Barco LCD 5521 V4 Installation Manual

Page 1
Installation manual
LCD 5521 V4
OVD/KVD/IVD/HVD
R591734
Page 2
R591734, Current Version
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________________________
ii
Page 3
Trademarks
Brand and product names mentioned in this manual may be trademarks, registered trademarks or copyrights of their respective holders. All brand and product names mentioned in this manual serve as comments or examples and are not to be understood as advertising for the products or their manufacturers.
Copyright © 2017 by Barco
Die Weitergabe sowie die Vervielfältigung aller Unterlagen, die von uns überlassen werden, deren Verwertung und Mitteilung ihres Inhaltes an Dritte ist nicht gestattet, soweit dies nicht ausdrücklich zugestanden ist. Urheberrechte, insbesondere auch solche an Software, werden nur insoweit übertragen, als es für die Erreichung des speziellen Vertragszwecks erforderlich ist. Zuwiderhandlungen können zu Schadensersatz verpflichten. Alle Rechte aus der Erteilung eines Patents oder der Eintragung eines Gebrauchsmusters verbleiben bei uns.
Copyright © 2017 by Barco
All rights reserved. No part of this document may be copied, reproduced or translated. It shall not otherwise be recorded, transmitted or stored in a retrieval system without the prior written consent of BARCO.
Guarantee and Compensation
Barco provides a guarantee relating to perfect manufacturing as part of the legally stipulated terms of guarantee. On receipt, the purchaser must immediately inspect all delivered goods for damage incurred during transport, as well as for material and manufacturing faults. BARCO must be informed immediately in writing of any com­plaints.
The period of guarantee begins on the date of transfer of risks, in the case of special systems and software on the date of commissioning, at the latest 30 days after the transfer of risks. In the event of justified notice of complaint, BARCO can repair the fault or provide a replacement at its own discretion within an appropriate peri­od. If this measure proves to be impossible or unsuccessful, the purchaser can demand a reduction in the pur­chase price or cancellation of the contract (redhibition). All other claims, in particular those relating to compensa­tion for direct or indirect damage, and also damage attributed to the operation of software as well as to other services provided by BARCO, being a component of the system or independent services, will be deemed invalid provided the damage is not proven to be attributed to the absence of properties guaranteed in writing or due to the intent or gross negligence on the part of BARCO.
If the purchaser or a third party carries out modifications or repairs on good delivered by BARCO, or if the goods are handled incorrectly, in particular if the systems are commissioned or operated incorrectly or if, after the transfer of risks, the goods are subject to influences not agreed upon in the contract, all guarantee claims of the purchaser will be rendered invalid. Not included in the guarantee coverage are system failures which are at­tributed to programs or special electronic circuitry provided by the purchaser, e. g. interfaces. Normal wear as well as normal maintenance are not subject to the guarantee provided by BARCO either.
The environmental conditions as well as the servicing and maintenance regulations specified in this manual must be complied with by the customer.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
____________________________________________________________________________
iii
Page 4
Revision sheet
To:
BARCO Control Rooms GmbH
Greschbachstr. 5a, D-76229 Karlsruhe Phone: +49-721-6201-0, Fax: +49-721-6201-298 E-mail: docu.de.bcd@barco.com, Web: www.barcocontrolrooms.com
From:
Date:
Please correct the following points in this documentation (R591734):
page
wrong
correct
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
____________________________________________________________________________
iv
Page 5
Contents
1 Preliminary Remarks ............................................................................................................................ 7
1.1 Styles and symbols ......................................................................................................................................... 8
1.2 Safety information .......................................................................................................................................... 9
1.2.1 Safety on installation ........................................................................................................................... 10
1.2.2 Safety on servicing .............................................................................................................................. 13
1.2.3 Safety instruction on opening systems built into a structure ............................................................ 15
1.2.4 Safety on shipping ............................................................................................................................... 16
1.2.5 Precautions .......................................................................................................................................... 16
1.2.6 Unpacking of devices ........................................................................................................................... 17
1.2.7 Modification of devices ....................................................................................................................... 17
1.2.8 Cleaning ............................................................................................................................................... 17
1.2.9 Moving the product ............................................................................................................................. 17
1.2.10 Disposal or handing over to a new owner ....................................................................................... 17
1.2.1 Environmental information: disposal information ............................................................................. 18
1.2.2 Exemptions........................................................................................................................................... 18
2 Mechanical setup ................................................................................................................................ 19
2.1 Tools needed for installation ....................................................................................................................... 19
3 Scope of delivery ................................................................................................................................ 20
3.1 Front access mount ...................................................................................................................................... 20
3.2 Display .......................................................................................................................................................... 20
3.3 Pedestal ........................................................................................................................................................ 20
3.4 Wall mount ................................................................................................................................................... 20
4 Adjustment of the mechanics for the display ................................................................................... 21
4.1 Pedestal ........................................................................................................................................................ 21
4.2 Front access mount module ......................................................................................................................... 22
5 Mechanical setup of display wall with pedestals .............................................................................. 25
5.1 Overview ....................................................................................................................................................... 25
5.2 Preparation ................................................................................................................................................... 26
5.2.1 Wall fixation ......................................................................................................................................... 26
5.2.2 Mounting the wall fixation brackets for video walls with (kind of standard) supports ................... 28
5.3 Connection concept ...................................................................................................................................... 32
5.4 Installation of the pedestal .......................................................................................................................... 33
5.4.1 Preparation of front access mount module (non-top row) ............................................................... 48
5.4.2 Preparation of front access mount module, top row ......................................................................... 49
5.4.3 Installation of the front access module, first row .............................................................................. 50
5.4.4 Installation of the second row ............................................................................................................ 54
5.5 Floor fixation of the display wall ................................................................................................................. 60
5.6 Finalizing the structure ................................................................................................................................. 61
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________________________
v
Page 6
6 Mechanical setup of display walls with wall mount solutions ......................................................... 62
7 Cabling ................................................................................................................................................. 75
7.1 Cabling .......................................................................................................................................................... 75
7.2 Grounding ..................................................................................................................................................... 78
8 Installation of the displays ................................................................................................................. 79
8.1 Safety instruction on opening systems ....................................................................................................... 87
9 Distance to the wall ............................................................................................................................ 88
10 Addresses .......................................................................................................................................... 90
10.1 Contact ........................................................................................................................................................ 91
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
____________________________________________________________________________
vi
Page 7
1. Preliminary Remarks
1 Preliminary Remarks
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
____________________________________________________________________________
7
Page 8
1. Preliminary Remarks
1.1 Styles and symbols
The typographic styles and the symbols used in this document have the following meaning:
Bold Labels, menus and buttons are printed in Bold font.
Condensed Links to both other chapters of this manual and to sites in the Internet are printed
condensed. In the on-line version of this manual all hyperlinks appear teal.
Courier
Names of files and parts from programs are printed in the
Courier
font.
Courier bold
Inputs you are supposed to do from the keyboard are printed in
Courier bold
font.
If you do not heed instructions indicated by this symbol there is a risk of damage to the equipment!
Le non-respect des instructions symbolisées par ce pictogramme entraînera un risque de dommage de l'équipement ! �
If you do not heed instructions indicated by this symbol there is a risk of electrical shock and danger to personal health!
Le non-respect des instructions symbolisées par ce pictogramme entraînera un risque de décharge électrique et sera source de danger pour la santé du personnel ! �
If you do not heed instructions indicated by this symbol there is a risk of damage to parts, which are sensitive towared electrostatic charge!
Le non-respect des instructions symbolisées par ce pictogramme entraînera un risque de dommage de pièces sensibles à la charge électrostatique ! �
If you do not heed instructions indicated by this symbol there is a risk to get harmed by sharp objects!
Le non-respect des instructions symbolisées par ce pictogramme entraînera un risque de blessure dû à des objets tranchants !
If you do not heed instructions indicated by this symbol there is a risk that parts may explode!
Le non-respect des instructions symbolisées par ce pictogramme entraînera un risque d'explosion de pièces ! �
If you do not heed instructions indicated by this symbol there is a risk that hot parts impact persons or objects!
Le non-respect des instructions symbolisées par ce pictogramme entraînera un risque de contact de personnes ou d'objets avec des pièces chaudes !
The sheet icon indicates additional notes.
Cette icône représentant une feuille indique des remarques supplémentaires.
Next to this icon you find further information.
Cette icône est suivie d'informations plus détaillées. �
This hand marks tips. Cette icône attire l'attention sur des conseils.
Next to this icon you find important notes.
Cette icône est suivie de remarques importantes.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
____________________________________________________________________________
8
Page 9
1. Preliminary Remarks
1.2 Safety information
This section describes safety precautions which must be observed when installing a product from Barco.
Safety standards
The displays are built in accordance with the requirements of the international safety standards EN 60950-1
and
IEC 60950-1. The displays conforms to UL std. UL 60950-1 and is certified to CSA std. C22.2 No. 60950-1 and Chine Compulsory Certifcation CCC. All these safety standards are the information technology equipment standards, including electrical business equipment.
These safety standards impose important requirements on the use of safety critical components, materials and isolation, in order to protect the user or operator against the risk of electric shock and energy hazard, and having access to live parts.
Safety standards also impose requirements to the internal and external temperature variations, radiation levels, mechanical stability and strength, enclosure construction and protection against risk of fire.
Simulated single fault condition testing ensures the safety of the equipment to the user even when the equip­ment's normal operation fails.
Electromagnetic Interference
The displays complies with the following EMC standards: Electromagnetic compatibility -
emission:
EN 55022 (2010) EN 61000-3-2 (2006) + A1 (2009) + A2 (2009) EN 61000-3-3 (2008)
Electromagnetic compatibility ­immunity:
EN 55024 (2010)
Make sure to use cables with shielding of type S-FTP or S-STP when connecting the display to the network!
Assurez vous d'utiliser des câbles avec un blindage de type S-FTP ou S-STP lors de la connexion de l’écran au réseau!
EN55022/CISPR22 Class B ITE (Information Technology Equipment)
The devices are products of class B ITE. ITE means Information Technology Equipment. ITE is subdivided into two categories denoted class B ITE (products intended primarily for use in domestic environment) and class A ITE (all other ITE which satisfies the class A ITE limits but not the class B ITE limits).
FCC Compliance statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accord­ance with the instruction manual, may cause harmful interference to radio communications. However there is no guarantee that interferences will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception (which can be determined by turning the equipment on and off), the user is encouraged to try to correct the interference by using one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
____________________________________________________________________________
9
Page 10
1. Preliminary Remarks
Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user's (or your) authority to operate the equipment. Only peripherals (digital input/output devices, terminals, printers, etc.) certified to comply with the Class B limits may be attached to this display. Operation with non-certified peripherals is likely to result in interference to radio and TV reception. Only shielded signal cables may be used with this System.
Attention: Des changements ou modifications non expressément approuvés par la partie res­ponsable de la conformité pourraient annuler l'autorité de l'utilisateur ou la votre pour utiliser l'équipement. Seuls les périphériques (entrée numérique / périphériques de sortie, terminaux, imprimantes, etc) certifiés comme étant con­formes aux limites de la classe B peuvent être connectés à cet écran. L'utilisation de périphé­riques non conformes peut provoquer des inter­férences dans la réception radio et télévision. Seuls des câbles blindés peuvent être utilisés avec ce système
The regulations are applied only to the products with the ID LABEL indicating specific requirements.
Les règlements sont appliqués que pour les pro­duits avec l'étiquette d'identification indiquant les besoins spécifiques.
General safety instructions
All the safety and operating instructions should be read before using this unit.
The operating instructions manual should be retained for future reference.
All warnings on the device and in the documentation manuals should be adhered to.
All instructions for operating and use of this equipment must be followed precisely.
All local installation codes should be adhered to.
Installation and preliminary adjustments should be performed by qualified Barco personnel or authorized Barco service dealers.
Installation et réglages préliminaires devraient être effectués par du personnel qualifié de Barco ou les revendeurs autorisés par Barco
1.2.1 Safety on installation
Check the power rating on your out­let before connecting the devices to the AC inlet. Contact your facilities manager or a qualified electrician if you are not sure what type of power is supplied to your building.
Vérifiez la puissance sur la prise avant de bran­cher les appareils sur la prise secteur. Contactez votre gestionnaire des installations ou un électri­cien qualifié si vous n'êtes pas sûr du type d'ali­mentation fourni dans votre bâtiment
The devices are designed to operate with single-phase power systems having a grounded neutral conduc­tor. To reduce the risk of electrical shock, do not plug into any other type of power system.
Les dispositifs sont conçus pour fonctionner avec les systèmes d'alimentation monophasés avec conducteur neutre à la terre. Pour réduire le risque de choc électrique, ne branchez pas sur un autre type de système d'alimentation.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
__________________________________________________________________________
10
Page 11
1. Preliminary Remarks
1.2.1.1 Connecting the device with the AC inlet
When connecting the device with the AC inlet, make sure that the power cords you use follow the specifications mentioned below:
Mains lead (AC Power cord) with CEE 7 plug:
The wires of the mains lead are colored in accordance with the following code:
yellow + green
Earth (Ground)
blue
Neutral
brown
Line (Live)
Power cord with NEMA 5-15 plug:
The wires of the power cord are colored in accordance with the following code.
Green or Green/Yellow:
Earth (Ground)
White or Blue:
Neutral
Black or Brown:
Line ( Live)
The cord set must be UL-approved and CSA-certified.
The minimum specification for the flexible cord is No. 18 AWG Type SVT or SJT, 3-conductor.
The cord set must have a rated current capacity of at least 10A.
The attachment plug must be an Earth-grounding type with a NEMA 5-15P (10 A, 125 V) configuration.
Power cord with GB 2099 plug:
The wires of the power cord are colored in accordance with the following code.
yellow + green
Earth (Ground)
blue
Neutral
brown
Line ( Live)
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
__________________________________________________________________________
11
Page 12
1. Preliminary Remarks
Do not allow anything to rest on the power cord. Do not locate this product where persons will walk on the cord.
To disconnect the cord, pull it out by the plug. Never pull the cord itself.
Do not touch the power cord with wet hands. If the cord pin is wet or covered with dust, dry the power plug
completely or wipe dust off.
Fix the power cable completely.
Do not unplug the power cord while the product is in use.
As long as this unit is connected to the AC wall outlet, it is not disconnected from the AC power source even
if the unit is turned off.
If an extension cord is used with this product, make sure that the total of the ampere ratings on the products plugged into the extension cord does not exceed the extension cord ampere rating. Also make sure that the total of all products plugged into the wall outlet does not exceed 15 amperes.
Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltage points or short out parts that could result in a risk of fire or electrical shock.
Never spill liquid of any kind on the product. Should any liquid or solid object fall into the cabinet, unplug the set and have it checked by qualified service personnel before resuming operations.
Lightning - For added protection for this video product during a lightning storm, or when it is left unattended and unused for long periods of time, unplug it from the wall outlet. This will prevent damage to the display due to lightning and AC power-line surges.
Do not place flammable or combustible materials near the display!
Ne placez pas de matériaux inflammables ou combustibles près de l'écran!
Transportation
Any transportation of the unopened unit in its packaging should be done by two persons.
In transportation or storage of products in original packing, NEVER stack more than the number stated on the
carton box. This warning is also indicated on the side of the card box.
For transportation or storage, observe the warnings and instructions on the side of the card box.
Nearby equipment
If air conditioning ducts or lamps, etc. are located near the installation site, the attendant dust, extreme temper­atures, humidity, and condensation may become sources of trouble. Please take sufficient steps to avoid this.
Installation places
Do not install the unit where it may be easily touched or leaned against. Avoid locations subject to high vibra­tions or severe impacts. Do not install the unit where it is exposed to humidity, oil, smoke or excessive dust. Mount the display in a well ventilated area away from sources of ignition and out of direct sun light. Never ex­pose this product to rain or excessive moisture.
If you install the product in a place where there is an abundance of fine dust, chemical substances are used, the temperature is very high or low, the humidity is very high, or the product is likely to remain turned on for a long period of time this might cause serious damage to the product's picture quality, life cycle and appearance.
Install the unit on a neat and dry place. Install the unit on a flat and stable place.
Operating the product
Take a rest from time to time to protect your vision. Take a regular break when working with the product for a long time. Keep the proper distance from the product. Your vision may be impaired if you look at the product too closely. Using headsets (earphones) for a long time or listening loudly can cause damage to your hearing.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
__________________________________________________________________________
12
Page 13
1. Preliminary Remarks
LED inside!
Class 1M laser (LEDs) radiation when open.
Do not open while operating!
LED à l'intérieur! Rayonnement Laser de classe 1M (LEDs) lorsqu'il est ouvert. Ne pas ouvrir pendant le fonctionnement!
Mechanical stress
Please be careful not to apply strong mechanical stress (shock, drop) to the LCD module. Such stress may cause break of screen glass or may be the cause for failure.
Pressure to screen surface
Please be careful not to apply strong pressure to the screen surface. Such pressure may cause scratches at the surface or may be the cause of failure.
Protection against scratch
Please be careful not to hit, press or rub the screen surface with hard material like tools. In addition, please do not put heavy or hard material on the screen surface, and do not stack displays. Polarizer at the front surface can be easily scratched.
Temperature dependence of the display
Response speed (optical response) of the LCD display is dependent on temperature. Under low temperature, response speed is slower. Also brightness and chromaticity change slightly depend on temperature.
Image retention
Displaying the same pattern for a long time may cause image sticking, vertical dark lines or other forms of image artifacts. This is a common phenomenon of all LCD displays. It disappears after some time if the pattern is changed, or the display is switched off. However, image retention is not subject of warranty. For more information contact Barco for a white paper on this topic.
Lighting conditions
Consider existing lightning and sunlight angles when creating the installation layout. Extremely bright lightning can reduce the visibility and the quality of the displayed image.
In extremely bright surroundings, adjusting screen intensity may not result in perceptibly brighter images. Keep in mind that extreme intensity settings can reduce system service life.
Barco products are designed and manufactured to meet the most stringent safety regulations. Exposing flamma­ble or combustible materials into close proximity of this device could result in the spontaneous ignition of that material, resulting in a fire. For this reason, it is absolutely necessary to leave an "exclusion zone" around all external surfaces of the display whereby no flammable or combustible materials are present. The exclusion zone must be not less than 10 cm (4"). Do not cover the display with any material while it is in operation.
Keep flammable and combustible materials away from the display at all times. Mount the display in a well venti­lated area away from sources of ignition and out of direct sun light. Never expose this product to rain or exces­sive moisture. In the event of fire, use sand, CO
2
, or dry powder fire extinguishers; never use water on an electri-
cal fire. Always have service performed on this product by authorized Barco service personnel. Always insist on genuine
Barco replacement parts. Never use non-Barco replacement parts as they may degrade the safety of this device. Use only the power cord which fulfill the specifications as listed in1.2.1.1 Connecting the device with the AC inlet. Slots
and openings in the cabinet and the sides are provided for ventilation; to ensure reliable operation of the device and to protect it from overheating, these openings must not be blocked or covered. This product should never be placed near or over a radiator or heat register. This product should not be placed in a built-in installation or en­closure unless proper ventilation is provided.
1.2.2 Safety on servicing
Do not attempt to service this device yourself, as opening or removing covers may expose you to dangerous voltage potential and risk of electric shock! Refer all display service to a qualified Barco service center.
Adjust only those controls that are covered by the operating instructions since improper adjustment of the other controls may result in damage and will often require extensive work by a qualified technician to restore the product to normal operation.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
__________________________________________________________________________
13
Page 14
1. Preliminary Remarks
Call for service in the following conditions:
When the power cord or plug is damaged or frayed.
• If liquid has been spilled into the device.
If the product has been exposed to rain or water.
If the product does not operate normally when the operating instructions are followed.
If the product has been dropped or the cabinet has been damaged;
If the product exhibits a distinct change in performance, indicating a need for service.
Replacement parts
When replacement parts are required, be sure the service technician has used original Barco replacement parts or authorized replacement parts which have the same characteristics as the Barco original part. Unauthorized substitutions may result in degraded performance and reliability, fire, electric shock or other hazards. Unauthor­ized substitutions may void warranty.
Safety check
Upon completion of any service or repairs to this unit, ask the service technician to perform safety checks to determine that the unit is in proper operating condition.
Protection
Please do not disassemble or modify the LCD module to avoid the possibility of electric shock, damage of elec­tronic components, scratch at display surface and invasion of foreign particles. In addition, such activity may result in fire accident due to burning of electronic component.
The LCD module disassembled or modi­fied by customer is out of warranty.
Le module LCD démonté ou modifié par le client n'est plus sous garantie
Please be careful in handling of display with broken glass. When the display glass breaks, please pay attention not to injure your fingers. The display surface has the plastic film attached, which prevents dispersion of glass pieces; however touching broken edge will injure your fingers.
Please do not touch the fluid flown out of broken display glass. If the fluid should stick to hand or clothes, wipe off with soap or alcohol immediately and then wash it with water.
If the fluid should get in your eyes, wash your eyes immediately with pure water for more than 15 minutes and then consult the doctor.
Si le liquide entre en contact avec vos yeux, lavez-vous immédiatement les yeux avec de l'eau pure pendant plus de 15 minutes, puis consulter le médecin.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
__________________________________________________________________________
14
Page 15
1. Preliminary Remarks
1.2.3 Safety instruction on opening systems built into a structure
When doing maintenance work or changing cables on a display built into a structure you have to open all displays ABOVE the one you want to work on.
Lors de travaux de maintenance ou pour changement de câbles sur un écran intégré dans une structure, vous devez ouvrir tous les écrans au-dessus de celui que vous vou­lez travailler.
When a display which is built into a structure has to be de-mounted, first de­mount all displays above the one you have to de-install and then close the interfaces: This gives you free access to the display you want to remove and eliminates the risk of damaging the display hanging above when moving the system up!
Quand un écran qui est intégré dans une structure doit être démonté, au préalable démontez tous les écrans au-dessus de celui que vous devez désinstaller puis fermez les interfaces: Cela vous donne libre accès à l'écran que vous souhaitez enlever et élimine le risque d'endommager l'écran suspendu au­dessus lors du déplacement vertical du système!
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
__________________________________________________________________________
15
Page 16
1. Preliminary Remarks
When opening a display which is built into a structure, simultaneously press on the left and right bottom sides of the displays (there are the latches behind).
In case the interface frame does not open you very probably have a mixed situation of latches; one is opened, one closed. Then only press on the left OR on the right ot make the position of the latches the same.
Lors de l'ouverture d'un écran qui est intégré dans une structure, appuyez simultanément sur les côtés inférieurs droit et gauche de l’écran (il existe des loquets derrière). Dans le cas où le cadre de l'interface ne s’ouvre pas, très probablement vous faites face à une situation mixte de loquets; un ouvert, un fermé. Alors pressez sur celui de gauche ou de droite, ou mettez les loquets dans la même position.
1.2.4 Safety on shipping
Original shipping package
Save the original shipping packing material; they will come in handy if you ever have to ship one of your in­stalled modules. For maximum protection, repack your set as it was originally packed at the factory.
Keep the packing anti-moisture material or vinyl packing out of the reach of children. Anti-moisture material is harmful if swallowed. If swallowed by mistake force the patient to vomit and visit the nearest hospital.
Vinyl packing can cause suffocation. Keep it out of the reach of children.
1.2.5 Precautions
For your own protection, observe the following safety precautions!
Observe all warnings and instructions printed on the devices!
Check that the voltage and frequency of your power supply match those printed on the device label with the
rated electrical values!
Servicing not explicitly mentioned in this manual should never be carried out by unauthorized personnel!
Some parts of the body are hot during operation. Please be careful.
In case of moving long-distance, wrap the unit with blanket to avoid damages. Be careful not to bump the
unit.
Do not spray
Unused for long periods of time
For added protection for this video product during a lightning storm, or when it is left unattended an unused for long periods of time, unplug it from the wall outlet. This will prevent damage to the LCD module due to lightning and AC power-line surges
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
__________________________________________________________________________
16
Page 17
1. Preliminary Remarks
1.2.6 Unpacking of devices
Note advices on the packaging for unpacking!
1.2.7 Modification of devices
Mechanical or electrical modifications others than described in this manual must not be made to the devices. Barco is not liable for damages resulting from modified devices.
Only authorized personnel should carry out other maintenance work not explicitly mentioned in this user's manual!
Never open the case of the display without first disconnecting the device from the AC inlet. Measurements and tests with an opened device may be carried out only in the factory or by specially trained person­nel, due to the dangers of electrical shock.
Seul le personnel autorisé devrait effectuer d'autres travaux d'entretien qui ne sont pas explicitement mentionnées dans le manuel de l'utilisateur! Ne jamais ouvrir le boîtier de l'écran sans avoir d'abord débrancher l'appareil de la prise secteur. Mesures et essais avec un dispositif ouvert peuvent être effectués que dans l'usine ou par un personnel spécialement formé, en raison des dangers de décharge électrique.
1.2.8 Cleaning
Disconnect the device from the AC inlet.
Spray water onto a soft cloth 2 to 4 times, and use it to clean the front frame.
Scrub gently to prevent scratching. Wipe in one direction only! Too much moisture may cause staining.
Do not use benzene, paint thinner or alcohol!
1.2.9 Moving the product
Make sure to switch off the product.
• Make sure to unplug all cables from the product.
2 people carry each edge. Screen showing upwards.
1.2.10 Disposal or handing over to a new owner
It is recommended to initialize the unit by resetting it to factory's default.
Do not mix with other general waste.
Do not dispose the LCD display in waste treated by a waste treatment center.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
__________________________________________________________________________
17
Page 18
1. Preliminary Remarks
1.2.1 Environmental information: disposal information
This symbol on the product indicates that, under the European Directive 2012/19/EU govern-
ing waste from electrical and electronic equipment, this product must not be disposed of with other municipal waste. Please dispose of your waste equipment by handing it over to a des­ignated collection point for the recycling of waste electrical and electronic equipment. To pre­vent possible harm to the environment or human health from uncontrolled waste disposal, please separate these items from other types of waste and recycle them responsibly to pro­mote the sustainable reuse of material resources. For more information about recycling of this product, please contact your local city office or your municipal waste disposal service. For details, please visit the Barco website at:
http://www.barco.com/en/AboutBarco/weee
Disposal of batteries
This product contains batteries covered by the European Directive which must be collected and disposed of separately from municipal waste.
If the battery contains more than the specified values of lead (Pb), mercury (Hg) or cadmium (Cd), these chemical symbols will appear below the crossed-out wheeled bin symbol. By participating in separate collection of batteries, you will help to ensure proper disposal and
to prevent potential negative effects on the environment and human health.
Turkey RoHS compliance
Türkiye Cumhuriyeti: AEEE Yönetmeliğine Uygundur
[Republic of Turkey: In conformity with the WEEE Regulation]
1.2.2 Exemptions
This display is not liable for any damage caused by natural disaster (such as earthquake, thunder, etc.), fires, acts by third parties, accidents, owner’s intentional misuse and fault, or uses in other improper conditions.
This display is not liable for incidental damages (such as profit loss or interruption in business, modification or erasure of record data, etc.) caused by use or inability to use of this product.
This display is not liable for any damage caused by neglect of the instructions described in the owner’s man- ual.
This display is not liable for any damage caused by misuse or malfunction through simultaneous use of this product and the connected equipment or software.
This display is not liable for any damage caused by neglect of the instructions described about the installa- tion stand in the owner’s manual.
This display is not liable for any damage caused by improper installation.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
__________________________________________________________________________
18
Page 19
2. Mechanical setup
2 Mechanical setup
2.1 Tools needed for installation
Torx key size 30
Wrench key size 13, 15, 24
Hexagon key size 5, size 4
Hammer
• Tape, level
• Drilling machine, drill M10, M12, (M6)
• Level (1m)
Nylon construction line of 25m (wall mount only)
• Tape rule 5m (wall mount only)
The system needs to be fixed to the wall and to the floor. The anchors for this fixations are not included in the delivery!
The anchors have to be selected according the actual material of the wall /the floor.
X: number of system in horizontal direction (columns)
Y: number of systems in vertical direction (rows)
Required anchors for wall mount: X*Y*3 + X*4 (Size M8)
Required anchors for wall fixation: 2* (1 + roundup(Y/3)) * (X+1) (wall fixation brackets)
Required anchors for floor fixation: 2* (2*X) (floor fixation brackets)
Size: M10 (or M12) (wall fixation brackets, floor fixation brackets)
The structure is based on aluminum profiles which are mounted using alu corner brackets and hammer bolts. The hammer bolts are pre-assembled with a nut. This preassembly is inserted (hammer bolt head parallel to the groove of the profile) and then rotated by 90 degrees. Subsequently the nut is fixed.
The following table shows the required torque for fixing the screws. When tightening screws, please stick to these values!
Component Size ItemNo /description Torque Comment
Torx Screw (Metric)
M6 x 7 B362666 SCR
D7985TXM 6 X 7 STBK
min 3Nm; max 6Nm
screwed in Nut B358674 PF X ACC NUT SPGM6 B32-60
Hammer bolt M8X25, M8x20 B361304,B362864 15Nm For powder coated aluminum
covers
Hammer bolt M8X25, M8x20 B361304,B362864 25Nm For aluminum brackets
Headless screw M8X10 0.5 Nm Headless screws on T-bar
connectors
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
19
Page 20
3. Scope of delivery
3 Scope of delivery
The mechanics comprises three main components: the pedestal, the front access mount, and the display.
3.1 Front access mount
The front access mount module is the mechanics to house the display. Due to a sophisticated mechanism the unit can be opened on the front to enable cabling and dip switch setting without the need to go behind the structure.
It is available for installations with pedestals and for wall mount solutions.
3.2 Display
The monitor has an aspect ratio of 16:9 and HD resolution (1920x1080). It features the following interfaces:
OPS
OPS OPS Open pluggable specification channel with HDCP 1.4
DVI 1, DVI 2 DVI single link input with HDCP 1.4, up to 165 MHz)
HDMI HDMI 1.4a with HDCP 1.4, up to 300 MHz
DP DisplayPort input with HDCP 1.3, up to 300MHz
DP DisplayPort output with HDCP 1.4
S/PDIF Audio output interface according Sony/Philips Digital Interface specification
LAN 1, LAN 2 1 GB Ethernet input, video streaming supported.
USB USB interface USB 2.0
3.3 Pedestal
There are four standard pedestals, resulting in a lower screen edge of 875mm (R871674), 1000mm (R879302) and 1200mm (R871675), and 1500mm (R871676).
For all (standard) pedestals the components and the setup follow the same principle. In the manual, installation is shown for the standard pedestal unit 1000mm.
3.4 Wall mount
The Barco wall mount R876789 is the preferred solution for perfectly aligned large display walls. With third party wall mounts, the specified bezels of the displays may not be achieved!
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
20
Page 21
4. Adjustment of the mechanics for the display
4 Adjustment of the mechanics for the display
The front access mount and the pedestal are fit for KVD / IVD/ HVD displays. Whereas KVD and IVD have the same dimensions, the HVD displays are 2mm smaller, both in width and in height:
Dimensions KVD/IVD/OVD: 1213.4 x 684.2 x 98.3 | 47.77” x 26.94” x 3.87”
Dimensions HVD: 1211.4 x 682.2 x 102 | 47.69” x 26.85” x 4.015”
Thus the pedestal as well as the front access mount module need first to be adjusted to the display which needs to be installed.
4.1 Pedestal
The adjustment in width is done via spacers.
To change the horizontal dimensions, spacers are mounted to the left and to the right sight of a horizontal profile.
Since the difference in width between KVD and HVD is 2mm, at the left and at the right side a spacer of 1mm needs to be inserted – that’s why you have to unfold and break the part.
In case of OVD, KVD and IVD, these spacers are mounted on the left and right side of the horizontal profiles and of the cable hub:
In case of KVD and IVD: the support needs to be setup using these spacers!
In case of HVD: the support is setup without these spacers!
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
21
Page 22
4. Adjustment of the mechanics for the display
The spacer comes as a folded part with a total depth of 2mm and looks like this:
In case you need a spacer of 1 mm, you have to unfold this part and bend it sometimes to and fro to split it and to halve the depth:
For installation, only the part with the “nose” is required. Scrap the part without nose.
4.2 Front access mount module
The adjustment in width is done via spacers (same as with pedestals)
The front access mount module comes with the spacers installed.
In case of OVD, KVD and IVD: mount the front access mount module as delivered
In case of HVD: prior installation, remove the spacers, see chapter 5!
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
22
Page 23
4. Adjustment of the mechanics for the display
This is the profile for the front access mount. Please note the position of the spacers! This profile is completed by the NSL-5521 CNN SUP V4 to R879308 which looks like this:
This is the condition of delivery. In case of KVD and IVD displays, no adjustment in width of the horizontal profile (no removal of spacers) is required.
In case of HVD displays, remove the spacers to reduce the horizontal width by 2 mm.
Next to the adjustment in width, adjustment in height needs to be checked / done.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
23
Page 24
4. Adjustment of the mechanics for the display
The horizontal profile with the NSL-5521 CNN SUP V4 needs to be positioned according the height of the displays. Therefore a jig is included in the delivery.
The jig has two imprints, HVD5521 and KVD5521 (KVD5521 also applies for IVD5521, OVD5521).
For OVD/KVD/IVD displays, the condition of delivery should meet the needs also in vertical alignment. However it is advised to apply the jig to check the distance of the horizontal profile (and to adjust, if required).
Since the jig is used to define / check the distance of the horizontal profile of the current row to the horizontal profile of the row below (or the horizontal profile of the pedestal), the vertical alignment cannot be done upfront but is part of the installation procedure for every module.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
24
Page 25
5. Mechanical setup of display wall with pedestals
5 Mechanical setup of display wall with pedestals
5.1 Overview
The front mount system for displays comprises 3 parts: the pedestal (standard heights: 875mm, 1000mm, 1200mm, 1500mm), the front access mount module and the display.
The pedestals are setup with/without spacer depending on the display. WRT width: The front access mount module is used as is (in case of KVD/IVD) or the spacers are removed (HVD). The front access mount module is mounted onto the pedestal. Check/adjust the distance between the top horizontal profile of the pedestal and the horizontal profile of the
display module.
The display is mounted to the front access mount module.
For stability reasons the system has to be fixed to the floor (via the floor brackets) and to the wall (short / long wall fixation).
Every column of the system has to be grounded!
This is the installation sequence: Make a grid on the wall of the room where to fix the display wall. Drill the holes into the wall. Apply the required anchors. Mount the fixation brackets (wall side) Setup of all pedestals. All pedestals are connected (either linear or curved). The first row is mounted onto the pedestals In case of more rows: mount the second (and third) row. Attach the wall fixation brackets to the system (pedestal, third (or second) row). If applicable, mount the following rows Every third row has to be fixed to the wall. When all rows have been mounted and fixed according the rules mentioned above, the displays are mounted.
The structure is made of aluminum profiles, with a cross section of 90x45 or 45x45, respectively. Profiles are connected using alu corner brackets and "long nippled" hammer bolts B361304, M8x25.
There are two flavors of front access mounts, with air channel (legacy NSL-5521, left) and without air channel (OVD/IVD/KVD/HVD, right).
Most of the drawings show the system with air channel (but be aware that KVD/IVD/HVD/OVD DO NOT have front access mount with air channels!) The installation steps refer to both, systems with and systems without air channel.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
25
Page 26
5. Mechanical setup of display wall with pedestals
5.2 Preparation
5.2.1 Wall fixation
The systems need to be fixed to the wall.
Pedestal
01
This is the rule: Every column needs to be fixed to the wall. The first wall fixation is at the height of the ped-
estal top. Then every third row is fixed to the wall. If mounted with an angle to the wall always the
following wall fixation has to be mounted with the corresponding negative angle. Thus shearing forces are compensated.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
26
Page 27
5. Mechanical setup of display wall with pedestals
Pedestal
02
There are two type of wall fixation, a short one using a turnbuckle and a long one using a tele­scope bar.
The short wall fixation R868448 comprises a wall fixation bracket, an interface bracket to the struc­ture and a turnbuckle screw.
The turnbuckle screw can be set between 150
mm
and 315mm. It needs to be mounted to the wall with an angle.
The long wall fixation instead of the turn-buckle comprises a long telescope bar which allows set­ting a (perpendicular) distance between 554mm and 1106mm
. Use an appropriate angle to realize
the actual distance. If required, drill additional holes to lock the tele-
scope bar arrangement!
Fixation material to the wall is not included in the
delivery. It has to be M10 and selected according the material of the wall to withstand the forces.
Pedestal
03
First the wall fixation brack
ets are attached to the
wall, cf. Mounting the wall fixation brackets for video
walls with (kind of standard) supports
Subsequently the interface bracket to the struc­ture is mounted. It is fixed using two hammer bolts.
It can be fixed at the back side of the vertical pro-
file or, if it can be reached, also on the side of the
vertical profile.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
27
Page 28
5. Mechanical setup of display wall with pedestals
Pedestal
04
When making the connection to the wall it is rec­ommended to keep the turn-buckle as horizontal as possible, i.e. the eyes are plane: this ensures the quality of connection.
Pedestal
05
Top view on wall fixation. Please mind the fixation angles: make as much
opposite pairs as possible.
(If possible (depends from the overall distance to
the wall and the set length of the outer turn­buckles) make the mid wall fixation perpendicu­lar to the wall.)
5.2.2 Mounting the wall fixation brackets for video walls with (kind of standard) supports
Since the system is installed nearby the wall at minimum distance it gets very difficult to fix the brackets to the wall after the video wall has been setup.
Therefore it is recommended to first drill the holes to the wall and to mount the wall fixation brackets before setting up the video wall.
Fixation material to the wall is not included in the delivery. It has to be M10 and selected according the material of the wall to withstand the forces.
Walls of re-enforced concrete of quality C20/25 or higher with a thickness of at least 16cm are required. For wall fixation, the edge distance as to be 200mm or higher!
In any case fixation needs to be done on multiple levels: first on the support plane (screen height), and then on the top of every third row (rows<=3) or on the top of the last row(rows<3).
The figures in the table refer to KVD and IVD displays.
Number of rows
Level -1 (measured from level 0)
Level 0 (top of pedestal, screen height)
Level 2 (measured from level 0)
Level 3 (measured from level 0)
Level 4 (measured from level 0)
1 -120 491.7
2 -120 1178.35
3 -120 1865
4 -120 1865 2551.65
5 -120 1865 3238.3
6 -120 1865 3924.95
7 -120 1865 3924.95 4611.6
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
28
Page 29
5. Mechanical setup of display wall with pedestals
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
29
Page 30
5. Mechanical setup of display wall with pedestals
Pedestal
06
Select the appropriate chemical anchor for wall fixation.
The anchor needs to resist the pull out force of
0.5kN.
Anchors of type M10 are required.
Pedestal
07
Make the fixation grid on the wall. You might want to use tape to make the grid. Start with a line for level1, i.e. support plane
(screen height). Make sure that the line is per­fectly straight and levelled!
Subsequently add a line for the additional levels of the setup, see table above.
Also mark the total width of the columns. As reference, use the center of level 0, (center of
the base line).
Pedestal
08
After pre-drilling, proceed with drilling the holes according the selected chemical anchor.
When all holes are drilled, mount the wall fixa­tion brackets.
The wall fixation bracket comprises the part mounted to the wall and the parts mounted to the video wall structure.
The part mounted to the wall comes pre­assembled and needs to be fixed to the wall by means of two chemical anchors, M10.
It is recommended to also fix the bracket later mounted to the video wall to the wall fixation. Use the screw M8, the self locking nut and wash­ers
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
30
Page 31
5. Mechanical setup of display wall with pedestals
Pedestal
09
When all wall fixation brackets have been mounted, start with setup and installation of the pedestal.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
31
Page 32
5. Mechanical setup of display wall with pedestals
5.3 Connection concept
The pictures show the connection concept implemented in the KVD5521video wall. In vertical direction, all connections are made via T-bar connectors which come inserted into the profile. The T-bar connector features 4 headless screws which we will number 1, 2, 4, 3, starting at the bottom. It
comes with the bottom screw (1) and top screw (3) fixed. These screws need to be loosened to shift up the T-bar connector. When it had been shifted up it is fixed again by the bottom screw (1) – and only by the bottom screw. The
screw is not fully tightened so that the T-bar connector can still "rattle". Before placing another system on top, the connection plates need to be inserted. There are two types of
connection plates: single (to be placed on the outer left/right profile, and double (to be placed on horizon­tally adjacent profiles).
When the connection plates are in place the screw (2) gets fixed, but
only at the front
of the video wall.
Subsequently the next system is placed on top of the current one. The screw (3) gets fixed, on the front and on the rear side of the video wall. Subsequently the screw (4) gets fixed (front and rear side) as well as the screw (2) on the rear side.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
32
Page 33
5. Mechanical setup of display wall with pedestals
5.4 Installation of the pedestal
The following table shows the components of the pedestal 1200mm, R876787. Except for the length of the verti­cal profiles (R869377), the components of all pedestals are (almost) identical.
Article no.
Description
Quantity
picture
R879297
NSL
-5521 PED TOP V4
1
1
R867141
FRMC NSL1 PF Y 906.6
2
7
R879296
NSL
-5521 PED PF X V4
1
8
B361304
SCR ASS D188K M8X25 STZN
20
9
R867120
FRMC NSL1 FEET SUP
2
10
B356318
FOOT REG D45 H145 M16STST
2 11
B360780
WSHR D433 D17 D28 SS
2
G235531
NUT D934 M16 STZN
2
R869262
FRM NSL1 FLOOR BRKT
2
12
R867885
FRMC NSL1 TRIPOD
4
2
R879299
NSL
-5521 CABLE HUB V4
1
5
R870780
FRM NSL1 TOP CNN HOLDER
2
6
R858766
FRMC NSL1 PWR STRIP SUP
1
3
R819000
FRM ATL67C4 CBL TIE HLR
3
4
A577351
CBLA TIE B L400 W5
10
R879298
NSL
-5521 PF PIN CNN HOR V4 6 13
B593021
BOXKIT NSL
-5521 PED
1
R591702
LBL GENERIC 148X105 PCK
1
R764734
GROUNDING KIT OVERVIEW C
1
Pedestal
10
The vertical profiles have a cross section of 90x45.
In the following the part where the foot is insert­ed will be called "rear part".
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
33
Page 34
5. Mechanical setup of display wall with pedestals
Pedestal
11
The vertical profile comes with the foot already installed.
The foot is mounted on the "rear" part of the pro­file.
Check the length of the foot: It should be 65mm.
Pedestal
12
KVD/IVD/OVD:
In total 6 spacers à 1mm are required. Unfold the
spacers, bend them to and fro, and halve them. Scrap the part without nose.
Pedestal
13
KVD/IVD/OVD: On the left and on the right, apply the spacer to
the horizontal profile. The nose needs to slide in­to the groove.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
34
Page 35
5. Mechanical setup of display wall with pedestals
Pedestal
14
The horizontal profile R879296 (45x45) comes with the aluminum corner bracket already mounted at each end.
The horizontal profile is connected on the "front" part of the profile.
Position the horizontal profile on the "front" part of the left vertical profile and fix the already mounted aluminum corner of the horizontal pro­file also to the left vertical profile with one ham­mer bolt B361304.
Proceed accordingly with the right vertical profile.
Make sure that the profiles are properly aligned and that there is a smooth surface on the joint.
"Rear" and "front" are meant with respect to the final video wall: front is the side to the opera­tor/viewer.
Pedestal
15
The top of the pedestal comes already preassem­bled with the top horizontal profile.
Pedestal
16
In case of OVD, KVD and IVD displays: On the left and on the right, apply the spacer!
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
35
Page 36
5. Mechanical setup of display wall with pedestals
Pedestal
17
Install the top of the pedestal. Fix the alu corner of the top horizontal profile
(part of the top of the pedestal) to the left/right "front" vertical profile using 2x one hammer bolt
Pedestal
18
Align the profiles!
Pedestal
19
In case of OVD, KVD and IVD: On the left and on the right of the cable hub, ap-
ply the spacer!
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
36
Page 37
5. Mechanical setup of display wall with pedestals
Pedestal
20
Install the cable hub R879299. It is mounted to the pedestal top via two hammer bolts, and to each of the vertical profiles with 1 hammer bolt.
Make sure that the "tray" shows to the rear! Subsequently mount the power strip using two
hammer bolts.
Pedestal
21
Level the pedestal.
Pedestal
22
Start with mounting the feet to the feet support brackets R867120.
On the bottom of the feet support bracket there is
a welded nut to screw in the foot.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
37
Page 38
5. Mechanical setup of display wall with pedestals
Pedestal
23
Screw in the foot for nominal height (= feet height of "rear" foot + profile cross section = 65mm + 45mm) = 110mm
Fix each foot with a washer and a nut (B360780, G235531)
Pedestal
24
The feet support bracket as a cut out for the alu corner bracket which connects the horizontal and the vertical profiles.
Place the feet support bracket using this cut out. Fix the feet support bracket to left/right vertical profile using 2x two hammer bolts.
Fix the feet support bracket to the left/right ver­tical profile using two hammer bolts.
Pedestal
25
Also attach the cable tie holders to the rear pro­file (below the power strip)
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
38
Page 39
5. Mechanical setup of display wall with pedestals
Pedestal
26
When the pedestal has been assembled, two ce
n-
tering pins R867885 have to be inserted into the left and right vertical profile.
These centering pins ensure that the final struc­ture will be perfectly aligned.
Pedestal
27
Hammer in the pins.
Pedestal
28
Make sure to align the pins with the top of the profile!
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
39
Page 40
5. Mechanical setup of display wall with pedestals
Pedestal
29
The vertical profiles come with T-bar connectors attached.
These T-bar connect
ors are fixed with the top and
the bottom screw.
Pedestal
30
Loosen the headless screws and shift the T-bars up until the bottom screw of the T-bar connector matches the hole in the profile.
Fix the bottom screw of the T-bar connector to the hole in the profile!
Please refer also to the connection concept, cf.
Connection concept
Pedestal
31
When the first pedestal has been mounted and prepared like described in the previous steps,
also prepare all other pedestals of the configura­tion like this!
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
40
Page 41
5. Mechanical setup of display wall with pedestals
Pedestal
32
When all pedestals have been assembled, place them next to each other.
Choose one of them as the master: This will be the reference to align all other supports.
It is recommended to set the center system as master!
Carefully level all pedestals with reference to the master! This effort takes time, but it defines the final quality of the full setup!
Make sure that all hammer bolts are tightened!
Pedestal
33
Make sure that the profiles are well aligned, also in height! In case of a curved setup it is mandato­ry to align them before mounting the connection brackets.
But also with a linear configuration it is recom­mended to have the profiles aligned in height.
If required, adjust the height be screwing the feet
in/out. Do not touch the master system!
Pedestal
34
Proceed with connecting the pedestals: R868444: linear connection R868445: curved 3 degree R868446: curved 5 degree R868447: curved 8 degree
The connection kits comprise a front and a rear part.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
41
Page 42
5. Mechanical setup of display wall with pedestals
Pedestal
35
Start with mounting the front connection part. Use two hammer bolts to fix it. Make sure that it is properly aligned (smooth surface on the bot­tom of the profile).
Make sure that the "noses" dig into the grooves of the profile!
Pedestal
36
Fix the rear connection part using two hammer bolts.
Make sure that it is properly aligned! Make sure that the "noses" dig into the grooves
of the profile.
Pedestal
37
Make sure that all hammer bolts are properly tightened! (Torque about 15 Nm for powder coat­ed aluminum, 25Nm for alu corner brackets.)
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
42
Page 43
5. Mechanical setup of display wall with pedestals
Pedestal
38
When the bottom connection has been made on all pedestals, the top connection plates have to be installed.
Installation of the top connection plates will be needed also on all rows.
For installation of the top connection plates it is mandatory that the pedestals are accurately lev­eled!
Pedestal
39
R869697: connection part, 3 degrees R869698: connection part, 5 degrees R869699: connection part, 8 degrees R869695: linear connection part R869696: side part
Pedestal
40
Installation of the connection parts is done best when standing in front of the structure.
Place the connection part over the centering pins; start with sliding the rear part (bigger diameter) over the rear centering pins.
Subsequently slide the front part over the front centering pins.
To ease installation, the T-bar connectors still need some play.
S
Pedestal
41
To ease installation, the T-bar connectors still need some play.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
43
Page 44
5. Mechanical setup of display wall with pedestals
Pedestal
42
Hold the connection part in place by pushing it against the surface of the profile while gently fix­ing the second screw from the bottom (torque approx. 0.5Nm).
Only fix the second screw on the
front side, please refer also to the Connection
concept.
When fixing the screw the plate moves forward and starts clamping the pins with the smaller di­ameter.
The position of the connection part is thus fixed. Please note: the T-bar connectors still need to be
able to move a little!
Pedestal
43
Proceed with mounting the connection plates on all supports.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
44
Page 45
5. Mechanical setup of display wall with pedestals
Pedestal
44
Also mount the single connection plates on the outer profiles!
Pedestal
45
To ensure a good installation we need to verify the curvature after setting up the supports
In the following you find the rules for measure­ment for a setup of 3degrees, 5degrees, and 8degress.
Make sure that the setup matches the distances!
Pedestal
46
Measuring points: Outer edge of a single connection part (see detail A) or the respective edge of a double connection part (see
detail B)
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
45
Page 46
5. Mechanical setup of display wall with pedestals
3degrees:
If you use a measuring cord between the outer profiles of two systems the distance of the measuring cord at the junction of the system is 31.3mm
5degrees:
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
46
Page 47
5. Mechanical setup of display wall with pedestals
If you use a measuring
cord between the outer profiles of two systems the distance of the measuring cord at the
junction of the system is 52.6mm.
8degrees:
If you use a measur
ing cord between the outer profiles of two systems the distance of the measuring cord at the
junction of the system is 84.6.
Pedestal
47
Fix the supports to the wall fixation brackets al-
ready attached to the wall during the preparation
phase.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
47
Page 48
5. Mechanical setup of display wall with pedestals
5.4.1 Preparation of front access mount module (non-top row)
Pedestal
48
The upper system features an air channel (NSL-5521)
The lower system does not feature an air channel
(OVD5521, KVD5521, IVD5521, HVD5521).
The following pictures and steps apply for OVD/KVD/IVD/HVD
although some of the pictures
show the NSL-5521 system with air channel.
Pedestal
49
In case there is only one row, you may skip this chapter.
Pedestal
50
Unscrew the headless screws S1, S3. Move up the T-bar connectors (the bottom of the
T-bar connectors have a distance of 79mm from the top of the profile).
Fix the T-bar connector to the vertical profile
with
screw S1 (bottom screw , mounted to the hole of the profile).
Make sure not to fix it too tight. It should be able to rattle (fixed in height but with some play in the slot).
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
48
Page 49
5. Mechanical setup of display wall with pedestals
5.4.2 Preparation of front access mount module, top row
Pedestal
51
Prepare the front access mount modules of the last rows:
Front T-bar connectors: Shift the T-bar connectors slightly up until it has
an offset to the top of the profile of about 15mm. Only fix the bottom screw of the T-bar connector.
Pedestal
52
Rear T-bar connectors: Shift the T-bar connectors slightly up until it has
an offset to the top of the profile of about 5mm. Fix the screws..
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
49
Page 50
5. Mechanical setup of display wall with pedestals
5.4.3 Installation of the front access module, first row
Pedestal
53
The upper system features an air channel (NSL-5521)
The lower system does not feature an air channel
(OVD5521, KVD5521, IVD5521, HVD5521).
The following pictures and steps apply for KVD5521although some of the pictures show the NSL-5521 system with air channel.
Pedestal
54
In case of HVD: Remove the left (or right) spacers NEVER remove the horizontal profile completely
from the vertical profiles. Proceed like this: Start with the left (or right) side. Open the screws which fix the horizontal profile
to the vertical profile (2x
B361304 SCR ASS D188K
M8X25 STZN). While the right (or left) side of the horizontal pro-
file is still fixed to the vertical profile, push the horizontal profile back to remove the spacer.
Subsequently restore the position of the horizon­tal profile.
Use 2x B361304 SCR ASS D188K M8X25 STZN and fix the horizontal profile to the left (or right) ver­tical profile.
LEVEL the horizontal profile to maintain the refer­ence distance!
Subsequently remove the right (or left) spacer.
Perform these steps also on the right (or left) side
to remove the spacer on the right (or left). Make sure that you keep and maintain the posi-
tion of the horizontal profile!
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
50
Page 51
5. Mechanical setup of display wall with pedestals
Pedestal
55
Please note:
Due to the difference in height between KVD/IVD
panels and HVD panels, the lower edge of the display in case of HVD panels is 1mm
higher than
the nominal height, e.g. 876mm for 875mm ped­estals. This is within the tolerances.
Pedestal
56
With all displays: position the front access mount module on the
pedestal. To ease assembly place the module as parallel to
the pedestal as possible. The T-bar connectors of the pedestal
slide into the
vertical profiles of the front access mount mod­ule.
The "ears" of the front access mount module
slide
into the cutouts of the pedestal's top.
Pedestal
57
Fix the first front access mount module to the support like this:
Tighten the top screw (S3) of all 4 T-bar connect­ors.
Then tighten the screw (S4) of all 4 T-bar con­nectors.
Finally tighten the screw (S2) of the rear T-bar connectors.
Please note: Fixing the top and the bottom screw presses the
vertical profiles of the front access mount module
and the pedestal together and ensure a zero gap.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
51
Page 52
5. Mechanical setup of display wall with pedestals
Pedestal
58
Subsequently fix the ears of the front access mount module to the horizontal profile of the t
op
of the pedestal, using 2x two M6x7 screws B362666.
Pedestal
59
Proceed accordingly with the next front access mount modules.
If required (HVD panels), remove the spacers, see
above. Shift the T-bar connectors up like described
above, and place the front access mount module as parallel as possible over the pedestal.
Slide it into the T-bar connectors of the pedestal.
Pedestal
60
If you have to fix all T-bar connectors from front, access to the rear T-bar connectors is only possi­ble when shifting up the rear cover.
Shift the rear cover upwards to reach the screws at the rear side of the center profile.
Fix the T-bar connectors of the seconded front ac­cess mount module. Mind the correct sequence:
First fix the top screw of all T-bar connectors, Then fix the bottom screw of all T-bar connectors, Then all the other screws.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
52
Page 53
5. Mechanical setup of display wall with pedestals
Pedestal
61
Install all front access mount modules of the first row.
Pedestal
62
When all front access mount modules of the first row have been mounted,
place the connection plates. Proceed as described when installing the connec-
tion plates on the pedestals: Stand in front of the system. First slide the rear side (bigger diameter) onto
the centering pins, then the front size (smaller diameter, T-groove). Hold down the connection
plate while carefully fixing the second screw from
the bottom of the T-bar connector. Do not forget to place the single element onto
the sides.
For a curved setup you can use a measuring chord to check the alignment:
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
53
Page 54
5. Mechanical setup of display wall with pedestals
5.4.4 Installation of the second row
Pedestal
63
In case of HVD: Remove the left (or right) spacers NEVER remove the horizontal profile completely
from the vertical profiles. Proceed like this: Start with the left (or right) side. Open the screws which fix the horizontal profile
to the vertical profile (2x
B361304 SCR ASS D188K
M8X25 STZN). While the right (or left) side of the horizontal pro-
file is still fixed to the vertical profile, push the horizontal profile back to remove the spacer.
Subsequently restore the position of the horizon­tal profile.
Use 2x B361304 SCR ASS D188K M8X25 STZN and fix the horizontal profile to the left (or right) ver­tical profile.
LEVEL the horizontal profile to maintain the refer­ence distance!
Subsequently remove the right (or left) spacer.
Perform these steps also on the right (or left) side
to remove the spacer on the right (or left). Make sure that you keep and maintain the posi-
tion of the horizontal profile!
Pedestal
64
The difference in height of the panels requires to
check/adjust the position of the horizontal profile
with the front access mount. Therefore jig R872756 is included in the delivery.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
54
Page 55
5. Mechanical setup of display wall with pedestals
Pedestal
65
The front access mount comes pre-installed for OVD/KVD/IVD. However it is recommended to use the jig and check the distance!
Use the jig R872756. Apply the jig on the front side of the front access
mount module. In case of OVD/
KVD/IVD: make sure that the jig is
used showing imprint KVD on top!
Pedestal
66
The front access mount comes pre-installed for OVD/KVD/IVD.
For HVD, you need to re-position the horizontal profile.
Use the jig R872756. Apply the jig on the front side of the front access
mount module. In case of HVD: make sure that the jig is used
showing imprint HVD on top!
Pedestal
67
Shift the jig to the left and the right side of the horizontal profile.
(Every front access module comes with one jig.
Since the jig is only required for rows >=2 you can
use also the jig of the front access modules in­stalled in row = 1.)
On the left and on the right, use 1x B361304 SCR ASS D188K M8X25 STZN and fix the jig on the top horizontal profile of the row below!
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
55
Page 56
5. Mechanical setup of display wall with pedestals
Pedestal
68
On the top horizontal profile of the current row, loosen the fixation screws from the vertical pro­file (about 2-3 turns) (so that the horizontal pro­file can move)
On the left and on the right, use 1x B361304 SCR ASS D188K M8X25 STZN and fix the jig on the top horizontal profile of the current row.
The vertical edge of the cut out flushes with the back of the horizontal profile.
Pedestal
69
Install the second row accordingly.
When sliding the following front access mount module onto the previous front access mount module, you have to push the "ears" of the fol­lowing module back to make them slide into the previous module.
Pedestal
70
When fixing the T-bar
connectors, mind to first fix
all top screws, then all bottom screws, and then the other screws.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
56
Page 57
5. Mechanical setup of display wall with pedestals
Pedestal
71
When the T-bar connectors are fixed, the front ac­cess mechanism of vertical adjacent modules has to be connected.
Fix it with 4 screws M6x7 (B362666).
Pedestal
72
When the second row has been installed, level the system!
This will noticeable facilitate the installation!
Pedestal
73
Apply the connection plates as described above. Mind to place also the single elements!
In case of a curved setup, use a chord to check the alignment as described above.
Pedestal
74
If the row needs to be fixed to the wall (see table
of fixation levels), fix the modules to the already attached wall fixation brackets.!
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
57
Page 58
5. Mechanical setup of display wall with pedestals
Pedestal
75
In case of the top row, place the connection holders onto the connection plates.
The connection holders ensure that the connec­tion plates stay in place.
It is due to the connection holders that the T-bar connectors of the top row need to have an offset of 15mm.
Pedestal
76
For proper grounding, apply the self cutting screw
G205790 to every column!
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
58
Page 59
5. Mechanical setup of display wall with pedestals
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
59
Page 60
5. Mechanical setup of display wall with pedestals
5.5 Floor fixation of the display wall
Pedestal
77
For safety reasons the video wall has to be fixed to the wall.
Before it is fixed to the wall the position on the floor has to be fixed. This is done by means of th
e
floor fixation brackets.
Pedestal
78
Apply the brackets on each foot. Fix the brackets to the floor by means of a chemi-
cal anchor, either M10. Mind to select the appropriate anchor according
the floor material. Every fixation point has to withstand a pull out
force of 0.5kN.
In case of false floor: Make sure that the bracket is fixed to the concrete!
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
60
Page 61
5. Mechanical setup of display wall with pedestals
5.6 Finalizing the structure
Pedestal
79
When the entire system is set up, gaps between the profiles of the front sides of the front access mount modules have to be covered with black tape.
The black tape prevents light leak from behind the structure.
Pedestal
80
If the entire structure is fixed to the wall accord­ing the rules (cf. Pedestal 01
) and the floor posi-
tioning brackets are applied and fixed to the floor
it is possible to remove the front feet.
Pedestal
81
Due to the reduced height (-2mm) of HVD panels the vertical profiles “protrude” some millimetre on the top of the display wall.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
61
Page 62
6. Mechanical setup of display walls with wall mount solutions
6 Mechanical setup of display walls with wall mount solutions
Pedestal
82
The upper system features an air channel (NSL-5521)
The lower system does not feature an air channel
(OVD5521, KVD5521, IVD5521, HVD5521).
The following pictures and steps apply for OVD/KVD/IVD/HVD
although some of the pictures
show the NSL-5521 system with air channel.
Wall mount
01
The NSL wall mount solution is based on alu­minium profiles fixed to the wall
Wall mount
02
The mechanics to house the panels hangs in these aluminum profiles
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
62
Page 63
6. Mechanical setup of display walls with wall mount solutions
Wall mount
03
The bottom row gets additional fixed using a left and a right support bracket per system.
This bracket consists of two plates and thus also
provides an alignment facility.
Wall mount
04
The vertical position of the bottom brackets de­fines the screen height.
The position of the aluminum profile of the bot­tom row is 606mm above screen height. (= dis­tance between bottom bracket and first alumi­num profile)
The distance between the alu
minum profiles of
adjacent rows 686.6mm (NSL5521), 684.2mm (OVD/KVD/IVD) or 682.2mm (HVD).
Wall mount
05
HVD displays are two millimetres less in width than OVD/KVD/IVD displays.
Therefore the wall mount profiles protrude some millimetres on the left (or right, or on both sides, depending on your preference and the number of installed displays in a row)
Wall mount
06
It is obvious that such installations require flat­ness of the wall.
The standard KVD Wall Mount package is equipped to cover differences in the building wall flatness of maximum 7mm.
When bigger differences occur they should be taken care of by the building-, or facility man­ager.
If not respected they can have an impact on the
proper functioning of the product as well as on the overall image quality.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
63
Page 64
6. Mechanical setup of display walls with wall mount solutions
Wall mount
07
Start with drawing the horizontal lines of the grid for your installation.
The bottom horizontal line defines the screen height.
The entire height of the installation calculates to
OVD/KVD/IVD: Y = screen height + 603.6mm + (number of
rows -1)*684.2 HVD: Y = screen height + 601.6mm + (number of
rows -1)*682.2
Wall mount
08
When the horizontal lines are drawn, apply the top most aluminum profile to mark the exact position of the holes.
Check for proper alignment!
Wall mount
09
You might also consider to first connect the aluminum profiles using the t-bar connectors.
Insert the t-bar connectors into the profiles and fix them using the headless screws (the screws will cut through the profile)
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
64
Page 65
6. Mechanical setup of display walls with wall mount solutions
Wall mount
10
You might also consider to first connecting the aluminum profiles using the t-bar connectors.
Insert the t-bar connectors into the profiles and fix them using the headless screws (the screws will cut through the profile)
Check for proper alignment!
Wall mount
11
In case the number of columns does not allow connecting all profiles in advance,
Drill the holes for the first profile. Fix this profile to the wall. Mark and drill the holes for the adjacent profile. Connect the adjacent profile and fix it. Always check the alignment!
Wall mount
12
Drill the holes The values X and Y are defined by the type of
anchor.
The anchors are not part of the delivery but need to be selected according the type of the building wall and the required pull-out force.
Anchor interface: diameter M8 clamp range 20mm pull-out force 1.2kN
Wall mount
13
Fix the profiles using the anchor and the wall mounting plate R872581. The wall mounting plate serves for perfect alignment!
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
65
Page 66
6. Mechanical setup of display walls with wall mount solutions
Wall mount
14
The anchors need to be fixed according the se­quence indicated in the picture.
In case the profiles are not pre-assembled, do not fix the anchors tightly until the adjacent profile has been attached and fixed, too.
Check the alignment!
Wall mount
15
When the top most aluminum profile has been fixed and aligned, use the wall mount drill R804159 to find the position of the holes for the row below.
The wall mount drill has two cut-outs on top and bottom for finding the correct horizontal position.
Its hole on bottom defines the position of the drilling hole for the row.
Make sure to use it correctly! Mind the imprints KVD (for OVD/KVD/IVD) and HVD!!
Wall mount
16
Apply the jig. The left edge of the
aluminum profile is aligned
to the "nose". Mark the left hole for fixation of the lower alu-
minum profile. Subsequently shift the jig to the right and
apply
the jig with a distance of 607mm between the right edge of the jig and the left edge of the profile.
Mark the mid hole for fixation of the lower aluminum profile.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
66
Page 67
6. Mechanical setup of display walls with wall mount solutions
Wall mount
17
To find the position of the right hole for fixation
of the lower profile proceed like this: Rotate the jig vertically. The right edge of the aluminum profile gets
aligned to the "nose". Mark the right hole for fixation of the lower
aluminum profile.
Wall mount
18
Drill the holes for the lower profile and fix it slightly using anchors and wall mounting plates.
Wall mount
19
Apply the jig on the left (the edge of the upper aluminum profile needs to be in the cut-out of the jig) and check the distance between the aluminum profiles!
Check the leveling!
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
67
Page 68
6. Mechanical setup of display walls with wall mount solutions
Wall mount
20
Apply the jig on the right (the edge of the low­er aluminum profile needs to be in the cut-out of the jig) and check the distance between the aluminum profiles!
Check the leveling!
Wall mount
21
On the left, use a plumb line and check the z alignment (distance to the wall)
Wall mount
22
If required, insert a spacer. Spacers are available with 1mm, 2mm, and
4mm and allow compensating differences up to
7mm.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
68
Page 69
6. Mechanical setup of display walls with wall mount solutions
Wall mount
23
On the right, use a plumb line and check the z alignment (distance to the wall)
Wall mount
24
Check the distance! Check the z-alignment. Check the leveling! When the alignment is perfect, tighten the an-
chors one by one. Start with the most left one, Subsequently fix the most right one Next fix the second left one Next the second right one And so on, always alternating left/right.
Wall mount
25
The frames will be fixed via 2 hammer bolts to the aluminum profile
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
69
Page 70
6. Mechanical setup of display walls with wall mount solutions
Wall mount
26
Start with the bottom row!
Apply the control jig to find R804158 the posi­tion of the most left frame on the aluminum profile.
Wall mount
27
Fix the frame with 3 hammer bolts. Left and right hammer bolt: Make sure to apply
a washer for proper grounding!
Wall mount
28
Apply the control jig to find the position of the adjacent frame of the same row.
Hang the frame in. Fix it with 3 hammer bolts Left and right hammer bolt: Make sure to apply
a washer for proper grounding!
Proceed until all frames of the bottom row are fixed.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
70
Page 71
6. Mechanical setup of display walls with wall mount solutions
Wall mount
29
Mount the bottom brackets­Fix each of it with two screws M6x7 B362666.
Wall mount
30
Ground the row using a screw M4.8x16, G2059790.
The screw needs to be applied to the most left frame (seen from front).
Wall mount
31
Hang in the frames of the second row. When sliding the top frame onto the bottom
frame, you have to push the "ears" of the top
frame back to make them slide into the bottom
frame.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
71
Page 72
6. Mechanical setup of display walls with wall mount solutions
Wall mount
32
Fix each frame with 2x 2 screws M6x7 B362666.
Wall mount
33
Also ground the second row using a screw M4.8x16, G2059790.
The screw needs to be applied to the most left frame (seen from front).
Wall mount
34
Proceed accordingly until all frames are fixed to
the aluminum profiles.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
72
Page 73
6. Mechanical setup of display walls with wall mount solutions
Wall mount
35
Drill the holes for the bottom brackets The values X and Y are defined by the type of
anchor.
The anchors are not part of the delivery but need to be selected according the type of the building wall and the required pull-out force.
Anchor interface: diameter M8 clamp range 20mm pull-out force 1.2kN
Wall mount
36
Drill the holes.
Wall mount
37
Use a vacuum cleaner and remove the drilling dust.
Wall mount
38
Fix the bottom brackets.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
73
Page 74
6. Mechanical setup of display walls with wall mount solutions
Wall mount
39
Optional: Apply the caps to the left and right edges of
the aluminum profiles.
Wall mount
40
Check the alignment! If required, shift the frame on the bottom
bracket.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
74
Page 75
7. Cabling
7 Cabling
This chapter refers to systems with pedestals and to systems with wall mounts. There is no difference in cabling of these two solutions. The pictures usually show the pedestal setup.
7.1 Cabling
Step
01
The picture shows the principle of power cabling. Power cabling is done column wise. Up to three systems can be connected to one
power strip. Never cascade power strips!
Cabling is done from front! The cables are guided BEHIND the sheet metal of
the gas spring mechanism!
Step
02
Care for a clear layout of the cabling.
To guide and fix the cables the structure provides cable tie holders.
The cable tie is inserted into the square duct of the cable tie holder, and then the cable tie is bound around the cables and closed.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
75
Page 76
7. Cabling
Step
03
These are the cable tie holders to fix cables with­in a column.
Step
04
In general there are the following types of ca­bling:
Power cabling Data cabling LAN cabling for controlling via BCM. Power cabling is done per column, from top to
bottom (the power strip is mounted on the ped­estal)
Which signal cables are needed and how they are
connected, depend on specific customer require­ments.
Step
05
There is one thing in common: It is mandatory to reserve a length of approx. 870mm (excluding the connector) to have enough cable length available when swinging the monitors to the front.
To ensure that the cables are long enough to al­low swinging the monitor, proceed as follows:
Bundle all cables. Measure approx. 870mm (exclude the connector)
Bind this cable tie round the measured position of
the cable bundle and close it.
Cabling is done from front!
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
76
Page 77
7. Cabling
Make sure to guide the cables BEHIND the sheet metal of the gas spring mechanism!!
(The picture shows a setup wi
th pedestals but the
cabling principle is the same for wall mount solu­tions!)
Step
06
Make sure to guide all cables. Fix them using the cable tie holders (vertical di-
rection) and the fixation holes (horizontal direc­tion).
Care for a clear layout.
Step
07
For LAN cabling / BCMC please refer to the user manual of Barco Wall Control Manager.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
77
Page 78
7. Cabling
7.2 Grounding
Step
08
Grounding comprises fixation of the grounding cable to every pedestal.
The connection of the grounding cable to the power net has to be done by a qualified electri­cian, ordered by the customer.
To ground a column, proceed as follows: Arrange the fixation material in the correct order. Unscrew the nut from the hammer bolt. Insert the contact washer, pin side to hammer
bolt head. Subsequently insert the annular cable lug, then
the plain washer. Loosely attach the nut.
Step
09
Setup with pedestal: Insert the pre-assembled hammer bolt into the
right vertical profile, turn it, and fix it in a dis­tance of approx. 13cm measured from the floor.
Attach the grounding label about 20mm above the connection point.
Step
10
Setup with wallmount: Insert the pre-assembled hammer bolt into the
bottom aluminum profile, turn it, and fix it. Attach the grounding label about 20mm above
the connection point.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
78
Page 79
8. Installation of the displays
8 Installation of the displays
This chapter refers to systems with pedestals and to systems with wall mounts. There is no difference in in­stalallation of the monitors. The pictures usually show the pedestal setup.
24 hours prior to installation/taking into operation the LCD displays have to acclimatize to the room!
Do NOT open the bag during this time and keep the LCD displays in the card box. Only after this period, lift the LCD displays out of the box.
Step
11
When all cabling is in place the monitors can be mounted.
Before unpacking the monitors, prepare the structure to accommodate the monitors.
Step
12
The front access mount comes completely as­sembled, the picture at the left just serves giv­ing an "inside view".
The front access mount features an interface frame where the monitors are attached to.
This interface frame is enabled to swing forward
to give access to the rear of the monitor (to set dip switches, or to plug/unplug cables).
The mechanism is based on two gas springs, one
at the left and one at the right side. When the gas springs are snapped in, the inter-
face frame is in the back position. Releasing the gas springs is done by pushing a
latch: the interface frame will swing forward. To bring it back again, push the interface frame
firmly back until the latch is in closed position.
The gas spring is quite strong! Therefore in the following steps make sure that
you hold the frame firmly back! Otherwise you risk that the frame hits into your face!
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
79
Page 80
8. Installation of the displays
Step
13
For transportation security, the interface frame
is
locked by means of two transportation lock screws, one at the left and one at the right
Please note: The latches may be in the open position and
thus the interface frame might swing forward in
an uncontrolled way!
Step
14
Take care! Hold the frame into position! Only remove one transportation lock
screw (e.g.
the left one). Make sure to close this side! Switch to the next side (e.g. the right one). Hold the frame into position. Remove the transportation lock screw. Make sure to close this side!
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
80
Page 81
8. Installation of the displays
Step
15
Proceed until the transport screws of all front access mount modules are removed.
Then one by one open the front access mecha­nism in a controlled way: Simultaneously press the left and the right latch. Don't let the frame snap open! Guide it with both of your hands un­til it is completely swung out.
Step
16
Make sure that all front access mount modules are opened!
Step
17
Wear gloves!
Step
18
Take care! The monitors are very fragile. E.g. they break when a connector of a cable falls on­to them!
Unpack the displays.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
81
Page 82
8. Installation of the displays
Step
19
The back of the panel needs is provided with 4 mounting interfaces to allow connection to the front access mount.
Step
20
The interface is designed for the Z-
adjustment of
the displays consists out of two major building blocks:
The screw which is mounted to the panel and countered by a nut and washer, this is the fixed part.
The interface which is screwed on to the fixed part (screw).
Step
21
When the interface (screw) is aligned with the back­side of the panel it is in nominal position.
Before mounting the panel, make sure that the screw
is in nominal position!
Step
22
Adjustment is only working in one direction, re­sulting in an adjustment towards the front.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
82
Page 83
8. Installation of the displays
Step
23
To ease the adjustment process it is recom­mended to restrict the adjustment to the two lower interface poi
nts. This approach should give
sufficient margin to cover the typical Z­misalignments.
Please note: The adjustable interface cannot cover the imper-
fec
tions which are a direct consequence of a bad
setup in terms of levelling.
Step
24
When the dip switches are set correctly, hang in the monitors and when you are sure that the z adjustment interfaces are in nominal position, hang in the monitor.
The principle is simple and sophisticated: The four interface points of the monitor are just
fed into the respective slots of the interface frame.
Insert the "knobs" on top of the slots and move them down: the narrow end of the bottom slot together with gravity ensures that the monitors keep safely in place!
No need for any fixation or securing screws.
Step
25
Installation of the monitors is done from top to bottom, column wise.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
83
Page 84
8. Installation of the displays
Step
26
The height of the monitor can be adjusted by means of the adjustment screw.
This is an M6 screw: one full rotation equals 1mm.
In nominal position the screw does not touch the interface of the monitor.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
84
Page 85
8. Installation of the displays
Step
27
Also when the monitor is installed, the interface frame is NOT pushed back!
Step
28
Don't miss to plug in all cables.
On the rear of the front access mount module there is a small mirror.
Look at the mirror to see the interfaces and to conveniently plug in the cables.
On the rear of the monitor there is a row of switches. Press the bottom switch to switch on the monitor.
Step
29
Close the panels bottom up! You can push the panels horizontally to
close the
gap. Pushing can be done when the panels are open
or closed.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
85
Page 86
8. Installation of the displays
Step
30
Close one after the other and check adjacent panels with respect to their z alignment ("smooth surface").
If required, open the panel again and adjust it via the (bottom!) interface screws.
One turn of the interface screws equals 1.25 mm.
Close the panel and check the result. If required,
repeat the z alignment. Try to limit the adjustment to the bottom inter-
face points and align with the top of the previ­ous panel.
Step
31
Check the overall alignment of the wall!
Take the wall into operation.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
86
Page 87
8. Installation of the displays
8.1 Safety instruction on opening systems
When doing maintenance work or changing cables on a monitor built into a structure you have to open all monitors ABOVE the one you want to work on.
When a monitor which is built into a structure has to be de-mounted, first de-mount all monitors above the one you have to de-install and then close the interfaces: This gives you free access to the monitor you want to remove and eliminates the risk of damaging the monitor hanging above when moving the system up!
When opening a monitor which is built into a structure, simultaneously press on the left and right bottom sides of the monitors (there are the latches behind).
In case the interface frame does not open you very probably have a mixed situation of latches; one is opened, one closed. Then only press on the left OR on the right ot make the position of the latches the same.
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
87
Page 88
9. Distance to the wall
9 Distance to the wall
The video wall has to be fixed to the wall. In case of a linear setup, and in case the wall is in parallel to the video wall, every system has the same distance to the wall.
In case of curved setup, the distance to the wall increases with every system. The following drawing introduces the nomenclature:
do is the distance of the center module from the wall. α is the configuration angle, e.g. 3°, 5°, 8°.
n1 is the first module next to the center module
n2 is the seconded module next to the center module; and so on
d1 is the distance of the outer edge of n1 to the reference plane of n0.
d2 is the distance of the outer edge of n2 to the reference plane of n0; and so on.
The following table lists the distances of the outer edges to the reference plane of n0 depending on the configu­ration angle.
Configuration angle
Module # Distance to reference plane
1
d1=63.6mm
2
d2=190.64mm
3
d3=380.75mm
4
d4=633.43mm
5
d5=947.97mm
6
d6=1323.52mm
7
d7=1759.04mm
8
d8=2253.35mm
9
d9=2805.08mm
10
d10=3412.73mm
1
d1=105.92mm
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
88
Page 89
9. Distance to the wall
Configuration angle
Module # Distance to reference plane
2
d2=316.96mm
3
d3=631.5mm
4
d4=1047.15mm
5
d5=1560.76mm
6
d6=2168.41mm
7
d7=2865.48mm
8
d8=3646.66mm
9
d9=4506.01mm
10
d10=5436.98mm
1
d1=169.14mm
2
d2=504.12mm
3
d3=998.43mm
4
d4=1642.44mm
5
d5=2423.62mm
6
d6=3326.76mm
7
d7=4334.29mm
8
d8=5426.59mm
9
d9=6582.41mm
10
d10=7779.25mm
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
89
Page 90
10. Addresses
10 Addresses
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
90
Page 91
10. Addresses
10.1 Contact
Feel free to contact us if you have any further questions!
BARCO NV
President Kennedypark 35, 8500 Kortrijk (Belgium) RPR Kortrijk - BE0473191041
Visit Barco at http://www.barco.com
For Professional Support visit
http://www.barco.com/support
For Sales or other Contact information visit
http://www.barco.com/contact/regional-offices
Barco - LCD 5521 V4 - R591734 - Installation manual - Revision 00 - March-2017
_____________________________________________________________
91
Loading...