Thank you for choosing this CORONIS FUSION 10MP display!
Equipped with proprietary 'SmoothGray' technology for a meticulously
rendered grayscale curve, the C
details and lesions more noticeable than ever before. Add to this
exceptionally high brightness and contrast levels, truly dark blacks and
perfect geometry and you begin to understand that supreme grayscale
precision has a new meaning.
Thanks to the seamless 30-inch LCD screen, you can easily compare prior
and current mammography images without the annoyance of a central
bezel. Moreover, it allows you to review X-ray chest images or 40 fullresolution CT or MR images with superb diagnostic precision on a single
screen.
The integrated I-Guard sensor makes Quality Assurance an easy job.
Combined with the online MediCal QAWeb solution, I–Guard performs
intervention-free DICOM calibrations, Quality Assurance tests and remote
assessment of your display.
ORONIS FUSION 10MP display makes subtle
Use the instructions in this guide to install your C
ORONIS FUSION 10MP
display and discover all these interesting features yourself!
Following symbols may be used throughout this guide:
Warning: Risk of
WARNING
injury to human
beings
Important notice
Caution: Risk of
damage to the
product
Note
or remark
Hint, tipAdditional
information
Read all the safety information starting on page 47 before
operating your C
ORONIS FUSION 10MP display.
Coronis Fusion 10MP3
(This page intentionally left blank.)
4Coronis Fusion 10MP
Table of contents
What's in the box.............................................................7
Parts, controls and connectors ........................................9
Front view ............................................................................................... 9
Open source license information ........................................................ 62
6Coronis Fusion 10MP
What's in the box
Your CORONIS FUSION 10MP display comes with:
• this C
• a system CD
• two DVI cables
• two DisplayPort cables
• a USB cable
• a set of AC power cords
• an external power supply
If you ordered a Barco display controller, it’s also in the box together
with its accessories and dedicated user guide.
ORONIS FUSION 10MP display guide
Keep your original packaging. It is designed for this display and
is the ideal protection during transport.
Coronis Fusion 10MP7
(This page intentionally left blank.)
8Coronis Fusion 10MP
Parts, controls and connectors
Front view
182 3 4576
12
USB downstream connectorsLeft/Up key
34
Right/Down keyMenu/Enter key
56
Stand-by/Cancel keyAmbient light sensor
7
Power status indicator lightControl wheel
8
Coronis Fusion 10MP9
Rear view
1 2345
12
USB downstream connectorUSB upstream connector
34
Ethernet connector (see note
below)
56
DisplayPort 1 video inputConnector compartment
78
Neck coverDisplay stand cover
9
DisplayPort 2 video inputDVI 2 video input
1112
+5 VDC, 0.5 A power output+24 VDC power input
The Ethernet connection is used for maintenance purposes and
is not supported for user application.
687
DVI 1 video input
cover
10
91011 12
10Coronis Fusion 10MP
Display installation
Prior to installing your CORONIS FUSION 10MP display and
connecting all necessary cables, make sure to have a suitable
display controller physically installed in your computer. If you are
using a Barco display controller, please consult the user guide
delivered with it to do this.
Removing the covers
CONNECTORCOMPARTMENTCOVER
The connector compartment cover should be removed to get access to
the connectors. To remove the cover, proceed as follows:
1 Gently lift the clips at one of the handles of the connector
compartment cover to release that side of the cover.
2 Do the same at the other side of the cover.
3 Remove the cover.
Coronis Fusion 10MP11
DISPLAYSTANDCOVER
To get access to the cable routing channel, the display stand cover
should be removed. This can be done as follows:
1 Gently press and hold the clips at the inside top of the cover.
2 Slide the cover upwards while holding the clips pressed.
12Coronis Fusion 10MP
Unlocking the height mechanism
In the factory, the height-positioning system in the display stand is
locked with a red hook to prevent damage during transportation. You’ll
have to remove this hook before adjusting your display height position.
1 While holding the display panel pushed down, pull out the red
hook in the display stand.
To retain the hook for possible future transportation, insert the
short, red end of the hook back into the stand of your display.
Coronis Fusion 10MP13
Adjusting the display position
Now that the height-positioning system of your display is unlocked, you
can tilt, swivel, raise and lower the display as desired.
Do not try to pivot your display when attached to the stand.
Trying to do so could cause serious damage to your display and
its stand.
14Coronis Fusion 10MP
Connecting the signal cables
1 Connect one head of the display controller to the DVI 1 or
DisplayPort 1 connector with one of the supplied DVI or DisplayPort
cables.
2 Connect another head of the display controller to the DVI 2 or
DisplayPort 2 connector with one of the supplied DVI or DisplayPort
cables.
Each side of your display can have a different video input
connected (one side can have DVI connected while the
other side has DisplayPort connected). Both display sides
can have the same video input connected as well but
only one video input is allowed on each side of your
display.
3 If you want to make use of your display’s USB downstream
connectors, connect a PC USB downstream connector to the
display’s USB upstream connector by means of the supplied USB
2.0 cable.
Coronis Fusion 10MP15
Connecting the power cables
1 Connect the supplied external DC power supply to the +24 VDC
power input of your C
2 Plug the other end of the external DC power supply into a
grounded power outlet by means of the proper power cord
delivered in the packaging.
ORONIS FUSION 10MP display.
Routing the cables
Route all connected cables trough the cable routing channel in the stand
of your display.
The cable straps at the inside of the connector compartment
allow you to fix the cables for better shielding of the cables.
16Coronis Fusion 10MP
Re-attaching the covers
1 Re-attach the display stand cover by sliding it downward. You’ll
hear a “click” sound of the cover’s clips when the display stand
cover is in position.
Pay attention that all cables stay in the cable channel
while replacing the cover.
2 Re-attach the connector compartment cover by sliding the cover’s
top in position and then push the cover’s bottom. You’ll hear a
“click” sound of the cover’s clips when the connector compartment
cover is in position.
Coronis Fusion 10MP17
VESA-mount installation
The panel, standard attached to a stand, is compatible with the VESA
100 mm standard. Thus, it can be used with an arm that is approved by
VESA. This chapter shows you how to release the panel from the stand
and how to attach it to an arm. If you’re not using an arm, you can skip
this chapter.
1 Gently pull open both lower sides of the cover.
2 Slide the cover upwards while holding the lower sides pulled open.
18Coronis Fusion 10MP
3 Lift the plastic frame that covers the fixation of the panel to the
stand. Turn it for 45 degrees to uncover the fixation screws.
4 Unscrew the four fixation screws fixing the panel to the stand.
5 Attach the panel firmly to the arm using 4 screws M4 x 10 mm.
You should mount the panel in landscape position. Portrait position
is not supported.
Use an arm that can support a weight of at least 18 kg
(39.68 lbs). Failure to do so could make the panel fall,
causing serious injury to a child or adult, and serious
damage to the equipment.
Coronis Fusion 10MP19
First time starting up
You are now ready to start up your CORONIS FUSION 10MP display system
for the first time.
1 Switch on your C
“Stand-by switching” on page 24.
2 Turn on the computer connected to your display.
If you have properly installed your display and display controller, the
Windows start-up messages will appear once the boot procedure is
finished.
Your CORONIS FUSION 10MP display will be running in a basic
video mode at a default refresh rate when first time starting
up.
If you are using a Barco display controller, please consult the
user guide delivered with it to install the drivers, software and
documentation. When this is done, your display will
automatically detect the connected video input signal(s) and
apply the correct video mode and refresh rate.
ORONIS FUSION 10MP display as described in
20Coronis Fusion 10MP
Daily operation
Recommendations for daily operation
OPTIMIZETHELIFETIMEOFYOURDISPLAY
Enabling the Display Power Management System (DPMS) of your display
will optimize its diagnostic lifetime by automatically switching off the
backlight when the display is not used for a specified period of time. By
default, DPMS is enabled on your display, but it also needs to be
activated on your workstation. To do this, go to “Power Options
Properties” in the “Control Panel”.
Barco recommends setting DPMS activation after 20 minutes of
non-usage.
USEASCREENSAVERTOAVOIDIMAGERETENTION
Prolonged operation of an LCD with the same content on the same
screen area may result in a form of image retention.
You can avoid or significantly reduce the occurrence of this phenomenon
by using a screen saver. You can activate a screen saver in the “Display
properties” window of your workstation.
Barco recommends setting screen saver activation after 5
minutes of non-usage. A good screen saver displays moving
content.
In case you are working with the same image or an application with
static image elements for several hours continuously (so that the screen
saver is not activated), change the image content regularly to avoid
image retention of the static elements.
UNDERSTANDPIXELTECHNOLOGY
LCD displays use technology based on pixels. As a normal tolerance in
the manufacturing of the LCD, a limited number of these pixels may
remain either dark or permanently lit, without affecting the diagnostic
Coronis Fusion 10MP21
performance of the product. To ensure optimal product quality, Barco
applies strict selection criteria for its LCD panels.
To learn more about LCD technology and missing pixels, consult
the dedicated white papers available at www.barco.com/
medical.
ENHANCEUSERCOMFORT
Every Barco multi-head display system is color matched with the highest
specification in the market.
Barco recommends keeping color-matched displays together.
Furthermore, it is important to use all displays of a multi-head
configuration at the same rate to preserve color matching
throughout the economic lifetime of the system.
MAXIMIZEQUALITYASSURANCE
The ‘MediCal QAWeb’ system offers online service for high-grade Quality
Assurance, providing maximum diagnostic confidence and uptime.
Learn more and sign up for the free MediCal QAWeb Essential
level at www.barco.com/medical/qa
22Coronis Fusion 10MP
Keys indicator lights
By default, the keys indicator lights will be dimmed which makes them
unavailable at that moment.
TOMAKETHEKEYSLIGHTUP:
1 Gently sweep your finger over the bottom right hand side of your
display.
As a result, the keys will light up and are now available for further
actions. However, if no further actions are taken within the following 5
seconds, the keys indicator lights will dim again.
The keys indicator lights auto-dim function can be disabled in
the OSD menu. Please refer to “Keys indicator lights” on
page 29 for detailed instructions on how to do this.
Coronis Fusion 10MP23
Stand-by switching
Switching on the display while it is in stand-by mode or vice versa can
both be done by using the keys or by using the control wheel.
TOSWITCHYOURDISPLAYON/STAND-BYUSINGTHEKEYS:
1 Light up the keys indicator lights as previously described.
2 While the keys are light up, touch the Stand-by/Cancel key for
1 Press and hold the control wheel for approximately 2 seconds.
As a result, the display will switch on or will switch to stand-by mode.
When the display is switched on, the power status indicator light is
dimmed. When the display is in stand-by mode, the power status
indicator light is orange.
The power status indicator light can be enabled in the OSD
menu so that it will turn blue when the display is switched on. Please refer to “Power status indicator light” on page 28
for detailed instructions on how to do this.
In case of a power outage recovery, your display will always
start-up in the power mode it was in before the power
interruption (i.e. stand-by or on). This protects your display