BAPI CO2 Room Sensor Part Numbering Designation

List Your
Price Order
Ordering Information BAPI-Stat 3 Style Room CO2 Sensor with Optional Temperature and Humidity Sensing
BA/
Temperature Display Mode
Temperatures Displayed in °F (Temperature is displayed by default but can be turned off by the user. See instruction sheet.)
$35.00
$_______
BS3C
Temperatures Displayed in °C (Temperature is displayed by default but can be turned off by the user. See instruction sheet.)
$35.00
$_______
BS3X No LCD Display $0.00
CO Output
$475.00
$_______
CO as 0 to 2,000 PPM, 0 to 10 VDC output, Single Beam Automatic Background Calibration unit for periodically unoccupied areas
$475.00
$_______
CO as 0 to 2,000 PPM, 0 to 5 VDC output, Dual Channel Calibration "24/7" unit for continuously occupied areas
$505.00
$_______
$505.00
$_______
Humidity Transmitter (Omit if not required)
-H205 ±2% Humidity Transmitter, 0 to 5 VDC output
$80.00
$_______
-H210 ±2% Humidity Transmitter, 0 to 10 VDC output
$80.00
$_______
-H212 ±2% Humidity Transmitter, 2 to 10 VDC output
$80.00
$_______
Setpoint Display Options (Skip if not required)
Desired Range
Designator
Desired Range
Designator
P
60 to 80 °F or 15 to 27 °C
E
A
65 to 80 °F or 18 to 27 °C
F
-# -5 to +5
B
70 to 74 °F or 21 to 23 °C
L
C
45 to 96 °F or 7 to 36 °C
G
D
Setpoint Output Value Range (Skip if not required)
Desired Range
Designator
Desired Range
Designator
23
15 k to 5 kΩ
61 Any
25
0 to 20 kΩ
80 Setpoint
## 1800 to 2200 Ω
27
4.75 k to 24.75 kΩ
81 $6.00
$_______
40
7.87 k to 27.87 kΩ
83
41
10 k to 30 kΩ
84
42
0 to 100 kΩ
90
60
0 to 5 V*
00*
Additional Setpoint Ranges are Available. See App. Notes Pg. 2 for complete list.
SETPOINT LEGEND (insert Designator #)
Legend Range Designator Legend Range Designator
L0
COOL/WARM
L6
Additional Legends are Available. Call BAPI for more information.
Sensor Type (If resistive sensor required)
-0
100 Platinum RTD, 100Ω @ 0°C, 0.385Ω/°C temp coeff. RTD's
-1375
1K Platinum RTD, 1,000Ω @ 0°C, 3.75Ω/°C temp coeff. $25.00
$_______
-1NI
1K Nickel RTD, 1,000Ω @ 21°C, 5Ω/°C temp coeff. or
-1
1K Platinum RTD, 1,000Ω @ 0°C, 3.85Ω/°C temp coeff. $35 for 1NI
$_______
-2
2K Silicon RTD, 2,000Ω @ 20°C, 8Ω/°C temp coeff.
-18
1.8K Thermistor, 1,800Ω @ 25°C Thermistors
-3
3K Thermistor, 3,000Ω @ 25°C $18.00
$_______
-33
3.3K Thermistor, 3,300Ω @ 25°C
-102
10K-2 Thermistor, 10,000Ω @ 25°C
-103
10K-3 Thermistor, 10,000Ω @ 25°C
-10311
10K-3[11K] Thermistor, 5,238Ω @ 25°C, 11KΩ shunt resistor
-20
20K Thermistor, 20,000Ω @ 25°C
-50
Semi-
-100
conductor
-592
$25.00
$_______
Override Configuration (Must select one)
-J
Override as a Separate Output.*
(Dry contact only, not intended to switch a load.)
$5.00
$_______
-N Override in Parallel (//) with Sensor
$5.00
$_______
-P Override in Parallel (//) with Setpoint: NOT available on voltage setpoint models
$5.00
$_______
-Z No Override. (Needed if no override is required)
$0.00
Optional Communication Jack (Mounted in unit's base)
-C11L RJ11 (4 pin) Style Jack with Leads
$20.00
$_______
-C11LT RJ11 (4 pin) Style Jack with Leads and Terminal Block
$20.00
$_______
-C35L 3.5 mm Phono Jack w/ Leads Attached
$10.00
$_______
-C35LT 3.5 mm Phono Style Jack with Leads and Terminal Block
$10.00
$_______
-C22L RJ22 (4 pin) Style Jack with Leads Attached
$25.00
$_______
-C22LT RJ22 (4 pin) Style Jack with Leads and Terminal Block
$25.00
$_______
Optional Test and Balance Switch
-TB
$7.50
$_______
Differential Ground - Setpoint & Temp Sensor (Skip if not required)
-DF
CO₂ Level Indication** (Must select one)
-LED
-ARW
-BNK No LED or Arrow Indicators, No Legend**
EXAMPLE
BA/
BS3F -ACD05 -H205 -A 80L6 -0 -J -C11L -TB -LED
Example Part Number: BA/BS3F-ACD05-H205-A80L6-0-J-C11L-TB-LED
Total =
$______
CO2 Room Sensor,
BAPI-Stat 3 Enclosure
D9
Rev. 03/09/16
-ACD05
-ACD10
-DCD05
-DCD10
CO as 0 to 2,000 PPM, 0 to 5 VDC output, Single Beam Automatic Background Calibration unit for periodically unoccupied areas
CO as 0 to 2,000 PPM, 0 to 10 VDC output, Dual Channel Calibration "24/7" unit for continuously occupied areas
-2 to +2
-3 to +3
50 to 90 °F or 10 to 32 °C 55 to 85 °F or 13 to 30 °C
674 to 274 Ω
800 to 1200 Ω
0 to 1000 Ω
500 to 1500 Ω
2 k to 3 kΩ
0 to 10 kΩ
Air Quality Sensors
No Legend
50K Thermistor, 50,000Ω @ 25°C 100K Thermistor, 100,000Ω @ 25°C
AD592 Semiconductor, 273 µA @ 0°C
Three Position Switch
Differential Ground (Default is Common Ground)
3-color LED on Logo Plate, "Good, Fair and Poor" Arrow on Display with "Good, Fair and Poor" legend
Your Part Number: Call BAPI if you have questions about the above ordering/pricing grid or the configuration of the product you are ordering. *Not available with Differential Ground (-DF) option
°F
°C Humidity Generic
A
-3 to +3
x x x x x x x x
B
-5 to +5
x x x x x x x x
C
50 to 90°F 10 to 32°C
x x x x x x x x
D
55 to 85°F 13 to 30°C
x x x x x x x x
E
60 to 80°F 15 to 27°C
x x x x x x x x
65 to 80°F 18 to 27°C
G
45 to 96°F 7 to 35°C
x x x x x x x
H
-20 to 120°F -29 to 49°C
x x x x
J
68 to 78°F 20 to 26°C
x x x x x x x x
K
65 to 95°F 18 to 35°C
x x x x x x x
L
70 to 74°F 21 to 23°C
x x x x x x x x
M
0 to 100%RH
x x x
N
35 to 70%RH
x x x
-2 to +2
X
40 to 80°F 4 to 27°C
x x x x x x x x
AA
60 to 85°F 15 to 30°C
x x x x x x x
BB
54 to 90°F 12 to 32°C
x x x x x x x
CC
41 to 85°F 5 to 30°C
x x x x x x x
DD
32 to 100°F 0 to 38°C
x x x x x x x
EE
67 to 77°F 19 to 25°C
x x x x x x x
FF
-10 to +10
x x x x x x x
0 to 100°F -18 to 38°C
JJ
40 to 90°F 4 to 32°C
x x x x x x x
KK
32 to 185°F 0 to 85°C
x x x x
MM
-40 to 140°F -40 to 60°C
x x x x
NN
69 to 75°F 21 to 24°C
x x x x x x x
PP -4 to +4 x x x x x x x
QQ
55 to 95°F 13 to 35°C
x x x x x x x
32 to 212°F 0 to 100°C
SS
25 to 50°F -4 to 10°C
x x x x
0 to 43°C
0 to 43°C
0 to 60°C
0 to 70°C
-99 to 999°C
-40 to 85°C
-40 to 60°C
-40 to 60°C
**Range describes the Output Module Range as well as the Display Range if used with the BAPI-Com.
Setpoint Display Ranges for BAPI Room Sensors
Resistance Output Values for BAPI-Stat 2 & 4 Units with Heat/Cool and Off/Auto Control
Designator RµP RµPS
F
P
GG
RR
An "x" in the box indicates that the output range is available for that room unit. *Setpoint range must be within displayed temperature range
Setpoint Display Range**
Maximum Temperaure Display Range ->
x x x x x x x x
x x x x x x x x
32 to 110°F
32 to 110°F
"Quantum", Decora
& BAPI-Stat 4
32 to 99°F
BAPI Room Sensors With Display
X-Combo*
32 to 158°F
T1K
Room Trans
-147 to 999°F
"Quantum Prime" or BAPI-
x x x
x
Stat 3* Temp & Humidity
-40 to 185°F
"Quantum Prime" or
BAPI-Stat 3* VOC & CO2
-40 to 140°F
BAPI-Com**
Rev. 07/15/13
Setpoint Display & Mode Control Ranges
-40 to 140°F
Resistance Output Values for Units with Fan Speed Control
Designator Room Sensor Models
XLD 5k 10k 15k 20k 25k RuPM, BAPIStat 2 & 4 X01 4.89k 2.33k 10.63k 13.24k 16.33k RuPM, BAPIStat 2 & 4 X02 2k 4k 6k 8k 10k RuPM, BAPIStat 2 & 4 X03 5k 10k 15k RuPM, BAPIStat 2 & 4 X05 4.89k 2.33k 15.8k RuPM, BAPIStat 2 & 4 X06 6.5k 8.5k 10.5k 12k BAPIStat 2 & 4 Only X07 5k 15k BAPIStat 2 & 4 Only X08 12.686k 11.86k 13.86k RuPM, BAPIStat 2 & 4
Fan Speed Control Selection and Resistance Output Value
OFF AUTO LO MED HI ON
Resistance Output Values for Units with Heat/Off/Cool Mode and On/Auto Fan Control
Mode Control Selection and Resistance Output Value
HCF 5k 10k 15k 20k 25k 30k RuPM, BAPIStat 2 & 4
H01 0k 2k 4k 6k 8k 10k RuPM, BAPIStat 2 & 4
Designator Room Sensor Models
H02 5K 10K 15K 20K BAPIStat 2 & 4 Only
Heat/Auto Off/Auto Cool/Auto Heat/On Off/On Cool/On
Mode Control Selection and Resistance Output Value
Heat Cool Auto Off
Room Sensor ModelsDesignator
BAPI Application Notes