conforms to: IEC601-1,
UL2601-1, cUL2601-1, EN 60601-1
This apparatus is classified as Type B
without Applied Part.
Usage in Hazardous locations
Class I equipment
Equipment not suitable for use in the
presence of a flammable anaesthetic
mixture with air or with oxygen or nitrous
oxyde.
FCC notice
This equipment has been tested and found
to comply with the limits of a class A digital
device, pursuant to Part 15 of the FCC rules.
These limits are designed to provide
reasonable protection against harmful
interference when the equipment is operated
in a commercial environment. This equipment
generates, uses and can radiate radio
frequency energy and, if not installed and
used in accordance with the instruction
manual, may cause harmful interference to
radio communications. Operation of this
equipment in a residential area is likely to
cause harmful interference in which case the
user will be required to correct the interference
at his own expense.
!
Power connection
Power cord: Utilise a UL-listed detachable
power cord, 3-wire, type SJ or equivalent, 18
AWG min., rated 300 V min., provided with a
hospital-grade type plug 5-15P configuration
for 120V application, or 6-15P for 240V
application.
Warning: This apparatus must be earthed!
Power requirements: connect the apparatus
Read the safety and operating instructions
before operating the apparatus.
Retain safety and operating instructions for
future reference.
Adhere to all warnings on the apparatus
and in the operating instructions manual.
Follow all instructions for operation and
use.
to an AC voltage as indicated at its back.
Using a lower voltage, the apparatus will not
be able to operate. Using a higher voltage
may damage the apparatus.
If you are not sure of the type of power
supplied, consult the power company.
Do not overload wall outlets and extension
cords as this may result in fire or electric
shock.
Mains lead protection (U.S.: Power cord):
Supply cords should be routed so that they
are not likely to be walked upon or pinched by
items placed upon or against them, paying
particular attention to cords at plugs and
receptacles.
Water and moisture
Never expose the apparatus to rain or
moisture.
Never use the apparatus near water - e.g.
near a bathtub, washbasin, swimming pool,
kitchen sink, laundry tub or in a wet basement.
Ventilation
Do not cover or block the ventilation openings
in the cover of the set. When installing the
apparatus in a cupboard or another closed
location, heed the necessary space between
the set and the sides of the cupboard.
Installation
Place the apparatus on a flat, solid and
stable surface that can bear the weight of at
least 3 monitors. If you use an unstable cart
or stand, the set may fall, causing serious
injury to a child or adult, and seriousdamage
to the equipment.
More warnings in the Installation chapter.
The BARCO MGD 521 M and MGD 521 MKII displays are ultra-high
resolution, grayscale portrait displays. Their outstanding visual
performance, combining a 5 MegaPixel resolution with a very high
brightness, makes them ideal for diagnostic imaging and many other
medical and scientific applications.
The displays are compatible with any AC power system worldwide
and automatically synchronise to a wide range of sync frequencies.
their high-speed video amplifiers support pixel clocks up to 500 MHz
(MGD 521 M: 550 MHz).
The memory system
The internal memory system can contain the adjustments for 16
different scanning formats, the so-called scanning modes. Each
scanning format is characterized by its sync signals. The displays
internal micro controller continuously samples the connected sync
signals and compares them to the scanning modes already stored in
the memory. If the connected signal has already been stored, the
micro controller adapts the image to the corresponding adjustment
values in the memory, and further adjustments are unnecessary.
Image conformity and consistency
Image conformity and consistency are the keywords. In our factory,
the MGD 521 displays are perfectly adjusted and calibrated before
they are shipped to the customer. Internal circuits, like the TrueGrey®
and Automatic White Stability (AWS) systems, ensure display
consistency over time.
Conformity with the original image quality is guaranteed by the
automatic calibration, which can be done by means of an optical
sensor, connected to the Sensor connector on the display. The
sensor is not supplied with the display.
Calibration and adjustments
The conformity calibration, as well as the complete adjustment of the
display, can be performed by means of the remote, user-friendly
MediCal® software package. MediCal is especially developed to
Introduction9
adjust and check BARCOs medical displays.
A lot of adjustments can also be done on the monitor itself, by means
of an extensive on-screen menu system, accessible from the rear
panel controls.
Power saving system
The MGD 521 displays are equipped with a power saving system.
When left idle for a certain time, the computer, connected to the
display, will power down the display in several steps. The power
saving system can be switched on or off during the installation or
adjustment of the display.
This system requires a computer imaging board that supports power
saving management.
1.2 Versions and options
MGD 521 MMGD 521 MKII
P45 phosphors ................ x .................................. x
50 Ohm input .................. x .................................. x
75 Ohm input .................. x .................................. x
Notes:
- The P45 phosphors produce rather bluish images, whereas the
P104 phosphors produce more yellowish images.
- A video input terminated to 50 Ohm requires an imaging board
with an impedance of 50 Ohm. A video input terminated to 75 Ohm
requires an imaging board with an impedance of 75 Ohm.
- The type of CRT phosphors and the video input termination are
indicated on the label at the rear of the display.
Important:
It is absolutely necessary that the impedances of imaging board and
display are the same. If not, the image quality will be inferior.
The MediCal software and the X-Rite DTP92 sensor are not delivered
with the display.
MediCal can be ordered separately.
Introduction10
1.3 About the manuals
This guide is meant for people who want to install and use the MGD
521 displays, as well as people who need to install and adjust the
displays. Chapter 4, Adjustments, is meant for this second category
only, because it describes actions and procedures that require a
technical skill to be performed properly.
The use of the software MediCal is described in the MediCal Users
Manual.
Installation11
2. INSTALLATION
2.1 Precautions
Keep your original packaging. It is designed for this display and is
the ideal protection during transport.
Do not lift the display all by yourself to avoid injury.
Avoid reflections in the picture tube to reduce eye strain.
Place the display on a strong and stable table or desk if used as
desktop display.
Keep the display away from heat sources and provide enough
ventilation in case it is built in a rack or console.
Keep the display away from strong sources of magnetic fields.
Make sure the display and computer are both switched off before
connecting the signals.
2.2 The package contents
The display
The accessory box (in which you found this manual)
Notes:
The display can be part of a complete MeDis
of the display itself, an imaging board and software. In that case,
the package contains a lot more items. The contents of the
package is then described in the manual of the complete system.
The ambient light shield inside the accessory box should always
be used during conformity calibration with the X-Rite DTP92
optical sensor.
®
system, consisting
Installation12