Operating
A92079
Instructions
Warning:
Always wear safety glasses when operating hand tool.
Instructions:
1. Turn tension adjustment knob until desired tension setting is displayed in tension indicator window. Space between numbers counts as one-half setting. See step 6.
2. Extend handle open to release gripping mechanism and insert clamp tail into tool through front load entry.
3. Squeeze handle repeatedly to tighten band around object. Be sure to release handle completely to use full pull-up stroke of tool. Buckle must be secure against the tool head and nestled between the two retention clips. Once the preset tension has been reached, the handle will no longer release completely.
4. To cut-off excess clamp tail, squeeze handle one last time.
5. The tool must be reset by, extending the handle out until it snaps into place, the tool will be ready to apply the next clamp.
6. Tension Setting Range:
.250 Smooth I.D. Tie-Lok 0 – 8
Tie-Lok II Tool
Tension
Adjustment
Knob
Tension Indicator
Window
Handle
BAND-IT-IDEX, Inc. A Unit of IDEX Corporation 4799 Dahlia Street Denver, CO 80216-3070 USA P: 1-800-525-0758 F: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 1 of 4
Document # A92051 rev. H
© Copyright
BAND-IT-IDEX, Inc. 2006
All rights reserved
Repair Parts
24, 34
23, 32, 33
25, 34
26
22, 31
A92079
Tie-Lok II Tool
1
2
3
4
5
6
7, 32
8
9
10
11
21
29
13
20
12
14, 32
19
18, 32 27, 34
See list of tool
17
28, 34
BAND-IT-IDEX, Inc. A Unit of IDEX Corporation 4799 Dahlia Street Denver, CO 80216-3070 USA P: 1-800-525-0758 F: 1-800-624-3925
www.BAND-IT-IDEX.com
16, 32
Page 2 of 4
15
14, 32
Document # A92051 rev. H
BAND-IT-IDEX, Inc. 2006
head parts on next page
cut-off link and pin shown as a reference from next page
© Copyright
All rights reserved
Loading...
+ 2 hidden pages