class 216,3 ÷ 41,9BTG 3,6 P170300101N AC 50Hz 230V0,101)
class 2
class 216,3 ÷ 41,9BTG 3,6 P170300101N AC 60Hz 220V0,101)
Thermal
output
kW kW
16,6 ÷ 42,7BTG 3170000101N AC 50Hz 230V0,091)
16,6 ÷ 42,7BTG 3170000101N AC 60Hz 220V0,091)
ModelPart no.
Frequency 50 Hz
Frequency 60 Hz
Electrical
supply
MotorNotes
GAS BURNER ACCESSORIES
Boiler coupling kit, plug for wiring.
NOTES
1 Equipped with air closure device.
Net calorific value at reference conditions of 0°C, 1013mbar:
Natural Gas: Hi = 35,80 MJ/m
LPG: Hi = 92 MJ/m
For different type of gas and pressure values, please get in contact with our commercial department.
3
= 8550 kcal/m3.
3
= 22000 kcal/m3.
3
Page 4
kW 16 - 42
THERMAL OUTPUT kW
BTG 3
ediz.06/2012
THERMAL OUTPUT kW
BTG 3,6 P
BURNER/GAS TRAIN MATCH
SERIES BTG
GAS
Pressure drop
(combustion head + gas train)
17
16
15
PRESSURE mbar
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
10 15 20 25 30 35 40 45 50
ediz.06/2012
Natural Gas
Pressure drop
(combustion head + gas train)
5,5
5,0
1A
1J
PRESSURE mbar
4,5
4,0
3,5
3,0
2,5
2,0
1,5
1,0
0,5
0,0
101520253035404550
Natural Gas
9A
CE gas train version complies with EN676, EXP gas train version is for extra-European markets
Burner
model
Gas
type
BTG 3Natural gas
BTG 3,6 PNatural gas
Burner
model
Gas
type
BTG 3LGP
BTG 3,6 PLGP
Curve
on graph
Version
CE/EXP360
Version
1ACE/EXP6519990466Included––M2
1JEXP4019990235–96000030–ME1
9ACE/EXP360
P.Max **
CE6519990466Included––M2
EXP4019990235–96000030–ME1
mbar
P.Max **
mbar
Execution
CTV19990016Included–98000100B212)
Execution
19990016Included––B2
CTV19990016Included–98000100B212)
Gas train
Part no.Part no.Part no.Part no.
19990016Included––B2
Gas train
Part no.Part no.Part no.Part no.
Regulator with
incorporated filter
Regulator with
incorporated filter
To choose the correct gas train please refer to the information on Burners Catalogue.
NOTES
12Valve tightness control not required by EN676.
CTV Gas train with Valve Tightness Control.
**) Maximum gas inlet pressure at pressure regulator.
Burner/gas train
adapter
Burner/gas train
adapter
Valve tightness
control kit
Valve tightness
control kit
Pic. Notes
Pic.Notes
4
Page 5
GAS TRAIN STRUCTURE AND COMPOSITION
C
B2B1
B1
B2
Gas train Part no.
19990016 (MB... 405 - 1/2”)
M2
VLVPSRVSPmin
LDU
Pct
VL2
VPS
RVS PminF
Position
Gas train dimensions
mm
Size of
packagingmmWeight
FLDU Pct PminRVL2 VPSVSØB1B2CL x P x Hkg
llll
F
l
n
3/4”72210204300 x 210 x 3005
B2B1
B1
C
GAS
Gas train Part no.
19990466 (MBC... 65 - 1/2”)
ME1
Gas train Part no.
19990235
Position
Gas train
dimensions
mm
Size of
packaging
mm
Weight
FPminRVLVPSVSØB1B2CL x P x Hkg
lllll
VLP
min
Position
1/2”67150198240 x 220 x 2102
B2B1
C
Gas train
dimensions
mm
Size of
packaging
mm
Weight
PminVLØB1B2CL x P x Hkg
l
1/2"1/2"72151110240 x 220 x 2102
CTV Valve tightness control.
F Filter.
LDU LDU valve tightness control.
Pct Pressure switch for gas control.
Pmax Maximum pressure switch.
Pmc Minimum and control pressure
switch gas leaks.
Pmin Minimum pressure switch.
R Pressure regulator.
RF Pressure regulator with filter.
RFP Pressure regulator with filter for
pilot gas train.
RM Manual flow rate regulator.
RP Pneumatic regualtor.
VF Regulator throttle valve.
VL Operating valve.
VL2 Two-stage operating valve.
VLP Operating pilot valve.
VLR Operating valve with pressure
regulator.
VP Pilot valve.
VPS VPS valve tightness control.
VS Safety valve.
VSP Safety pilot valve.
Ø Gas train diameter.
Ø1 Main gas train diameter.
Ø2 Pilot gas train diameter.
l
As standard.
s
As standard for burners with an
output of more than 1200 kW, on
request for burners with an output
of less than 1200 kW.