Barco JAO18, JAO15 User Manual

Page 1
JAO15 / JAO18
User Guide
Smart Terminal for the patient bedside
K5903250/01 10/03/2016
Page 2
Barco NV President Kennedypark 35, 8500 Kortrijk, Belgium Phone: +32 56.23.32.11 Fax: +32 56.26.22.62 Support: www.barco.com/en/support Visit us at the web: www.barco.com
PrintedinBelgium
Page 3
Table of contents
TABLE OF CONTENTS
1. Introduction ........................................... ............................................ 3
1.1 Key features .... ................ ................ ................ ................ ................ ............... 3
1.2 What’s in the box.............................................................................................. 3
1.3 Product overview.............................................................................................. 4
2. Installation ........ ................................................................... .............. 7
2.1 Power connection............................................................................................. 7
2.2 SSD/HDD replacement....................................................................................... 7
2.3 RAM module replacement ...................... ................ ................ .................. ........... 8
2.4 JAOHandset installation..... ................ .................. ................ ................ ............... 9
2.5 VESA mounting ...............................................................................................10
3. Operation ................ .................................................................... ...... 13
3.1 On/Off switching.................. ................ ................ ................ ................ .............13
3.2 Service call ....................................................................................................13
3.3 USB charging..................................................................................................14
3.4 HDMI input...................... ................ ................ ................ ................ ............... 14
4. Cleaning ................................. ........................................................... 15
4.1 Cleaning instructions .........................................................................................15
5. Important information ....................................... .................................... 17
5.1 Safety information...................... .................. ................ ................ ................ .....17
5.2 Environmental information ...................................................................................19
5.3 Regulatory compliance information ............ ................ ................ ................ .............20
5.3.1 USA information.........................................................................................20
5.3.2 Canada information ................ ................ ................ ................ ................ .....21
5.4 EMC notice ... ................ ................ ................ ................ ................ ................ .22
5.5 Explanation of symbols.......... ................ .................. ................ ................ ...........25
5.6 Legal disclaimer...............................................................................................28
5.7 Technical specications ......................................................................................28
K5903250 JAO15 / JAO18 10/03/2016
1
Page 4
Table of contents
2 K5903250 JAO15 / JAO18 10/03/2016
Page 5
1. Introduction
1. INTRODUCTION
1.1 Key features
Overview
JAO15 and JAO18 are designed to serve as a Point of Care (POC) and Point of Information terminals (POI) within healthcare applications. Manufactured using anti-bacterial plastics, the terminals provide a host of interactive healthcare applications providing secure access to Electronic Medical Records (EMR) and innovative triple-play solutions (web, IPTV, VoIP) for patient entertainment.
16:9 15.6” (JAO15) or 18.5” (JAO18) 1366x768 Fanless LED Panel Computer
Intel
Flat Panel by Resistive (JAO15) or PCAP (JAO18) Touch Screen
With 1x GbE/ HDMI input/ 5x USB ports
Built in speaker/ microphone/ 2x line out
13.56MHz RFID/ Smart card reader
DDR3L 2GB/ 2.5” 32GB SSD
System Power Input 19V DC
®
Celeron®J1900, Quad Core, Low Consumption CPU
1.2 What’s in the box
Overview
JAO15 or JAO18 terminal
Power supply
Power cords (EU and US type)
Set of mounting screws (only compatible with Barco mounting solutions)
Safety instructions sheet
K5903250 JAO15 / JAO18 10/03/2016
3
Page 6
1. Introduction
1.3 Product overview
Front
1
Image 1-1
2
3
4
1. Camera 720p camera with white LED
2. Barcode scanner (optional on JAO18, not supported on JAO15)
3. Multipurpose, congurable power key Please refer to the SDK documentation for more information about the different power key congura­tion options.
4. Combined SCR and RFID reader Combo Smart Carder Reader (SCR) + High-frequency (13.56MHz) RFID reader, with RFID contact­less tapping and card parking support.
Back
1
2
3
9
3
8
6
7
4
Image 1-2
4
5
4 K5903250 JAO15 / JAO18 10/03/2016
Page 7
1. Introduction
1. Microphone Built-in digital microphone
2. SSD/HDD service door Locked with Security Torx screws, used for SSD/HDD replacement.
3. JAOHandset side door (2x) To be removed to install the JAOHandset (optional).
4. Speaker (2x) Built in stereo speaker
5. Combined SCR and RFID reader Combo Smart Carder Reader (SCR) + High-frequency (13.56MHz) RFID reader, with RFID contact­less tapping and card parking support.
6. Bottom IO area
Image 1-3
- 2 x headset line out jack
- 2 x USB 2.0 connector (5V / 1.5A)
- HDMI input connector
7. Barcode scanner (optional on JAO18, not supported on JAO15)
8. Rear IO area
SC19V
Image 1-4
- Functional earth blind fastener
- 19V DC power supply input connector
- 6P6C RJ11 service call (SC) connector
- 3 x USB 2.0 connector
- RJ45 LAN Gigabit Ethernet connector
9. RAM and miniPCIe service door Locked with Security Torx screws, used for RAM replacement or installation of an extension module.
CAUTION: The service doors may only be opened by qualied service personnel, no
user serviceable parts inside.
WARNING: To prevent pos sible hearing damage, check the volume before using the
JAOHandset or headset line out and do not listen at high volume levels for long periods.
K5903250 JAO15 / JAO18 10/03/2016 5
Page 8
1. Introduction
6 K5903250 JAO15 / JAO18 10/03/2016
Page 9
2. Installation
2. INSTALLATION
2.1 Power connection
Overview
1. Connect the supplied external DC power supply to the +19 VDC power input of your JAO15 / JAO18.
2. Plug the other end of the external DC power supply into a grounded power outlet by means of the proper
power cord delivered in the packaging.
3. Optionally, earth the terminal by connecting the functional earth blind fastener to a grounded outlet by
means of a wire with at minimum AWG18 size (according to national Regulation requirements regarding maximum admitted cable length). Use an M3 screw to attach the wire to the functional earth blind fastener.
Image 2-1
WARNING: When you unplug the power cable, always pull the plug, never pull the cable.
Although the JAO15 and JAO18 have a very low standby power consumption, unplug the power cable to save e nergy if you do not use the terminal for a long period of time.
Connector type: 5.5 mm DC jack
2.2 SSD/HDD replacement
CAUTION: Prior to removing any service door, make sure the unit’s power is off and
disconnected from the power sources to prevent electric shock or system damage.
To fully disengage the power to the unit, please disconnect the power cord from the AC inlet.
To replace the SSD/HDD
1. Unscrew the Security Torx screws of the SSD/HDD service door, then remove the door.
K5903250 JAO15 / JAO18 10/03/2016
7
Page 10
2. Installation
Image 2-2
2. Remove the current SSD/HDD and replace it with a new one.
Image 2-3
3. Put the SSD/HDD service door back in place and x it with the Security Torx screws.
2.3 RAM mo du le replacement
CAUTION: Prior to removing any service door, make sure the unit’s power is off and
disconnected from the power sources t
To fully disengage the power to the unit, please disconnect the power cord from the AC inlet.
To replace the RAM module
1. Unscrew the Security Torx screws of the RAM service door, then remove the door.
o prevent electric shock or system damage.
Image 2-4
8 K5903250 JAO15 / JAO18 10/03/2016
Page 11
2. Remove the current DDR3L RAM module and replace it with a new one.
Image 2-5
3. Put the RAM service door back in place and x it with the Security Torx screws.
2.4 JAOHandset installation
2. Installation
CAUTION: Prior to removing any service door, make sure the unit’s power is off and
disconnected from the power sources to prevent electric shock or system damage.
To fully disengage the power to the unit, please disconnect the power cord from the AC inlet.
WARNING: To prevent possible hearing damage, check the volume
JAOHandset and do not listen at high volume levels for long periods.
before listening the
To switch the position of the JAOHandset (L/R)
The default mounting position of your JAOHandset is on the left hand side of your terminal. The procedure below describes how to prepare the JAOHandset for right hand side mounting.
1. Remove the 2 caps and the screws at the inside of the handset cradle.
2. Take apart the mounting bracket from the handset cradle and rotate the bracket 180°.
3. Reassemble the handset cradle with the 2 xation screws and reinsert the screw caps.
Image 2-6
The JAOHandset can now be attached to your terminal as described in the next procedure.
K5903250 JAO15 / JAO18 10/03/2016
9
Page 12
2. Installation
To install the JAOHandset
1. Remove the handset side door.
Image 2-7
2. Connect the handset connector to the cable available behind the side door. Please make sure to con-
nect the white dot to white dot pin.
Image 2-8
3. Use the screws from the handset box to rmly attach the handset to your terminal.
Image 2-9
2.5 VESA mounting
To mount the JAO15 / JA
Your JAO15 and JAO18 is compatible with the VESA 75 mm and VESA 100 mm standard, so it can be used on different VESA 75 and VESA 100 mounting solutions (arms, desk stands, ...).
O18 on a VESA solution
10
K5903250 JAO15 / JAO18 10/03/2016
Page 13
2. Installation
Image 2-10
The VESA mounting holes at the back of the terminal are provided with M4-type blind fasteners to xthe VESA mounting plate. Depending on the VESA plate thickness (T) and the thickness of possible washers (W), a different screw length (L) should be selected.
Please respect the following rule to select an appropriate screw length:
•L
min
•L
max
Image 2-11
=T+W+4mm
=T+W+5.5mm
T
W
L
min
Lmax
CAUTION: Use only a mounting solution that is in compliance with VESA requirements.
WARNING: The mounting screws included in the box of your JAO15 / JAO18 are only to
be used with Barco mounting s ol
K5903250 JAO15 / JAO18 10/03/2016 11
utions.
Page 14
2. Installation
12 K5903250 JAO15 / JAO18 10/03/2016
Page 15
3. Operation
3. OPERATION
3.1 On/Off switching
Overview
The way to switch your terminal on or off depends on the BIOS settings, congurable in the SDK. Please refer to the SDK documentation for more information about the different on/off switching conguration options.
3.2 Service call
Overview
The optional service call button and status LED of the JAOHandset are internally wired to the RJ11 Service Call connector which can be connected to the hospital’s internal network service call system.
The electrical signal of the service call button in the JAOHandset and the status LED of the JAOHandset can be detected/controlled on the RJ11 Service Call connector of your JAO15 / JAO18. Please refer to the connector pinout below for more details. The electrical signal requirements are available in the technical specication tables of this user guide (see "Technical specications", page 28).
WARNING: The RJ11 connector may not be connected to a telephony or telecom net-
work and is for use only with the hospital’s internal network service call system
The service call button is optional and not present on all JAOHandset models.
RJ11 Service Call connector pinout
Please use a 6P6C RJ11 connector with below pinout only.
Image 3-1
1. Not connected
2. Button +
3. Button -
4. LED +
5. LED -
6. Not connected
K5903250 JAO15 / JAO18 10/03/2016
13
Page 16
3. Operation
3.3 USB charging
Overview
The bottom USB ports on the JAO15 and JAO18 are capable of delivering 5V/1.5A output. This means you will be able to charge almost any smartphone, camera, ebook reader, etc. by plugging them into the terminal bottom USB ports.
USB charging is not possible via the USB ports at the back of your terminal.
3.4 HDMI input
Overview
The JAO15 and JAO18 are capable of playing High Denition video and audio of any HDMI compatible device (gaming console, DVD player, camera, etc.) that is connected to the HDMI input of your terminal.
For best signal quality transfer, use a High speed HDMI cable and do not use an HDMI cable longer than 5 m.
14 K5903250 JAO15 / JAO18 10/03/2016
Page 17
4. Cleaning
4. CLEANING
4.1 Cleaning instructions
To clean your JAO15 and JAO18
Clean the terminal using a sponge, cleaning cloth or soft tissue, lightly moistened with a recognized clean­ing product for medical equipment. Read and follow all label instructions on the cleaning product. In case of doubt about a certain cleaning product, use plain water.
Do not use following products:
Alcohol/solvents at higher concentration > 5%
Strong alkalis lye, strong solvents
•Acid
Detergents with uoride
Detergents with ammonia
Detergents with abrasives
Steel wool
Sponge with abrasives
Steel blades
Cloth with steel thread
CAUTION: Take care not to damage or scratch the front glass or LCD. Be careful with
rings or other jewelry and do not apply excessive pressure on the front glass or LCD.
CAUTION: Do not apply or spray liquid directly to the ter minal as excess liquid may
cause damage to internal electronics which may cause re or electrical shock. Instead, apply the liquid to a cleaning cloth.
In environments where specic chemicals or cleaning agents are used, please contact your local Barco ofce.
K5903250 JAO15 / JAO18 10/03/2016 15
Page 18
4. Cleaning
16 K5903250 JAO15 / JAO18 10/03/2016
Page 19
5. Important information
5. IMPORTANT INFORMATION
5.1 Safety information
General recommendations
Read the safety and operating instructions before operating the equipment.
Retain safety and operating instructions for future reference.
Adhere to all cautions, warnings and instructions on the equipment, safety instructions and user gu Detailed product information and the user guide are available for download from the Barco website. Please go to w
Electrical Shock or Fire Hazard
To prevent electric shock or re hazard, do not open the equipment or remove any covers.
No serviceable parts inside. Refer servicing to qualied personnel.
Do not expose this equipment to rain or moisture.
ww.barco.com.
ide.
Modications to the equipment
Do not modify this equipment without authorization of the manufacturer.
Service
If one of the following situations arises, ensure you get the equipment checked by service personnel:
The power cord or plug is damaged.
The equipment has been exposed to moisture.
The equipment is not functioning properly, or you cannot get it to work according to the user guide.
The equipment has been dropped and damaged.
The equipment has obvious signs of breakage.
Installation & mounting
When installing the equipment in a cupboard or another closed location, heed the necessary space between the set and the sides of the cupboard.
Place the equipment on a stable surface that can support the weight of at least 4 terminals or hang from a reliable structure during installation. Dropping the equipment is likely to cause serious injury to a child or adult, and serious damage to the equipment.
Improper installation of VESA mounting can result in serious personal injury! Use a VESA mounting solution that can support a weight of at least 10kg. VESA mount installation should be carried out by a professional technician. Please contact the service technician or your reseller if you need this service.
Type of protection ( electrical):
Equipment with external power supply: Class II equipment.
Degree of safety (ammable anesthetic mixture):
Equipment not suitable for use in the presence of a ammable anesthetic mixture with air or with oxygen or nitrous oxide.
Non-patient care equipment
This equipment is not intended to be used in life support systems, operating rooms or for diagnostic purposes.
The user is not supposed to touch SIP/SOPs and the patient at the same time.
K5903250 JAO15 / JAO18 10/03/2016
17
Page 20
5. Important information
Power connection – Equipment with external 19 VDC power supply
Power requirements: The equipment must be powered using the delivered medical approved 19 VDC (
) power supply. Model: DELTA MDS-090AAS19 B.
The medical approved DC (
1.5-0.75A 50-60Hz).
The power supply is specied as a part of the ME equipment or combination is specied as a ME system.
Make sure the voltage of the power source is correct before connecting the equipment to the power outlet.
The equipment should be installed near an easily accessible outlet.
The equipment is intended for continuous operation.
Transient over-voltage
If the equipment is not used for a long time, disconnect it from the AC inlet to avoid damage by transient over-voltage.
To fully disengage the power from the equipment, please disconnect the power cord from the AC inlet.
Power cords
Do not overload wall outlets and extension cords as this may result in re or electric shock.
Power cords should be routed so that they are not likely to be walked upon or pinched by items placed upon or against them, paying particular attention to cords at plugs and receptacles.
Use a power cord that matches the voltage of the power outlet, which has been approved and complies with the safety standard of your particular country.
) power supply must be powered by the AC mains voltage (100-240V~
Grounding
Optionally earth the equipment by connecting the functional earth blind fastener to a grounded outlet by means of a wire with at minimum AWG18 size (according to national Regulation requirements regarding maximum admitted cable length).
Water and moistu re
Keep this equipment away from excessive humidity.
Never use the equipment near water - e.g. near a bathtub, washbasi laundrytuborinawetbasement.
n, swimming pool, kitchen sink,
Cleaning
The equipment can be cleaned regularly according to usage. In e cals or cleaning agents are used, please contact your local Barco ofce.
Do not apply or spray liquid directly to the equipment as excess liquid may cause damage to internal electronics which may cause re or electrical shock. Instead, apply the liquid to a cleaning cloth.
nvironments where specicchemi-
External equipment
The RJ11 connector may not be connected to a telephony or telecom network and is for use only with the hospital’s internal network service call system.
If the equipment is equipped with a handset, the handset can magnetically retain small sharp objects (such as pins & paperclips) around the mouthcap or earcap region, please check and remove before use.
Accessory equipment connected to the analog and digital interfaces must be in compliance with the respective nationally harmonized IEC standards (i.e. IEC 60601 for data processing equipment). If in doubt, consult the technical services department or your local representative.
18
K5903250 JAO15 / JAO18 10/03/2016
Page 21
5. Important information
External connections to model JAO15 / JAO18 (I/O, LAN, etc) shall be in compliance with the require­ments for medical electrical systems as stated in chapter 16 of the standard for medical electrical equipment IEC 60601-1.
Batteries
If your equipment is losing time or the BIOS conguration resets to default settings, the battery most likely has no power.
Do not replace the battery yourself. Please contact a qualied technician or your supplier of the JAO15 / JAO18. There is a danger of leakage or explosion if the battery is incorrectly replaced. The JAO15 / JAO18 is provided with a battery-powered real-time clock circuit.
Laser radiation
WARNING: Use of controls or adjustments or performance of proced
those specied herein may result in hazardous radiation exposure.
ures other than
Recycling
For more information about recycling of this equipment, please contact your local city ofce, your municipal waste disposal service or the shop where you purchased the equipment.
Storage
Do not leave this equipment in an uncontrolled environment where the storage temperature is below -20 °C or above 60°C. This may damage the equipment.
This apparatus conforms to
JAO15 / JAO18 (without JAOHandset)
- ANSI/AAMI ES 60601-1
- CAN/CSA-C22.2 No.60601-1
-FCCclassB
- CAN ICES-3 (B)/NMB-3(B)
-CE
JAO15 / JAO18 (with JAOHandset)
- IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013
- EN 60950-1:2006 /A11:2009/A1:2010/ A12:2011/ A2:2013 and AS/NZS 60950.1:2015
-FCCclassB
- CAN ICES-3 (B)/NMB-3(B)
-CE
5.2 Environmental information
Disposal Information
Waste Electrical and Electronic Equipment
K5903250 JAO15 / JAO18 10/03/2016
19
Page 22
5. Important information
This symbol on the product indicates that, under the European Directive 2012/19/EU governing waste from electrical and electronic equipment, this product must not be disposed of with other municipal waste. Please dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources.
For more information about recycling of this product, please contact your local city ofce or your municipal waste disposal service.
For details, please visit the Barco website at: h
ttp://www.barco.com/en/AboutBarco/weee
Disposal of batteries in the product
This product contains batteries covered by the Directive 2006/66/EC which must be collected and
disposed of separately from municipal waste. If the battery contains more than the specied values of lead (Pb), mercury (Hg) or cadmium (Cd), these
chemical symbols will appear below the crossed-out wheeled bin symbol. By participating in separate collection of batteries, you will help to ensure proper disposal and to prevent
potential negative effects on the environment and human health.
Turkey RoHS compliance
Türkiye Cumhuriyeti: AEEE Yönetmeliğine Uygundur.
[Republic of Turkey: In conformity with the WEEE Regulation]
5.3 Regulatory compliance information
5.3.1 USA information
Indications for use
The JAO15 and JAO18 are intended to be used at the patient bedside, for the purpose of patient enter­tainment, patient information, patient communication (phone and video phone), patient administration and service calls.
The JAO15 and JAO18 additionally allo users.
The JAO15 and JAO18 is not intended to be used in patient monitoring, diagnosis, treatment, alleviation or prevention of diseases, injuries and handicaps.
w for remote access to hospital systems by trained professional
RF exposure warning
This equipment must be installed and operated in accordance with provided instructions and the an­tenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co­mitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.
20
located or operating in conjunction with any other antenna or trans-
K5903250 JAO15 / JAO18 10/03/2016
Page 23
5. Important information
FCC class B
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference re­ceived, including interference that may cause undesired operation.
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interfe to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the device and receiver.
Connect the device into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help. Changes or modications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
rence
5.3.2 Canada information
Industry Canada (IC) notices
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, an interference, including interference that may cause undesired operation of the device.
This Class B digital apparatus complies with Canadian ICES-003. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna
or transmitter, except tested built-in radios. The County Code Selection feature is disabled for products marketed in the US/ Canada.
d (2) this device must accept any
Avis d’lndustry Canada (IC)
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Cet appareil et son antenne ne doivent pas être situés ou fonctionner en conjonction avec une autre
antenne ou un autre émetteur, exception faites des radios intégrées qui ont été testées. La fonction de sélection de l’indicatif du pays est désactivée pour les produits commercialisés aux États-
Unis et au Canada.
Radiation exposure statement
This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated wi body.
th minimum distance 20cm between the radiator & your
Déclaration d’exposition aux radiations
Cet équipement est conforme aux limites d’exposition aux rayonnements IC établies pour un environ­nement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.
K5903250 JAO15 / JAO18 10/03/2016
21
Page 24
5. Important information
5.4 EMC notice
When the JAO15 / JAO18 is used in combination with external peripherals, including the JAOHandset, the test levels which are listed further below are not applicable and the EN55022 (CISPR22) and EN55024 (CISPR24) test levels apply instead.
General information
No specic requirement on the use of external cables or other accessories except power supply. With the installation of the device, use only the delivered power supply or a spare part provided by the
legal manufacturer. Using another can result in a decrease of the immunity level of the device.
Electromagnetic emissions
The JAO15 / JAO18 is intended for use in the electromagnetic environment specied below. The customer or the user of the JAO15 / JAO18 should assure that it is used in such an environment.
Emissions test
RF emissions CISPR 11
RF emissions CISPR 11
Harmonic emissions IEC 61000-3-2
Voltage uctuations/ icker emissions
IEC 61000-3-3
This JAO15 / JAO18 complies with appropriate medical EMC standards on emissions to, and interference from surrounding equipment. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interfer­ence that may cause undesired operation.
Interference can be determined by turning the equipment off and on. If this equipment does cause harmful interference to, or suffer from harmful interference of, surrounding
equipment, the user is encouraged to try to correct the interference by one or more of the following mea­sures:
Compliance
Group 1 The JAO15 / JAO18 uses RF
Class B
Class D
Complies
Electromagnetic environment – Guidance
energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. The JAO15 / JAO18 is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.
Reorient or relocate the receiving antenna or equipment.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced technician for help.
Electromagnetic immunity
The JAO15 / JAO18 is intended for use in the electromagnetic environment specied below. The customer or the user of the JAO15 / JAO18 should assure that it is used in such an environment.
22
K5903250 JAO15 / JAO18 10/03/2016
Page 25
5. Important information
Immunity test
Electrostatic discharge (ESD)
IEC 61000-4-2
Electrical fast transient/burst
IEC 61000-4-4
Surge IEC61000-4-5
Voltage dips, short interruptions and voltage variations on power supply input lines
IEC 61000-4-11
Power frequency (50/60 Hz) magnetic eld
IEC 61000-4-8
Conducted RF IEC 61000-4-6 Radiated RF IEC 61000-4-3
IEC 60601
Test levels
± 6kV contact ±8kVair
± 2kV for power supply lines
± 1kV for input/ output lines
± 1 kV line(s) to line(s) ± 2 kV line(s) to earth
<5%U U
T
40% U
1
(> 95% dip in
T
) for 0.5 cycle
(60%dipinUT)
T
for 5 cycles 70% U
(30%dipinUT)
T
for 25 cycles <5%U
U
) for 5s
T
(>95% dip in
T
3A/m
3Vrms 150 kHz to 80 MHz 3V/m 80 MHz to 2.5 GHz
Compliance level
± 6kV contact ±8kVair
± 2kV for power supply lines
± 1kV for input/ output lines
± 1 kV line(s) to line(s) ±2kVline(s)toearth
<5%U U
) for 0.5 cycle
T
40% U
(> 95% dip in
T
(60% dip in UT)
T
for 5 cycles 70% U
(30% dip in UT)
T
for 25 cycles <5%U
U
)for5s
T
Not applicable
(>95% dip in
T
2
3V
3V/m
Electromagnetic environment – guidance
Floors should be wood, concrete or ceramic tile. If oors are covered with synthetic material, the relative humidity should be at least 30%
Mains power quality should be that of a typical commercial or hospital environment
Mains power quality should be that of a typical commercial or hospital environment
Mains power quality should by that of a typical commercial or hospital environment. If the user of the JAO15 / JAO18 requires continued operation during power mains interruptions, it is recommended that the JAO15 / JAO18 be powered from an uninterruptible power supply or a battery. Power frequency magnetic elds should be at levels characteristic of a typical location in a typical commercial or hospital environment. Portable and mobile RF communications equipment should be used no closer to any part of the JAO15 / JAO18, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance
d=1.2√P d=1.2√P 80 MHz to 800
MHz d=2.3P 800 MHz to 2.5
Ghz
1. is the a.c. mains voltage prior to application of the test level.
2. JAO15 / JAO18 doesn’t contain susceptible components to magnetic fields
K5903250 JAO15 / JAO18 10/03/2016 23
Page 26
5. Important information
Immunity test
IEC 60601
Test levels
Compliance level
Electromagnetic environment – guidance
Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m).
Field strengths from xed RF transmitters, as determined by an electromagnetic site survey,
3
should be less than the compliance level in each frequency
4
range. Interference may occur in
the vicinity of equipment marked with symbol:
At 80 MHz and 800 MHz, the higher frequency range applies.
These guidelines may not apply in all situations. Electromagnetic propagation is af­fected by absorption and ree ction from structures, obje cts and people.
Recommended separation distance
The JAO15 / JAO18 is intended for use in an electromagnetic environment in which radiated RF distur­bances are controlled. The customer of the user of the JAO15 / JAO18 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equip­ment (transmitters) and the JAO15 / JAO18 as recommended below, according to the maximum output power of the communications equipment.
3. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the JAO15 / JAO18 is used exceeds the applicable RF compliance level above, the JAO15 / JAO18 should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the JAO15 / JAO18.
4. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than3V/m.
24 K5903250 JAO15 / JAO18 10/03/2016
Page 27
5. Important information
Rated maximum output power of transmitter
W
0.01 0.12 0.12 0.23
0.1 0.38 0.38 0.73 1 1.2 1.2 2.3 10 3.8 3.8 7.3 100121223
At 80 MHz and 800 MHz, the s eparation distance for the higher frequency range applies.
These guidelines may not apply in all situations. Electromagnetic propagation is af­fected by absorption and reection form structures, object and people.
Separation distance according to frequency of transmitter
5
150kHz to 80MHz d=1.2√P
80MHz to 800MHz d=1.2√P
800MHz to 2.5GHz d=2.3√P
5.5 Exp lanation of symbols
Symbols on the device
On the device or power supply, you may nd the following symbols (nonrestrictive list):
Indicates the device meets the requirements of the applicable EC directives.
Indicates compliance with Part 15 of the FCC rules (Cla
Indicates the device is approved according to the UL R
Indicates the device is approved according to the UL regulations for Canada and US
Indicates the device is approved according to the UL Demko regulations
Indicates the device is approved according to the CCC regulations
ss A or Class B)
ecognition regulations
Indicates the device is approved according to the VCCI regulations
5. For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter. Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
K5903250 JAO15 / JAO18 10/03/2016 25
Page 28
5. Important information
Indicates the device is approved according to the KC regulations
Indicates the device is approved according to the BSMI regulations
Indicates the device is approved according to the PSE regulations
Indicates the USB connectors on the device
Indicates the DisplayPort connectors on the device
Indicates the legal manufacturer
Indicates the manufacturing date
Indicates the temperature limitations6for the device to safely operate within specs.
Indicates the device serial number
Indicates the device part number or catalogue number
Warning: dangerous voltage
Caution
Consult the operating instructions
Indicates this device must not be thrown in the trash but must be recycled, according to the Eur directive
6. Values for xx and yy can be found in the technical specifications paragraph.
26 K5903250 JAO15 / JAO18 10/03/2016
opean WEEE (Waste Electrical and Electronic Equipment)
Page 29
SC
5. Important information
Indicates Direct Current (DC)
Indicates Alternating Current (AC)
Stand-by
Equipotentiality
Functional earth (ground)
Indicates the position of the RFID and smart card reader.
Indicates the position of the Service Call connector.
Indicates the position of the headset line out jack(s).
Indicates the position of the LAN Gigabit Ethernet connector.
Symbols on the box
On the box of the device, you may nd the following symbols (nonrestrictive list):
Indicates a device that can be broken or damaged if not handled carefully when being stored.
Indicates a device that needs to be protected from moisture when being stored.
Indicates the storage direction of the box. The box must be transported, handled and stored in such a way that the arrows always point upwards.
15
n
20 - 30 Kg
n
or
Indicates the maximum number of identical boxes which may be stacked on each other, where “n” is the limiting number.
Indicates that the box should be carried with two persons.
Indicates that the box should not be cut with a knife, a cutter or any other sharp object.
yy
xx
-20 °C
+60 °C
being stored.
K5903250 JAO15 / JAO18 10/03/2016 27
Indicates the temperature limits7to which the device can be safely exposed when
Page 30
5. Important information
yy
85 %
Indicates the range7of humidity to which the device can be safely exposed when being stored.
x
5 %
yyy
106 kPa
Indicates the range7of atmospheric pressure to which the device can be safely exposed when being stored.
xx
50 kPa
5.6 Legal disclaimer
Disclaimer notice
Although every attempt has been made to achieve technical accuracy in this document, we assume no responsibility for errors that may be found. Our goal is to provide you with the most accurate and usable documentation possible; if you discover errors, please let us know.
Barco software products are the property of Barco. They are distributed under copyright by Barco NV or Barco Inc., for use only under the specic terms of a software licen Barco Inc. and the licensee. No other use, duplication, or disclosure of a Barco software product, in any form, is authorized.
The specications of Barco products are subject to change without notice.
se agreement between Barco NV or
Trademarks
All trademarks and registered trademarks are property of their respective owners.
Copyright notice
This document is copyrighted. All rights are reserved. Neither this document, nor any part of it, may be reproduced or copied in any form or by any means - graphical, electronic, or mechanical including photocopying, taping or information storage and retrieval systems - without written permission of Barco.
© 2016 Barco NV all rights reserved.
5.7 Technical specications
JAO15
Service call Optional, on JAOHandset
Handset
USB TV tuner module ATSC or DVB TV tuner USB dongle (for installation in the wallbox)
Bluetooth
JAOHandset with phone, hook switch and key membrane and optional remote control buttons, Service call function, 2D barcode scanner
(Comes with cradle, left or right side mounting) Optional, external accessory
Optional, external accessory Combo WiFi 802.11b/g/n + Bluetooth Mini PCIe module Optionally available from Custom Conguration Program, integrated
WiFi
Combo WiFi 802.11b/g/n + Bluetooth Mini PCIe module Optionally available from Custom Conguration Program, integrated
7. Values for xx and yy can be found in the technical specifications paragraph.
28 K5903250 JAO15 / JAO18 10/03/2016
Page 31
5. Important information
Barcode scanner
Combined SCR and RFID reader
Display 15.6" WXGA (1366 x 768), Wide-screen (aspect ratio 16:9)
Warranty 24-months standard warranty
Power
Dimensions 418 x 270 x 50 mm
Color Barco White cover, Black bezel front glass Certications CE, FCC class B, EN 60601-1, UL 60601-1, IEC60950-1 CB
Weight 4.2 kg Audio Integrated stereo speakers, 2 x 2 Watt, down-ring
N/A Combo Smart Carder Reader (SCR) + High-frequency RFID reader,
with RFID contactless tapping and card parking support Standard, integrated
Large viewing angle (160°/160° hor/ver typ) Long lifetime (50,000 hrs MTBF)
Up to 5-years extended warranty contracts available 19V DC input, 4.74A current rating, medical wide AC-input power
supply EU + US power cord standard
VESA mount, 75x75 and 100x100 compatible
ANSI/AAMI ES60601-1, CAN/CSA-C22.2 No.60601-1
Internal digital microphone
Backlight
CPU Intel® Celeron® Processor J1900 System-on-Chip (SoC)
Medical environment considerations
BIOS AMI BIOS, 8M-bit SPI ROM
Storage capacity 2.5" Storage bay
Graphics chip set Integrated Intel® HD Graphics (Gen7)
Operating system Linux: Ubuntu 14.04.1 LTS and equivalent
LED, High luminance (300 cd/m2 typ) Backlight brightness (+ on/off) controllable by software (GPIO)
2.0 GHz Quad-core with Burst up to 2.42 GHz Antibacterial material (plastic housing) Fanless design with passive cooling concept, no vents, no moving parts IP65 front face
DMI information with unique identier information
Standard 32 GB SSD installed
Hardware-accelerated video decoding support with Intel® Quick Sync Video
Windows®: 7, 8 & 10
K5903250 JAO15 / JAO18 10/03/2016 29
Page 32
5. Important information
Connectivity Gigabit Ethernet LAN, RJ45 (x1, on rear)
USB 2.0 (x2 on bottom, x3 on rear) Headphone connector, 3.5mm mini jack (x2) Handset connector (x2, internal left or right), compatible with optional
JAOHandset HDMI input (x1, on bottom), 720p HD Ready resolution Use as stand-alone screen to connect external source such as a
gaming console Service Call connector for use with SC button on optional JAOHandset,
RJ11 (x1, on rear) - Input rating: +12V to +48V @ max. 20mA Programmable GPIO (for Backlight control, Multipurpose buttons on
the front, Audio, …)
User interface Single-touch screen, 5-wire resistive touch technology
Note: Capacitive multi-touch optional, available from OEM program
Multi-purpose capacitive touch keys in glass front-bezel Standard On/Off switch, extra buttons available from Custom
Conguration Program
Webcam System memory 1 slot DDR3L 1333 SO-DIMM socket, Support up to 8GB capacity
Integrated HD Camera (720p), with privacy LED indicator
Standard 2 GB installed
Storage pressure 50kPato106kPA Operating temperature 0°Cto40°C Storage temperature -20°C to 60°C Operating humidity 20% to 80% (non-condensing) Storage humidity 20% to 80% (non-condensing)
Operating pressure Operating altitude Up to 3000m
50kPato106kPA
JAO18
Service call Optional, on JAOHandset Handset JAOHandset with phone, hook switch and key membrane and optional
remote control buttons, Service call function, 2D barcode scanner (Comes with cradle, left or right side mounting) Optional, external accessory
USB TV tuner module ATSC or DVB TV tuner USB dongle (for installation in the wallbox)
Optional, external accessory
Bluetooth
WiFi
Combo WiFi 802.11b/g/n + Bluetooth Mini PCIe module Optionally available from Custom Conguration Program, inte Combo WiFi 802.11b/g/n + Bluetooth Mini PCIe module
grated
Optionally available from Custom Conguration Program, integrated
Barcode scanner 2D Barcode scanner
Optionally available from Custom Conguration Program, integr
30 K5903250 JAO15 / JAO18 10/03/2016
ated
Page 33
5. Important information
Combined SCR and RFID reader
Display
Warranty 24-months standard warranty
Power
Dimensions 482 x 309 x 48 mm
Color Barco White cover, Black bezel front glass Certications CE, FCC class B, EN 60601-1, UL 60601-1, IEC60950-1 CB
Weight 4.8 kg
Audio
Combo Smart Carder Reader (SCR) + High-frequency RFID reader, with RFID contactless tapping and card parking support
Standard, integrated
18.5" WXGA (1366 x 768), Wide-screen (aspect ratio 16:9) Large viewing angle (170°/160° hor/ver typical) Long life-time (50,000 hrs MTBF)
Up to 5-years extended warranty contracts available 19V DC input, 4.74A current rating, medical wide AC-input power
supply EU + US power cord standard
VESA mount, 75x75 and 100x100 compatible
ANSI/AAMI ES60601-1, CAN/CSA-C22.2 No.60601-1
Integrated stereo speakers, 2 x 2 Watt, down-ring Internal digital microphone
Backlight
CPU Intel® Celeron® Processor J1900 System-on-Chip (SoC)
Medical environment considerations
BIOS AMI BIOS, 8M-bit SPI ROM
Storage capacity 2.5" Storage bay
Graphics chip set Integrated Intel® HD Graphics (Gen7)
Operating system Linux: Ubuntu 14.04.1 LTS and equivalent
LED, High luminance (300 cd/m2 typical) Backlight brightness (+ on/off) controllable by software (GPIO)
2.0 GHz Quad-core with Burst up to 2.42 GHz Antibacterial material (plastic housing) Fanless design with passive cooling concept, no vents, no moving parts IP65 front face
DMI information with unique identier information
Standard 32 GB SSD installed
Hardware-accelerated video decoding support with Intel® Quick Sync Video
Windows®: 7, 8 & 10
K5903250 JAO15 / JAO18 10/03/2016 31
Page 34
5. Important information
Connectivity Gigabit Ethernet LAN, RJ45 (x1, on rear)
USB 2.0 (x2 on bottom, x3 on rear) Headphone connector, 3.5mm mini jack (x2) Handset connector (x2, internal left or right), compatible with optional
JAOHandset HDMI input (x1, on bottom), 720p HD Ready resolution Use as stand-alone screen to connect external source such as a
gaming console Service Call connector for use with SC button on optional JAOHandset,
RJ11 (x1, on rear) - Input rating: +12V to +48V @ max. 20mA Programmable GPIO (for Backlight control, Multipurpose buttons on
the front, Audio, …)
User interface Capacitive 10-point Multi-touch screen, P-CAP touch technology
Note: Resistive single-touch optional, available from OEM program
Multi-purpose capacitive touch keys in glass front-bezel Standard On/Off switch, extra buttons available from Custom
Conguration Program
Webcam System memory 1 slot DDR3L 1333 SO-DIMM socket, Support up to 8GB capacity
Integrated HD Camera (720p), with privacy LED indicator
Standard 2 GB installed
Storage pressure 50kPato106kPA Operating temperature 0°Cto40°C Storage temperature -20°C to 60°C Operating humidity 20% to 80% (non-condensing) Storage humidity 20% to 80% (non-condensing)
Operating pressure Operating altitude Up to 3000m
50kPato106kPA
32 K5903250 JAO15 / JAO18 10/03/2016
Page 35
Dimension drawing JAO15
5. Important information
267.0 ± 0.1 mm
269.7 ± 0.1 mm
Image 5-1
418.0 ± 0.1 mm
59.2 ± 0.1 mm294.7 ± 0.1 mm 64.1 ± 0.1 mm
50.0 ± 0.1 mm
32.1 ± 0.1 mm
Dimension drawing JAO18
302.0 ± 0.1 mm
308.2 ± 0.1 mm
66.0 ± 0.1 mm 62.5 ± 0.1 mm165.7 ± 0.1 mm 99.6 ± 0.1 mm87.8 ± 0.1 mm
Image 5-2
482.0 ± 0.1 mm
48.0 ± 0.1 mm
32.1 ± 0.1 mm
K5903250 JAO15 / JAO18 10/03/2016 33
Loading...