1. Band may be used from bulk roll as this
completely eliminates waste of band. Slide
buckle on band as shown, bringing end of
band around object to be clamped and
again through buckle.
4. Place finger on BAND-IT Band at buckle
bridge while tensioning with tool handle.
When you feel BAND-IT Band stop moving
through buckle as you are turning handle,
maximum pressure is being exerted by the
BAND-IT Band around object being
clamped. Stop turning handle.
2. Continue band around object once
more and again through buckle.
Double banding develops a great deal
more radial compression than single
banding. Bend end of band under
buckle.
5. Roll tool over buckle, backing off with
tension handle1- 1½ turns throughout entire
rolling operation. Failure to back off tension
with tension handle throughout entire course
of roll-over may result in breaking of band.
There is no loss of tension as band released
is used up in the bend.
Hand Tool
3. Place band in open of tool nose and
gripper block. Move into slot as far as
possible, to avoid buckle sliding into tool
nose. Apply tension by turning handle of
tool.
6. Pull cutting handle to cut the band.
When applying Giant Band clamps, prior
to cutting off clamp, release band gripper
and push tool nose away from buckle
approx. ¼”.
7. Remove tool,
holding stub of band
down with thumb.
8. Hammer
down buckle
ears to complete
BAND-IT clamp.
![](/html/ad/ad71/ad7191ffb817a3cbaa6ede62b6569dc5a84c7763aa58e1ff5d266db936a9911d/bg2.png)
CABLE JOINTS, CABLE TERMINATIONS, CABLE GLANDS, CABLE CLEATS
FEEDER PILLARS, FUSE LINKS, ARC FLASH, CABLE ROLLERS, CUT-OUTS
11KV 33KV CABLE JOINTS & CABLE TERMINATIONS
FURSE EARTHING
www.cablejoints.co.uk
Thorne and Derrick UK
Tel 0044 191 490 1547 Fax00441914775371
Tel 0044 117 977 4647 Fax00441179775582
Cleaning and
G40269 Giant II
Warranty
Hand Tool
Gripper Cleaning Instructions:
1. Remove gripper. Align gripper pin
hole with notch in tool frame. Using a
punch and hammer, punch pin out of
slide block.
2. Using a wire brush, clean all
foreign matter from teeth.
NOTE: Periodically apply food-grade white lubricant or equivalent to tension screw thread (on
page 3) to prevent excessive wear.
If tool fails to securely grip tail of clamp, follow gripper cleaning instructions above.
3. Replace pin: Align gripper hole with
slide block hole, insert pin in hole and
hammer pin in place.
Refer to website for warranty information: http://www.band-it-idex.com/warranty.html