Installation
J93099
Instructions
J93099 Kit Installation Instructions for Cutter blade and Backing Plate
Components of this kit are a dimensionally matched set. You may have parts that look similar, but they are different
dimensionally if received before May 1
1. Remove old cutter blade screws, cutter blade and backing plate and discard.
2. See illustrations to determine the correct positions for component assembly.
3. Hold cutter blade and backing plate together, insert screws and tighten to 8-14 ft-lbs.
4. Choose the correct length bolts supplied in this kit for your tool. Fully tensioned bolts should flush or extend beyond
the cutter blade ¼” max.
Operating Tip: Keep the bolts tight (8-14 ft-lbs.). A loose bolt may cause cracking or premature wear of the cutter blade
and/or backing plate. This could result in improper clamp tensioning, locking, and cutting.
Operating Tip: Keep the leading edges of the cutter blade and backing plate free of metal shavings. Metal shavings will
result in clamp band gouging during tensioning. Clean and hone the leading edges by hand. Do not use power tools.
Honing should polish surfaces, not remove material.
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
P: 1-800-525-0758
F: 1-800-624-3925
st
, 2004. Parts received before May 1
st
, 2004 should be discarded.
www.BAND-IT-IDEX.com
Page 1 of 2
Cutter Blade Kit
Document # P15488 Rev. D
© Copyright
BAND-IT-IDEX, Inc. 2007
All rights reserved
Installation
Instructions
J93099
Cutter Blade Kit
J93099 Kit Installation Instructions for Cutter blade and Backing Plate
Components of this kit are a dimensionally matched set. You may have parts that look similar, but they are different
dimensionally if received before May 1
1. Remove old cutter blade screws, cutter blade and backing plate and discard.
2. See illustrations to determine the correct positions for component assembly.
3. Hold cutter blade and backing plate together, insert screws and tighten to 8-14 ft-lbs.
4. Choose the correct length bolts supplied in this kit for your tool. Fully tensioned bolts should flush or extend beyond
the cutter blade ¼” max.
Operating Tip: Keep the bolts tight (8-14 ft-lbs.). A loose bolt may cause cracking or premature wear of the cutter blade
and/or backing plate. This could result in improper clamp tensioning, locking, and cutting.
Operating Tip: Keep the leading edges of the cutter blade and backing plate free of metal shavings. Metal shavings will
result in clamp band gouging during tensioning. Clean and hone the leading edges by hand. Do not use power tools.
Honing should polish surfaces, not remove material.
st
, 2004. Parts received before May 1
st
, 2004 should be discarded.
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
P: 1-800-525-0758
F: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 1 of 2
Document # P15488 Rev. D
© Copyright
BAND-IT-IDEX, Inc. 2007
All rights reserved
Installation
J93099
Instructions
Hand Tools
½” long
Leading
Edge
Backing
Plate
Cutter
Blade
Air Tools
1-3/4” long – S750, S100
2” long – S350
Hone these
surfaces
Rough edges on
clamp band are
indication of need to
hone cutter blade.
Cutter Blade Kit
CAUTION: To prevent breakage,
backing plate must be installed flush
with cutter blade.
CORRECT
Backing Plate
Cutter Blade
INCORRECT
Installation
Instructions
Hand Tools
½” long
Leading
Edge
Backing
Plate
Cutter
Blade
Air Tools
1-3/4” long – S750, S100
2” long – S350
Hone these
surfaces
Rough edges on
clamp band are
indication of need to
hone cutter blade.
J93099
Cutter Blade Kit
CAUTION: To prevent breakage,
backing plate must be installed flush
with cutter blade.
CORRECT
Backing Plate
Cutter Blade