BAPI-Stat 4 Modbus Room Sensor
Ordering Information BAPI-Stat4MBRoomUnit-Temperatureand/orHumiditySensor
BA/BS4MB
BAPI-Stat 4 Style Enclosure with Multi-Mode Pushbuttons
$130 $_______
DisplayMode Must select one
F
Temperatures Displayed in °F
C
Temperatures Displayed in °C
Must select one for display units, not available for non-display units
-# SETPOINTDISPLAYOPTIONS
DesiredRange
Designator
DesiredRange
Designator
50 to 90 °F or 10 to 32 °C
C
65 to 80 °F or 18 to 27 °C
F
55 to 85 °F or 13 to 30 °C
D
70 to 74 °F or 21 to 23 °C
L
60 to 80 °F or 15 to 27 °C
E
45 to 96 °F or 7 to 36 °C
G
HumidityMeasurement Must select one
-HN
No Humidity Measurement
-H2
Humidity Measurement
$150 $_______
PushbuttonFanSpeed/ModeOptions Must select one
-FN
No Fan Speed Adjustment
-F0
Fan Speed Mode 0 (available for display units only)
-F1
Fan Speed Mode 1 (available for display units only)
-J
Override Enabled (available for display units only)
B17
Rev. 09/14/15
Humidity or Combination Temp/Humidity Sensors
See App. Notes pg I3 for Additional Setpoint Display Ranges
BA/BS4MB F -E -HN -FN -J
Example Part Number: BA/BS4MBF-E-HN-FN-J
YourPartNumber:
A
-3 to +3
x x x x x x x x
B
-5 to +5
x x x x x x x x
C
50 to 90°F 10 to 32°C
x x x x x x x x
D
55 to 85°F 13 to 30°C
x x x x x x x x
E
60 to 80°F 15 to 27°C
x x x x x x x x
G
45 to 96°F 7 to 35°C
x x x x x x x
H
-20 to 120°F -29 to 49°C
x x x x
J
68 to 78°F 20 to 26°C
x x x x x x x x
K
65 to 95°F 18 to 35°C
x x x x x x x
L
70 to 74°F 21 to 23°C
x x x x x x x x
X
40 to 80°F 4 to 27°C
x x x x x x x x
AA
60 to 85°F 15 to 30°C
x x x x x x x
BB
54 to 90°F 12 to 32°C
x x x x x x x
CC
41 to 85°F 5 to 30°C
x x x x x x x
DD
32 to 100°F 0 to 38°C
x x x x x x x
EE
67 to 77°F 19 to 25°C
x x x x x x x
FF
-10 to +10
x x x x x x x
JJ
40 to 90°F 4 to 32°C
x x x x x x x
KK
32 to 185°F 0 to 85°C
x x x x
MM
-40 to 140°F -40 to 60°C
x x x x
NN
69 to 75°F 21 to 24°C
x x x x x x x
PP -4 to +4 x x x x x x x
QQ
55 to 95°F 13 to 35°C
x x x x x x x
SS
25 to 50°F -4 to 10°C
x x x x
**Range describes the Output Module Range as well as the Display Range if used with the BAPI-Com.
Setpoint Display Ranges for BAPI Room Sensors
Resistance Output Values for BAPI-Stat 2 & 4 Units with Heat/Cool and Off/Auto Control
Designator RµP RµPS
F
P
GG
RR
An "x" in the box indicates that the output range is available for that room unit.
*Setpoint range must be within displayed temperature range
Setpoint Display Range**
Maximum Temperaure Display Range ->
x x x x x x x x
x x x x x x x x
32 to 110°F
32 to 110°F
"Quantum", Decora
& BAPI-Stat 4
32 to 99°F
BAPI Room Sensors With Display
X-Combo*
32 to 158°F
T1K
Room Trans
-147 to 999°F
"Quantum Prime" or BAPI-
x x x
x
Stat 3* Temp & Humidity
-40 to 185°F
"Quantum Prime" or
BAPI-Stat 3* VOC & CO2
-40 to 140°F
BAPI-Com**
Rev. 07/15/13
Setpoint Display & Mode Control Ranges
-40 to 140°F
Resistance Output Values for Units with Fan Speed Control
Designator Room Sensor Models
XLD 5k 10k 15k 20k 25k RuPM, BAPIStat 2 & 4
X01 4.89k 2.33k 10.63k 13.24k 16.33k RuPM, BAPIStat 2 & 4
X02 2k 4k 6k 8k 10k RuPM, BAPIStat 2 & 4
X03 5k 10k 15k RuPM, BAPIStat 2 & 4
X05 4.89k 2.33k 15.8k RuPM, BAPIStat 2 & 4
X06 6.5k 8.5k 10.5k 12k BAPIStat 2 & 4 Only
X07 5k 15k BAPIStat 2 & 4 Only
X08 12.686k 11.86k 13.86k RuPM, BAPIStat 2 & 4
Fan Speed Control Selection and Resistance Output Value
OFF AUTO LO MED HI ON
Resistance Output Values for Units with Heat/Off/Cool Mode and On/Auto Fan Control
Mode Control Selection and Resistance Output Value
HCF 5k 10k 15k 20k 25k 30k RuPM, BAPIStat 2 & 4
H01 0k 2k 4k 6k 8k 10k RuPM, BAPIStat 2 & 4
Designator Room Sensor Models
H02 5K 10K 15K 20K BAPIStat 2 & 4 Only
Heat/Auto Off/Auto Cool/Auto Heat/On Off/On Cool/On
Mode Control Selection and Resistance Output Value
Heat Cool Auto Off
Room Sensor ModelsDesignator
BAPI Application Notes
I3